Onset RXW-TMB-900 Operating Manual

HOBO® RX Wireless Sensor Network
W
O
C
RXW Temperature Sensor (RXW-TMB-xxx) Manual
This sensor measures temperature and is designed to work with the HOBOnet Wireless Sensor Network in which data is transmitted wirelessly from the sensor mote across the network to the RX3000 station and then uploaded to HOBOlink® web-based software. With HOBOlink, you can monitor sensor readings, view graphs, set up alarms, download data, and more.
Sensor
Measurement Range -40° to 100°C (-40° to 212°F)
RXW Temperature Sensor
Models:
RXW-TMB-900 (US)
RXW-TMB-868 (Europe)
RXW-TMB-922
(Australia/NZ)
Included Items:
Cable ties
Screws
Accessory:
Solar radiation shield (RS3-B)
Accuracy ±0.25°C from -40° to 0°C (±0.45°F from -40° to 32°F)
Resolution 0.02°C (0.036°F)
Drift <0.01°C (0.018°F) per year
Response Time, (typical, to 90% of change)
ireless Mote
perating Temperature
Range
Radio Power 12.6 mW (+11 dBm) non-adjustable
Transmission Range Reliable connection to 457.2 m (1,500 ft) line of sight at 1.8 m (6 ft) high
Wireless Data Standard IEEE 802.15.4
Radio Operating Frequencies
Modulation Employed OQPSK (Offset Quadrature Phase Shift Keying)
Data Rate Up to 250 kbps, non-adjustable
Duty Cycle <1%
Maximum Number of Motes
Battery Type/ Power Source
Battery Life With NiMH batteries: Typical 3–5 years when operated in the
Memory 16 MB
Dimensions Sensor: 5.1 x 33 mm (0.2 x 1.3 inches)
Weight Sensor and cable: 82.5 g (2.91 oz)
Materials Sensor: Stainless steel waterproof tip
Environmental Rating Sensor and cable: Immersion in water up to 50°C (122°F) for 1 year
ompliance Marks RXW-TMB-900: See last page
±0.20°C from 0° to 70°C (±0.36°F from 32° to 158°F) ±0.25°C from 70° to 100°C (±0.45°F from 158° to 212°F)
Without solar radiation shield: 2 minutes, 30 seconds in air moving 1 m/sec With RS3-B solar radiation shield: 5 minutes in air moving 1 m/sec
-25° to 60°C (-13° to 140°F) with rechargeable batteries
-40 to 70°C (-40 to 158°F) with lithium batteries
Reliable connection to 609.6 m (2,000 ft) line of sight at 3 m (10 ft) high
RXW-TMB-900: 904–924 MHz RXW-TMB-868: 866.5 MHz RXW-TMB-922: 916–924 MHz
50 motes per one RX Wireless Sensor Network
Two AA 1.2 V rechargeable NiMH batteries powered by built-in solar panel or two AA 1.5 V lithium batteries for operating conditions of -40 to 70°C (-40 to 158°F)
temperature range -20° to 40°C (-4°F to 104°F) and positioned toward the sun (see Deployment and Mounting), operation outside this range will reduce the battery service life
With lithium batteries: 1 year, typical use
Cable length: 5 m (16.4 ft) Mote: 16.2 x 8.59 x 4.14 cm (6.38 x 3.38 x 1.63 inches)
Mote: 223 g (7.87 oz)
Mote: PCPBT, silicone rubber seal
Mote: IP67, NEMA 6
RXW-TMB-868: The CE Marking identifies this product as complying with all relevant directives in the European Union (EU).
RXW-TMB-922: See last page
22243-A
RXW Temperature Sensor (RXW-TMB-xxx) Manual
Mote Components and Operation
Mounting Tab
Solar Panel
Sensor Cable
Sensor Mote Closed, Front Sensor Mote Closed, Back
Solar Panel Cable
Mounting Tab: Use the tabs at the top and bottom of the mote to mount it (see Deploying and Mounting).
Solar Panel: Position the solar panel towards the sun to charge the mote batteries (see Deploying and Mounting).
Sensor Cable: This is the cable that connects the mote to the sensor.
Eyelet: Use this eyelet to attach a 3/16 inch padlock to the mote for security.
Latch: Use the two latches to open and close the mote door.
Ground Wire Port: Use this port to connect a ground wire (see
Deploying and Mounting).
Antenna: This is the built-in antenna for the radio communications across the RX Wireless Sensor Network.
Solar Panel Cable: This cable connects the built-in solar panel to the mote circuitry.
LEDs: There are two LEDs to the left of the LCD screen. The green LED blinks during the process of joining a network, blinking quickly while the mote searches for a network and then slowly as the mote registers with the network. Once the network registration process is complete, the blue LED blinks at 4 seconds to indicate normal operation. If the mote is not currently part of a network, the blue LED will be off. If the blue LED is on and not blinking, there is a problem with the mote. Contact Onset Technical Support.
Battery Holder: The location where the batteries are installed as shown (see Battery Information).
Latch
Eyelet
Ground Wire Port
LEDs
Antenna
Button
USB Port
Battery Holder
Sensor Mote Opened
LCD Screen
USB Port: Use this port to connect to the mote to a computer via USB cable if you need to update the firmware (see Updating
Mote Firmware).
Button: Push this button for 1 second to illuminate the LCD or 3
seconds for the mote to search for an RX Wireless Sensor Network to join (see Adding the Mote to the RX Wireless Sensor Network).
LCD Screen: The mote is equipped with an LCD screen that displays details about the current status. This example shows all symbols illuminated on the LCD screen followed by definitions of each symbol in the table.
LCD Symbol Description
The battery indicator shows the approximate battery charge remaining.
This is a signal strength indicator. The more bars, the stronger the signal between motes. If there is no x icon next to the signal strength indicator, then the mote is part of an RX Wireless Sensor Network.
An empty signal strength icon plus the x icon indicates that the mote is not currently part of a network. See Adding the Mote to the RX Wireless Sensor Network for details on how to add a mote to the network.
When the mote is in the process of joining a network, the signal strength icon will blink and then the bars in the icon will cycle from left to right. The x icon will blink during the last step in the network registration process (see Adding the Mote to the RX Wireless Sensor Network for details).
This indicates a problem with the sensor itself (the mote is operational). Check the sensor and make any adjustments to it as needed. Contact Onset Technical Support if the problem persists.
Adding the Mote to the RX Wireless Sensor Network
The mote must join an RX Wireless Sensor Network before it can begin measuring temperature and transmitting data. This requires accessing the RX3000 station and the mote at the same time so it is recommended that you complete these steps before deploying the mote.
Important: If you have not configured the RX3000 station with the RXW Manager, follow the instructions in the RX3000 Quick Start before continuing.
To add a mote to the RX Wireless Sensor Network:
1. If the LCD is blank on the RX3000 station, press any button to wake it up.
2. Press the Select button once (which shows the number of smart sensors installed) and then press it again once if the