Quick Start for the InTemp
Connect
Connect
Connect
Mobile
Mobile
®
CX5000 Gateway
I am setting up a CX5000 gateway for automatic
download of CX loggers to the InTempConnect®
cloud.
Go to www.intempconnect.com to set up an
account or log into your existing account (A).
1
A
In InTempConnect, click Settings and then Roles.
2
Click Add Role (A) to create a role for the person
who will be setting up the gateway or click an
existing role to edit it.
A
Type the name of the role (A) for the Description.
Select “Login to InTempConnect” plus the gateway-
3
related privileges (Manage Gateways, Manage
Logger/Gateway Congs, Manage Shipments,
and Gateway Administrator) from the Available
Privileges list on the left and click the right arrow
button (B) to move them to the Assigned Privileges
list on the right. Select a user from the Available
Users list on the left and click the right arrow
button (C) to move the user to the Assigned Users
list on the right. Click Save (D).
A
B
Upload Data from the Logger
to the Cloud via the Gateway
Click Gateways and then Conguration Proles.
4
Click Add Conguration Prole and type a name (A)
for the conguration. Select the CX logger type. If
the gateway will be used in a storage application
(i.e. a clinic or oce), enter these settings (B):
• Select Download and Restart for when to
connect.
• Select “Immediately connect to a logger with
a new sensor alarm.”
• DO NOT select “Immediately connect to a
logger not seen by this gateway.”
• Choose to connect to loggers every week.
Click Save (C).
A
B
C
Tip: Refer to the full product manual for details on other
conguration settings. Go to www.onsetcomp.com/intemp/
resources/cx5000-manual.
D
Tip: If you need to add a user, click the Users tab and
then Add User, ll in the elds, and assign the user a role
with gateway privileges.
21853-F MAN-CX5000-QSG
Insert the appropriate plug for your region into
the AC adapter. Connect the AC adapter to the
5
C
gateway and plug it in. Wait a couple of minutes
for the gateway to completely power up. The
LED on the gateway will be yellow-green while it
powers up and then change to deep green once it
is ready to set up.
Set up Wi-Fi network
6
settings. Make sure the
device with the InTemp
app can connect to the
Wi-Fi network. Open
the app and log in as an
InTempConnect user (A).
Tip: If the gateway will be using Ethernet with DHCP, plug in the
Ethernet cable. Network settings will be congured automatically.
To congure network settings for Ethernet with static IP addresses
or to set up a gateway for use at another site, refer to the product
manual at www.onsetcomp.com/intemp/resources/cx5000-manual.
Tap Devices (B) and tap Gateways (C). The gateway
appears in the list. Tap anywhere in the row (D) to
connect to the gateway.
A
C
B
Devices
D
Tap Network Settings (E) and then tap WiFi (F).
E
F
Tap Use Current WiFi Network (G) and tap Save (H).
H
G
Connect to the gateway (see step 6) and tap
Congure (A).
7
(continued)
7
Select the gateway conguration (B) you created
in InTempconnect in step 4 (swipe left and right if
there are multiple congurations). Type a name for
the gateway deployment (C) and tap Start (D).
B
C
D
Once a gateway has contacted InTempConnect for
the rst time, a user is created for the gateway in
your account. Click Settings and then the Users tab
to see the gateway user name, which is listed as
CX5000-<gateway serial number>.
Deploy the gateway. Some guidelines when
8
selecting a location for the gateway:
• The gateway can support up to 50 loggers
within transmission range, which optimally
is 30.5 m (100 ft) will full line-of-sight.
• Test the range by positioning your mobile
device where you want to deploy the
gateway. If the mobile device can connect
to the logger with the InTemp app from
that location, then the gateway should be
able to connect to the logger as well.
• If you plan to use the gateway for loggers
in dierent rooms, be sure to test the
connection rst.
The gateway is ready for use with loggers. See
www.intempconnect.com/help for details on
conguring and downloading loggers with the
gateway, setting up shipments, and more.
A
1-800-LOGGERS (564-4377) • 508-759-9500
www.onsetcomp.com/support/contact
Refer to the CX5000 Gateway manual
for full product details, including
specications and mounting instructions.
Scan the code or go to www.onsetcomp.
com/intemp/resources/cx5000-manual.