One Stop Systems OSS-PCIe-HIB2-x4-H, OSS-PCIe-HIB2-x4-T User Manual

PCIe x4 Host Cable Adapter (HIB2)
User Manual
OSS-PCIe-HIB2-x4-H (Host)
OSS-PCIe-HIB2-x4-T (Target)
2235 Enterprise Street, Suite 110 Escondido, CA 92029 Phone: (760) 745-9883 Fax: (760) 745-9824 www.onestopsystems.com
One Stop Systems, Inc. Host Cable Adapter User Manual Rev. A
Description
The Host Cable Adapter (Part # OSS-PCIe-HIB2-x4-H) allows communication between a processor and an I/O port. The OSS­PCIe-HIB2-x4-T is used as a target in a One Stop Systems 2 slot backplane (OSS-EBP-2000).
Slot Cover (also available in low profile height)
Power on / Cable Ready LEDs
PCIe
x4
Connector
Initial Set-Up
Unpacking Instructions
1. If the carton is damaged when you receive it, request that the carrier's agent be present when you unpack and inspect the equipment.
2. After unpacking, verify that all items listed in the packing list are present.
3. Inspect the equipment for shipping damage.
4. Save all packing material for storage or return shipment of the equipment.
5. For repairs or replacement of equipment damaged during shipment, contact One Stop Systems, Inc. to obtain a Return Materials Authorization (RMA) number and further shipping instructions.
3.35"
2.713"
2.713"
Installation and Removal
1. Power down the host system.
2. Open the chassis according to your system documentation.
3. Let the power supply cool down, if necessary.
4. Remove the Host Cable Adapter from the protective bag, observing proper ESD safety procedures.
Installing the Host Cable Adapter:
1. Insert the Host Cable Adapter into a PCIe x4, x8 or x16
tighten the screw.
1
Up-plugging” the Target Cable Adapter into a x8 or x16 slot is allowed, but the motherboard manufacture may limit the bandwidth to x1 (250MB/s)
speeds. If you need to do this, check with the motherboard manufacturer to see how up-plugging is handled on their motherboards. A PCIe x4 board will not physically fit in a x1 slot.
One Stop Systems, Inc. Host Cable Adapter User Manual Rev. A 2
1
add-in card slot. Make sure that the card is well seated and
2. Attach the cable by first pulling back on the retractor ring. With the keyed slot aligned with the connector key ridge on
the slot cover, insert the cable connector into the cable port connector on the board until the cable locks in place.
3. The connectors on either end of the PCIe x4 cable are identical. Each connector is equipped with a retractor to allow the connector to be locked into place.
Retractor on Cable Connector
4. Attach the other end of the cable to the upstream port connector of the ELB in the expansion enclosure. To link to a
Retractor ring
second expansion enclosure, connect a second cable from the downstream port connect or on the ELB of the first expansion enclosure to the upstream port connector on the ELB of the second enclosure.
Removing the Host Cable Adapter:
1. Remove the cable by pulling on the green retractor ring which releases the locking mechan ism.
2. Loosen and remove the screw before removing the Host Cable Adapter from the card slot.
Alignment grooves
Specifications
Electrical/Mechanical Specifications
Form Factor: x4 PCIe add-in card
Dimensions (H x L): 2.7 x 3.4 inches (68 x 86mm)
Front Panel Connectors: One PCIe x4 cable connector
Front Panel Indicators: Power On / Cable Present LEDs
Power Consumption (designed to meet the following conditions
3.75W typical, 3.3@1.3A
Operating Environment (designed to meet the following conditions)
Temperature Range: 0° to 50°C (32° to 122°F)
Relative Humidity: 10 to 90% non-condensing
Shock: 30g acceleration peak (11ms pulse)
Vibration: 5-17 Hz 0.5” double amplitude displacement; 7-2000Hz, 1.5g acceleration.
Redriver Pericom PI2EQX4402 Agency Compliance Designed to meet, but not tested
One Stop Systems, Inc. Host Cable Adapter User Manual Rev. A 3
UL60950, FCC Class B, CE safety and emissions
Switches
Switch SW1 Settings Switch SW2 Settings
Switch
#
1 ENABLE Down 2 RX_SEL0 Up
3 RX_SEL1 Up 4 RX_SEL2 Up 5 RX_SEL3 Up
6 RX_SEL4 Up 7 RX_SEL5 Up
8 RX_SEL6
Signal Name Default* Comments
Up
1 2 3 4 5 6 7 8
1
8
81
SW2 SW1
SW1 and SW2 Switch Location and Orientation
Up = Disable all Lanes Down = Normal operation
Rx Equalizer Selection See Table 1
Rx Amplifier Selection See Table 2
Rx De-Emphasis Selection See Table 3
ON, low, 0, Up
OFF, high, 1, Down
Switc
h #
1 N/C Not connected 2 TX_SEL0 Up 3 TX_SEL1 Up 4 TX_SEL2 Up 5 TX_SEL3 Down 6 TX_SEL4 Down 7 TX_SEL5 Up
8 TX_SEL6 Down
Signal
Name
Default* Comments
Tx Equalizer Selection See Table 1
Tx Amplifier Selection See Table 2
Tx De-Emphasis Selection See Table 3
Table 1 Table 2 Table 3
2 3 4 Equalization
0 0 0 No Equalization 0 0 1 1.5db @ 1.25 GHz 0 1 0 2.5db @ 1.25 GHz 0 1 1 3.5db @ 1.25 GHz 1 0 0 4.5db @ 1.25 GHz 1 0 1 5.5db @ 1.25 GHz 1 1 0 5.5db @ 1.25 GHz 1 1 1 7.5db @ 1.25 GHz
5 6 Swing
0 0 1x 0 1 0.8x 1 0 1.2x 1 1 1.4x
One Stop Systems, Inc. Host Cable Adapter User Manual Rev. A 4
7 8 De-emphasis
0 0 0db 0 1 -2.5db 1 0 -3.5db 1 1 -4.5db
LEDs
Power and
Cable present
LEDs
PCIe Lane Status LEDs
CR2 CR4 CR6 CR8
CR3 CR5 CR7 CR9
LED # Function
CR2 Tx pair, Lane 0 (from card edge) CR3 Rx pair, Lane 0 (from cable) CR4 Tx pair, Lane 1 (from card edge) CR5 Rx pair, Lane 1 (from cable) CR6 Tx pair, Lane 2 (from card edge) CR7 Rx pair, Lane 3 (from cable) CR8 Tx pair, Lane 3 (from card edge) CR9 Rx pair, Lane 2 (from cable)
LED
Power LED Cable present
Block Diagram
Downstream
x4 PCI Express
Cable Connector
One Stop Systems, Inc. Host Cable Adapter User Manual Rev. A 5
Clock* Clock*
LVPECL
Clock Buffer
PCIe Signal
x4 PCIe Tx x4 PCIe Tx
Redriver
x4 PCIe Rx x4 PCIe Rx
PCIe Signal
Redriver
CPRSNT#
LEDs
Cable Present/ Pwr
LEDs
PCIe lane status
*Clock direction shown in Host configuration
+3.3v
Upstream
x4 PCI Express
Card Edge Connector
Connectors
PCIe x4 Card Edge Connector
The pins are numbered as shown with side A on the top of the centerline on the solder side of the board and sid e B on the bottom of the centerline on the component side of the board.
The PCIe interface pins PETpx, PETnx, PERpx, and PERnx are named with the following convention: “PE” stands for PCIe high speed, “T” for Transmitter, “R” for Receiver, “p” for positive (+), and “n” for negative (-).
Note that adjacent differential pairs are separated by two ground pins to manage the connector crosstal k.
Pin-out for the PCIe x4 Card Edge Connector on the Host Cable Adapter
Pin #
1 N/C N/C PRSNT1# Hot-Plug presence detect 2 N/C N/C N/C N/C 3 N/C N/C N/C N/C 4 GND Ground GND Ground 5 NC N/C N/C Not connected 6 N/C N/C JTAG3 TDI (Test Data Input) 7 GND Ground JTAG4 TDO (Test Data Output) 8 +3.3V 3.3 V power N/C Not connected 9 N/C Not connected N/C Not connected 10 3.3Vaux 3.3 V auxiliary power +3.3V 3.3 V power 11 N/C N/C PERST# Fundamental reset
12 RSVD Reserved GND Ground 13 GND Ground REFCLK+ 14 PETp0 15 PETn0 GND Ground 16 GND Ground PERp0 17 PRSNT2# Hot-Plug presence detect PERn0 18 GND Ground GND Ground 19 PETp1 20 PETn1 GND Ground 21 GND Ground PERp1 22 GND Ground PERn1 23 PETp2 24 PETn2 GND Ground 25 GND Ground PERp2 26 GND Ground PERn2 27 PETp3 28 PETn3 GND Ground 29 GND Ground PERp3 30 RSVD Reserved PERn3 31 PRSNT2# Hot-Plug presence detect GND Ground 32 GND Ground RSVD Reserved
Side B Side A Name Description Name Description
Mechanical key
Reference clock (differential pair)
Receiver differential pair, Lane 0
Receiver differential pair, Lane 1
Receiver differential pair, Lane 2
Receiver differential pair, Lane 3
Transmitter differential pair, Lane 0
Transmitter differential pair, Lane 1
Transmitter differential pair, Lane 2
Transmitter differential pair, Lane 3
REFCLK
RSVD Reserved
GND Ground
GND Ground
One Stop Systems, Inc. Host Cable Adapter User Manual Rev. A 6
A
PCI Express x4 Cable Connector
The PCI Express x4 connector is a 38 position edge card connector with metallic shell as defined in the PCI Express External Cabling Rev 1.0, Molex part number 75586-0010, or equivalent. On the x4 connector, the pins are recessed far back inside the EMI Housing Guide (metallic shell) and are not easily accessed.
PCI Express x4 Connector Pin Assignment
Row B, Pin 19
Row A, Pin 1
Row
Pin
Signal Name
#
1 GND GND 1 2 PET0+ PER0+ 2
3 PET0- PER0- 3 4 GND GND 4 5 N/C N/C 5 6 N/C N/C 6 7 GND GND 7 8 N/C N/C 8 9 N/C N/C 9 10 GND GND 10 11 N/C N/C 11 12 N/C N/C 12 13 GND GND 13 14 CREFCLK+ 3.3V 14 15 CREFCLK- 3.3V 15 16 GND GND 16 17 GND GND 17 18 CPRSNT# CWAKE# 18 19 CPWRON CPERST# 19
Row B
Signal Name Pin
#
OSS-EBP-2000 Backplane
One Stop Systems, Inc. Host Cable Adapter User Manual Rev. A 7
The OSS-EBP-2000 has two PCI Express x8 link slots connected together. One slot supports the OSS-PCIe-HIB2-x4-T that brings a remote PCIe bus to the backplane via a cable interface. Any x8, x4, or x1 IO PCIe add-in board can be installed in the second slot and operate as a remote slot from the host PC. For example, the One Stop Systems quad USB board can be installed in the second slot allowing four USB devices to be operated from the remote computer
.
Limited Warranty
One Stop Systems warrants this product to be free of defects in material and workmanship for an initial period of two years from date of delivery to the original purchaser from One Stop Systems. During this period, One Stop Systems will, at its option, repair or replace this product at no additional charge to the purchaser, except as set forth in this warranty agreement. One Stop Systems will, at its option, repair or replace this product at no additional charge to the purchaser, if the defect is related to the One Stop Systems manufactured product, such as a power supply, backplane, other chassis components or CPUs. One Stop Systems is not liable for any defects in material or workmanship of any peripherals, products or parts, which One Stop Systems does not design or manufacture. However, One Stop Systems will honor the original manufacturer’s warrant y on thes e products. One Stop Systems will analyze the defective component and the customer will be charged in the foll owing instances:
No problem found: $75 (U.S. dollars).
Damage: Parts and labor at $75 per hour with a $100 minimum charge (U.S. dollars). Receipt of damaged goods voids the
One Stop Systems warranty.
Repair parts and replacement products will be furnished on an exchange basis and will be either new or reconditioned. All replacement parts and products shall become the property of One Stop Systems, if such parts or products are provided under this warranty agreement. In the event a defect is not related to the One Stop Systems manufactured product, One Stop Systems shall repair or replace the defective parts at the purchaser’s cost and deliver the defective parts to the purchaser. This limited warranty shall not apply if the product has been misused, carelessly handled, defaced, modified or altered, or if unauthorized repairs have been attempted by others. The above warranty i s the only warranty authorized by One Stop Systems and is in lieu of any implied warranties, including implied warranty of merchantability and fitness for a particular purpose. In no event will One Stop Systems be liable for any such damage as lost business, lost profits, lost savings, downtime or delay, labor, repair or material cost, injury to person or property or any similar or dissimilar consequential loss or damag e incurred by the purchaser, even if One Stop Systems has been advised of the possibility of such losses or damages. In order to obtain warranty service, the product must be delivered to the One Stop Systems facility, or to an authorized One Stop Systems service representative, with all included parts and accessories as originall y shipped, along with the proof of purchase and a Returned Merchandise Authorization (RMA) number. The RMA number is obtained, in advance, from One Stop Systems Customer Service Department and is valid for 30 days. The RMA number must be clearly marked on the exterior of the original shipping container or equivalent. Purchaser will be responsible and liable for any missing or damaged parts. Purchaser agrees to pay for shipping charges one way, an d to either insure the product or assume the liability for loss or damage during transit. Ship to:
One Stop Systems ATTENTION: RMA REPAIR DEPARTMENT RMA #### 2235 Enterprise Street, Suite 110 Escondido, CA 92029
www.onestopsystems.com
2235 Enterprise Street, Suite 110 y Escondido, CA 92029 y Tel (760) 745-9883 y Fax (760) 745-9824
One Stop Systems, Inc. Host Cable Adapter User Manual Rev. A 8
Loading...