OpenEye OE-C1012D2 Quick Start Guide

CONNECTIONS
1
2
1
2
3
3
4
1
2
4
3
4
2
1
DC12V IN
11 RJ-45RJ-45 For network and PoE connectionsFor network and PoE connections
22 Power (12vDC)*Power (12vDC)* Power connectionPower connection
GreyGrey Audio OutAudio Out
33 Audio I/OAudio I/O
44 Alarm I/OAlarm I/O
*12vDC power input port should be plugged when not in use.
11 Reset ButtonReset Button
22 MicroSD Card SlotMicroSD Card Slot
PurplePurple Ground Ground
Green Green Audio InAudio In
BrownBrown GroundGround
YellowYellow Alarm Out +Alarm Out +
WhiteWhite Alarm Out -Alarm Out -
OrangeOrange Alarm InputAlarm Input
BlueBlue GroundGround
To restore the camera to factoryTo restore the camera to factory defaults:defaults:
1. 1. Disconnect power for 30 Disconnect power for 30 seconds.seconds.
2. 2. Reconnect power and wait Reconnect power and wait 30 seconds.30 seconds.
3. 3. Press and hold the reset Press and hold the reset button for 20 seconds.button for 20 seconds.
Supports up to 512GB microSD Supports up to 512GB microSD card for Edge storage.card for Edge storage.
Do not add or remove the Do not add or remove the microSD card when the camera microSD card when the camera is powered on.is powered on.
This quick start guide provides only basic information on the camera’s settings and operation for initial installation. Please read the user manual for
optimal camera congurations.
Waterproof Cable
5
Liberty Lake, WA, USA 509-232-5261
openeye.net
4
3
11 Thread lock capThread lock cap 44 Rubber “O” ringRubber “O” ring 22 Rubber plugRubber plug 55 Camera cableCamera cable 33 RJ45 enclosureRJ45 enclosure
Copyright ©2021 OpenEye. All Rights Reserved. Information contained in this document is subject to change without prior notice. OpenEye does its best to provide accurate information but cannot be held responsible for typos or mistakes.
1
2
OE-C1012D2
2MP | Outdoor | Mini Dome
37483AC openeye.net
CONTENTS INSTALLATION
1. Apply template sticker to desired
camera location.
2. Drill anchor holes using included
mounting template.
OE-C1012D2
Dome Camera
Waterproof Cable
Connector
3. Remove mounting template.
4. Insert anchors.
5. Mount camera.
6. Connect network cable with
included waterproof cable
Security Torx
Tool
connector.
7. Adjust camera view.
8. Secure Lid / dome
Self-Tapping
Screws &
Plastic Anchors
DEFAULT USERNAME AND PASSWORD
Mounting Template
NOTE: OpenEye IP cameras ship
without a default password.
Quick Start
Guide
Optional Free Paintable Dome Cover
This camera has an available paintable dome cover allowing it to be quickly converted to a black housing or the allow custom painting to match its installation environment. To reduce waste it is not included in every package but may be requested free of charge at time of purchase.
POWER
This camera is compatible with 12vDC and Power over Ethernet (PoE). If you are connecting 12vDC power, verify the polarity of the power connection.
NOTE: If the camera will be exposed
to inclement weather, OpenEye recommends sealing around the camera base, or connection to mounting surface with outdoor waterproof caulking.
The admin user password can be set using the following methods:
1. OpenEye recorders running Apex
2.1 or newer will automatically set a new unique password if:
Connected to an M-Series recorder with a built in PoE switch.
Connected to a network switch through the camera network port and selected then added in setup, if a new password has not already been set.
2. Connect to the camera directly
through a Web Browser and follow the onscreen prompts.
3. Use the Network Camera Manager
(NCM) Utility.
Username: admin
NOTE: The NCM software manual can be
found at https://www.openeye.net/
ncm-manual
NOTE: Refer to your Apex recorder manualor
quick start guide for instruction on adding cameras. Passwords must be 9-32 characters including at least two elements of the following three: digits, letters, and special characters.
ASSIGNING AN IP ADDRESS
OpenEye IP cameras are set to DHCP by default. If a DHCP server is not detected after 4 minutes, the camera will default to IP address 192.168.51.2. If you are not using a DHCP server,
NCM will allow you to batch confi gure a
static IP address. The IP address for the camera network on your Apex recorder is 192.168.51.1.
NOTE: To change this IP address please refer to
your Apex recorder manual.
Selecting multiple cameras and enter­ing IP address 192.168.51.2 will set an IP address on all selected cameras, starting at 192.168.51.2 and increase per camera.
1. Open Network Camera Manager.
2. Select applicable camera(s).
3. Input starting IP address, Subnet
Mask, Gateway, DNS.
4. Apply changes.
5. Wait 60 seconds before refreshing
NCM.
CONNECTING TO THE IP CAMERA
To access the camera setup menu, you need to open Network Camera Manager (NCM) utility. NCM is pre­installed on all OpenEye Recorders, and is also available for download on the OpenEye website for installation on your personal computer or laptop.
1. Open Network Camera Manager.
2. Locate your camera on the
Network Camera Manager list.
3. To open the web browser, select
the camera and click LOAD.
PRODUCT FEATURES
Camera
Maximum Resolution 1920x1080
Frame Rate at Maximum Resolution
Total Streams Dual Streaming
ONVIF Profi le S / G / T Compliant
Day/Night True Day / Night
Wide Dynamic Range True WDR
Environmental and Power
Power Consumption
Input Voltage 12vDC / PoE
Pan / Tilt / Rotate
IP Rating IP67
Impact Rating IK10
30FPS @ 2MP H.264/H.265
5.5W Max
Pan: 3° ~ 360°
Tilt: 0° ~ 68°
Rotate: 3° ~ 360°
Loading...