Optex FitLink Quick Reference Manual

1
3
2
2’7” to 3’11”
(0.8 to 1.2m)
Parallel
It’s extremely important to stay within recommend heights of 2ft.,7in. to 3ft.,11in. to prevent missed and unwanted alarms.
MOUNTING HEIGHT
FitLink QUICK REFERENCE GUIDE
DETECTION RANGE
MOUNTING POSITION
Make sure to adjust detection range to best fit application.
16.4' (5m) or 6.6' (2m)
Make sure to keep detector vertical and level to the ground. When mounting detector, do not tilt, turn upside down, or mount horizontal. Detector should alway be mounted vertical for best operation.
4
FINAL TESTING
Make sure to insert battery to power detector and perform Walk Test. After unit has been installed and programmed, make sure to walk test and confirm detector is performing affectively. Once confirmed be sure to flip dip switch #1 from TEST (factory setting) to NORMAL.
TEST:
Regardless of DIP switch 4 (LED) and DIP switch 2 (BATTERY SAVING MODE) settings, LED will illuminate and detector will trigger every time. This is used for Walk Test ONLY.
NORMAL:
The LED lights depending on the DIP switch 4 (LED) setting and DIP switch 2 (BATTERY SAVING MODE) setting is active.
Horizontal Upside DownTilt
If 6.6’ (2m) is required, rotate the lower lens 180 degrees.
Do not remove the upper lens.
Note>>
16.4ft. (5m) detection length (Factory default)
6.6ft. (2m) detection length
3.3
3.9
(ft)
2.6
3.30 6.6 9.8 13 16.4 (ft)
3.3
3.9
(ft)
2.6
0 6.6 9.8 13 16.4
(ft)
Side view
Side view
ON
1 2 3 4 5 6
TEST
NORM
Not detected
Detected
PROGRAMMING GUIDE
Front Porch; Backyard Carport; Gate Entrance; Deck
Crawl Space; Basement; Storage Shed;
Garage or Sliding Glass Door; Screened in Porch; Sunroom
Driveway; Sidewalk; Public Areas
No
No
No
No
No
Yes
Yes
No
Yes
Yes
Yes
Yes
No
Instant
Alarm
Entry
delay 2
No
No
Instant
Alarm
Entry
delay 2
No
Yes
Yes
Yes
No
Toggle
On or Off
On during
disarm
On during
disarm
Toggle
On or Off
Location
Panel Event
Chime
Alarm Output Report to CMS
Disarm Away Stay Alarm Trouble
Set up “FITLINK” according to location as desired. Below are zone configurations for typical location types. For specific panel types and programming instructions for your specific control panel, refer to installation instructions.
ENROLLING HONEYWELL ENROLLING INTERLOGIX
ENROLLING 2GIG
ENROLLING DSC
1. While in program mode, press *56 to enter Zone Programming Menu Mode.
2. Select 0 or 1 to determine if you will “confirm” the sensor after learning it.
3. Enter the zone number that you wish to program (or 00 to exit zone programming). Press [*] to continue.
4. A summary display appears, press [*] to continue.
5. Enter “Zone Type” according to table found in Installation Instruction.
6. Enter “Partition No.”
7. Enter “Report codes” according to table.
8. Enter “Input Type” to “3” = RF (supervised RF transmitter).
9. Learn or input transmitters serial number. (To learn FITLINK, trip the tamper three times.)
10. Change “Loop Number” to 1.
1. Select “Wireless Zone #” (01 to 48).
2. Select “Sensor Type” from following:
(23) No Response Type, (03) Perimeter, (02) Exit/Entry 2
3. Select “Sensor Equipment Code” as “[0000] Other or [0609] Existing Motion Detector”.
4. Select “Sensor Other Equip code as “[0]” (this menu only appears if [0000] Other was selected in the previous menu.
5. At the “Sensor Serial Number” menu, press shift, then press Learn, and then trip detector tamper switch.
6. Select “Equipment Age” as “New”.
7. Select “Loop Number ” as “Loop 1”.
8. Select “Dialer Delay” as “Enabled”.
9. Edit “Voice Descriptor” according to location.
10. Select “Sensor Reports” according to above table.
11. Select “Sensor Supervised” to “Enabled”.
12. Select the desired chime.
1. Put control panel in learn sensor mode.
2. Push tamper switch to enroll FITLINK.
3. Press [*] key to confirm ID.
4. Enter [zone #].
5. Enter [zone type]
6. Enter “Loop Number” 1.
7. Set “Zone Types” and “Zone Attributes”
ENROLLING QOLSYS
1. Enter Settings Menu and select "Installation".
2. Select "Security Sensors" and then select "Auto Learn Sensor".
3. Trip the tamper to enroll within 2min.
4. Panel will chime and display the sensor's code. Select OK to confirm.
5. Set "Sensor Type" to "Motion".
6. Set "Sensor Name" to the correct name from the list.
7. Set "Chime Type" to your preferred type.
8. Set “Sensor Group” according to table found in Installation Instruction.
9. Select "Add New" to complete.
1. Put control panel in learn sensor mode.
2. Push tamper switch to enroll FITLINK.
3. Depending on panel type, select “Sensor Number”,
“Sensor group”, Sensor Name, and/or partition. Refer to your control panel RF programming guide for specific details. OPTEX recommendations can be found in the FitLink manual.
4. Press save to save the changes.
For programming technical support: 877-260-5578
For OPTEX support: 800-966-7839