Ono Sokki HR-6800, MP-5350 Instruction Manual

Digital Tachometer (For high speed)
HR-6800
Electromagnetic Detector
MP-5350
(The sensor is not included in a price of HR-6800
)
Instruction Manual (Basic Operations)
Warnings and Cautions In this document precautions are classified into two cat­egories: WARNING and CAUTION. This depends on the degree of danger or damage possible if the precaution is ignored and the product is used incorrectly.
1 Power switch
Turns the power ON or OFF.
2 Display
Displays the measurement value and various settings.
3 Input connector
Connected with the Detector with the supplied connection cable.
4 RECALL & ↑ switch
Used for memory call during measurement and numeri­cal input in the parameter setup mode.
5 MENU switch
Used to switch between the measurement mode and the parameter setup mode. The lock mode can be set and canceled by pressing this switch for 3 seconds or longer.
6 MEMORY & → switch
Used for memory writing during measurement and nu­merical digit shift in the parameter setup mode.
7 MODE & NEXT switch
Used for mode change during measurement and item selection in the parameter setup mode.
8 Indicator (input signal indicator)
When the detector circuit detects a rotational signal, the LED indicator lights up.
9 Type A/B selector switch
Used to select Type A or B.
0 Trigger level adjustment volume
Volume for adjusting the trigger level.
q Tripod mounting hole
Used to mount a tripod.
w Battery cover
e Connector cover
Cover for the power inlet and output connectors.
r DC power input
Input terminal for connecting the dedicated AC adapter. (when the dedicated AC adapter and dry batteries are used together, the AC adapter is given priority.)
t Analog output
Terminal for connection with a recorder, etc. through the optional AX-501 cord.
y Pulse output
Terminal for connection with an FFT analyzer, etc. through the optional AX-501 cord.
u CONDITION display
Displays the measurement mode, LOW battery, and errors.
i MAIN display
Displays measurement values, selections, settings, etc.
o SUB display
Displays memory addresses, settings, etc.
p UNIT display
Multiplies the measured value in the MAIN display by ten for readout in "r/min."
a Detecting element
Bring the detecting element at the end of the Detector close to the body of revolution under measurement.
s Output connector
Connected with the HR-6800 unit using the supplied connection cable.
1.Overview
The HR-6800 Digital Tachometer is a handy tachometer with built-in batteries integrating the measurement unit and dis­play unit. It is designed for measurement of bodies of revolu­tion for dental instruments, textile machines, and general­purpose high-speed machine tools, etc. With the use a dedicated Detector, the HR-6800 makes it possible to measure the rotational speed of the body of revo­lution under measurement. Up to 20 measurement data items can be stored in the HR­6800 unit using the memory function, which is useful for sub­sequent confirmation. The display unit displays the rotational speed (x10 r/min) with a 5-digit number. The equipment is provided with an analog output (inter­changeable with a monitor output) and a pulse output. The analog output is used for recording with a data recorder, etc., and the pulse output for tracking analysis with an FFT ana-
lyzer.
2.Features
Measurement from low to high rotational speeds (100 to
999,990 r/min)
High sensitivityMAX and MIN modes for displaying the maximum and
minimum values
Convenient memory function (up to 20 items can be
memorized) for confirmation of measurement results
Over mark function for indicating measurement values
exceeding a specified value
Analog output, sensor signal monitor output, and pulse
output
Type AAA batteries and AC adapter commonly usedBack light function which is convenient for use in dark
places
3.Measurement Principle
The Detector incorporates a permanent magnet and a de­tection coil to detect the rotational speed of an object under measurement based on the principle of electromagnetic in-
duction.
4.Unpacking
When you unpack the unit, make sure that you have all the following:
HR-6800
HR-6800 main unit.................................................. x1
Type AAA alkaline dry battery ................................ x4
Instruction manual ................ x2 (2 different manuals)
Carrying case ......................................................... x1
MI-0301 Tripod attachment adapter ........................ x1
MP-5350
(The sensor is not included in a price of HR-6800
)
Detector (MP-5350) ................................................ x1
Connection cable (1m) ........................................... x1
Overview
o
i
u
p
6 7
4
2
1
8
3
e
5
ANALOG PULSE
6V0.5
A
r t y
q
w
180.5
66
14
47.5
TRIG LEVEL
Type A B
9 0
189.5
10713
a
s
1 HR-6800 main unit Type AAA
alkaline dry batteries
3 Instruction manuals 4 Carrying case
H ig
h
-spe e d
T
a c
h o
m
e te
r
HR-6800
InstructionManual(FunctionReference)
Copyright © ONO SOKKI CO
.,L TD
.
2005 All r
i ghts reserv
ed.
T h
a n k
y o
u f o ry
o u rs
e le
cti o n o
fth
e H
R
-6 8
0 0 H
ig
h
-
s p ee
d T
a ch
o m
et er
.
T
o e n su
r e th
e
p e
rf o rm
a n
c e o
fth
e H R
-6
8 0
0 ,p
le ase
re a
d 
th ism
a n u a
lth
o ro
u g h
l y .
H ig
h
-sp e e
d T
a c
h o m
ete
r
HR-6800
E
le ctrom
a g
n e
tic
D e
te
c to r
MP-5350
InstructionManual(BasicOperations)
Copyright © ONO SOKKI CO
.,LTD
.
2005 All r
i ghts reserv
ed.
T h
a n k y
o u fo
ry
o u rse
le ctio
n o f
th e
H R
-6 8
0 0 H
ig
h
-
sp e
e d T
a c h
o m e
t e r.
T o
e n su
reth
e p
e rfo
rm
an c e
o fth
e H
R
-6 8 0
0 ,p le
a se
re
ad 
th ism
a n u a
lth
o r o u
g h ly
.
Tripod attachment adapter (MI-0301)
Name and Function of Each SectionObserve the Following Points before Use
CAUTION
Do not drop the equipment or apply excessive shock to
it. Since this equipment incorporates high-precision elec­tronic parts, be careful not to drop it or apply strong shock.
Wipe dirt off using a dry cloth or a cloth dampened with
neutral detergent and squeezed firmly. Do not use vola­tile oils (thinner or benzine) or alcohols.
Be sure to use the supplied connection cables.
Using cables other than the supplied one may make it impossible to obtain specified performance or, in the worst case, cause damage to the equipment.
Measurement in strong magnetic field or near an AC line
is not possible. Since this equipment has a high input sensitivity to en­able measurement with a minute signal, measurement in
strong magnetic field or near an AC line is not possible.
WARNING
Perform measurement using enough care with the target
under measurement rotating at high speeds. Be careful not to allow connection cables to be caught by rotating sections.
When using an AC adapter, be sure to use a dedicated
AC adapter (option). Using adapters other than the optional one may cause
failure.
Avoid using the equipment in places subject to rapid tem-
perature change. Do not move the equipment rapidly from a hot place to a cold one or vice versa. Condensation can form inside the unit which may cause failure.
Be careful not to get water, oil, dust, or foreign materials
inside the unit. Do not use the equipment in places where you may get water or oil or places which are humid or dusty.
1 MP-5350 Detector Connection cable
Copyright©ONOSOKKICO.,LTD. 2007Allrightsreserved.
Omission of Issuance of Certificate
This product has been tested under strict inspections for correct operation before shipment. Please note that the issuance of certificate is omitted.
Warranty
1. This product is covered by a warranty for a period of one year from the date of delivery.
2. This warranty covers free-of-charge repair during the warranty period for defects occurred while the product is used under correct operating conditions accordi ng to de­scriptions in this manual and notices on the unit label.
3. For free-of-charge repair during the warranty period, con­tact your dealer or your nearest Ono Sokki sales office nearby.
4. Even during the warranty period, the following failures will be handled on a fee basis. (a) Failures or damages occurring through misuse,
misoperation, repairing without ONO SOKKI’S ap­proval.
(b) Failures or damages occurring through mishandling
(dropping) during transportation after purchase.
(c) Failures or damages occurring by an Act of God (fires,
earthquakes, flooding, and lightening), environmen­tal disruption, or abnormal voltage.
(d) Replenishmen t of expendable supplies, spare par ts,
and accessories.
WARNING
CAUTION
Thissymbolisusedtoindicateprecautions wherethereisariskofdeathorserious personalinjurytotheoperatoriftheproductis
handledincorrectly. Thissymbolisusedtoindicateprecautions
wherethereisariskofsomepersonalinjury totheoperatororonlymaterialdamagetothe
productiftheproductishandledincorrectly.
This guarantee covers only the performance of the product itself only. All inconvenience by the trouble of this product is not included. *Outer appearance and specifications are subject to change without prior notice.
HOME PAGE: http://www.onosokki.co.jp/English/english.htm
WORLDWIDE
ONO SOKKI CO., LTD. 1-16-1 Hakusan, Midori-ku, Yokohama 226-8507, Japan Phone : 045-935-3976 Fax : 045-930-1906 E-mail : overseas@onosokki.co.jp
B00002033 / IM07062203(2) 081(MS)020
1.Power Supply
The HR-6800 operates on four Type AAA batteries or the dedicated AC adapter (option: PB-7080).
If the batteries are consumed and the LOW mark "
" appears, replace them with new ones. Be sure to replace
all the four batteries at the same time.
Battery replacement procedure
While pushing lightly the two (anti-slip) slots of the
battery cover with your finger, slide it to remove.
Put the batteries properly in the battery compartment
with the correct polarity (+/-).
Put the battery cover.
2.MI-0301 Tripod Attachment Adapter
With the use of the supplied tripod attachment adapter, the Detector can be installed using a commercially avail-
able tripod.
Attach the Detector to and detach it from the tripod attach­ment adapter as shown below.
1.Measurement Section
Objects under measurement: Bodies of revolution for dental in-
struments Bodies of revolution for textile ma­chines Bodies of revolution for high-speed machine tools, etc.
* The object under measurement needs
to be polarized. Operation method : Periodic operation method Measuring time : 50 ms + Input signal 10-period time
or less Input frequency range : 1.6 Hz to 16.666 kHz Measuring unit : 10 r/min (rotational speed) Measuring range : 100 to 999990 r/min (selectable)
Measurement accuracy : Display value x (±0.02 %) ±1 count Over range function : If the measurement value exceeds the
display range, over range " "
appears. Upper limit rotation warning function: If the rotational speed ex-
ceeds a preset upper limit, upper limit
warning " " appears.
Trigger adjustment function: Can be adjusted using the rotary
volume on the right-hand side face of
the HR-6800 unit.
2.Detecting Element
(The sensor is not included in a price of HR-6800
)
Detection method : Electromagnetic induction DC resistance : 25 to 40 Ω [20 ˚C] Operating temperature range: 0 ˚C to +40 ˚C Storage temperature range: -10 ˚C to +50 ˚C Resistance to vibration : 19.6 m/s
2
Resistance to shock : 490 m/s
2
Mass : About 50 g (detecting element only)
Dimensions : 107 x ø14 mm
3.Display Section
Number of display digits: 5 digits Character height : 10.2 mm Indicator : 7-segment LCD with back light
Refresh time : About 1 s/0.5 s selectable
4.Measurement Mode
MAX (peak hold) : Displays the maximum value during mea-
surement.
MIN (peak hold) : Displays the minimum value during mea-
surement. Others : Displays the current measurement value. Memory function : Up t o 20 measurement values can be
memorized each time the memory switch is
pressed. Since these values are stored in
non-volatile memory, they are retained even
after the power is turned OFF.
Specifications
5.Analog Output Section
REVO
Output contents : Output to the display value of rotational
speed.
Voltage range : 0 to F.S./0 to 1 V
(The full scale can be set with a setup
parameter.) Conversion method : 10-bit D/A conversion method Linearity : ± 1 % of F.S. Output refresh time : 50 ms + Input signal 10-period time or
less Temperature stability: ± 0.05 % of F.S./˚C (ZERO & SPAN) Setup error : ±0.5 % of F.S. (adjustment setup error
at the time of shipment, ZERO & SPAN) Load resistance : 100 k or more
Output connector : Super mini jack (ø2.5)
SIG
Output contents : Analog output for monitoring after wave-
form shaping of the sensor signal (be-
fore pulse waveform conversion) Load resistance : 100 k or more Output connector : Super mini jack (ø2.5/Commonly used
with REVO output)
6.Pulse Output Section
Output timing : Outputs one pulse for each signal de-
tection.
(For bodies of revolution with one out-
put per rotation, outputs one pulse per
rotation.) Output voltage : Hi level=4.5 V or higher
Lo level=0.5 V or lower Output logic : Positive logic pulse Load resistance : 100 k or more
Output connector : Super mini jack (ø2.5)
7.General Specifications
Power supply : Type AAA dry battery (x4) or dedi-
cated AC adapter (PB-7080)
Continuous operating time: About 13 hours (back light OFF)
About 8 hours (back light ON) (When alkaline batteries are used at
20 ˚C) Battery LOW display : Lights up at about 4.5 V. Operating temperature range: 0 ˚C to +40 ˚C Storage temperature range: -10 ˚C to +50 ˚C Operating humidity range: +35 to +85 %RH (without conden-
sation) Storage humidity range : +35 to +85 %RH (without conden-
sation) Mass : About 230 g (HR-6800 unit only, bat-
teries not included) Dimensions : 189.5 x 66.0 x 47.5 mm (HR-6800
unit)
Before Use
Battery polarity display
4.Measurement
Connect the HR-6800 unit with the Detector using the
supplied cable.
Select Type A or B using the Type selector switch on the
side face.
Slide the power switch to turn the power ON.Set the number of pulses per rotation (P/R) and other
parameters according to the object under measurement.
Bring the Detector close to the object under measurement.
Bring the end or its side face of the Detector to the body of revolution as shown below.
Detection at the end
Detection at side face of the end
During measurement, turn the trigger level adjustment
volume so that the indicator blinks stably and the rotational speed be displayed. Since the center value of the trigger level adjustment volume is 5, gradually increase or decrease the trigger level from 5 to adjust the trigger level.
Perform measurement.
TRIG LEVEL
5
Options Storage
The storage temperature range of the HR-6800 is -10˚C
to +50˚C. When you store it, avoid locations where the
temperature is extremely high or low or the humidity is
high. Store it in a place which is well-ventilated and not
exposed to direct sunlight. If you do not use it for a pro-
longed period of time, be sure to remove the batteries to
prevent accident caused by battery leakage, etc.
AX-501: Output cord
PB-7080: AC adapter
(IN: 100 to 120 VAC, OUT: 6 VDC)
Body of revolution under measurement
520 mm
3.Measurable Bodies of Revolution
The HR-6800 enables measurement of the following bodies
of revolution:
A body of revolution with a magnet embedded
Most stabilized measurement is possible.
This system is recommended for a drill for rotation test.
A body of revolution partially polarized
A magnet is rubbed on a part of the body of revolution for
polarization before measurement. If the magnetic force
weakens with time, polarization is performed again.
A body of revolution with a bumpy shape
Since a magnet is embedded in the Detector of the HR-
6800, whether a body of revolution can be measured
depends on its shape. However, depending on the material
and shape of the body of revolution, a detected signal may
become minute making detection of rotation difficult.
Therefore, if possible, magnet-based detection is
recommended.
Note:Since the Detector has frequency characteristics,
it needs strong magnetic force particularly when
measuring low rotational speed.
Refer to the following rough standard of magnetic
force:
100 r/min: 10 mT or more
10000 r/min: 5 mT or more
100000 r/min: 1 mT or more
Note:Measurement is not possible in places where
strong magnetic field is present around the mea-
suring point.
RANGE
Hi Lo
Type selection
A
B
10,000 to 999,990 r/min
100 to 50,000 r/min
200,000 to 999,990 r/min
Rotational speed range
* When the number of pulses is set to "1" * Generally, use Type A.
Attachment Detachment
10
520 mm
Applicable Standards
CE Marking
EN61326
EN61010-1
: This mark declares the compliance with
EC instructions.
Loading...