Optex iVISION+ IVP-GU, iVISION+ IVP-GUG Installation Instructions Manual

IVP-GU(G) features
“OPEN DOOR” Relay Output Function AC/DC (10~24V) Adaptable Chime On-Off Mode
* Relay Output function must meet other requirements dependent on the third party equipment. OPTEX will not be held responsible for any damage or injuries caused due to using this function.
Installation Instructions
Wireless Video Intercom
IMPORTANT NOTICE
1.
Operations under harsh environments such as out of warranted temperature, rapid temperature change, high humidity, constant moisturization may cause the unit to malfunction.
Electronic device such as TVs, Radios, PCs, Microwave ovens or any other device with an electric motor may cause the unit to malfunction.
Impact or shocks can cause severe damage to the unit. Please handle the unit with care and operate without exerting strong forces.
Transmission range of communication between units may decrease under the following conditions.
- Any unit is installed on a metal surface.
- Presence of reinforced concrete, steel doors or other metal construction materials between units.
- Places near strong radio sources such as broadcast stations or substations.
While installing/using a Gateway Chime Unit
- Do not install/use in damp, steamy or dusty environments.
- Do not hold the Gateway Chime Unit to your ear - your hearing could be damaged.
- Do not install in an unstable location or where subject to strong vibration.
PARTS IDENTIFICATION
3.
CHOOSING LOCATION
2.
If there is a pre-existing door bell inside the house, a Gateway Chime Unit (IVP-GU) may be capable of adapting the pre-existing power wires (AC/DC 10-24V 3 Wmax).
IVP-GU should be located in a place where the unit has a clear signal reception and transmission availability.
The performance of a IVP-GU is dependent on the transmission environment of radio signals from locations of connecting units. A communication range will be significantly reduced by more number and thickness of walls which the signal is required to pass.
For iVISION+ system, maximum communication range is around 300ft (100m) in an open air environment. Following materials may decrease the maximum communication range and may potentially cause loss of transmission signals.
• Metal barricades such as metal doors and shutters.
• Walls with aluminium foil insulation.
• Concrete or galvanized metal walls.
Gateway Chime Unit uses 2.4GHz radio frequency for iVISION+ system.
The Gateway Chime Unit needs to be powered from an AC/DC 10-24V 3W(max) power source. An open ended third party power adapter may be available from local electronics stores. Power input has no polarity. Please make sure to tighten terminal screws to avoid loose ends. If applicable, configure all pairing setup and carry out feasibility study before mounting on a wall.
Speaker
LED Indicator
Gateway Chime Unit (Front)
POWERING THE UNIT
4.
ATTENTION:
Thank you for purchasing the iVISION+ wireless video intercom. Before installation and usage, please read this instruction manual thoroughly and keep this safe for future reference.
Mounting Screw
Gateway Chime Unit (Back)
Power input
Relay output
Pairing button A& B
Chime ON/OFF switch
Fixing Screw
Mounting Plate
INSTALLATION
5.
For the optimal radio performance, mount IVP-GUs high on a wall and in an open area avoiding a metal surface and surrounding.
(1) Fix a Mounting Plate on a feasible location (2) Run a power cable to the location
and connect to the Power input. If applicable, also run a relay connection from the Relay output to the third party equipment.
(3) Slide the IVP-GU onto the Mounting Plate and tighten the Fixing Screw at the bottom.
One iVISION+ system can host up to 2 units of Gateway Chime Unit (IVP-GU).
N.C. COM N.O.
AC/DC 10-24V
Relayoutput
Powerinput
Mounting Screw
toPowerinput
toRelayoutput
21mm/0.83”
Tightenascrew
Slideon
toapowersource
toathirdparty equipment
If “OPEN DOOR” Relay Output function is used, please carefully choose a location for each of IVP-GU to secure a physicalaccess to the IVP-GU.
Mounting Plate
(optional)
WARRANTY
9.
SPECIFICATION
8.
MODEL NAME: OPTEX iVISION+ (IVP-GU) Gateway Chime Unit
Operating Temperature
8-1
Dimensions
8-2
Specification Table
ADDITIONAL SETTING
7.
(1) Entering Pairing mode of a Gateway Chime Unit (IVP-GU). An IVP-GU is already set in a “Pairing mode” at the factory default setting. To change IVP-GU into the “Pairing mode”, press down both A and B buttons and hold until LED will brink in green and red.
To change a chime volume of IVP-GU – Press button A to acknowledge current chime volume level. Press A button again to change volume level to the next. The volume changes within 4 levels and the lowest volume will follow the loudest. Leave the setting at the desirable volume level. To completely turn off the chime, set Sound ON/OFF Switch to OFF.
110mm / 4.33”
80mm / 3.15”
Dust/Water Protection
Radiowave Frequency
0 to 40 degC (32 to 104 degF)
< 90% RH (no condensation)
N/A (Indoor Use Only)
2.4 GHz and 418MHz
Operating Humidity
Power
AC/DC 10-24V 3W(max)
5923260
REV 1.00
OPTEX INC. (U.S.)
URL: http://www.optexamerica.com/
OPTEX DO BRASIL LTDA. (Brazil)
URL: http://www.optex.net/br/es/sec/
OPTEX (EUROPE) LTD. / EMEA HQ (U.K.)
URL: http://www.optexeurope.com/
OPTEX CO., LTD. (JAPAN)
URL: http://www.optex.net/
Pairing button
(3) Confirming IVP-GU with a HOME ID. When IVP-GU is assigned a new HOME ID, beeping stops and LED stops flashing to indicate the normal operation mode.
30.3mm / 1.2”
(2) Prepare Handheld Monitor Unit (IVP-HU) for assigning a HOME ID for IVP-GU. Press “Paring Button” on the back of an IVP-HU and choose “SCAN” by clicking “left function key” on the IVP-HU. The IVP-HU starts scanning for a new device.
Handheld Monitor Unit (IVP-HU)
1. This product is under a warranty for a normal usage for 18 months from the date of manufacturing. The date of manufacturing can be identified from a LOT number indicated on a label placed in a back of IVP-GU.
2. The warranty may not be applicable when any of following circumstances is found.
- Mechanical or electrical modification is made to the product and the good’s appearance indicates an alterations or a significant damage.
- The product is already been diagnosed by someone other than the manufacturer.
- Product malfunction is resulting from an improper usage, an accident, natural disaster or any environmental event.
- Please call our technical assistance before arranging a return.
LOT: YYWWZ (e.g. LOT 1350Z)
YY indicates last two digits of the year manufactured (e.g. “13” = Year 2013) WW indicates Xth week of the year manufactured (e.g. “50” = 50th week)
Relay Output
1C 50VAC/24VDC 1A max
PAIRING WITH OTHER iVISION+ DEVICES
6.
NOTE: One Handheld Monitor Unit (IVP-HU) must be configured to have a HOME ID*
1
prior to paring up with other iVISION+ devices. For setting up a new HOME ID, please refer to the Installation Instructions of IVP-HU. A Handheld Monitor Unit bundled with Door Camera Unit (IVP-DU) already has a HOME ID set up and paired up to each other.
*
1
HOME ID is an unique identification number for your iVISION+ system.
Pairing button A& B
Sound ON/OFF Switch
While the IVP-GU is in a factory default setting, the unit has not been assigned to a HOME ID. When powering the unit, green and red LED will flash with beep sound to indicate its paring mode. Please proceed to (2). (... continues onto the other side)
The Gateway Chime Unit operates regardless of the switch setting while power is being supplied.
This switch is for turning ON/OFF a speaker.
One iVISION+ system can host up to 2 units of Gateway Chime Unit (IVP-GU).