OPCOM X0738CSF User Manual

DOC NOPreliminary 1.0
User Manual
CUSTOMER PRODUCT MODEL NO. DATE
2.4GHz Wireless Digital Transceiver Module DRF-TR001 Nov. 2007
5F, No.12, Innovation Road Ⅰ,
Science-Based Industrial Park, Hsin-chu, Taiwan, R.O.C.
TEL:+886-3-563-5105
FAX:+886-3-563-5107
http://www.elansat.com
E-mail:sales@elansat.com
義聯科技股份有限公司
ELANsat Technologies Inc.
100RT-FRD
Wireless Digital Transceiver ELANsat
Features
Auto ACK & retransmit
On the air max. data rate 2Mpbs
Digital interface (SPI) speed 0~8 Mbps
Software selectable channel form 2402MHz to 2478MHz (77 Selectable channels)
Short switching time enable frequency hopping
Power supply range: 3 V to 3.6 V
Minimum number of external component
Low power consumption: 3.3V, 30mA
Transmission distance: 100 m (Line of sight)
Outline: 23.2 x 20.8 x 4.3 mm
CE 300 328 and FCC 15.247 certificated
Applications
Keyless Entry
Wireless data communication
Alarm and security systems – Wireless home security, Video Door Bell, Video door phone
Home automation
Surveillance – Wireless P-CAM, Video Baby Monitor
Automotive – Wireless Vision-Based Robotic System, Automotive Accessory
Telemetry
Intelligent sports equipment, Video Rockie-Talkie
Industrial sensors
Toys – Camera Radio Controlled Toy
Wireless Photo Frame
Benefits
Ready for production
Reduce time to market
Remove complicity of RF design
No RF experience require
No expensive RF equipment require
Plug and play
No fuse on turning and trimming
No need for expensive external antenna
Page of 7
1
2007.12.06 www.elansat.com Version: 1.0
DRF-TR001 Wireless Digital Transceiver ELANsat
Specification
Parameter

Power Section

Supply Voltage 3 3.3 3.6 V Supply Current in Tx mode 23 30 33 mA Supply Current in Rx mode 17 18 19 mA

Digital Input Section

High level input voltage 2.1 2.25 Vpp
Low level input voltage 0 1.08 Vpp

Digital Output Section

High level output voltage 2.7 3.6 Vpp
Low level output voltage 0 0.3 Vpp

RF Section

Frequency Range 2400 - 2525 MHz
Channel Bandwidth 1.8 2 MHz
TX Power 12 14 16 dBm
MIN TYP MAX
Limits
Unit
RX Sensitivity -81 dBm

Operation

Operating Temperature -10 - +60
Page of 7