Optex INSQXIST Quick Start Guide

59-3061-1 2212-27
INSTALLATION INSTRUCTIONS
Quick Guide
INS-QXI-ST
INS-QXI-ST
VISUAL VERIFICATION PIR CAMERA
<< Contents >>
Before installation
- Manufacturer's statement
- Parts identification
- Accessories
- CHeKT account
Step
1
Installation
DHCP
2
IP address settings
Enable
Disable
series
Before installation
Page
- Manufacturer's statement
1
2
Warning
Caution
Prohibition
Warning
Destroy
Disassemble
Full information is available at
https://navi.optex.net/manual/50426
This “Quick Guide” is the part of the entire installation instructions that guides the installation procedures for installers.
Get the full information of the installation instructions from the web site.
If you need a guide to the operation of the whole system, please consult the installer of the entire system.
Failure to follow the instructions provided with this indication and improper handling may cause death or serious injury.
Failure to follow the instructions provided with this indication and improper handling may cause injury and/or property damage.
Recommendation
Caution
modify
Special attention is required to the
NOTE
section of this symbol.
Mounting on an unstable wall
InSIght Camera manual
https://navi.optex.net/manual/50426/en/?type=cameramanual
3
Device registration to CHeKT portal
4
Camera angle and PIR area settings
5
Checking
Others
- Specifications
- Dimensions
- Detection area
- Compliance
https://support.chekt.com
CHeKT support
3
4
Intentional watering
- Parts identification
Bracket angle adjusting screw
PIR detector
Mounting plate
Back cover
PIR cover
- Accessories
4 x 20 mm
Mounting screws
- CHeKT account
If you do not have a CHeKT account, request a dealer account by visiting the
“CHeKT dealer” , before Step 3. Refer to the “CHeKT support” for more details.
T20 Torx wrench
Camera unit Camera angle adjusting screw
Waterproof cap
for LAN connection
PIR area masking strips
CHeKT dealer
www.chekt.com/registration
https://support.chekt.com
1
CHeKT support
Step
1
Installation
1-1. Disassemble
1
2
1-3. Connect cables to device.
NOTE
Only the connector can be fixed
inside the body with double-sided
tape. The LAN connector must be
stored in the wall.
DC power cable
12 V DC power for camera and PIR
3
8-pin I/O cable
Pink
Orange
Yellow
Brown
Green
Purple
Black
Red
1-2. Install the mounting plate using 2 screws
PoE LAN
cable
NOTE
To pass cables through the wall, drill a 25 mm (1") or larger hole in the wall.
Use a single gang box for exposed wiring.
Tamper
Alarm
Do not connect to the N/A terminal.
SP N/A COM AL TP TP
It can be also used as a back up
-
Power
+
for POE
Waterproof cap
for LAN connection
Refer to the Web manual how to use the cap.
Caution
Caution
Hook the fall prevent wire.
1-4. Secure the main body
1 2
Put the main body back on the mounting plate.
Caution
Do not pinch the cables during assembly.
The default network type of InSight is dynamic.
If you have a DHCP server, it will automatically set the InSight.
Jump to Step 3
Step
2
IP address settings
If you do not have a DHCP server, it will set as follows after one minute.
Initial address: Refer to the label on the InSight
User name: root
Default password: OPTEX
Change your password as appropriate.
Download IP installer;
https://navi.optex.net/firmware/50426
Refer to the “InSight IP camera install manual” for more details;
https://navi.optex.net/manual/50426/en/?type=cameramanual
InSight Camera manual
Step
4
Detection area settings and walk test
Changing for each item in this step is optional.
Check the default settings and if no changes are required, proceed to the next item.
Further information, refer to the “INS-QXI-ST Full manual” on the Web.
Step
3
Device registration to CHeKT portal
Setup your CHeKT Dealer Portal:
1. Go to http://dealer.chekt.com/ to log in.
2. Select the Customer on the left side of the dashboard.
3. Select the Site Devices tab.
4. Select the bridge device to be associated with the sensor camera.
5. Access the bridge settings using the gear icon to its right.
6. Select the appropriate tab to register the PIR camera.
Refer to the site for more details.
CHeKT suppor
https://support.chekt.com
4-1. Horizontal adjustings
1
Remove the Back cover.
2
Adjust horizontal angle.
INS-QXI-ST Full manual
https://navi.optex.net/manual/50426/en/?type=installationinstructions
2
Pull back
1
Raise up
2
Horizontal: ±95°
NOTE
Only one side needs to be loosened.
4-2. Vertical adjustings
PIR area adjustment
1
Vertical: 0° to -20°
Caution
Do not use the vertical angle adjustment of the main unit other than adjusting the detection area surface to be parallel to the ground inclination.
Adjust the detection range
Parallel
2
Camera angle adjustment
Loosen the screw to adjust camera angle
Angle can be adjusted with either left or right screw.
20°min.
Default
30°
35°max.
NOTE
It is recommended that use the Camera angle at 25° to 35°
since camera images may appear white and blurred in dark scenes.
4-3. PIR/VCA settings
Refer to the InSight VCA manual for details on PIR and VCA area settings.
InSight VCA manual
https://navi.optex.net/manual/50426/en/?type=VCAmanual
4-4. PIR area masking
4-5. Switch settings
The default settings are 12.0 m (40') 120° wide.
If no masking of the detection area is required,
proceed to the next item.
INS-QXI-ST Full manual
https://navi.optex.net/manual/50426/en/?type=installationinstructions
Caution
If the vertical angle of the camera is to be adjusted, adjustment of this
sections must be matched to ensure the best performance of the sensor.
3 4
3 4
High
Low
Default
4 5 6 7 8
3
2
1
Super High
3 4
Middle
Default
3 4
Future use
PIR sensitivity
ON OFF
Alarm output N.O. N.C. Do not change *
LED ON OFF
* Alarm output must be kept to N.C. N.O. setting may cause unstable performance.
Caution
Do not move the mirror nor PCB from the factory settings as Pet alley cannot be set.
4-6. Put on the back cover
Step
5
Checking
1
2
Walk test: Check the detection area by walking around the area.
System check: Check the image at the time of detection on the monitoring portal.
3
Others
- Specifications
Model
Detection method PIR coverage PIR zones Detectable speed Sensitivity
Power input
Terminal 9.5 to 16 V DC/ 20 mA max. at 12 V DC
Alarm period
Warm-up period
Alarm output
N.C/N.O. switchable, 28 V DC 0.1 A max.
Tamper output
LED indicator
[1] Warm-up [2] Alarm [3] Walk test end Image sensor Viewing angle Minimum illumination IR illumination Night vision
Day & Night Automatic/Manual switching Image compression Resolution/ frame rate
Network protocol
Security Operation temperature
1080/ 30 fps, D1 (704 x 480 or 704 x 576)
IPv4: TCP/IP, UDP, RTP(UDP/TCP), RTSP, NTP, HTTP,
HTTPS, SSL, DHCP, SNMPv1/v2/v3(MIB-2), ONVIF
HTTPS(SSL), IP filtering, 802.1x, Digest authentication (ID/PW)
Environment humidity International protection Mounting
Mounting height Weight
Accessories
Specifications and designs are subject to change without prior notice.
These un its are designed to detect an int ruder and activate an alarm contr ol panel.
Being on ly a part of a co mplete system, we c annot ac cept res ponsibili ty for any damages or other consequenc es resulti ng from an i ntrusi on.
INS-QXI-ST
Passive infrared
12.0 m (40') 120° wide 40 zones
0.3 to 2.0 m/s (1' to 6'7"/s)
2.0 ( 3.6°F) at 0.6 m/s
PoE (IEEE 802.3af compliant)
Mini-jack 12 V DC 420 mA max.
2.0 ± 0.5 s
Approx. 60 s (LED blinks)
N.C. 28 V DC 0.1 A max.
Open when the cover is opened
1/2.8” CMOS
H: 114° V: 61°
Color: 0.02 lux. 0 lux. with IR
Visible up to 12 m
H.264, H.265, MJPEG
-30 to +50(-22°F to +122°F)
95% max.
IP 54
Wall (Outdoor, Indoor)/Gang box
2.2 to 2.7 m (7'3" to 8'11")
0.85kg(30.0 oz)
[1] Mounting screw (4 x 20 mm) x 2 [2] T20 Torx wrench x 1 [3] Area masking strips x 1 [4] Waterproof cap for LAN connector x 1
- Detection area
Top view
Side view
Pet alley can not be set because the camera performance is not fully exhibited.
Caution
0
5
7.5 m
6
4
2
0
2
4
6 20
7.5 m 0
5
0
2.2 m
2.7 m
0
Do not slide the main unit of the detector.
Do not raise the mirror of the detector.
20
10
15
e
f
f
e
3
6
25920
1510
6
3
40 ft.
303525
25 ft.
20
d
d
9
30
Camera
15
c
10
b
5
PIR
0
a
5
b
10
c
15
25 ft.
12 m
40 ft.
35
7’ 3” 8’ 11”
12 m
- Dimensions
84 (3.31) 209 (8.23)
140 (5.51)
83.5 (3.29)
214 (8.43)
Unit: mm (inch)
- Compliance
Personal Information
This product is equipped with the function to produce moving image of the designated area and
its surrounding, but not equipped with the function to store or register such image.
Prior to the installation of this product, the compliance to local laws and regulations needs to be
confirmed by the user of this product for the lawful installation and use of this product, and
signage and notification when using this product. User of this product is deemed to be
responsible for the compliance of any laws and regulations relating to personal information,
privacy protection and rights of portrait upon use of this product. Image taken by this product is
required to be treated appropriately under the responsibility of the user of this product.
Installation of this product, producing image, monitoring, recording with camera and handling of
personal information or data shall all be performed under discretion and responsibility of user of
this product, and OPTEX shall not be held liable for any dispute between a user and a third party.
FCC notification
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and
used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his own expense.
About distribution of source code for open source software
This product includes open source software("OSS") distributed under OSS License. In
compliance with the OSS Licenses such as GPL (GNU GENERAL PUBLIC LICENSE), LGPL
(GNU LESSERGENERAL PUBLIC LICENSE), and/or others included, we are making the source
code of the OSS available, at the actual cost, to our customer upon his/her request. The source
code corresponding to OSS included in this product will be provided in a prescribed manner for
at least than three(3) years after the date of purchase. Please note that the OSS is provided
without warranty of any kind.
Follow the steps below to perform a factory reset (for example, forget the password). The IP address, ID, password and camera settings are initialized.
1
3
Cable
Factory reset switch
Press for 5 seconds to reset.
Caution
Do not pinch the cable when restoring the PIR detector.
2
EU/UK contact information
https://navi.optex.net/cert/contact/
OPTEX IN C./AMERICAS HQ (U.S.)
www.optexamerica.com
OPTEX (EURO PE) LTD./EMEA HQ (U.K.)
www.optex-europe.com
OPTEX SECURITY B.V. (The Neth erlands)
www.optex-europe.com/nl
4
OPTEX CO., LTD. (JAPAN)
www.optex.net
OPTEX SECUR ITY SAS (France)
www.optex-europe.com/fr
OPTEX SECUR ITY Sp. z o.o. (Poland)
www.optex-europe.com/pl
OPTEX PIN NACLE INDIA , PVT., LTD. (India)
www.optexpinnacle.com
OPTEX KOREA CO., LTD. (Korea)
www.optexkorea.com
OPTEX (DO NGGUAN) CO.,LTD. SHANGHA I OFFICE (China)
www.optexchina.com
OPTEX (T hailand) CO., LTD. (Thailand)
www.optex.co.th
Copyrig ht (C) 2021-2022 OPTEX CO.,LTD.
Loading...