Onset H21, H22, U30, UX90, UX120 Specifications

Page 1
Minol Pulse Output Water Flowmeter Connection Instructions
r
For use with HOBO® H21, H22, U30, UX90, UX120, and RX3000 series data loggers
Applies to this Minol Flowmeter
Min. Cont. Max.
T-MINOL-130-NL Pulses representing 1
US gal/pulse
This document provides instructions on connecting the Minol Pulse Output Water Flowmeter listed above to HOBO H21, H22, U30, UX90, UX120, and RX3000 series data loggers.
Required
Minol Pulse Output Water Flowmeter listed above
HOBO H21, H22, U30, UX90, UX120, or RX3000 series data logger
Pulse input adapter S-UCD-M00x for H21, H22, U30, and RX3000 series or
RXW-UCD-xxx for RX3000 stations
22 AWG twisted pair wire (customer supplied) for UX120 series
Adapter cable CABLE-2.5-STEREO for UX90 series
®
HOBOware
software, version 2.2.1 or higher for H21, H22, or U12; 2.4.0 or higher for U30 series; 3.2 or higher for
UX120 series; 3.3 or higher for UX90 series
HOBOlink for RX3000 station
0.25 11.0 22.0 150 psi 90°C (194°F) Minomess 130
Minol Pulse Output Water Flowmeter
Connecting the Pulse Output Flowmeter to the Logger
H21, H22, U30, or RX3000 Connection
HOBO H21, H22, or U30 Series Data Logger
HOBO H21, H22, U30, or RX3000
Series Data Logger (H22-001 shown)
(H22-001 shown)
Connect to Smart
Note: Does not apply to
RXW-UCD-xxx motes
Sensor port
Connect either of the two pulse input adapter wires to either of the two wires
from the flowmeter (polarity not important) and then connect remaining two
wires to each other. Use appropriate termination for connections.
Connect to
Smart Sensor port
S-UCD-M00x
S-UCD-M00x or
RXW-UCD-xxx
Pulse Input Adapter
Pulse Input Adapter
Pulse Output Flowmete
© 2014–2021 Onset Computer Corporation. All rights reserved. Onset, HOBO, HOBOware, and HOBOlink are registered trademarks of Onset Computer Corporation. Other products and brand names may be trademarks or registered trademarks of their respective owners.
17911-E MAN-T-MINOL-130-NL
Page 2
Minol Pulse Output Water Flowmeter Connection Instructions
HOBO UX120 Series Data Logger
Customer-supplied
22 AWG twisted pair
UX120 Connection
Connect either the (+) or the ground ( ) terminal from the UX120 terminal block to either of the two wires from the flowmeter (polarity not important) and then connect
remaining two wires to each other. Use appropriate termination for connections.
Pulse Output Flowmeter
UX90-001/M Connection
HOBO UX90-001/M Data Logger
Data Interpretation:
Each pulse from the Minol flowmeter represents one US gallon. The data recorded in the logger will be the number of counts (pulses) per logging interval. For conversion to other units, the data must be exported from HOBO software (refer to the software documentation for details on exporting or sharing data).
Connect either the black or the white CABLE-2.5-STEREO wire (red wire not used) to
either of the two wires from the flowmeter (polarity not important) and then connect
remaining two wires to each other. Use appropriate termination for connections.
Pulse Output Flowmeter
CABLE-2.5-STEREO
Page 2 of 2