Optex AX-200PLUS Specsheet

NEW SHORT-RANGE
PHOTOELECTRIC DETECTOR
100/200 PLUS
R
100/200 ALPHA
5 YEAR WARRANTY
Photoelectric Detectors Improved with OPTEX Innovation to Provide Advanced Performance in Outdoor Detection.
OPTEX Photoelectric Detectors with Innovative Features for Easy Installation Provide Stable Performance against False Alarms for More Effective Outdoor Detection and Non Security Applications.
The OPTEX AX-100/200 Photoelectric Detector Series is the next step in Outdoor Detection and will satisfy all the needs of both users and installers. OPTEX unique technology and design provide a wide range of functions that greatly simplify installation and maintain reliable performance even in many adverse weather or environmental conditions.
Reliable Technology from
Reliable Technology from
OPTEX Provides All the Outdoor
OPTEX Provides All the Outdoor
Security You Need
Security You Need
Front Cover
STANDARD VERSION
AX-100/200
1.
QUICK OPTICAL ALIGNMENT
Alarm Indication LED in Viewfinder
The alarm condition is visually displayed using an alarm indication LED which is visible on the front of the unit and can also be seen through the viewfinder.
LED is "ON"
: Beam energy from the transmitter is not reaching the receiver.
LED is "OFF"
: Beam energy from transmitter is reaching the receiver.
Fine Adjustment
PLUS
(Note: Fine adjustment must always be done with a Volt Meter - See Installation Instructions.)
PHOTO: AX-200ALPHA
RELIABLE PERFORMANCE
2.
Lightning & Surge Protection
An improved EMI surge absorber and high surge resistiveness relay will maintain stable operation even in the most lightning prone areas.
Lightning Protection Level
Conventional Detector
AX Series
2 4 6 8 10 12 140
Lightning Surge Voltage Level
Will remain stable against over 14kV of lightning surge.
(kV)
Clear Viewfinder Visibility
A conveniently placed viewfinder allows for easy alignment even in some of the most difficult mounting situations.
Fine Angle Adjustment for Alignment
The rotating dial allows the installer to finely adjust the beam easily either horizontally (180°/ with or without the use of a screwdriver (finger adjustable).
±
90°) or vertically (10°/±5°)
Rain, Dust & Insect Protection
The Rubber O-Ring & Rubber Grommets used in the AX­100/200PLUS & ALPHA Series prevent rain, dust and tiny insects from adversely affecting performance. (IP55)
Some product parts in the photo on the right appear transparent for photographic purposes
.
Rubber O-Ring
Rubber Grommets
Frost & Dew Protection
An anti-frost and convex visor design is incorporated to protect the detector from effect of frost & dew.
High Grade Aspherical Lens
The high grade aspherical lens creates more sharply defined & precise infrared beams compared to ordinary fresnel lenses.
3.2inches(82mm)
2.4ft. at 100ft. (0.73m at 30m)
4.8ft. at 200ft. (1.46m at 60m)
Wiring Knockout
Unit Base
Course Alignment LED (AX-100/200ALPHA only)
Monitor Jack
Viewfinder
Vertical Alignment Dial
Horizontal Alignment Dial
Terminals
Beam Interruption Time Adjustment
Beam Frequency Select Switch (AX-100/200ALPHA only)
Alarm Indicator (Receiver)
Transmitting Condition (Transmitter)
High Grade Aspherical Lens
Unit Base Mounting Screw
SUPERIOR VERSION
AX-100/200
3 Step LED Indicator for Fast and Accurate Fine Beam Alignment
The alignment condition is visually displayed on the front and in the viewfinder of the receiver. Verification of alignment is achieved by using the 3-step process shown below.
LED is "ON"
: Before alignment.
LED is "Flickering"
: Beam energy from transmitter is reaching receiver.
LED is "OFF"
: Ready for fine tuning.
Fine Adjustment
ALPHA
(Note: Fine adjustment must always be done with a Volt Meter - See Installation Instructions.)
Twin Synchronized Pulsed Beams Designed for Greater Stability
"And Gate" dual beams require simultaneous interruption of both beams to trigger an activation. No activation is generated when a bird or falling leaves break just one beam.
99.5% Beam Blocking Stability
Enables stable operation with as much as 99.5% loss of beam energy caused by heavy rain, dust storms, fog or snow.
A.G.C. (Automatic Gain Control) Circuit
The A.G.C. Circuit continually monitors for gradual changes in the signal's strength caused by changing weather conditions. It adjusts the sensitivity accordingly to maintain the proper signal level for the current environmental conditions.
Adjustable Beam Interruption Period
The Beam Interruption Time (the amount of time a beam must be broken for an alarm to occur) can be adjusted to fit any application. For example, when protecting a wall or fence, a longer interruption time will catch intruders, but let jumping cats pass through without setting off an alarm.
Selectable 4-Channel Beam Frequencies
The selectable beam frequencies can be used to avoid unwanted cross talk that can occur when using multiple photobeams for long distance or beam stacking applications.
1
2 Beam Stacking
TRANSMITTER RECEIVER
TRANSMITTER RECEIVER
2
2 Beam Long Distance Stacking
TRANSMITTER
Ch1 Ch1
Ch3 Ch3
TRANSMITTER
RECEIVER
Ch1 Ch1
Ch3 Ch3
RECEIVER
RECEIVER
Ch1 Ch1
Ch3 Ch3
RECEIVER
TRANSMITTER
TRANSMITTER
TRANSMITTER
Ch2
Ch4
TRANSMITTER
RECEIVER
Ch2
Ch4
RECEIVER
50msec 100msec 200msec 350msec 500msec
Form C Relay Providing More Flexibility
DESIGN DURABILITY
3.
Highly Durable & Heat-Resistant Housing Cover & Chassis
The housing cover & chassis provide higher durability against shocks, high temperatures and many other harsh environmental conditions.
Stainless Steel Screws & Back Plate
RELIABILITY CHART FOR OUTDOOR PROTECTION
Specially designed to prevent various causes of outdoor false alarms.
False Alarm Causes Technology to Solve AX Function & Features Lighting & High EMI Disturbances High EMI Resistance High Surge Resistiveness Relay & EMI Surge Absorber Insect Entering into Housing Sealed Enclosure Housing IP55 Dew Condensation High Sensitivity Tolerance Ultra High Power Beam Fog, Frost & Heavy Rain Fine Optical Beam Alignment Anti-Frost Mechanism
Easy Optical Alignment Mechanism Course Alignment LED (AX-ALPHA Series Only)
Automatic Gain Control
Birds or Flying Objects
Cross Talk of Beams Beam Discrimination
Size Analysis
Twin Synchronization Pulsed Beams Selectable Beam Frequencies (AX-ALPHA Series Only)
SPECIFICATIONS
MODEL Detection Method
Range
Maximum Arrival Distance
Beam Characteristics Selectable Beam
Frequency
Interruption Period 50 500msec ( Selectable ) Power Input
Current Draw (Transmitter+Receiver)
Alarm Period Alarm Output Form C Relay ( 28V DC 0.2A max ) Tamper Switch N.C. opens when cover is removed (Receiver Only) Operating T emperature Environment Humidity Alignment Angle Mounting Weight
Outdoor Indoor
AX-100PLUS AX-200PLUS AX-100ALPHA AX-200ALPHA
Infrared Photoelectric 100ft. ( 30m ) 200ft. ( 60m ) 200ft. ( 60m ) 400ft. ( 120m ) 200ft. ( 60m ) 400ft. ( 120m )
1000ft. ( 300m ) 2000ft. ( 600m ) 1000ft. ( 300m ) 2000ft. ( 600m)
Pulsed infrared
10.5 28V DC
Normal operation 46mA max
2sec ( ±1 ) nominal
-13°F +131°F (-25°C +55°C ) 95% Max
±
5°Vertical, ±90° Horizontal
36.7oz ( 1040g ) ( Both Transmitter and Receiver )
Wall or Pole
100ft. ( 30m ) 200ft. ( 60m )
4 channel
( Automatic synchronization )
Normal operation 40mA During optical alignment 46mA max
DIMENSIONS
7.7(196)
3.1(78)
3.3(83)
Inches (mm)
3.28(83.5)
OPTIONS
BC-2: Back Cover
Back Cover to conceal the Pole
*Specifications and design are subject to change without prior notice. NOTE: This unit is designed to detect an intruder and activate an
alarm control panel. Being only a part of a complete system, we cannot assume responsibility for theft or damages, should it occur.
F-3: Hood
Hood for rainproof and frostproof
HU-2: Heating Unit
Heating Unit for severe low temperature conditions
Loading...