Opkon OP-CN4 User Manual

ELECTRICAL CONNECTION
Manufacturer:
34035 Bayrampasa/ISTANBUL/TURKEY
MODEL OP-CN4
UNIVERSAL
INCREMENTAL
COUNTER
Ver 2.0E
USER GUIDE
WARNING!
READ CAREFULLY BEFORE POWER ON
1. Complete electrical connections according to the
schematic at the last page.
2. Check Supply Voltage 220V (or 24V optional) AC, or DC, due to
Specifications on the equipment.
3. Use only shielded cable for sensors.
4. Keep away the equipment from direct heat source.
5. MODEL OP-CN4 is not suitable for outdoor use.
6. Keep away the equipment from water or other liquid
drains.
7. Do not open, modify or replace any component in the equipment, If any problem occurs please contact an authorised OPKON technical service or OPKON directly.
ELECTRICAL SPECIFICATIONS:
Microcontroller based A /B /Z(Reset)-4 X Counter mode 200 kHz Max. counting frequency 2 X Relays output 1 X SSR output Incremental or absolute positioning mode Holding on the last value in memory 10 X Output modes Offset calibration Password to protect menus
Power Supply :220V ± % 20 (or 24V optional) ,50 Hz Power Consumption :<4 VA (protected by fuse 50mA) Sensor supply voltage :+5V or +12VDC (selectable by jumper) Sensor supply current :Max.100mA(no fuse) Relays max. ratings :Relay1 1xNO+NC 8A,230V AC
Relay2 1xNO+NC 8A,230V AC
SSR output :5V DC (non-isolated)
MECHANICAL SPECIFICATIONS:
Dimensions :72x72x90 mm Panel cut dimensions :67x67mm
Body :ABS plastic Working temperature :0-60 ºC Storage temperature :-10ºC …+80ºC Humidity :<%90 RH
DESCRIPTIONS
BUTTONS
1. Resets the counter.
2. Escapes from program menu. COUNTER DISPLAY
1. Enters to program menu.
2. Shifts the rows When programming parameters
PARAMETER DISPLAY
1. Travels in menu.
2. Changes the program
LED INDICATORS
Turns on when equipment programming Indicates Communication RS232(optional).
Turns on when press RST button. OUT1- OUT2 İndicates that Relay1- Relay2 is activated
Indicates that the value on counter display A-B indicates the A-B counting inputs from sensor is Incremental value. By presing UP/DOWN
buttons you can see calibrated value.
MODEL-CN4 MAIN MENU
When normal working mode ;
-Press SET button to Enter Main Menu
- Upper display shows Count value, - Press UP/DOWN buttons to see all
- Lower display shows SET1 Parameter value Parameters in the Menu
MODEL OP -CN4 OUTPUT TYPES