Photoelectric Detectors Improved with OPTEX Innovation to Provide Advanced
Performance in Outdoor Detection.
OPTEX Photoelectric Detectors with Innovative Features for Easy Installation Provide Stable
Performance against False Alarms for More Effective Outdoor Detection and Non Security Applications.
The OPTEX AX-100/200 Photoelectric Detector Series is the next step in Outdoor Detection and will satisfy all the needs of
both users and installers. OPTEX unique technology and design provide a wide range of functions that greatly simplify
installation and maintain reliable performance even in many adverse weather or environmental conditions.
Reliable Technology from
Reliable Technology from
OPTEX Provides All the Outdoor
OPTEX Provides All the Outdoor
Security You Need
Security You Need
Front Cover
STANDARD VERSION
AX-100/200
1.
QUICK OPTICAL ALIGNMENT
Alarm Indication LED in Viewfinder
The alarm condition is visually displayed using an alarm
indication LED which is visible on the front of the unit and
can also be seen through the viewfinder.
LED is "ON"
: Beam energy from
the transmitter is not
reaching the receiver.
LED is "OFF"
: Beam energy from
transmitter is reaching
the receiver.
Fine Adjustment
PLUS
(Note: Fine adjustment must always be
done with a Volt Meter - See Installation
Instructions.)
PHOTO: AX-200ALPHA
RELIABLE PERFORMANCE
2.
Lightning & Surge Protection
An improved EMI surge absorber and high surge
resistiveness relay will maintain stable operation even in the
most lightning prone areas.
Lightning Protection Level
Conventional
Detector
AX Series
24681012140
Lightning Surge Voltage Level
Will remain stable against over
14kV of lightning surge.
(kV)
Clear Viewfinder Visibility
A conveniently placed viewfinder allows for easy alignment
even in some of the most difficult mounting situations.
Fine Angle Adjustment for Alignment
The rotating dial allows the installer to finely adjust the beam
easily either horizontally (180°/
with or without the use of a screwdriver (finger adjustable).
±
90°) or vertically (10°/±5°)
Rain, Dust & Insect Protection
The Rubber O-Ring & Rubber
Grommets used in the AX100/200PLUS & ALPHA Series
prevent rain, dust and tiny
insects from adversely
affecting performance. (IP55)
Some product parts in the photo on
the right appear transparent for
photographic purposes
.
Rubber O-Ring
Rubber
Grommets
Frost & Dew Protection
An anti-frost and convex visor design is incorporated to protect
the detector from effect of frost & dew.
High Grade Aspherical Lens
The high grade aspherical lens creates more sharply defined &
precise infrared beams compared to ordinary fresnel lenses.
3.2inches(82mm)
2.4ft. at 100ft.
(0.73m at 30m)
4.8ft. at 200ft.
(1.46m at 60m)
Wiring Knockout
Unit Base
Course
Alignment LED
(AX-100/200ALPHA only)
Monitor Jack
Viewfinder
Vertical
Alignment Dial
Horizontal
Alignment Dial
Terminals
Beam Interruption
Time Adjustment
Beam Frequency
Select Switch
(AX-100/200ALPHA only)
Alarm Indicator
(Receiver)
Transmitting
Condition
(Transmitter)
High Grade
Aspherical Lens
Unit Base
Mounting Screw
SUPERIOR VERSION
AX-100/200
3 Step LED Indicator for Fast and
Accurate Fine Beam Alignment
The alignment condition is visually displayed on the
front and in the viewfinder of the receiver. Verification
of alignment is achieved by using the 3-step process
shown below.
LED is "ON"
: Before alignment.
LED is "Flickering"
: Beam energy from
transmitter is reaching
receiver.
LED is "OFF"
: Ready for fine
tuning.
Fine Adjustment
ALPHA
(Note: Fine adjustment must always
be done with a Volt Meter - See
Installation Instructions.)
Twin Synchronized Pulsed Beams
Designed for Greater Stability
"And Gate" dual beams require simultaneous interruption of
both beams to trigger an activation. No activation is generated
when a bird or falling leaves break just one beam.
99.5% Beam Blocking Stability
Enables stable operation with as much as 99.5% loss of beam
energy caused by heavy rain, dust storms, fog or snow.
A.G.C. (Automatic Gain Control) Circuit
The A.G.C. Circuit continually monitors for gradual changes in
the signal's strength caused by changing weather conditions.
It adjusts the sensitivity accordingly to maintain the proper
signal level for the current environmental conditions.
Adjustable Beam Interruption Period
The Beam Interruption Time (the amount of time a beam
must be broken for an alarm to occur) can be adjusted to fit
any application. For example, when protecting a wall or
fence, a longer interruption time will catch intruders, but let
jumping cats pass through without setting off an alarm.
Selectable 4-Channel Beam Frequencies
The selectable beam frequencies can be used to
avoid unwanted cross talk that can occur when using
multiple photobeams for long distance or beam
stacking applications.
The housing cover & chassis provide higher durability
against shocks, high temperatures and many other harsh
environmental conditions.
Stainless Steel Screws & Back Plate
RELIABILITY CHART FOR OUTDOOR PROTECTION
Specially designed to prevent various causes of outdoor false alarms.
False Alarm CausesTechnology to SolveAX Function & Features
Lighting & High EMI DisturbancesHigh EMI ResistanceHigh Surge Resistiveness Relay & EMI Surge Absorber
Insect Entering into HousingSealed Enclosure HousingIP55
Dew CondensationHigh Sensitivity ToleranceUltra High Power Beam
Fog, Frost & Heavy RainFine Optical Beam AlignmentAnti-Frost Mechanism
Easy Optical Alignment Mechanism
Course Alignment LED (AX-ALPHA Series Only)
Automatic Gain Control
Birds or Flying Objects
Cross Talk of BeamsBeam Discrimination
Size Analysis
Twin Synchronization Pulsed Beams
Selectable Beam Frequencies (AX-ALPHA Series Only)
SPECIFICATIONS
MODEL
Detection Method
Range
Maximum Arrival
Distance
Beam Characteristics
Selectable Beam
Frequency
Interruption Period50 500msec ( Selectable )
Power Input
Current Draw
(Transmitter+Receiver)
Alarm Period
Alarm OutputForm C Relay ( 28V DC 0.2A max )
Tamper SwitchN.C. opens when cover is removed (Receiver Only)
Operating T emperature
Environment Humidity
Alignment Angle
Mounting
Weight