All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any
form, or by any means, mechanical, electronic, photocopying, recording, or otherwise, without the prior written
permission of OMRON.
No patent liability is assumed with respect to the use of the information contained herein. Moreover, because OMRON
is constantly striving to improve its high-quality products, the information contained in this manual is subject to change
without notice. Every precaution has been taken in the preparation of this manual. Nevertheless, OMRON assumes no
responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the
information contained in this publication.
Introduction
Thank you for purchasing a G5-series Servo Drive. This manual explains how to install and wire the
Servo Drive, set parameters needed to operate the Servo Drive, an d remedies to be taken and
inspection methods to be used in case that problems occur.
Intended Readers
This manual is intended for the following individuals.
Those who have electrical knowledge (certified electricians or individuals who have equivalent
knowledge) and also are qualified for one of the following:
• Introducing FA equipment
• Designing FA systems
• Managing FA sites
Introduction
Notice
This manual contains information you need to know to correctly use the Servo Drive and peripheral
equipment.
Before using the Servo Drive, read this manual and gain a full understanding of the information
provided herein.
After you finished reading this manual, keep it in a convenient place so that it can be referenced at any
time.
Make sure this manual is delivered to the end user.
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
1
Manual Configuration
Manual Configuration
This manual consists of the following sections.
Section 1Features and
System
Configuration
Section 2Models and
External
Dimensions
Section 3SpecificationsThis section provides the general specifications, characteristics,
Section 4System DesignThis section explains the installation conditions, wiring methods which
Section 5EtherCAT
Communications
Section 6Basic Control
Functions
Section 7Applied FunctionsThis section outlines the applied functions such as the electronic gear
Section 8Safety FunctionThis function stops the motor based on a signal from a safety controller
Section 9Servo Parameter
Objects
Section 10OperationThis section explains the operating procedures and how to operate in
Section 11Adjustment
Functions
Section 12Troubleshooting
and Maintenance
AppendicesThe appendices provide the explanation for the profile that is used to
This section explains the features of the Servo Drive and name of each
part.
This section explains the models of Servo Drive, Linear Motors, and
peripheral devices, and provides the external dime nsions and mounting
dimensions.
connector specifications, I/O circuits of the Servo Drives and Linear
Motors, as well as specifications of other peripheral devices.
include wiring conforming to EMC directives, and regenerative energy
calculation methods for the Servo Drive and Linear Motor, and also
describes the performance of External Regeneration Resistors.
This section describes EtherCAT communications under the assumption that
the G5-series Servo Drive is connected to the Machine Automation Controller
NJ-series (Model: NJ301(Model: CJ1W-NC281/NC481/NC881/NCF81/NC482/NC882/NCF82).
This section outlines basic control functions, and explains the settings.
and gain switching, and explains the settings.
or safety sensor. An outline of the function is given together with
operation and connection examples.
This section explains the settings of each object.
each mode.
This section explains the functions, setting methods, and items to note
regarding various gain adjustments.
This section describes the items to check when problems occur,
troubleshooting using the error displays, troubleshooting based on the
operating conditions, and periodic maintenance.
control the Servo Drive, lists of objects, Sysmac error status codes, and
other information.
Outline
/NJ501-
) or Position Control Unit
2
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
Manual Structure
11 Adjustment Functions
11-26
11-8 Disturbance Observer Function
You can use the disturbance force value estimated with the disturbance observer to lower the effect of
the disturbance force and reduce vibration.
The disturbance observer function can be used in the following situations.
Precautions for Correct UsePrecautions for Correct Use
The disturbance observer function may not work properly under the c onditions described in the
following table.
11-8-1 Operating Conditions
Conditions
Operating mode Position control Mode, speed control
Others• When Servo is ON.
• When elements other than control parameters, such as the force limit, are set correctly
and there is no trouble with the motor's normal (The setting of 3002 hex is “0”.).
• When realtime a utotuning function is disabled operation.
•
When instantaneous speed observer function is disabled (The setting of 361 0 he x bi t 0 is “0”.).
progress.
• Dis turbance obse rver operation is disabled wh en magnetic pole position estimation is in
Conditions under which the adaptive filter does not operate properly
Load condition • If there is a resonance point below the cut-off frequency estimated by the distur-
bance observer
• If a large amount of high-frequency elements is found in the disturbance force
• If the the external encoder resolution is low
Motor+load
+
−
Load model
+ −
Filter
Gain
+
+
Disturbance observer
Add to the
direction that
negates the
disturbance
Setting with
3623 hex
Set with 3624 hex
Disturbance force
Estimation value
Disturbance force
Force command
Internal force command
Motor Speed
G5 Series AC ServoDrives With Built-in EtherCAT Communications, Linear Motor Type
11-27
11 Adjustment Functions
revresbO ecnabrutsiD 8-11
noitcnuF
11
sgnitteS gniriuqeR stcejbO
2-8-11
1
Set the Function Expansion Setting (3610 hex).
Set whether to enable or disable the disturbance observer in bit 1.
0: Disabled
1: Enabled
Set the operating conditions for enabling the function in bit 2.
0: Enabled at all time
1: Enabled only when gain 1 is selected
2
Set the Disturbance Observer Filter Setting (3624 hex).
Set a small value for the Disturbance Force Compensation Gain (3623 hex). Change the value
in the Disturbance Observer Filter Setting (3624 hex) from a large value gradually to a smaller
one. The smaller the value set in the Disturbance Observer Filter Setting (3624 he x) , t he l e s s
the lag you will have during disturbance force estimation. This has advantages in effectively
controlling the influence of disturbance, but results in a large operation noise. Consider the
balance between the advantage and disadvantage when setting this value.
3
Set the Disturbance Torque Compensation Gain (3623 hex).
After you set the Disturbance Observer Filter Setting (3624 hex), increase the value of the
Disturbance Force Compensation Gain (3623 hex) from a small value to a large value. The
larger the value set on the Disturbance Torque Compensation Gain (3623 hex) is, the more
effective control over the disturbance influence can be obtained. But the larger the value is, the
larger the operation noise will be. Set this object in combination with the Disturbance Observer
Filter Setting (3624 hex) to achieve balanced settings.
11-8-2 Objects Requiring Settings
IndexNameDescriptionReference
3610 hex Function Expansion SettingsSet the bits related to the disturbance observer.page 9-44
3623 hex Disturbance Force Compensation
Gain
Set the compensation gain for disturbance force.page 9-46
3624 hex Disturbance Observer Filter Setting Set the filter time constant for disturbance force
compensation.
page 9-46
11-8-3 Operating Procedure
G5 Series AC ServoDrives With Built-in EtherCAT Communications, Linear Motor Type
Level 2 heading
Level 3 heading
Level 1 heading
Manual Name
Level 2 heading
Section Number of
Level 1 heading
Level 3 heading
Shows which section
the content of the current
page belongs to.
Shows which sub-section
the content of the current
page belongs to.
Shows which paragraph
the content of the current
page belongs to.
Note, Supplementary
Information, Reference Target
A note, supplementary
information, reference target,
etc. are provided with
difference icons.
Operation Steps
Describes
the operation steps.
Page Structure and Symbol Icons
The following page structure and symbol icons are used in this manual.
Manual Structure
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
Note The above page is only a sample for illustrative purposes. It is not the actual content of the manual.
3
Manual Structure
Precautions for Safe Use
Precautions for Correct UsePrecautions for Correct Use
Additional Information
Special Information
Special information in this manual is classified as follows:
Precautions on what to do and what not to do to ensure safe usage of the product.
Precautions on what to do and what not to do to ensure proper operation an d performance.
Additional information to read as required.
This information is provided to increase understanding or make operation easier.
Terms and Expressions Used for the Linear Motor
In this manual, the term “Linear Motor” is defined as an OMRON product that consists of a Motor Coil
Unit (the coil on the primary side) and a Magnet Track (the magnets on the secondary side).
In addition to these components, constr u ctin g a Lin ea r Mot or syste m also requires the following parts,
which are built into a component called the “Linear Slider.”
• Motor Coil Unit (the coil on the primary side)
• Magnet Track (the magnets on the secondary side)
• External encoder
• Linear guide
• Chassis
*1 Not available from OMRON.
*1
Because a Linear Motor provides a linear movement, terms or expressions different from rotary motors
are used.
Example
RotaryLinear
Torque [N·m]Force [N]
Rotation speed [r/min]Speed [mm/s]
Inertia [kg·m
*1
*1
2
]Mass [kg]
2
However, for object names with respect to the CiA 402 Drive Profile and the terms used for the Safe
Torque OFF (STO) function, the manual uses the word “torque” for conformance with the relevant
standards.
Read “torque” as “force” when using these object names.
4
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
1
10
2
11
3
12
4A
5
6
7
8
9
1
10
2
11
3
12
4A
5I
6
7
8
9
Features and System
Configuration
Operation
Models and External
Dimensions
Adjustment Functions
Specifications
Troubleshooting and
Maintenance
System DesignAppendices
I
Index
EtherCAT
Communications
Basic Control Functions
Applied Functions
Safety Function
Servo Parameter Objects
Sections in this Manual
Sections in this Manual
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
11
Terms and Conditions Agreement
Terms and Conditions Agreement
Warranty, Limitations of Liability
Warranties
z Exclusive Warranty
Omron’s exclusive warranty is that the Products will be free from defects in materials and
workmanship for a period of twelve months from the date of sale by Omron (or such other period
expressed in writing by Omron). Omron disclaims all other warranties, express or implied.
z Limitations
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF
THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based
on infringement by the Products or otherwise of any intellectual property right.
z Buyer Remedy
Omron’s sole obligation hereunder shall be, at Omron’s electi on, to (i) replace (in the form origin ally
shipped with Buyer responsible for labor charges for removal or replacement thereof) the
non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an
amount equal to the purchase price of the non-complying Product; provided that in no event shall
Omron be responsible for warranty, repair, indemnity or any other claims or expenses rega rding the
Products unless Omron’s analysis confirms that the Products were properly handled, stored,
installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before
shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from
the use of Products in combination with any electrical or electronic components, circuits, system
assemblies or any other materials or substances or environments. Any advice, recommendations or
information given orally or in writing, are not to be construed as an amendment or addition to the
above warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN
ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN
CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on
which liability is asserted.
12
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
Application Considerations
Suitability of Use
Omron Companies shall not be responsible for conformity with any standards, codes or regulations
which apply to the combination of the Product in the Buyer’s application or use of the Product. At
Buyer’s request, Omron will provide applicable third party certification documents identifying ratings
and limitations of use which apply to the Product. This information by itself is not sufficient for a
complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness
of the particular Product with respect to Buyer’s application, product or system. Buyer shall take
application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR
PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO
ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
Terms and Conditions Agreement
Programmable Products
Omron Companies shall not be responsible for the user’s programming of a programmable Product,
or any consequence thereof.
Disclaimers
Performance Data
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for
the user in determining suitability and does not constitute a warranty. It may represent the result of
Omron’s test conditions, and the user must correlate it to actual application requirements. Actual
performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications
Product specifications and accessories may be changed at any time b ased on improve ments and other
reasons. It is our practice to change part numbers when published ratings or features are changed, or
when significant construction changes are made. However, some specifications of the Product may be
changed without any notice. When in doubt, special part numbers may be assigned to fix or establish
key specifications for your application. Please consult with your Omron’s representative at any time to
confirm actual specifications of purchased Product.
Errors and Omissions
Information presented by Omron Companies has been checked and is believed to be accurate;
however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions.
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
13
Safety Precautions
Indicates a potentially hazardous situation which,
if not avoided, may result in minor or moderate
injury, or property damage.
Indicates a potentially hazardous situation which, if
not avoided, could result in death or serious injury.
Additionally, there may be severe property damage.
DANGER
Caution
Safety Precautions
To ensure that the G5-series Servo Drive and Servomotor as well as peripheral equipment are used safely
and correctly, be sure to read this Safety Precautions section and the main text before using the product.
Learn all items you should know before use, regarding the equipment as well as the required safety
information and precautions.
Make an arrangement so that this manual also gets to the end user of this product.
After reading this manual, keep it in a convenient place so that it can be referenced at any time.
Definition of Precautionary Information
The following notation is used in this manual to provide precautions required to ensure safe usage of
G5-series Servo Drives and Servomotors.
The safety precautions that are provided are extremely important to safety. Always read and heed the
information provided in all safety precautions.
The display of precautions used in this manual and their meanings are explained below.
Explanation of Symbols
This symbol indicates a prohibited item.
The specific instruction is indicated using an illustration inside and text.
The symbol shown to the left indicates “disassembly prohibited.”
This symbol indicates a compulsory item.
The specific instruction is indicated using an illustration inside and text.
The symbol shown to the left indicates “grounding required.”
14
This symbol indicates danger and caution.
The specific instruction is indicated using an illustration insideand text.
The symbol shown to the left indicates “beware of electric shock.”
This symbol indicates danger and caution.
The specific instruction is indicated using an illustration inside
The symbol shown to the left indicates the “risk of hot surface.”
This symbol indicates danger and caution.
The specific instruction is indicated using an illustration inside and text.
The symbol shown to the left indicates the “risk of fire.”
This symbol indicates danger and caution.
The specific instruction is indicated using an illustration inside
The symbol shown to the left indicates a “general precaution.”
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
and text.
and text.
Precautions for Safe Use of This Product
DANGER
• Illustrations contained in this manual sometimes depict conditions without covers and safety shields
for the purpose of showing the details.
When using this product, be sure to install the covers and shields as specified and use the product
according to this manual.
• If the product has been stored for an extended period of time, contact your OMRON sales
representative.
Be sure to ground the frame ground terminals and ground wires for the Servo Drive and
Motor with 100 VAC or 200 VAC to 100 Ω or less, and for the Servo Drive and Motor with
400 VAC to 10 Ω or less.
Electric shock may result.
Never touch the parts inside the Servo Drive or the cable ends of the Motor Coil Unit.
Electric shock may result.
Safety Precautions
Do not remove the front cover, terminal covers, cables, or optional items while the power is
being supplied.
Doing so may result in electric shock.
Installation, operation and maintenance or inspection by unauthorized personnel is
prohibited.
Electric shock or injury may result.
Before carrying out wiring or inspection, turn OFF the main circuit power and wait for at
least 15 minutes.
Electric shock may result.
Install the Servo Drive and Motor before wiring.
Improper grounding may result in electrical shock.
Do not damage, pull, or put excessive stress or heavy objects on the cables.
Doing so may cause electric shock, malfunction, or burning.
Do not use the cable when it is laying in oil or water.
Electric shock, injury, or fire may result.
Do not perform wiring or any operation with wet hands.
Electric shock, injury, or fire may result.
Do not touch the Servo Drive radiator, Regeneration Resistor, or Motor while the power is
supplied or for a while after the power is turned OFF becuse they get hot.
Fire or a burn injury may result.
Use the Motor and Servo Drive in a specified combination.
Fire or equipment damage may result.
Never connect a power supply directly to the Motor.
Fire or failure may result.
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
15
Safety Precautions
Do not enter the operating area during operation.
Injury may result.
Never modify the Servo Drive.
Injury or equipment damage may result.
Install a stopping device on the machine to ensure safety.
* The holding brake is not a stopping device to ensure safety.
Injury may result.
Install an immediate stop device externally to the machine so that the operation can be
stopped and the power supply is cut off immediately.
Injury may result.
When the power is restored after a momentary power interruption, the machine may restart
suddenly. Never come close to the machine when restoring power.
* Implement measures to ensure safety of people nearby even when the machine is
restarted.
Injury may result.
After an earthquake, be sure to conduct safety checks.
Electric shock, injury, or fire may result.
Never drive the Motor using an external drive source.
Fire may result.
Do not place flammable materials near the Motor, Servo Drive, or Regeneration Resistor.
Fire may result.
Install the Motor, Servo Drive, and Regeneration Resistor on non-flammable materials such
as metals.
Fire may result.
When constructing a system that includes safety functions, be sure you understand the
relevant safety standards and all related information in user documentation, and design the
system to comply with the standards.
Not doing so may result in injury or equipment damage.
If the motor is not controlled, it may not be possible to maintain the stop.
To ensure safety, install a stop device. Risk of equipment damage and human injury.
Do not handle objects made of magnetic materials ne ar the Linear Motor. Use nonmagnetic
tools when performing installation or other work on the Linear Moto r.
The objects may be attracted by the magnetic field of the Linear Motor and you may be
caught between the motor parts, resulting in injury.
People using a pacemaker or other electronic medical device must stay away from the
linear motor.
A powerful magnetic field is generated by the stator and powered needle.
This may cause malfunctioning of electronic devices.
When shipping or transporting the Magnet Track, be sure to display that the content is a
strong magnetic product.
Medical electronics such as cardiac pacemakers may malfunction or injury may result.
Do not put the product into the fire.
Burst or gas may occur and injury may result.
16
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
Safety Precautions
Caution
Do not store or install the Servo Drive in the following locations:
• Location subject to direct sunlight
• Location where the ambient temperature exceeds the specified level
• Location where the relative humidity exceeds the specified level
• Location subject to condensation due to rapid temperature changes
• Location subject to corrosive or flammable gases
• Location subject to high levels of dust, salt content, or iron dust
• Location subject to splashes of water, oil, chemicals, etc.
• Location where the Servo Drive may receive vib ration or impact directly
Installing or storing the Servo Drive in these locations may result in fire, electric shock, or
equipment damage.
The magnetic attraction force always affects between the Motor Coil Unit and Magnet Track
even when the power supply is turned OFF. Design a machine which supports the
magnetic attraction force and provides enough rigidity to maintain the accuracy.
Malfunction or failure may result.
Design a machine with consideration of the magnetic attraction force.
Malfunction or failure may result.
Do not hit the Motor Coil Unit against the stopper. Design the configuration so that the table
mounted on the Motor Coil Unit hits against the stopper.
Equipment damage may result.
Do not apply strong impact on the product.
Failure may result.
Prevent adhesion of foreign objects to the product.
Malfunction may result.
You cannot use the Linear Motor because its magnetic pole cannot be detected in an
unbalanced load such as vertical axis.
If the magnetic pole cannot be detected, an error may occur and the Linear Motor may be in
the free-run status.
Injury or equipment damage may result.
The protective structure of the Linear Motor is IP00. Take necessary measures to prevent
dust, oil, etc.
Failure may result.
Ensure that the Linear Slider has a sufficient rigidity.
Equipment damage or malfunction may result.
Provide appropriate safety measures to prevent crashes, etc. if you design a system which
cooperates multiple motor coil units such as multi-head or tandem.
Equipment damage may result.
Do not bring electronic devices, magnetic recording media, or other articles that may be
affected by magnetism (clocks, computers, measuring instruments, magnetic cards, IC
cards, etc.) near the linear motor.
This may cause malfunctioning or equipment damage.
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
17
Safety Precautions
Storage and Transportation
When transporting the Motor Coil Unit, do not hold the cable.
Injury or equipment damage may result.
When transporting the Magnet Track, do not hold the cover to protect the magnet.
Injury or equipment damage may result.
Do not overload the product. (Follow the instructions on the product label.)
Injury or failure may result.
Be sure to store the product as packed in the same packing as delivered.
Injury or equipment damage may result.
Caution
When transporting or storing the magnet track, pack the product in the same condition as
delivered or cover the magnetic side by 30 mm or more thick material such as high density
plastics. (Be sure to provide more than 60 mm of thickness.)
Equipment damage may result.
The magnetic body (Motor Coil Unit, other Magnet Track or tools) generates attractive force
by Magnet Track. Be careful about the ambient environment when and after disassembling
the Linear Motor, and handling the Magnet Track.
Injury such as getting one’s hand caught in the Linear Motor or equipment damage may
result.
When lifting a 15 kW or higher Servo Drive du ring moving or installation, always have two
people lift the product by grasping a metal part.
Do not grasp a plastic part.
Injury or failure may result.
18
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
Installation and Wiring
Caution
Provide the specified clearance between the Servo Drive and the inner surface of the
control panel or other equipment.
Fire or failure may result.
Use crimp terminals to wire screw type terminal blocks. Do not connect bare stranded wires
directly to terminals blocks.
Fire may result.
Provide safety measures, such as a breaker, to protect against short circuiting of external
wiring.
Fire may result.
Do not step on the Servo Drive or place heavy articles on it.
Injury may result.
Safety Precautions
Be sure to observe the mounting direction.
Failure may result.
Wire the cables correctly and securely.
Runaway motor, injury, or failure may result.
Tighten the mounting screws, terminal block screws, and cable screws for the product to
the specified torque.
Failure may result.
Use non-magnetic mounting screws. Note also that the depth of any mounted screw is less
than the effective thread depth.
Equipment damage may result.
Be sure to wire the motor coil unit cable fixedly.
Equipment damage may result.
For wiring between the Motor Coil Unit cable and the Servo Drive, use a robot cable.
Equipment damage may result.
Be sure to securely fix the Linear Motor to the machine.
The Linear Motor may come off during operation and equipment damage may result.
When installing the Linear Motor, match the center of gravity of the motor coil unit and load.
Malfunction or equipment damage may result by the increase of the running loa d.
Install linear guides with great caution to comply with the gap specification of the motor coil
unit and magnet track. (If the gap is small, the running load by the friction will increase in
proportion to the magnetic attraction force.)
Malfunction may result.
Do not allow foreign objects to enter between the Motor Coil Unit and Magnet Track.
Equipment damage or malfunction may result.
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
19
Safety Precautions
Set a parameter to operate the Motor and external encoder in the same direction.
Malfunction or equipment damage may result.
When installing more than one Magnet Track, set the mounting screw accumulative pitch
tolerance within ± 0.2 mm.
Malfunction may result.
Use the specified screws for the tap holes of Motor Coil Unit. The tap holes are used to
install the Motor Coil Unit.
Equipment damage may result.
Use all tap holes of Motor Coil Unit and threaded holes of Magnet Track to install the Linear
Motor.
Equipment damage may result.
Always use the power supply voltage specified in the User’s Manual.
An incorrect voltage may result in malfunction or burning.
Take appropriate measures to ensure that the specified power with the rated voltage is
supplied.
Be particularly careful in locations where the power supply is unstable.
An incorrect power supply may result in failure.
Connect the Servo Drive to the Motor without a contactor, etc.
Malfunction or equipment damage may result.
Take appropriate and sufficient countermeasures to provide shielding when installing
systems in the following locations.
Not doing so may result in failure.
• Locati ons subject to static electricity or other forms of noise.
• Locati ons subject to strong electromagnetic fields and magnetic fields.
• Locati ons subject to possible exposure to radioactivity.
• Locati ons close to power supplies.
Do not use the Linear Motor in the location sub j ect to magnetic powders such as iron
filings.
They may adhere to the Linear Motor and failure may result.
Connect an emergency stop (immediate stop) relay in series with the brake control relay.
Injury or failure may result.
20
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
Operation and Adjustment
Caution
If the Servo Drive fails, cut off the power supply to the Servo Drive.
Fire may result.
Do not block the intake or exhaust openings.
Do not allow foreign objects to enter the Servo Drive.
Fire may result.
Conduct a test operation after confirming that the equipment is not affected.
Equipment damage may result.
Check any newly set parameters and software switch settings for proper execution before
actually using them.
Not doing so may result in equipment damage.
Never adjust or set parameters to extreme values, because it will make the operation
unstable.
Injury may result.
Separate the Motor from the mechanical system and check its operation before installing
the Motor to the machine.
Injury may result.
If the magnetic body is near the Linear Motor, the cogging will occur and affect the
performance.
Malfunction or equipment damage may result.
If an error occurs, remove the cause of the error and ensure safety, and then reset the
alarm and restart the operation.
Injury may result.
Do not operate the Motor connected to an excessive load mass.
Failure may result.
Safety Precautions
Do not turn ON and OFF the main Servo Drive power supply frequently.
Failure may result.
Install equipment to prevent crash and reduce shock.
Crash against the stroke edge may occur depending on stopping distance and equipment
damage may result.
If a problem occurs in serial communications during a test operation, you have no means to
stop the Motor.
Install external hardware to ensure that the Motor can be stopped at any time.
Before transferring parameters or data from the CX-Drive and Sysmac Studio to any other
node, check the safety around the target node.
Injury may result.
Check the axis (shaft) number before operating with the CX-Drive and Sysmac Studio.
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
21
Safety Precautions
Maintenance and Inspection
Do not attempt to disassemble, repair, or modify the Servomotor or Servo Drive.
Any attempt to do so may result in electric shock or other injury.
After replacing the Servo Drive, transfer to the new Servo Drive all data needed to resume
operation, before restarting operation.
Equipment damage may result.
Turn OFF the power supply when not using the Servomotor or Servo Drive for a long period
of time.
Not doing so may result in injury or malfunction.
Design the system to stop for at least ten minutes after the dynamic brake operates.
If it is used under more conditions, the dynamic brake may break and the brake may not
operate.
Caution
22
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
Safety Precautions
VOLTAGE
100~120V
1Ø 3Ø
0-120V
INPUT OUTPUT
PHASE
2.6A
50/60Hz
0~500.0Hz
1.7A
100W
A09080004
FREQ
POWER
OMRON Corporation
MADE IN JAPAN
SERIAL No.
F L C
Location of Warning Label
(R88D-KN02H-ECT-L)
Location of Warning Label
The Servo Drive bears a warning label at the following location to provide handling warnings.
When handling the Servo Drive, be sure to observe the instructions provided on this label.
Instructions on Warning Label
Disposal
• Dispose of the Servo Drive as industrial waste.
• When disposing of the battery, insulate it using tape and dispose of it by following the applicable
ordinance of your local government.
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
23
Regulations and Standards
Regulations and Standards
Overseas Use
To export (or provide to nonresident aliens) any part of this product that falls under the category of
goods (or technologies) for which an export certifica te or license is ma ndato ry accordi ng to the For eign
Exchange and Foreign Trade Control Law of Japan, an export certificate or license (or service
transaction approval) according to this law is required.
Conformance to EC Directives
For the G5-series Servo Drive which is an EC-compliant product, it is the user’s responsibility to check
and ensure the compliance of the equipment and the entire system with the applicable EC Directives.
EC DirectiveProductApplicable standards
Low Voltage DirectiveAC Servo DrivesEN61800-5-1
Linear MotorEN60034-1
EMC DirectiveAC Servo DrivesEN55011 classA group1
EN61000-6-2
EN61800-3
Machinery DirectivesAC Servo DrivesEN954-1 Cat.3
EN ISO13849-1 PL c, PL d
EN61508 (Part 1, 2, 4) SIL2
EN62061 SIL2
EN61800-5-2 (STO)
IEC61326-3-1
Note To conform to EMC Directives, the Servo Drive must be installed under the conditions described in 4-3
Wiring Conforming to EMC Directives on page 4-26.
24
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
Precautions for Correct UsePrecautions for Correct Use
*1 The R88D-KT20 and lower capacity Servo Drives are UL-listed .
The R88D-KT30 and higher capacity Servo Drives are UL-recognized.
This product complies with the UL 508C standard (file No. E179149) only when the following two
installation conditions are met.
Use the Servo Drive in an environment rated as Pollution Degree 2 or Pollution Degree 1 defined in
•
IEC60664-1. For example, the product meets this requirement when installed inside an IP54 control panel.
• Be sure to connect between the power supply and the no ise filter a circuit breaker or fuse that bears
the mark (which means a UL-listed product).
Refer to the following table for the rated current of the circuit breaker/fuse.
For wiring, use a copper conductor wire with a temperature rating of 75 ºC or higher.
Regulations and Standards
E179149
*1
Servo Drive modelCircuit breaker rated current [A]
• The G5-series Servo Drives comply with the Korean Radio Regulations (KC).
• The G5-series Servomotors and Linear Motors are exempt from the Korean Radio Regulations (KC).
SEMI F47
• Servo Drives conform to the SEMI F47 standard for momentary power interruptions (voltage sag
immunity) for no-load or light-load operation.
• This standard applies to semiconductor manufacturing equipment.
• It does not apply to Servo Drives with single-phase 100-V specifications or with 24 VDC
specifications for the control power input.
• Always perform evaluation testing for SEMI F47 compliance in the actual system.
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
25
Regulations and Standards
Trademarks
• Sysmac and SYSMAC are trademarks or registered trademarks of OMRON Corporation in Japan
and other countries for OMRON factory automation products.
• EtherCAT
GmbH, Germany.
Other company names and product names in this document are the trademarks or reg istered
trademarks of their respective companies.
® is registered trademark and patented technology, licensed by Beckhoff Automation
26
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
Items to Check after Unpacking
VOLTAGE
100~120V
1Ø 3Ø
0-120V
INPUT OUTPUT
PHASE
2.6A
50/60Hz
0~500.0Hz
1.7A
100W
A09080004
FREQ
POWER
OMRON Corporation
MADE IN JAPAN
SERIAL No.
F L C
Warning label
display location
(R88D-KN02H-ECT-L)
Items to Check after Unpacking
After unpacking, check the following items.
• Is this the model you ordered?
• Was there any damage sustained during shipment?
Servo Drive
Location of Servo Drive Rating Label
Servo Drive Rating Label
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
27
Items to Check after Unpacking
Location of Rating Label
Servo Drive Accessories
Safety Precautions document × 1 copy
• Connectors, mounting screws, mounting brackets, and other accessories other than those in the
table below are not supplied. They must be prepared by the customer.
• The safety bypass connector is required if the safety function is not used. To use the safety function,
provide a separate safety I/O signal connector.
• If any item is missing or a problem is found such as Servo Drive damage, contact the OMRON dealer
or sales office where you purchased your product.
Connector for main
circuit power supply
Specifications
Single-phase
100 VAC
Single-phase/
3-phase
200 VAC
3-phase
400 VAC
*1 Provide a safety connector separately to use the safety function.
100 WIncluded
200 W
400 W
200 W
400 W
750 W
1 kW
1.5 kW
600 W
1 kW
1.5 kW
2 kWIncludedIncluded
3 kW–
terminals and control
circuit power supply
terminals
Connector for External
Regeneration Resistor
connection terminals
and motor connection
terminals
Safety
bypass
connector
Included
*1
Mounting
brackets
–
28
Location of Iron-core Linear Motor Coil Unit Rating Label
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
Loading...
+ 596 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.