ADVANCED INDOOR DETECTOR
REGENERATION FOR
INDOOR DETECTION
CDX
CDX-DAM
CDX-NAM
CDX-AM
series
15m x 15m wide PIR & MW
detector with anti-mask
24m x 2m long range PIR
detector with anti-mask
15m x 15m wide PIR
detector with anti-mask
DIGITAL QUAD ZONE LOGIC
2.4m
0
105 15m
CDX series has 82 dense zones.
In the detection coverage, 4 or
more zones must be crossed to
distinguish between human and
small animal detection.
In addition, newly developed
digital MPU "CORE PLATFORM"
provides more accurate
detection.
ACTIVE IR DIGITAL ANTI-MASKING TOUGH MICROWAVE MODULE
CDX series uses AIR technology to detect masking.
To realize a stable performance, CDX series differentiate between
true masking and other masking caused by environmental changes
such as dust/dirt adhesion, temperature changes and direct light
by optimizing it's sensitivity.
Most of combination detectors use an universal MW module.
OPTEX developed an original MW module specially designed
for security detector.This stabilize the detection performance
from natural degradation to realize a long operating life.
Temperature
changes
High humidity Oxidation
degradation
ADVANCED INDOOR DETECTOR
CDX
series
Sealing sponge
TerminalsCover
Quick setting
Plug-in EOL Unit(OPTION
)
3 types of signals-Alarm, Trouble and Tamper
- can be recognized by Plug-in EOL unit. Only
a simple plug-in setting is required to enjoy
this function.
COVERAGE
WIDE ANGLE
TOP VIEW
0
(m)
7
5
(
CDX-AM/DAM)
10 20 30 40 50(
)
()
20
MW
10
Lens
Double Conductive Shielding
(CDX-AM/DAM only)
By using our Double Conductive Shielding,
the visible light disturbance and RFI can be
blocked.
Lens
Infrared Rays Double Shielding
Pyro Electric Element
Amp
Sharply-directed MW Technology
(CDX-DAM only)
Conventional MW technology can emit an
unwanted detection area. Sharply-directed
MW technology eliminated those areas to
create detection area close to PIR.
MW
PIR
Quick installation
Spacious Wiring Guide
Spacious wiring guide located in the rear of
the detector provides an aesthetic
installation and also leaves a flexibility to
adjust detector location aer wiring.
Quick exchange
Interchangeable Main Unit
By incorporating an
interchangeable
main unit, CDX
series can easily
be switched to
another model
across the series
according to
customer's request.
0
5
7
0 5 10 15(m
SIDE VIEW
0 10 20 30 40 50(
(m)
0
1.8
2.4
3.0
0 5 10 15(m
10
(
CDX-NAM)
LONG RANGE
TOP VIEW
0 2010 30 40 60 7050 80()
(m)
2
1
0
1
2
0 5 10 15 20
SIDE VIEW
0 10 20 30 40 60 7050
(m)
0
1.8
2.4
3.0
0 5 10 15 20 24(m)
)
0 (
6
8
10
)
0
10
PIR
20
)
)
5()
0
5
24(m)
80()
0 ()
6
8
10
SPECIFICATIONS DIMENSIONS OPTIONS
Model CDX-NAM CDX-AM CDX-DAM
Detection method
Detector standard
Masking detection
method
PIR Coverage
(
Detection zones
Power supply
Current consumption
Alarm output
Tamper switch
Trouble output
Operating temperature
Environmental humidity
RF interference
Mounting height
Weight
Dimensions (Hx Wx D
Specifications and design are subject to change without prior notice.
*
24m x 2m
)
narrow (20 zones
N.C. Opens when cover is removed of the wall tamper switch operates. 28V DC 0.1A max.
)
Passive infrared
EN50131-2-2 (Grade 3
(
)
80. x 7.
)
17mA (normal) / 20mA (max.
at 12V DC
140 x 70 x 52.3 mm (5.51 x 2.76 x 2.06 inches
)
AIR type
15m x 15m (50. x 50.) 85° wide (82 zones
9 - 18VDC
)
N.C. 28V DC 0.2A max.
N.C. 28V DC 0.2A max.
-10°C - +50°C (14°F - 122°F
95% max.
No alarm 10V/m
1.8 - 2.4m (6 - 8.
180g (6.3oz
)
)
)
Passive infrared & Microwave
EN50131-2-4 (Grade 3
)
19mA (normal) / 26mA (max.
at 12V DC
)
)
)
140 (5.51
)
70 (2.67
)
52.3 (2.06
Unit:mm (inch)
)
FA-3
Compact Wall &
Ceiling Bracket
FA-1W
Wall Mount Bracket
800.966.7839
sales@optexamerica.com
www.optexamerica.com