Onset RX3000 Quick Start Guide

HOBO® RX3000 Remote Monitoring Station Quick Start
RX3000 Station Key Components
LCD
Select button
Ethernet port (RX3001 models)
USB port
Charging port
Log in to HOBOlink.
1
Register the station.
2
In HOBOlink, click Devices and then click the Register a Device link. Give the station a name and enter the serial number and device key from the label inside the station door.
Install optional analog or relay modules.
3
Ensure the station is powered off by pulling the battery and charger connections. Insert optional RXMOD-x modules into the Module 1 or Module 2 slot by plugging the connector into the receptacle on the station. Screw the module in place with the provided screw. If there is just one relay module, install it on the right.
WARNING: If you inadvertently install modules while the power is on, you must disconnect and then reconnect the battery and charging device to guarantee proper operation.
Plug in the battery and charging device.
4
Connect the battery port connector followed by the appropriate charging port connector. Once the battery cable is plugged in, “Initializing System” will flash on the LCD. A checkmark appears next to “System” after the system initialization is complete.
Tip: Refer to the RX3000 manual for instructions on wire routing and environmental sealing of wires.
Battery port, cable connected
Start/ Stop button
Connect/ Search button
Slots for optional user­installed modules
Insert the connector on the module here
Check or configure device communications.
5
For RX3003 cellular models:
The station will automatically connect to HOBOlink after powering up the station in the previous step. Continue to step 6.
A checkmark appears next to Last Connection after connecting to HOBOlink
Connect button
For RX3001 Ethernet models:
a. Plug in the Ethernet cable.
Note: The RX3001 Ethernet station is automatically configured to use DHCP. If your network uses static IP addresses, contact your Network Administrator for the correct addresses and follow the Ethernet configuration steps in the RX3000 manual at www.onsetcomp.com/manual/rx3000.
b. Press the Connect button (under the cloud icon) on
the station to connect to HOBOlink. Wait for a checkmark to appear next to Last Connection as shown in the example above.
For RX3002 Wi-Fi models:
a. Connect the station to the computer with the USB
cable.
b. In HOBOware 3.7.2 or later, select Manage RX3000
from the Device menu. (Select Domain networks and click Allow Access if you see a Windows® Firewall warning.)
c. In the RX3000 Manager, click the Configure button.
d. Enter the Security information for your Wi-Fi
network. Type the Network Name, select the Security Type, and type the Security Key. Consult your Network Administrator or wireless router documentation for help with determining your network security type.
Note: The station uses DHCP by default. If your network uses static IP addresses, contact your Network Administrator for the correct addresses to enter in the Networking fields.
e. Click Save in the RX3000 Manager. Click Done and
then close the RX3000 Manager.
f. Disconnect the USB cable.
g. Press the Connect button (under the cloud icon) on
the station to connect to HOBOlink. Wait for a checkmark to appear next to Last Connection as shown in the example above.
18254-A MAN-QSG-RX3000
Plug in and search for smart sensors.
6
a. Plug in smart sensors into the connectors in the
bottom of the case.
Connect to HOBOlink.
8
Use the Select button to return to the main LCD screen that shows all sensors and modules and then press the Connect button (the cloud icon should be visible as shown in the example). This is necessary for HOBOlink to identify the newly added sensors.
Tip: Refer to the RX3000 manual for instructions on wire routing and environmental sealing of wires.
b. Press the Select button to view the smart sensors on
the LCD and then press the Search button (the magnifying glass icon should be visible as in the example below). The station will search for all connected smart sensors and show the number of channels after a few seconds. Note that some smart sensors have multiple channels (such as the temperature/RH sensors).
Press the Select button to view the smart sensor channels
Connect analog sensors or relay devices.
7
Press the Search button for the station to identify connected smart sensors
Connect any sensors or devices to the optional modules. Refer to the RX3000 manual for details.
Checking the Station in HOBOlink
Press the Select button to return to the main LCD screen
Configure the station in HOBOlink.
9
Press the Connect button
Go to Devices > List and click the icon next to your station or click the station name and then click Configure at the top of the station page. Make changes and click Next to move through the Configuration Assistant to configure the following:
System settings and connection interval.
Smart sensor logging interval and sampling interval.
Settings for each smart sensor (labels, graph, and
scaling).
Optional modules and associated channels.
Any configuration changes will be transferred to the station the next time it connects with HOBOlink.
Start logging.
10
Press the Start button on the station to start logging; the station will connect to HOBOlink.
View smart sensor readings and module information from the last connection
Check the latest connection, configuration, and alarm logs
Export logged data and set up scheduled delivery of exported files
For additional information:
operation, including deployment guidelines, mounting instructions, and steps for installing the weatherproof rubber cable channels. Go to www.onsetcomp.com/manual/rx3000 or scan the code at right:
1-800-LOGGERS (564-4377) • 508-759-9500 www.onsetcomp.com • loggerhelp@onsetcomp.com
See the HOBO RX3000 Remote Monitoring Station Manual for specifications and detailed
© 2015 Onset Computer Corporation. All rights reserved. Onset, HOBO, and HOBOlink are trademarks or registered trademarks of Onset Computer Corporation. All other trademarks are the property of their respective companies.
View graphs of sensor data (if enabled); hover over a series to see individual data points on the graph
18254-A MAN-QSG-RX3000