Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com
Protective Case (CASE-4X-2)
For use with HOBO® 4-Channel Thermocouple Logger (UX120-014M)
Items Included:
• Protective case
• 4 mounting brackets and screws
• 2 grommet assemblies
• 1 dome plug
• Logger removal tool
Desiccant
•
Items Required:
• Phillips screwdriver
• HOBO 4-Channel Thermocouple
Logger (UX120-014M)
• Up to 4 thermocouples (TC6-K,
TC6-J, or TC6-T)
Weight: 397 g (14 oz), not including
logger
Dimensions: 12.17 x 13.41 x 7.04 cm
(4.79 x 5.28 x 2.77 inches), case
12.17 x 16.18 x 7.72 cm (4.79 x 6.37
x 3.04 inches), case with mounting
brackets
1. Use a Phillips screwdriver to attach the four mounting brackets to the back of the case.
2. Plug in all the thermocouples into the appropriate ports (channels 1–4) on the logger
as configured in HOBOware® software.
3. Insert the logger removal tool into the logger’s mounting loop from the bottom up so
that it hooks onto the mounting loop and the narrow end is pointed up.
4. Remove thermocouple wires from the attached spool and remove the spool from the
connector, if applicable. Holding the logger with one hand, feed the thermocouple
wires through the two ports in the side of the case. Insert the wires from channels 1
and 2 on the logger through the port on the left and the wires from channels 3 and 4
through the port on the right.
5. Place the logger in the case, attaching the magnetic side of the logger to the metal
plate. If you need to reposition the logger in the case, pull the logger out of the case
with the logger removal tool.
Thermocouple
wires fed
through port in
case
Onset’s NEMA 4X protective case is designed to offer a
weather-resistant enclosure to mount the HOBO UX120014M data logger in wet, dusty, or condensing environments
for short deployments where additional protection is needed.
Logger
removal tool
Grommet
assemblies
Mounting brackets
and screws (two
also on other side)
Logger in case with
logger removal tool
attached
1. Unscrew the dome nut from one of the two grommet assemblies.
Unscrew this
dome nut
Grommet end
2. Feed the wires on the side of the case through the grommet a
ssembly, O-ring side first.
Hand-tighten the grommet end of the assembly in the hole so that the O-ring is snug
against the protective case. Feed the wires through the dome nut and then handtighten it back on the assembly. Turn an additional quarter-turn with a wrench to
further tighten, but do not force.
Slide dome
nut onto
assembly and
hand-tighten
O-ring snug against case
3. Repeat steps 6 a
nd 7 with the other assembly and thermocouples. If there are no
thermocouples in the other port, then screw the dome plug into the open port so the
O-ring is snug against the case as shown below.
Dome plug in open port;
O-ring snug against case
4. Open the foil pouch containing the desiccant and place the de
siccant inside the case to
absorb/minimize internal condensation.
5. Close the lid on the case and mount it to a flat surface. The measurements to the
center of the mounting bracket holes are 6.6 cm (2.6 inches) wide (top to bottom on
both sides) and 13.89 cm (5.47 inches) long (left to right).
To read out the logger while it is in the case, open the lid and use the logger removal tool
to remove the logger. Connect the USB cable to the logger. Place the logger back in the
case with the logger removal tool attached when finished.
17423-B MAN-CASE-4X-2 © 2014 Onset Computer Corporation. All rights reserved. Onset, HOBO, and HOBOware are registered trademarks of