OpenTech Alliance INSOMNIAC CIA K-500 Installation Manual

INSOMNIAC CIA K-500 Keypad
Installation Manual
P/N CIA-575-001
Revision 1.0
Date Code: 1-1-2018
CIA-575-001 Rev 1.0
SPECIFICATIONS: .................................................................................................................... 3
INSTALLATION ......................................................................................................................... 4
General: ................................................................................................................................. 4
Physical Installation and Mounting .......................................................................................... 4
Wiring Connections: ............................................................................................................... 6
PWR/RS485 ....................................................................................................................... 7
RS485 Limitations ............................................................................................................... 7
Wireless Communications (Optional ................................................................................... 7
Relay Outputs ..................................................................................................................... 8
Inputs .................................................................................................................................. 8
Speaker and Call Button ..................................................................................................... 8
Intercom .............................................................................................................................. 8
Earth Ground ...................................................................................................................... 8
Pinhole camera Option........................................................................................................ 8
Testing / Troubleshooting the Keypad .................................................................................... 9
Accessing the Display PCB and Push Button Sub-assembly’s ..............................................10
KEYPAD MAINTENANCE.........................................................................................................11
Cleaning the Housing and Touchpad .....................................................................................11
NOTICES and DISCLAIMERS ..................................................................................................11
Liability Disclaimer .................................................................................................................11
FCC Part 15 Notice ...............................................................................................................11
2 | P a g e
SPECIFICATIONS:
I
D
F
CIA-575-001 Rev 1.0
TEM
ESCRIPTION
EATURES
1 ENCLOSURE INDOOR / OUTDOOR, ALUMINUM, POWER COATED
2 KEYPAD METAL / VANDAL RESISTANT
3 KEYPAD FEEDBACK TACTILE AND AUDIBLE
4 FACEPLATE ALUMINUM , POWDER COATED
5 LCD (OLED) 4-LINE (NON-GRAPHIC)
6 COMMUNICATIONS RS485 OR WIRELESS (900 MHZ)
7 INTERCOM:
SPEAKER
CALL BUTTON
NON INTEGRATED
(AIPHONE)
8 TIME FORMAT 12 OR 24 HOUR
9 DATE FORMAT SELECTABLE
10 FORM-C RELAY OUTPUTS 2
11 SECURE COMMUNICATIONS YES
12 TAMPER INTERNAL + (OPT. EXTERNAL)
13 AUXILIARY INPUTS 4 (OPTO-ISOLATED)
14 WIEGAND INTERFACE 1
15 BLE / IBEACON OPTIONAL (COTS)
16 CAMERA OPTION OPTIONAL (IP/ANALOG)
17 MAX OPERATING VOLTAGE 24VDC
18 MIN OPERATING VOLTAGE 12 VDC
19 MAX INPUT CURRENT 2A
20 MAX ACCESSORY CURRENT .40 A @ 12VDC / .20 A @ 5VDC
21 OPERATING TEMP RANGE -31 TO 150 DEG. F.
22 HUMIDITY 0-95% NON-CONDENSING
23 INGRESS RATING UL294 OUTDOOR EQUIPMENT
24 UL294 PERFORMANCE RATING
2 (II)
3 | P a g e
2
CIA-575-001 Rev 1.0
INSTALLATION
General: The keypad is designed to request access to or from a secured area. It operates in conjunction with a controller that contains the list of access codes and areas these codes are valid for. The controller communicates with a master database that exists centrally accessible via the internet. The central database is the source of the access code to access area and access time correlation as well as all configuration information. The controller will operate standalone using cached data if internet connectivity is lost however no changes in access codes or configuration are possible until internet connectivity to the master database is restored.
The Keypad can be used to control gate access, building access, room access, elevator access, lighting and other security related functions that are relay driven however all of the control logic must be configured in the central controller. Please refer to the user’s manual for the controller in conjunction with this manual. Similarly mounting height and locations for keypads must match local codes regarding handicap access, emergency as well as other regulations. Please see Appendix A for details for common practice mounting diagrams and ADA driven mounting requirements.
Physical Installation and Mounting: The following are instructions on installing a keypad and connecting
the wiring run from the system controller:
1. Open the device by unlocking the security lock on the bottom of the keypad. Then remove the four stainless steel machine screws on the front of the keypad case using a 3mm hex key. The front plate will pivot down as it is hinged at the bottom.
2. Mount the back plate to the desired keypad location using the three-keyed holes in the back panel. If the keypad is being mounted on a factory provided gooseneck, use the provided gasket between gooseneck stand and keypad enclosure. If the keypad is being mounted on a wall, before mounting, run a bead of silicone in a square around the back of the keypad about ½ inch
4 | P a g e
Loading...