Optex CX-502, CX-502AM, CX-502V Installation Instructions And Use

CX-502, CX-502V, CX-502AM
PASSIVE INFRARED DETECTOR
CX-502
-
Double Conductive Shielding of the pyroelectric element
- Extremely High Light and RFI Immunity (Patent listed)
-
-
LED On/Off Switch
-
Super Quad Zone Logic
-
Temperature Compensation
-
Sealed Optics
-
Silent Relay
-
LED Remote Control Terminal ((BE) model only)
FEATURES
OPTION
LONG RANGE LENS : CL-80N FA-1W : Wall Mount Bracket : adjustable ±45° (Horizontally), 0-20° (Vertically downwards) FA-3 : Compact Wall & Ceiling Bracket : adjustable ±45° (Horizontally), 0-10° (Vertically downwards)
1.INSTALLATION HINTS
3.DESCRIPTION AND OPERATION
2.DETECTION AREA
Avoid Curtain,Screen,etc. blocking detection area.
Avoid vapor or high humidity that can cause condensation.
Avoid direct unlight.
Do not install outdoors.
Avoid mounting detector where movement of Fans or Air Conditioning Fans can be detected.
When damage has occured to the product, i.e. water logged, abnormal things inside product, overheating or smoking, strange smells etc., immediately stop using product and contact your supplier. Otherwise, continued use in such condition may cause electric shock or fire hazard.
WARNING
Never repair or modify product. It may cause accident, fire hazard or electric shock.
‡E ‡F ‡G
WARNING
CAUTION
Mount securely. A falling product may cause injury.
7.TROUBLE SHOOTING
NOTE
This unit is designed to detect movement of an intruder and activate an
alarm control panel.
Being only part of a complete alarm system,we cannot accept
responsibility for any damages or other consequences resulting from an
intrusion.
This product confirms to the EMC Directive 89/336 EEC.
Dimensions : inches (mm)
No.0881 0001-11 59-0881-1 00-03
*Specifications and design are subject to change without prior notice.
PROBLEM
RED LED does not light.
RED LED lights even though no person within area.
RED LED lights but signal is not sent.
Red LED does not stop flickering (warm-up)
Yellow LED flickers (CX-502AM only)
Red and Yellow LED does not stop flickering.(warm-up)
PROBABLE CAUSE Improper power supply voltage. (disconnection,low voltage) Improper detection area. LED switch is OFF. Improper polarity to detector. Moving object within area. (curtain, wall hanging, etc.) Temperature of object within area changing rapidly (heater, air conditioning, etc.) Relay contact is stuck or damaged due to overloading. Faulty wiring.
Insufficient power supply.
Detector is masked.
Strong light, electrical noise cause anti-masking false alarm. Incorrect initialization. Insufficient power supply.
REMEDY
Correct supply voltage to 9~18V DC.
[See Section 2~4]. Turn on the switch. Switch positive and negative at terminal. Remove the souces from the detection area. Remove object from detection area. Check load of output. The unit needs repair or replacement.
Wire correctly.
Correct supply voltage to 9~18V DC.
Remove masking material and continuous double flickering of Red LED stops after several seconds.
Remove such causes.
Initialize correctly according to [Section 6-6]. Correct supply voltage to 9~18V DC.
CX-502AM 7mA(normal) / 19mA(max.)
See Section6-4 See Section6-4
Red and Yellow LED is blinking during warm-up period.
Red LED-Alarm , Alarm Memory and Initial Alarm Memory indicator
Yellow LED-Anti Masking , Self-check indicator
See Section6-2 N.C. 28VDC 0.2A max.
4.8oz(135g)
Model Current draw Alarm Memory Initial Alarm Memory
LED Indicator
D.L.terminal Trouble output Weight
8.SPECIFICATIONS
CX-502 V Only
-
Alarm Memory
-
LED Remote Control Terminal
Wiring Knockout
Terminals
Corner mount Knockout
Tamper switch
Mounting Knockout
Pitch 2.99inch(76mm)
WIDE ANGLE
LONG RANGE
TOP VIEW
SIDE VIEW
Sensor
(Double Conductive Shield)
Do not touch.
Sensitivity Selector
(See section 6-1)
TOP VIEW
SIDE VIEW
IMPORTANT
When using the optional “Long” range lens, ensure that the
detection mode switch is set to the “STD” position.
Ensure that the SENS Switch is set to the “H” position when the detector is to be used in ranges longer than 67ft(20m).
CX-502 AM Only
-
Advanced Anti-Masking Technology
-
Self-check
-
Alarm Memory and Initial Alarm Memory
-
LED Remote Control Terminal
-
2 LED Indication
STANDARD ALARM MEMORY ANTI-MASKING
2.76(70)
4.53 (115)
2.06 (52.3)
CX-502V 5mA(normal) / 13mA(max.) See Section6-4 See Section6-2
4.2oz(120g)
Model Current draw Alarm Memory D.L.terminal Weight
Model Detection method
Coverage
Detection zones Mounting height Sensitivity
Detectable speed Power input Current draw Alarm period Alarm output Tamper switch Warm-up period
LED indicator
D.L.terminal ((BE) Only)
RF interference Operating temperature
Environment humidity Weight
CX-502 Passive infrared Wide angle 85° wide 50ft x 50ft (15m x 15m) 82 zones 6 ~ 10ft(1.8 ~ 3.0m) 3° F (1.6° C) at 2ft / sec (0.6m/sec) 1~ 5ft / sec (0.3 ~ 1.5m/sec) 9 ~ 18VDC 5mA (normal) / 12mA (max.)
2.0 ± 0.5sec N.C. 28VDC 0.2A max. N.C. Opens when cover is removed. Approx. 1 min.(LED blinks) LED is blinking during warm-up period. Alarm condition See Section6-2 No alarm 30V/m
-4°F ~ +122°F(-20°C ~ +50°C)
95% max.
4.2oz (120g)
Anti-masking prism
(CX-502AM only)
Do not touch.
Base
LED Indicator
80ft x 7.7ft (24m x 2.3m) 22 zones
Coverage
Detection zones
CL-80N ( Optional lens for long range curtain pattern )
Cover Fastening
Screw
No.0881
Lens
Cover
4.INSTALLATION
5.WIRING
Loosen fastening screw and remove cover.
Wire according to Section 5.
Lead in wires through knockouts along the wiring guide on the rear side of base. Mount base with supplied screws. When
Conduct a walktest and make adjustments. (Section 6) Fit cover using fastening screw.
CX-502 AM
CX-502
TROUBLE OUTPUT (N.C.)
base, setting the guides on the both sides of the upper part of the main unit with the claws of the base housing.
Line up the guides on both sides of the upper part of the main unit with the claws of the base housing. Push it onto the base housing and slide down the main unit locking them together.
6.FUNCTIONS
This is done by releasing it from the two notches either side of the lens and pulling away. To replace it, line up the lens with the guides on the inner cover of the detector and hook the holes back into the claws.
TAMPER
(N.C.)
ALARM OUTPUT
(N.C.)
ALARM MEMORY
POWER INPUT
(9~18 VDC)
SPARE
1. SENSITIVITY SELECTOR
To adjust the sensitivity , first remove the lens (as this covers the sensitivity switch).See the procedure on 4-5. This switch may be used where:
A) Turn the switch to “L” (Low) position when the detector is installed in a
hostile area, which may cause a false alarm.
It may be used in situations where the area of coverage may be small or narrow. Where small animals may be present or where there may be sudden temperature changes.
B) Turn the switch to “H” (High) position when greater sensitivity is required,
example (in Long Range applications exceeding 67ft (20m), areas with high temperatures which reduce the temperature difference between the target and background, or when the detector is mounted at higher than 9ft (2.7m).
INITIAL ALARM MEMORY
CX-502 V
D.L.
(Disable LED)
ALARM
MEMORY
POWER INPUT
(9~18 VDC)
ALARM OUTPUT
(N.C.)
When using the “Long range” lens or to get access to the sensitivity selector switch it is necessary to remove the lens.
ON - OFF
3. DETECTION MODE (PULSE COUNT)
DIP SWITCH
•TROUBLE OUTPUT SELECTOR
•POLARITY SELECTOR
•DETECTION MODE
•LED ON/OFF
SENSITIVITY SELECTOR
RESET Alarm Memory resets automatically when system is re­armed. l-
Wiring of Alarm Memory
- Compatible Control Panel is required for Alarm Memory.
- Connect A.M. terminal to Control Panel's Control Voltage
- Signal terminal (System Arming Status Voltage Output).
- See the section 6-5 as to the switching of System Status.
-
Wiring of Initial Alarm Memory Connect I.A. terminals of the detectors in one loop.(Parallel Connection) NOTE:Maximum 40 detectors can be connected in one loop for initial alarm memory.
T.O.+ALARM•-T.O
..
..
.
Power wires should not exceed the following
lengths.
SWITCH POSITION
OFF
ON
OUTPUT TERMINAL
TROUBLE(T.O.)
TROUBLE(T.O.) and ALARM
Type of trouble
Anti-Masking
Self-Check
Anti-Masking and Self-Check
Yellow LED Indication
Blinks slowly (0.5sec)
It lights constantly
Blinks fast (0.2sec)
Operation The LED display for the Alarm Memory and the Initial Alarm Memory turns “ON” only when the LED SW or remote control by the DL terminal is “OFF” while the system is in the disarm condition.
SP - STDSP - STD
SP - STDSP - STD
SP - STD
Switch Position
POSITIVE
NEGATIVE
Terminal input
status
OPEN or +5~18VDC 0~1VDC(grounded) OPEN or +5~18VDC 0~1VDC(grounded)
DL
operation
ON OFF OFF
ON
"grounded" = A.M. and D.L. terminals are electrically connected with power supply terminal (ground).
ALARM MEMORY
operation
Armed Disarmed Disarmed
Armed
POSI - NEGA
Always conduct a walk test after changing the position of this switch to ensure the detector is still providing optimum coverage.
CAUTION!
SPARE
(Non Shorted)
The main unit can be released from it’s base by following the procedure below.
Push up the main unit until it is released from the claws of the base housing. Pull the unit out from the
The Detection Mode can be switched to either “Standard” or “Special” mode depending on the environmental conditions of the installation. *Ensure that the “STD” position is used when the “Long” range lens is fitted.
STD : For normal applications. SP : For use in hostile areas where there may be movement
from small animals or other objects such as fax machines or curtains.
When the “SP” is selected, the detector’s sensitivity may seem sluggish. It is therefore important to always conduct a walk test to ensure that the desired coverage is given.
Alarm Memory ( CX-502V , CX-502AM only ) This function is used to indicate if the detector was activated while the panel was armed. It will cause the red LED on the Detector to illuminate once the panel has been disarmed.
Initial Alarm Memory ( CX-502AM only ) When several detectors are on the same loop with the alarm memory function, after disarming:
1) The first detector to be activated flashes its LED.
2) On any subsequent detectors that became activated the red LED will stay on.
• Alarm Memory and Initial Alarm Memory will not activate while system is disarmed.
• After Alarm Memory and Initial Alarm Memory latches, Alarm Output operate normally during armed period.
The Anti-Masking function protects the detector’s lens from being covered by either an object or from hostile substances such as spray, therefore allowing it to detect to its specifications.
The Self-Check function is an onboard circuit, which checks the operation of Detector at regular 5 hour intervals. This ensures that the unit is always Working correctly.
Trouble output: (TO)
This output activates if there is either an Anti-masking detection or a Self-Check problem.
Switching the Trouble Output In the Event of either a Masking or Self­Check problem, then the unit may be set to either activate just the Trouble output or the Trouble and the Alarm outputs. Using DIP Switch 4 makes this selec­tion.
LED display
As well as the trouble output, the yellow LED on the detector will also display the trouble condition.
This function is displayed only when the LED ON / OFF switch or the Remote Control from the DL terminals is “ON” while the system is disarmed.
Anti-Masking
If an object is placed within 10cm in front of the detector, for a period of more than 10 seconds then the Anti-Masking circuit will activate, triggering the Trouble output. When the object is removed away from the lens, and then the Anti-Mask circuit will automatically be reset after one second, switching off the LED indication as well as the Trouble output.
Caution on Installation.
Since the accuracy of the anti-masking detection is very critical, please take note of the following points.
1) Installation. Avoid locating the detector where any objects can be within 1 meter from the detector such as by doors, hanging signs or curtains. Also avoid locating the detector where it may be in direct or reflected sunlight.
2) Powering up the Detector. This type of detector sets its optimum level of performance automatically during warm-up period. This enables it to be set up correctly to provide reliable perfor­mance with the minimum of fuss. To ensure that this setting up is carried out properly, please follow the following instructions carefully. A)- Keep at least 1 meter away from the detector when first applying the power
to the unit.
B)-Keep at least 1 meter from the detector clear of any objects when first apply-
ing the power.
Testing the Detector
1) Ensure that all of the above procedures have been carried out, then apply power to the detector.
2) The detector will go through a warm-up period during which the display LED’s will blink. (The Anti-Masking circuit will also start to set itself to its optimum level at this point).
3) When the LED’s stop blinking the detector is set and ready for use.
(If the LED’s continue to blink then refer to the trouble shooting section).
4) Place an obstacle such as hand within 10cm in front of the detector for more than 10 seconds.
5) The detector works correctly if the yellow LED starts to blink slowly, indicating that it has been masked.
6) Remove the obstruction and the yellow LED should stop flashing. This completes the set up procedure.
1 2 3 4
5 6
7
[ ]
Connect tamper terminals to a 24 hour supervisory loop.
2. LED ON / OFF
Dip SW 1 – Switches the LED “ON” or “OFF”. CX-502 The Alarm LED indicator can be switched either “ON” or “OFF” CX-502V / CX-502AM
1) When the system is armed, the Alarm LED and Trouble LED (CX-502AM only) will not work regardless of the position of this DIP Switch.
2) When the system is disarmed, the Alarm LED and Trouble LED (CX-502AM only) can be selectable to be either “ON” or “OFF”. See the section 6-5 as to the setting of “Arm / Disarm”. When in warm-up mode, the LED’s are activated regardless of the DIP Switch’s position.
POWER INPUT
(9~18 VDC)
* D.L. terminal / LED remote control terminal (CX-502(BE) / CX-502V / CX-502AM only)
LED can be enabled or disabled remotely from
control panel by D.L. terminal.
* Ensure to switch off the LED’s “ON / OFF”
switch * Polarity of CX-502(BE) model is always set as “NEGATIVE”. See the explanation of the Polarity Selector
(6-5) for the control of “ON / OFF”.
4. ALARM MEMORY and INITIAL ALARM MEMORY
5. POLARITY SELECTOR ( CX-502V , CX-502AM only )
This allows detector to be used with a variety of control panel memory latch outputs for either + or – switching. The memory latch from the panel may be used with either the DL function or the Alarm Memory.
(Please note that you cannot set the polarities of these two functions separately.) Please select “ + ” or “ – “ to meet with that of the control panels memory latch output.
6. ANTI-MASKING and SELF-CHECK ( CX-502AM only )
WIRE SIZE 12V 14V 12V 14V 12V 14V
AWG 22(0.33mm2)
1600ft
(480m)
3200ft (960m)
1470ft
(440m)
2930ft (880m)
1060ft
(320m)
2120ft
(640m)
AWG 20(0.52mm2)
2500ft
(750m)
5000ft
(1500m)
2330ft
(700m)
4670ft
(1400m)
1660ft
(500m)
3320ft
(1000m)
AWG 18(0.83mm2)
4000ft
(1200m)
8000ft
(2400m)
3670ft
(1100m)
7330ft
(2200m)
2660ft
(800m)
5320ft
(1600m)
CX-502 CX-502V CX-502AM
D.L.
(Disable LED)
* Long Range Lens CL-80N which has
the number , “51-1522” engraved inside the lens.
*UL requires CX-502,CX-502V,CX-502AM to be connected to a UL listed
power supply capable of providing a nominal input of 12VDC 12mA
(max.) [CX-502] ,12VDC 13mA (max.) [CX-502V] ,12VDC 19mA(max.)
[CX-502AM] and battery standby time of 4 hours.
*The equipment shall be installed in accordance with the National
Electrical Code,NFPA 70.
TAMPER(N.C.)
When using two or more units on one wire, the maximum length is obtained by dividing the maximum wire length listed above by the number of units used.
D.L.
(Disable LED)
((BE) model only)
SPARE
SPARE
(Shorted)
TAMPER
(N.C.)
ALARM OUTPUT (N.C.)
using a bracket, check matching knockout position before opening mounting holes.
guides
claws
Control Panel
I.A. A.M. I.A. A.M. I.A. A.M.