Special Information .......................................................................................................................................... 8
Terms and Conditions Agreement.......................................................................... 9
Warranty and Limitations of Liability ................................................................................................................ 9
Power Supply Design and Turning ON/OFF the Power Supply.....................................................................17
Actual Operation ............................................................................................................................................ 17
General Communications ..............................................................................................................................18
Cleaning and Maintenance ............................................................................................................................ 21
Regulations and Standards .................................................................................. 22
Conformance to EU Directives ......................................................................................................................22
Conformance to KC Standards......................................................................................................................23
Conformance to UL and CSA Standards.......................................................................................................23
Software Licenses and Copyrights ................................................................................................................23
Related Manuals..................................................................................................... 24
Related Products Manuals............................................................................................................................. 24
Terminology and Abbreviations ........................................................................... 26
Industrial PC Platform ...................................................................................................................................26
2-8-2 Fan Unit...................................................................................................................................2 - 17
A-1-7 BIOS - Save & Exit..................................................................................................................A - 11
A-2 Customize Windows ......................................................................................................... A - 12
A-2-1 Enhanced Write Filter............................................................................................................. A - 12
A-2-2 File-Based Write Filter............................................................................................................ A - 13
A-2-3 Unified Write Filter.................................................................................................................. A - 15
A-2-4 Trusted Platform Module........................................................................................................ A - 17
A-3 DVI Connector Pin Details................................................................................................ A - 18
A-3-1 DVI-I Connector Pin Details ................................................................................................... A - 18
A-3-2 DVI-D Connector Pin Details.................................................................................................. A - 19
A-4 RS-232C Connector Pin Details....................................................................................... A - 21
Restore and Repair Data ........................................................................................................7 - 30
BIOS Overview......................................................................................................................... A - 2
Index
6
NY-series Industrial Panel PC User's Manual (W555)
Page 9
Manual Information
A
B
C
E
F
B
C
H
5 Installation
5 - 3
N
Y-series User's Manual (W555)
5-1 Unpack
5
5-1-1 Unpack Procedure
G
5-1
Unpack
This section provides details on how to unpack the Industrial Panel PC.
5-1-1
Unpack Procedure
1 Check the package for damage.
If there is any visible damage:
• Take photos of the package and save them.
• Inform your supplier immediately.
2 Open the package.
Ensure not to damage the contents.
3 Ensure that all items are present.
Additional Information
Refer to 5-1-2 Items Supplied with the Product
for the items supplied.
This section provides information about this manual.
Page Structure
The following page structure is used in this manual.
Manual Information
Note: This illustration is provided as a sample. It will not literally appear in this manual.
ItemExplanationItemExplanation
ALevel 1 headingESpecial Information
BLevel 2 headingFManual name
CLevel 3 headingGPage tab with the number of the main section
DStep in a procedureHPage number
NY-series Industrial Panel PC User's Manual (W555)
7
Page 10
Manual Information
Special Information
Special information in this manual is classified as follows:
Precautions for Safe Use
Precautions on what to do and what not to do to ensure safe usage of the product.
Precautions for Correct Use
Precautions on what to do and what not to do to ensure proper operation and performance.
Additional Information
Additional information to read as required.
This information is provided to increase understanding or make operation easier
Version Information
.
Information on differences in specifications and functionality between different versions.
8
NY-series Industrial Panel PC User's Manual (W555)
Page 11
Terms and Conditions Agreement
Terms and Conditions Agreement
Warranty and Limitations of Liability
Warranty
• Exclusive Warranty
Omron’s exclusive warranty is that the Products will be free from defects in materials and workman-
ship for a period of twelve months from the date of sale by Omron (or such other period expressed
in writing by Omron). Omron disclaims all other warranties, expressed or implied.
• Limitations
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF
THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based
on infringement by the Products or otherwise of any intellectual property right.
• Buyer Remedy
Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally
shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-com-
plying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal
to the purchase price of the non-complying Product; provided that in no event shall Omron be re-
sponsible for warranty, repair, indemnity or any other claims or expenses regarding the Products un-
less Omron’s analysis confirms that the Products were properly handled, stored, installed and main-
tained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any
Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination
with any electrical or electronic components, circuits, system assemblies or any other materials or
substances or environments. Any advice, recommendations or information given orally or in writing,
are not to be construed as an amendment or addition to the above warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitations of Liability
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CON-
SEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY
WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT,
WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Com-
panies exceed the individual price of the Product on which liability is asserted.
NY-series Industrial Panel PC User's Manual (W555)
9
Page 12
Terms and Conditions Agreement
Application Considerations
Suitability for Use
Omron Companies shall not be responsible for conformity with any standards, codes or regulations
which apply to the combination of the Product in the Buyer
er’s request, Omron will provide applicable third party certification documents identifying ratings and
limitations of use which apply to the Product. This information by itself is not sufficient for a complete
determination of the suitability of the Product in combination with the end product, machine, system, or
other application or use. Buyer shall be solely responsible for determining appropriateness of the par-
ticular Product with respect to Buyer’s application, product or system. Buyer shall take application re-
sponsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR
PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO
ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND IN-
STALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
’s application or use of the Product. At Buy-
Programmable Products
• Omron Companies shall not be responsible for the user’s programming of a programmable Product,
or any consequence thereof.
•
Omron Companies shall not be responsible for the operation of the user accessible operating sys-
tem (e.g. Windows, Linux), or any consequence thereof.
Disclaimers
Performance Data
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for
the user in determining suitability and does not constitute a warranty
Omron’s test conditions, and the user must correlate it to actual application requirements. Actual per-
formance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications
. It may represent the result of
10
Product specifications and accessories may be changed at any time based on improvements and oth-
er reasons. It is our practice to change part numbers when published ratings or features are changed,
or when significant construction changes are made. However
be changed without any notice. When in doubt, special part numbers may be assigned to fix or estab-
lish key specifications for your application. Please consult with your Omron’s representative at any
time to confirm actual specifications of purchased Product.
, some specifications of the Product may
NY-series Industrial Panel PC User's Manual (W555)
Page 13
Terms and Conditions Agreement
Errors and Omissions
Information presented by Omron Companies has been checked and is believed to be accurate; how-
ever
, no responsibility is assumed for clerical, typographical or proofreading errors or omissions.
NY-series Industrial Panel PC User's Manual (W555)
11
Page 14
Safety Precautions
Safety Precautions
Definition of Precautionary Information
The following notation is used in this manual to provide precautions required to ensure safe usage of
the Industrial Panel PC. The safety precautions that are provided are extremely important to safety.
Always read and heed the information provided in all safety precautions.
The following notation is used.
Indicates a potentially hazardous situation which, if not avoid-
WARNING
Caution
ed, could result in death or serious injury
may be severe property damage.
Indicates a potentially hazardous situation which, if not avoid-
ed, may result in minor or moderate injury
. Additionally, there
, or property damage.
Symbols
The circle and slash symbol indicates operations that you must not do. The
specific operation is shown in the circle and explained in text.
This example indicates prohibiting disassembly
The triangle symbol indicates precautions (including warnings). The specific
operation is shown in the triangle and explained in text.
This example indicates a precaution for electric shock.
The triangle symbol indicates precautions (including warnings). The specific
operation is shown in the triangle and explained in text.
This example indicates a general precaution.
The filled circle symbol indicates operations that you must do. The specific
operation is shown in the circle and explained in text.
This example shows a general precaution for something that you must do.
.
12
NY-series Industrial Panel PC User's Manual (W555)
Page 15
Warnings
Disassembly and Dropping
Do not attempt to disassemble, repair, or modify the product in any way. Doing so may result in malfunction or fire.
Installation
Always connect to a ground of 100 Ω or less when installing the product.
Safety Precautions
WARNING
Ensure that installation and post-installation checks of the product are performed by personnel in charge who possess a thorough understanding of
the machinery to be installed.
Fail-safe Measures
Provide safety measures in external circuits to ensure safety in the system if
an abnormality occurs due to malfunction of the product or due to other external factors af
dents due to incorrect operation.
Emergency stop circuits, interlock circuit, limit circuits, and similar safety
measures must be provided in external control circuits.
Unintended behavior may occur when an error occurs in internal memory of
the product. As a countermeasure for such problems, external safety measures must be provided to ensure safe operation of the system.
The use of an uninterruptible power supply (UPS) allows normal operation
to continue even if a momentary power failure occurs, possibly resulting in
the reception of an erroneous signal from an external device affected by the
momentary power failure. Take external fail-safe measures. Where necessary, monitor the power supply voltage on the system for external devices
and use it as an interlock condition.
Do not use the input functions of the touchscreen in applications that involve
human life, in applications that may result in serious injury
stop switches.
fecting operation. Not doing so may result in serious acci-
, or for emergency
NY-series Industrial Panel PC User's Manual (W555)
13
Page 16
Safety Precautions
Actual Operation
Security setting adjustments should only be performed by the engineer in
charge that possesses a thorough understanding of the security settings.
Selecting non-recommended security settings can put your system at risk.
Changing BIOS information is only allowed for the engineer in charge that
possesses a thorough understanding of the BIOS settings because it can
change the behavior of the product.
Water or other liquid present on the touchscreen surface may create false
touch behavior and unexpected operation. Wipe away the liquid on the
touchscreen before operation.
14
NY-series Industrial Panel PC User's Manual (W555)
Page 17
Cautions
Industrial PC Platform Product
Non-isolated
Device
Non-isolated
Interface
24 VDC
0 VDC
Wiring
The product has an internal non-isolated DC power supply. Circuit ground (0
VDC) and frame ground are connected together. When connecting a nonisolated device or a non-isolated interface to the product, take appropriate
actions to avoid communication failures or damage to the mentioned ports.
Safety Precautions
Caution
Never ground the 24 VDC side of the power supply. This may cause a short
circuit.
NY-series Industrial Panel PC User's Manual (W555)
15
Page 18
Precautions for Safe Use
Precautions for Safe Use
Disassembly, Dropping, Mounting, Installation and Storage
• Do not drop the product or subject it to abnormal vibration or shock. Doing so may result in product
malfunction or burning.
• When unpacking, check carefully for any external scratches or other damages. Also, shake the
product gently and check for any abnormal sound.
• Always use the devices specified in the relevant manual.
• The product must be installed in a control panel.
• Always install equipment that is included in the product specifications. Not doing so may result in
failure or malfunction.
• If the storage period exceeds 6 months, check the performance of the Fan Unit before production
starts.
• Install the product in the correct orientation and temperature according to the specifications in the
manual to prevent overheating. Not doing so may result in malfunction.
• When connecting peripheral devices to the product, ensure sufficient countermeasures against
noise and static electricity during installation of the peripheral devices.
• The mounting panel must be between 1.6 and 6.0 mm thick. Tighten the Mounting Brackets evenly
to a torque of 0.6 Nm to maintain water and dust resistance. If the tightening torque exceeds the
specified value, or the tightening is not even, deformation of the front panel may occur. Additionally,
make sure the panel is not dirty or warped and that it is strong enough to hold the product.
• Do not let metal particles enter the product when preparing the panel. Do not allow wire clippings,
shavings, or other foreign material to enter any product. Otherwise, the product burning, failure, or
malfunction may occur. Cover the product or take other suitable countermeasures, especially during
wiring work.
Wiring
• Follow the instructions in the manual to correctly perform connector wiring and insertion. Double-
• Always ensure connectors, cables, PCIe Cards and Storage devices are completely locked in place
• Before you connect a computer to the product, disconnect the power supply plug of the computer
• Do not bend or pull the cables beyond normal limit. Do not place heavy objects on top of the cables
• Always use power supply wires with sufficient wire diameters to prevent voltage drop and burning.
• Be sure that all mounting bracket screws and cable connector screws are tightened to the torque
• Use crimp terminals for wiring.
check all wiring and connector insertion before turning ON the power supply.
to prevent accidental disconnection.
from the AC outlet. Also, if the computer has an FG terminal, make the connections so that the FG
terminal has the same electrical potential as the product. A difference in electrical potential between
the computer and the product may cause failure or malfunction.
or other wiring lines. Doing so may break the cables.
Make sure that the current capacity of the wire is sufficient. Otherwise, excessive heat may be gen-
erated. When cross-wiring terminals, the total current for all the terminals will flow in the wire. When
wiring cross-overs, make sure that the current capacity of each of the wires is not exceeded.
specified in the relevant manuals. The loose screws may result in fire or malfunction.
16
NY-series Industrial Panel PC User's Manual (W555)
Page 19
Precautions for Safe Use
• Observe the following precautions to prevent broken wires.
•
When you remove the sheath, be careful not to damage the conductor.
• Connect the conductor without twisting the wires.
• Do not weld the conductors. Doing so may cause the wires to break with vibration.
Power Supply Design and Turning ON/OFF the Power Supply
• Always use a power supply that provides power within the rated range.
Do not perform a dielectric strength test.
•
• Always use the recommended uninterruptible power supply (UPS) to prevent data loss and other
system file integrity issues caused by unexpected power interruption. Back up the system files in the
planned way to prevent data loss and other system file integrity issues caused by incorrect opera-
tion.
• Use an Omron S8BA UPS with the correct revision number to prevent improper system shutdown.
• Power ON after the DVI cable is connected between the product and an external monitor.
• Always check the power supply and power connections before applying power. Incorrect power con-
nections can damage the product or cause burning.
• Always turn OFF the power supply to system before you attempt any of the following.
• Inserting or removing PCIe Cards
• Connecting cables
• Connecting or disconnecting the connectors
• Wiring the system
• Replacing or removing the HDD/SSD
• Replacing the Battery
• Replacing the Fan Unit
Actual Operation
• Choose an operating system password that is not obvious to prevent unauthorized access.
Remember the OS user name and password. The product is inaccessible without it.
•
• Before operating the system , please make sure the appropriate software is installed and config-
ured. Doing so may prevent unexpected operation.
• Install all updates and ensure the browser stays up-to-date.
• Install all updates and ensure the firewall stays up-to-date.
• Make sure that your OS environment is protected against malicious software and viruses.
• Install all updates and ensure virus definitions stay up-to-date.
• Do not remove the fan cover while the power is ON. Contact with a rotating fan may result in injury.
• Virtual memory settings can affect the performance of the system. Disable the paging file after in-
stallation of applications or updates.
• Correctly perform wiring and setting, and ensure that the shutdown by the UPS can be executed.
• Always use the SMART monitoring feature for storage devices that do not comply to the Omron
Storage Device Specifications. Monitor the operating temperature and vibrations to ensure they stay
within the environmental specifications of the storage device.
NY-series Industrial Panel PC User's Manual (W555)
17
Page 20
Precautions for Safe Use
Operation
• Do not carry out the following operations when accessing a USB device or an SD Memory Card.
Turn OFF the power supply of the product.
•
• Press the Power Button of the product.
• Remove a USB device or SD memory card.
• Do not attempt to remove or touch the fan unit while the product is powered ON or immediately after
the power supply is turned OFF. If you attempt to replace the fan unit then, there is a risk of personal
injury due to hot or rotating parts.
• Press the power button for several seconds to force the product shutdown. Always back up files in
the planned way to prevent data loss or system file corruption.
• Do not touch any product housing when power is being supplied or immediately after the power sup-
ply is turned OFF. Doing so may result in burn injury.
• Confirm the safety of the system before using the touch panel.
• Signals from the touchscreen may not be entered if the touchscreen is pressed consecutively at
high speed. Only move on to the next operation after confirming that the product has detected the
previous input of the touchscreen.
• Do not accidentally press the touchscreen when the backlight is not lit or when the display does not
appear. Confirm the safety of the system before pressing the touchscreen.
• Do not use hard or pointed objects to operate or scrub the touchscreen, otherwise the surface of the
touchscreen may be damaged.
General Communications
• Separate the machine network segment from the office network to avoid communication failures.
Battery Replacement
• Dispose of any Battery that has been dropped on the floor or otherwise subjected to excessive
shock. Batteries that have been subjected to shock may leak if they are used.
UL standards require that only an experienced engineer replace the Battery. Make sure that an ex-
•
perienced engineer is in charge of Battery replacement.
• The Battery may leak, rupture, heat, or ignite. Never short-circuit, charge, disassemble, heat, or in-
cinerate the Battery or subject it to strong shock.
Cleaning, Maintenance and Disposal
• Do not use corrosive substances to clean the product. Doing so may result in the failure or malfunc-
tion.
Periodically check the installation conditions in applications where the product is subject to contact
•
with oil or water.
• As the rubber gasket will deteriorate, shrink, or harden depending on the operating environment, pe-
riodical inspection is necessary.
• Dispose of the product and batteries according to local ordinances as they apply.
18
NY-series Industrial Panel PC User's Manual (W555)
Page 21
Precautions for Safe Use
• The following information must be displayed for all products that contain primary lithium batteries
with a perchlorate content of 6 ppb or higher when shipped to or transported through the State of
California, USA.
Perchlorate Material - special handling may apply
See http://www.dtsc.ca.gov/hazardouswaste/perchlorate.
• The product contains a lithium battery with a perchlorate content of 6ppb or higher. When exporting
an end product containing the product to or shipping through California, USA, label all packing and
shipping containers appropriately.
.
NY-series Industrial Panel PC User's Manual (W555)
19
Page 22
Precautions for Correct Use
Precautions for Correct Use
Storage, Installation and Mounting
• Do not operate or store the product in the following locations. Operation may stop or malfunctions
may occur.
• Locations subject to direct sunlight
• Locations subject to temperatures or humidity outside the range specified in the specifications
• Locations subject to condensation as the result of severe changes in temperature
• Locations subject to corrosive or flammable gases
• Locations subject to dust (especially iron dust) or salts
• Locations subject to exposure to water, oil or chemicals
• Locations subject to shock or vibration
• Locations outdoors subject to direct wind and rain
• Locations subject to strong ultraviolet light
• Always install the product with sufficient surrounding space to allow for adequate heat dissipation
and cooling effect.
• Take appropriate and sufficient countermeasures when installing the product in the following loca-
tions
• Locations subject to strong, high-frequency noise
• Locations subject to static electricity or other forms of noise
• Locations subject to strong electromagnetic fields
• Locations subject to possible exposure to radioactivity
• Locations close to power lines
• Always touch a grounded piece of metal to discharge static electricity from your body before starting
an installation or maintenance procedure.
• Insert USB devices and PCIe devices correctly to avoid the burning, failure or malfunction.
• Execute a backup of the product before PCIe addition or replacement. Be sure that the PCIe device
works correctly before you use them for actual operation. PCIe devices and their related software
may cause an OS boot failure or crash.
• The backlight has a finite life and if that is exceeded, the product may fail or malfunction. Check the
brightness periodically and if necessary, replace the product.
• Ensure the selected operating system supports ACPI to enable operating system shutdown using
the power button.
• Download the enhanced Video Driver from the OMRON Download Center and install it on the Indus-
trial PC.
Wiring
20
• Always ensure the rated supply voltage is connected to the product.
• Do not allow wire clippings, shavings, or other foreign material to enter the product. Otherwise, burn-
ing, failure, or malfunction may occur. Cover the product or take other suitable countermeasures, es-
pecially during wiring work.
• Do not use cables exceeding the maximum specified length. Doing so may cause malfunction.
• Do not connect an AC power supply to the DC power connector.
NY-series Industrial Panel PC User's Manual (W555)
Page 23
Actual Operation and Operation
• After an OS update or a peripheral device driver update for the product is executed, the product be-
havior might be dif
• Always create a Windows System Repair Disk using Windows Backup and Restore to recover the
HDD/SSD configuration if necessary.
• Ensure the fan is operational to provide adequate cooling while the power is turned ON.
• HDD and SSD storage devices, SD Memory Cards, power buttons, fan units and batteries have fi-
nite lives and if those are exceeded, the product may fail or malfunction.
• Always monitor the fan status. If a fan is used beyond its service life, the Low Revolution Speed
warning message is displayed and the product overheating may occur.
• Always monitor the battery warning message. When a battery has low voltage, the system time will
be lost.
• The touchscreen supports 5 simultaneous touches. When the number of touches is exceeded, not
all touch points will be detected.
• The capacitive touchscreen reacts to contact on its surface. Accidental touching the surface of the
touchscreen may cause unintended behavior.
• You can operate the touchscreen even when you wear some gloves. Confirm that you can correctly
operate the touchscreen while wearing gloves prior to actual operation.
• Do not turn ON the power supply to the product when a part of a human body or a conductive object
is touching the surface of the touchscreen. Doing so will cause the touchscreen functionality to be
disabled. Remove the conductive object and cycle the power supply to restore the touchscreen
functionality.
• If the product experiences a sudden loss of power or disconnecting the cable while saving a setting
or transfer of data is underway, the changes may not be stored and unexpected behavior may occur.
• Ensure that available software checks are performed by personnel in charge who possess a thor-
ough understanding of the software.
• Diagnostic information is not available when the Industrial PC Support Utility is not installed.
ferent. Confirm that operation is correct before you start actual operation.
Precautions for Correct Use
Battery Replacement
• Turn ON the power after replacing the battery for a product that has been unused for an extended
period of time. Leaving the product unused without turning ON the power even once after the battery
is replaced may result in a shorter battery life.
Make sure to use a battery of the correct type, install the battery properly.
•
• Apply power for at least five minutes before changing the battery. Mount a new battery within five
minutes after turning OFF the power supply. If power is not supplied for at least five minutes, the
clock data may be lost. Check the clock data after changing the battery.
SD Memory Cards
• Insert an SD Memory Card completely and ensure it is in place.
Cleaning and Maintenance
• Do not use corrosive substances to clean the product.
Turn OFF the product or disable the touchscreen for cleaning with water.
•
NY-series Industrial Panel PC User's Manual (W555)
21
Page 24
Regulations and Standards
Regulations and Standards
Conformance to EU Directives
The Industrial Panel PC complies with EU Directives. To ensure that the machine or device in which
the Industrial Panel PC is used complies with EU Directives, the following precautions must be ob-
served:
• The Industrial Panel PC must be installed within a control panel.
• The Industrial Panel PC that complies with EU Directives also conforms to the Common Emission
Standard. Radiated emission characteristics (10-m regulations) may vary depending on the configu-
ration of the control panel used, other devices connected to the control panel, wiring, and other con-
ditions. You must therefore confirm that the overall machine or equipment in which the Industrial
Panel PC is used complies with EU Directives.
• This is a Class A product (for industrial environments). In a residential environment, it may cause
radio interference. If radio interference occurs, the user may be required to take appropriate meas-
ures.
Applicable Directive
EMC Directive
EMC Directive
OMRON devices that comply with EU Directives also conform to the related EMC standards so that
they can be more easily built into other devices or the overall machine. The actual products have been
checked for conformity to EMC standards.
Applicable EMC (Electromagnetic Compatibility) standards are as follows:
• EMS (Electromagnetic Susceptibility): EN 61131-2
• EMI (Electromagnetic Interference): EN 61131-2 (Radiated emission: 10-m regulations)
Whether the products conform to the standards in the system used by the customer, however, must be
checked by the customer. EMC-related performance of the OMRON devices that comply with EU Di-
rectives will vary depending on the configuration, wiring, and other conditions of the equipment or con-
trol panel on which the OMRON devices are installed. The customer must, therefore, perform the final
check to confirm that devices and the overall machine conform to EMC standards.
22
NY-series Industrial Panel PC User's Manual (W555)
Page 25
Conformance to KC Standards
Observe the following precaution if you use Industrial PC Platform products in Korea.
Class A Device (Broadcasting Communications Device for Office Use).
This device obtained EMC registration for of
other than homes.
Sellers and/or users need to take note of this.
fice use (Class A), and it is intended to be used in places
Conformance to UL and CSA Standards
Some Industrial PC Platform products comply with UL and CSA standards. If you use a product that
complies with UL or CSA standards and must apply those standards to your machinery or devices,
refer to this manual. This manual provides the application conditions for complying with the standards.
If the product is used in a manner not specified in the Instruction Sheet or in the product manuals then
the protection provided by the equipment may be impaired.
Regulations and Standards
Software Licenses and Copyrights
This product incorporates certain third party software. The license and copyright information associat-
ed with this software is available at http://www
.fa.omron.co.jp/nj_info_e/.
NY-series Industrial Panel PC User's Manual (W555)
23
Page 26
Related Manuals
Related Manuals
The following manuals are related. Use these manuals for reference.
Related Products Manuals
Manual
name
UPS
S8BA User's
Manual
UPS
Setting Utility Instruction
Manual
UPS Power
Attendant
Lite for Windows User's
Manual
Cat.
No.
U702S8BALearning the information
---
---S8BALearning the information
Model num-
bers
• SB8A
• BU-2R
WL
ApplicationDescription
that is necessary to use
the Uninterruptible Power Supply (UPS) Unit.
Learning the information
that is necessary to connect the UPS and to configure all settings.
that is necessary to use
the software to monitor
test and control the UPS
and to configure all settings.
An introduction to the UPS is provided
along with the following information:
• Overview
• Preparation
• Installation and Connection
• Check and Start Operation
• Maintenance and Inspection
• Shutdown Processing
• I/O Signal Functions
• T
roubleshooting
An introduction to the UPS Setting Utility is
provided along with the following information:
• Overview
• Operating Environment
• Software License Agreement
• Connect
• Use the UPS Setting Utility
• Setting Details
An introduction to the software is provided
along with the following information:
,
• Overviews
• Connection and Installation
• The Simple Usage and Operation Test
• Settings
24
NY-series Industrial Panel PC User's Manual (W555)
Page 27
Industrial Monitor Manual
This table contains the related manual of the Industrial Monitor.
Related Manuals
Manual
name
Industrial
Monitor
’s
User
Manual
Cat.
No.
W554
Model num-
bers
• NYM15W
C100£
• NYM12W-
C100£
ApplicationDescription
Learning all basic information
about the Industrial Monitor
includes introductory information
with features, hardware overview,
specifications, mounting, wiring,
connecting, operating and maintaining the Industrial Monitor.
. This
An introduction to the Industrial
Monitor is provided along with
the following information:
• Overview
• Hardware
• Software
• Specifications
• Installation
• Operating Procedures
• Maintenance
NY-series Industrial Panel PC User's Manual (W555)
25
Page 28
Terminology and Abbreviations
Terminology and Abbreviations
Industrial PC Platform
Term / AbbreviationDescription
Industrial PC PlatformAn integrated range of OMRON products designed for use in any industrial applica-
tion that will benefit from advanced PC technology
Industrial MonitorAn industrial monitor with a touchscreen as the user interface designed to work in
industrial environments
Industrial Panel PCAn industrial PC with an integrated touchscreen monitor designed to work in indus-
trial environments
Industrial Box PCA box-shaped industrial PC including an OS designed to work in industrial environ-
ments
IPCIndustrial PC
SysmacOMRON’s brand name of the product family for the industrial automation equip-
ment
Hardware
Term / AbbreviationDescription
BMCBoard Management Controller
CPUA Central Processing Unit is the hardware within a computer that executes the in-
DVIDigital Visual Interface
DVI-DA Digital Visual Interface with only Digital signals
DVI-IA Digital Visual Interface with Analog and Digital signals
EthernetA network communication protocol used in TCP/IP network
HDDA Hard Disk Drive storage device
HMIA Human Machine Interface that facilitates machine operation and control
iMLCIndustrial Multi-Level Cell type of SSD storage device
PCIeThe PCI Express is a high-speed computer bus standard called Peripheral Compo-
SATAThe Serial AT Attachment is a serial bus interface primarily used with mass storage
SLCSingle-Level Cell type of SSD storage device
SO-DIMMSmall Outline Dual Inline Memory Module
SSDA Solid State Drive storage device
USBUniversal Serial Bus
structions of a computer program
nent Interconnect Express
devices such as hard disk drives
26
NY-series Industrial Panel PC User's Manual (W555)
Page 29
Software
Term / AbbreviationDescription
ACPIAdvanced Configuration and Power Interface protocol for operating systems
APIApplication Programming Interface
BIOSBasic Input Output System. The first software run by a PC when powered on.
DeveloperAny person involved with the development of software
DSTDaylight Saving Time
EWFEnhanced Write Filter
FBWFFile-Based Write Filter
IIoTIndustrial Internet of Things
LinuxAn open source Operating System
MBRMaster Boot Record
Merge moduleA module providing a standard method by which developers deliver shared Win-
MSDNMicrosoft Developer Network
NUINatural User Interface
OSOperating System
PLCProgrammable Logic Controller
RTOSRealtime Operating System
SDKSoftware Development Kit
TCP/IPTransmission Control Protocol / Internet Protocol, a core member of the Internet
TPMTrusted Platform Module
VxWorksA Realtime Operating System designed by Wind River
WindowsAn Operating System designed by Microsoft
Terminology and Abbreviations
dows installer components and setup logic to their applications
protocol suite
NY-series Industrial Panel PC User's Manual (W555)
27
Page 30
W555-E2-03
Cat. No.
Revision code
Revision History
Revision History
A manual revision code appears as a suffix to the catalog number on the front and back covers of the
manual.
Revision codeDateRevised content
03May 2017
02December 2016
01August 2016First release
• Added operating system Windows 10 IoT Enterprise L
• Added Storage Device Considerations
• Modified UPS configuration procedure
• Several minor modifications
• UL implementation
• KC Standard implementation
• Minor modifications
TSB
28
NY-series Industrial Panel PC User's Manual (W555)
Page 31
Sections in this Manual
Operating Procedures
Specifications
Installation
Software
Hardware
Overview
1
2
3
4
5
6
1
2
3
4
6
5
1
7
7
Appendices
Maintenance
A
A
Sections in this Manual
NY-series Industrial Panel PC User's Manual (W555)
29
Page 32
Sections in this Manual
30
NY-series Industrial Panel PC User's Manual (W555)
Page 33
Overview
This section provides general information about the Industrial Panel PC.
Two 2.5 inch drive bays for HDD/SSD storage devices:
• Drive bay A = Bay for an optional drive
and main storage
Drive bay A is the bay at the side of the connectors
• Drive bay B = Bay for an optional drive
Drive bay B is the bay at the side of the display
(Power Status Output)
Refer to 4-1-4 CPU Specifications on page
Refer to 1-4 Product Configuration on page 1 - 5 for:
4 - 6 for the number of supported drives.
• installed drive (storage) details
• operating system details
*2
for the operating system
*2
for additional storage
2 - 4
NY-series Industrial Panel PC User's Manual (W555)
Page 45
A
B
C
D
2 Hardware
2-2
2-2-1
LED Indicators
The Industrial Panel PC has two rows of four LED indicators on the bottom of the Panel PC and two
LED indicators on the front of the Panel PC. These LED indicators provide the current operating status
of the Industrial Panel PC.
Bottom LED Indicators
The Industrial Panel PC has two rows of four LED indicators on the bottom that show the operating
status of the Industrial Panel PC. Both rows have the same function.
The following LED indicators are available:
2-2 LED Indicators
2
2-2-1 Bottom LED Indicators
Item
APWRPowerIndicates the operating mode of the Industrial Panel PC.
BERRErrorIndicates the presence and type of an error.
CHDDHard Disk
DRUNRunIndicates the status of a user-defined function.
LED
Indicator
NameDescription
Indicates HDD/SSD activity.
Drive
PWR LED Indicator
The Power LED (PWR) indicates the operating mode of the Panel PC.
ColorStatusMeaning
GreenNot litThere is no power supplied or the Panel PC is OFF.
BlinkingPower is currently supplied and the Panel PC is in
stand-by mode.
LitPower is currently supplied and the Panel PC is turned
ON.
NY-series Industrial Panel PC User's Manual (W555)
2 - 5
Page 46
2 Hardware
ERR LED Indicator
The Error LED (ERR) indicates the presence and type of an error within the Industrial Panel PC.
RedNot lit
ColorStatusMeaning
• The 24 VDC power is not supplied
• No error is present
Blinking
Lit
Fan Error
•
Battery low
•
Thermal shutdown
•
W
atchdog Error
•
Power Supply undervoltage error
•
Power Supply overvoltage error
•
• Power supply defective
Additional Information
• The status of this LED can also be defined by users using the Industrial PC System API.
Refer to 3-3-2 Industrial PC System API on page
3 - 25 for Industrial PC System API details.
• Refer to 7-2 Corrective Maintenance on page 7 - 13 for actions to solve errors.
HDD LED Indicator
The Hard Disk Drive LED (HDD) indicates activity of the HDD or SSD.
ColorStatusMeaning
YellowFlickeringThe HDD or SSD is active.
RUN LED Indicator
The RUN LED is available for user applications.
ColorStatusMeaning
GreenNot litUser-defined.
The status can be defined in a user program using the
Blinking
Lit
Additional Information
Refer to 3-3-2 Industrial PC System API on page 3 - 25
Industrial PC System API.
for Industrial PC System API details.
2 - 6
NY-series Industrial Panel PC User's Manual (W555)
Page 47
B
A
2 Hardware
2-2-2
Front LED and LED Indicator
The front of the Industrial Panel PC has a logo LED and a Status LED indicator.
The Status LED indicator provides the same information as the Power and Error LEDs on the bottom
of the Industrial Panel PC
The following LEDs are available on the front of the Industrial Panel PC.
.
2-2 LED Indicators
2
2-2-2 Front LED and LED Indicator
ItemLEDDescription
ALogo LEDLED to backlight the logo
BStatus Indicator
LED
Indicates the operating condition of the Industrial Panel PC
NY-series Industrial Panel PC User's Manual (W555)
2 - 7
Page 48
2 Hardware
Logo LED
The Logo LED brightness can be changed with the Industrial Monitor Utility.
Status LED Indicator
The Status LED indicator provides information about the operating condition of the Industrial Panel
PC.
Additional Information
The Logo LED brightness is adjustable.
Refer to Industrial Monitor Utility
for brightness details.
The Industrial Monitor Utility information is available:
• For products NYM£ in the section Software in this manual.
• For products NYP£ in the section Support Software in this manual.
• For products NY5£ in the NY-series IPC Machine Controller Industrial Panel PC / Industrial
Box PC Setup User’s Manual (Cat. No. W568)
ColorStatusMeaning
NoneNot litOne of the following situations:
• The 24 VDC power is not supplied.
• Normal operation
urned OFF by the Industrial Monitor Utility.
• T
Green
RedBlinkingOne of the following situations:
RedLitAt maximum brightness in following situations:
BlinkingPower is currently supplied and the Industrial Panel PC is in stand-by
mode.
Fan Error
•
Battery low
•
Power supply undervoltage error
•
Power supply overvoltage error
•
• Power supply defective
• Monitor internal hardware error
At controllable brightness in following situations:
Thermal shutdown
•
atchdog Error
W
•
Additional Information
• Refer to Industrial Monitor Utility information for brightness adjustment details.
• For Panel PCs without Machine Controller Software the status of this LED can also be defined by the Industrial Monitor API.
• The Industrial Monitor Utility information and the Monitor API information are available:
• For products NYP£ in the section Support Software.
• For products NY5£ in the NY-series IPC Machine Controller Industrial Panel PC / Industrial
Box PC Setup User’s Manual (Cat. No. W568)
• NY-series Software Development Kit User's Manual
2 - 8
NY-series Industrial Panel PC User's Manual (W555)
Page 49
2 Hardware
2-3
Power Button
The power button is used to manually switch the Panel PC ON and OFF.
Additional Information
2-3 Power Button
2
• Refer to 6-2 Power ON on page
• Refer to 6-3 Power OFF on page 6 - 5 for OFF details.
6 - 3 for ON details.
NY-series Industrial Panel PC User's Manual (W555)
2 - 9
Page 50
2 Hardware
2-4
Drive Bays
The drive bays in the Industrial Panel PC accept 2.5 inch Hard Disk Drives (HDD) or Solid State
Drives (SSD). Depending on the model one or two drives are supported.
Additional Information
• Refer to 4-1-4 CPU Specifications on page 4 - 6 for the number of supported drives.
• Refer to 4-1-6 Storage Device Specifications on page 4 - 8 for storage device specifications.
• Refer to 5-2-1 Install a Drive on page 5 - 5 for install information.
• Refer to 7-2-5 Replace a Drive on page 7 - 20 for maintenance information.
2 - 10
NY-series Industrial Panel PC User's Manual (W555)
Page 51
2 Hardware
2-5
SD Memory Card Slot
2-5 SD Memory Card Slot
The SD Memory Card slot on the Industrial Panel PC accepts SD Memory Cards with the following
specifications.
• SDHC type (SD 2.0 specification)
• Up to 32 GB capacity
2
Additional Information
Refer to 2-9-1 SD Memory Cards
on page 2 - 19 for SD Memory Card details.
NY-series Industrial Panel PC User's Manual (W555)
2 - 11
Page 52
A
B
2 Hardware
2-6
PCIe Card Slot
The PCI Express (PCIe) Card slot of the Industrial Panel PC accepts various PCIe Cards for specific
hardware needs.
The PCIe Card connectors are available behind the cover A and the PCIe Card is mounted in the
PCIe drawer B.
Additional Information
• Refer to 4-1-7 PCIe Card Specifications on page
• Refer to 5-2-2 Install the PCIe Card on page 5 - 9 for install information.
• Refer to 7-2-6 Replace the PCIe Card on page 7 - 25 for maintenance information.
4 - 10 for specifications.
2 - 12
NY-series Industrial Panel PC User's Manual (W555)
Page 53
2 Hardware
2-7
2-7-1
Connectors
This section gives an overview of the available connectors for the Industrial Panel PC.
2-7 Connectors
Power Connector
The power connector on the Panel PC is used to supply 24 VDC power to the Panel PC.
The power connector is supplied with the Panel PC.
2
2-7-1 Power Connector
2-7-2
Additional Information
• Refer to 4-2-1 Power Connector Specifications on page 4 - 12 for specifications.
Refer to 5-4-3 Wire the Power Connector on page 5 - 34 for wiring details.
•
• Refer to 5-5 Connect on page 5 - 40 for connection details.
I/O Connector
The I/O connector on the Industrial Panel PC provides discrete signals with the following functions.
Input signal to the Panel PC when a connected UPS switches to battery power.
•
• Input signal to the Panel PC to perform a shutdown or power ON when the signal turns ON.
• Output signal from the Panel PC to indicate the power status of the Panel PC.
The I/O connector is supplied with the Panel PC.
NY-series Industrial Panel PC User's Manual (W555)
2 - 13
Page 54
2 Hardware
Additional Information
2-7-3
• Refer to 4-2-2 I/O Connector Specifications on page 4 - 13
• Refer to 5-4-4 Wire the I/O Connector on page 5 - 37 for wiring details.
• Refer to 5-5 Connect on page 5 - 40 for connection details.
for specifications.
USB Connectors
The USB connectors support USB 2.0 and USB 3.0 specifications.
All USB interfaces are protected against overcurrent and all ports support W
ake-on-USB.
2 - 14
Additional Information
• Refer to 4-2-3 USB Connector Specifications
• Refer to 5-5 Connect on page 5 - 40 for connection details.
on page 4 - 17 for specifications.
NY-series Industrial Panel PC User's Manual (W555)
Page 55
2 Hardware
2-7-4
Ethernet Connectors
The Ethernet connectors provide 3 individual Ethernet ports on the Industrial Panel PC.
• Refer to 4-2-4 Ethernet Connector Specifications on page 4 - 18 for specifications.
•
Refer to 5-5 Connect on page 5 - 40 for connection details.
DVI Connector
The DVI interfaces supported on this connector are dependent on the configuration of the Industrial
Panel PC.
Additional Information
• Refer to 1-4 Product Configuration on page 1 - 5 for configuration details.
• Refer to 4-2-5 DVI Connector Specifications on page 4 - 19 for specifications.
• Refer to 5-5 Connect on page 5 - 40 for connection details.
NY-series Industrial Panel PC User's Manual (W555)
2 - 15
Page 56
2 Hardware
2-7-6
RS-232C Connector (Optional)
Depending on the product configuration an optional RS-232C connector is available.
Additional Information
• Refer to 1-4 Product Configuration on page 1 - 5 for configuration details.
• Refer to 4-2-7 RS-232C Connector Specifications on page 4 - 22 for specifications.
• Refer to 5-5 Connect on page 5 - 40 for connection details.
2-7-7
DVI-D Connector (Optional)
Depending on the product configuration an optional DVI-D connector is available. This interface only
supports digital video signals.
Additional Information
2 - 16
• Refer to 1-4 Product Configuration on page
• Refer to 4-2-6 DVI-D Connector Specifications on page 4 - 21 for specifications.
• Refer to 5-5 Connect on page 5 - 40 for connection details.
1 - 5 for configuration details.
NY-series Industrial Panel PC User's Manual (W555)
Page 57
2 Hardware
2-8
2-8-1
Spare Parts
The following spare parts for the Industrial Panel PC are available.
Battery
One battery is supplied with the Panel PC. The battery supplies power to the real-time clock.
The battery is located inside the Panel PC.
ModelAppearanceSpecifications
CJ1W-BAT01
Additional Information
Refer to 7-2-4 Replace the Battery on page 7 - 18 for the replacement procedure.
Service life: 5 years at 25°C
2-8 Spare Parts
2
2-8-1 Battery
2-8-2
Fan Unit
The Fan Unit is available for the Panel PC that has active cooling.
ModelAppearanceSpecifications
NY000-AF00
Additional Information
Refer to 7-2-3 Replace the Fan Unit on page 7 - 16
• Service life: 70,000 hours of continuous op-
eration at 40°C with 15% to 65% relative
humidity
• Shelf life: 6 months
This is the storage limitation with no power
supplied. W
ance testing if the Fan Unit has been stored
over 6 months.
for the replacement procedure.
e highly recommend perform-
NY-series Industrial Panel PC User's Manual (W555)
2 - 17
Page 58
2 Hardware
2-8-3
Accessory Kit
The accessory kit for the Panel PC.
ModelAppearanceSpecifications
NY000-AK00Accessory Kit containing all acces-
sories supplied with the
• Power connector
• I/O connector
• Drive bracket for drive installation
• 4 mounting screws for drive in-
stallation
• PCIe Card support for PCIe Card
installation
• PCIe Card clip for PCIe Card in-
stallation
Panel PC.
2 - 18
NY-series Industrial Panel PC User's Manual (W555)
Page 59
FZ-MEM2G
2 Hardware
2-9
2-9-1
2-9-2
Optional Hardware
The following optional hardware is available for the Industrial Panel PC.
SD Memory Cards
SD Memory Card details are provided below.
OMRON is not responsible for the operation, performance or write life of any other brand of SD Memo-
ry Card.
ModelAppearanceCard typeCapacityFormat
HMC-SD291
HMC-SD491SDHC Card4 GBFAT32
USB Flash Drives
USB Flash Drive details are provided below.
OMRON is not responsible for the operation, performance, or write life of any other brand of USB
Flash Drives.
SD Card2 GBFAT16
2-9 Optional Hardware
2
2-9-1 SD Memory Cards
ModelAppearanceCapacity
FZ-MEM2G
FZ-MEM8G8 GB
2 GB
NY-series Industrial Panel PC User's Manual (W555)
2 - 19
Page 60
2 Hardware
2-9-3
Storage Devices
Storage device details are provided below.
OMRON is not responsible for the operation, performance, or write life of any other storage device.
ModelAppearanceStorage typeCapacity
NY000-AH00HDD320 GB
NY000-AS00SSD SLC32 GB
NY000-AS0164 GB
NY000-AS02SSD iMLC128 GB
Additional Information
Refer to 4-1-6 Storage Device Specifications
on page 4 - 8 for storage device specifications.
Storage Device Considerations
For a storage device that is not an OMRON NY000-A£££ consider the following:
• OMRON is not responsible for the operation, performance or write life of any storage device other
than those supplied by OMRON.
• Test and measure the environmental performance of the intended storage device before actual op-
eration, using the SMART monitoring feature of the selected storage device.
• Ensure the temperature and vibrations of the storage device are within the operating temperature
specifications and vibration specifications during actual operation.
• Using a storage device with maximum power consumption exceeding 2W is not advised. Ensure
that the SMART monitor features of the storage device are used to detect overheating.
Additional Information
• Refer to 4-1-6 Storage Device Specifications on page 4 - 8 for storage device specifications.
• Refer to 4-5-1 Operation Environment Specifications on page 4 - 25 for environment specifications, specifically temperature and vibration specifications.
2 - 20
NY-series Industrial Panel PC User's Manual (W555)
Page 61
90 mm
60 mm
2 Hardware
2-9-4
DVI Cables
DVI cable details are provided below.
OMRON is not responsible for the operation or performance of any other brand of DVI cable.
ModelAppearanceCable lengthSpecifications
NY000AC00 2M
NY000AC00 5M
2 m
5 m
• Supports DVI-D
• Minimum bend radius: 36 mm
DVI Cable Clearance
The DVI cable requires a minimum clearance of 90 mm from the connector entry to prevent excessive
strain on the connector and cable assembly
.
2-9 Optional Hardware
2
2-9-4 DVI Cables
2-9-5
USB Type-A to USB Type-B Cables
USB Type-A to USB Type-B cable details are provided below.
OMRON is not responsible for the operation or performance of any other brand of USB T
Type-B cable.
ModelAppearanceCable lengthSpecifications
FH-VUAB 2M2 m
FH-VUAB 5M5 m
• USB 2.0
• Minimum bend radius: 25 mm
ype-A to USB
USB Type-A to USB Type-B Cable Clearance
The USB Type-A to USB Type-B cable requires a minimum clearance of 60 mm from the connector
entry to prevent excessive strain on the connector and cable assembly
.
NY-series Industrial Panel PC User's Manual (W555)
2 - 21
Page 62
2 Hardware
2-9-6
2-9-7
Industrial Monitor
Details for the recommended monitor are provided below.
OMRON is not responsible for the operation or performance of any other monitor
ModelAppearanceSpecifications
NYM15W-C100£
NYM12W
-C100£
Additional Information
Refer to the OMRON website for specifications and manuals.
• LCD touchscreen
• Multi-touch functionality
• Supply voltage: 24 VDC
• Up to 1,280 x 800 pixels at 60 Hz
• 2 USB T
• Programmable brightness control
Power Supply
.
ype-A Connectors
Details for the recommended power supply are provided below.
OMRON is not responsible for the operation or performance of any other power supply
ModelAppearanceSpecifications
S8VK-G£££24
Additional Information
• Refer to 4-1-3 Power Consumption Specifications on page
tails.
• Refer to
Note that the power consumption details of the
ing of your power supply.
the OMRON website for specifications and manuals of the S8VK-G.
Panel PC determine the minimum power rat-
Output voltage: 24 VDC
4 - 3 for power consumption de-
.
2 - 22
NY-series Industrial Panel PC User's Manual (W555)
Page 63
A
3
2 Hardware
2-9-8
UPS
Details for the recommended UPS are provided below.
OMRON is not responsible for the operation or performance of any other UPS.
ModelAppearanceSpecifications
S8BA with revision number 04 or
*1
.
higher
*1.The revision number of the UPS can be retrieved from the serial number label on the product and the prod-
uct packaging.
ItemDescription
1Product code
2Product period and sequential number
3Revision number
4RoHS status
Output voltage during backup operation: 24 VDC±5%
2-9 Optional Hardware
2
2-9-8 UPS
2-9-9
Precautions for Safe Use
Use an Omron S8BA UPS with the correct revision number to prevent improper system shutdown.
Additional Information
• Refer to 2-9-7 Power Supply on page 2 - 22
for power supply details.
• Refer to 4-1-3 Power Consumption Specifications on page 4 - 3 for power consumption details.
• Refer to
the OMRON website for S8BA specifications or to the UPS S8BA User's Manual(Cat. No. U702) for the UPS manual.
Note that the power consumption details determine the output current/capacity of your UPS.
UPS Communication Cable
Communication cable details are provided below.
OMRON is not responsible for the operation or performance of any other brand of communication ca-
ble.
ModelAppearanceCable lengthSpecifications
S8BW-C02
2 mSignals for
• Signal output (BL, TR, BU, WB)
• Remote ON/OFF input
• UPS Stop Signal input (BS)
NY-series Industrial Panel PC User's Manual (W555)
2 - 23
Page 64
2 Hardware
2 - 24
NY-series Industrial Panel PC User's Manual (W555)
Page 65
Software
3
3
This section provides software information for the Industrial Panel PC.
3-1
Windows Operating System........................................................................ 3 - 2
3-1-1 Determine Your Version of the Windows Operating Systems....................... 3 - 2
3-1-2 Determine Your Ethernet Ports ..................................................................... 3 - 3
3-2 Support Software .........................................................................................3 - 4
3-2-1 Overview IPC Support Software for Windows .............................................. 3 - 4
3-2-2 Installed IPC Support Software..................................................................... 3 - 4
3-2-3 Industrial PC Support Utility ......................................................................... 3 - 5
3-2-6 Rescue Disk Creator................................................................................... 3 - 14
3-2-7 Industrial PC Tray Utility ............................................................................ 3 - 18
3-2-8 Power Attendant Lite Utility......................................................................... 3 - 21
3-3 Software for Developers............................................................................ 3 - 24
3-3-1 Overview IPC Developer Software for Windows ........................................ 3 - 24
3-3-2 Industrial PC System API .......................................................................... 3 - 25
3-3-3 Industrial Monitor API ................................................................................ 3 - 26
NY-series Industrial Panel PC User's Manual (W555)
3 - 1
Page 66
3 Software
3-1
3-1-1
Windows Operating System
This section provides an overview of Windows Operating System information.
Determine Your Version of the Windows Operating Systems
This section provides methods to find version details of your Windows Operating System.
Windows 7
To determine your version of the Windows Operating System:
1Select the Start Button.
2Enter System Information in the search box.
3Select System Information in the pop-up that appears.
An overview of your System Information will appear
details.
, including the Windows Operating System
Windows 10
To determine your version of the Windows Operating System:
1Select the Search Button.
2Enter System Information in the search box.
3Select System Information
An overview of your System Information will appear, including the Windows Operating System
details.
in the pop-up that appears.
3 - 2
NY-series Industrial Panel PC User's Manual (W555)
Page 67
3 Software
3-1-2
Determine Your Ethernet Ports
This section provides information to determine the relation between the physical Ethernet ports on
your Industrial Panel PC
and the ports in Windows.
Available Ethernet Ports
The Ethernet ports available are:
•
Port 1 - Local Area Connection - I218 (Intel® Ethernet Connection I218-LM)
• Port 2 - Local Area Connection 3 - I210 #2 (Intel® I210 Gigabit Ethernet Network Connection #2)
• Port 3 - Local Area Connection 2 - I210 (Intel® I210 Gigabit Ethernet Network Connection)
The following procedure provides information to determine the Ethernet ports on your Industrial Panel
PC.
Determine Ethernet Ports using Network Connections
To determine the Ethernet ports using computer management:
3-1 Windows Operating System
3
3-1-2 Determine Your Ethernet Ports
1Select the Start Button.
2Enter Network in the search box.
3Select Network and Sharing Center in the pop-up that appears.
An overview of your basic network information and set up connections will appear
series of options in the left bar.
4Select Change adapter settings in the left bar
An overview of your adapters will appear.
5Determine the specific connector with the information in A
The adapter name and the connector ID are known.
.
vailable Ethernet Ports on page 3 - 3.
, including a
NY-series Industrial Panel PC User's Manual (W555)
3 - 3
Page 68
3 Software
3-2
3-2-1
Support Software
This section provides an overview of the support software available for your Industrial Panel PC.
Overview IPC Support Software for Windows
This section gives an overview of the software utilities available for all Industrial PC Platform products
with a Windows operating system.
ProductSoftware utility
Industrial MonitorIndustrial Monitor Utility
Industrial Monitor Brightness Utility
Industrial PC T
Industrial Box PCIndustrial PC Support Utility
Industrial PC T
Industrial Panel PCIndustrial Monitor Utility
Industrial Monitor Brightness Utility
Industrial PC Support Utility
Industrial PC T
Select and download the utilities required from the OMRON download website.
ray Utility
ray Utility
ray Utility
3-2-2
Additional Information
• An internet connection is required to install support software.
•
Refer to NY-series Industrial Panel PC User’s Manual (Cat. No. W555) for support software
details.
Installed IPC Support Software
This section gives an overview of the installed IPC support software available for your Industrial Panel
PC.
ProductSpecifications
Industrial PC Support UtilityRefer to 3-2-3 Industrial PC Support Utility
3 - 5 for details.
Industrial PC Tray UtilityRefer to 3-2-7 Industrial PC T
3 - 18 for details.
Industrial PC System APIFor the Industrial PC Support Utility.
Industrial Monitor APIFor the display and for an optional OMRON Industrial
Monitor.
congatec CGOS APIFor the Industrial PC System API.
Microsoft .NET Framework 4.6For the Industrial PC Tray Utility.
Industrial Monitor Brightness UtilityFor the display and for an optional OMRON Industrial
Monitor.
Industrial Monitor UtilityFor the display and for an optional OMRON Industrial
Monitor.
ray Utility on page
on page
3 - 4
NY-series Industrial Panel PC User's Manual (W555)
Page 69
FE
DC
B
A
C
3 Software
3-2-3
Industrial PC Support Utility
This section provides an overview of the Industrial PC Support Utility.
Industrial PC Support Utility Overview
The Industrial PC Support Utility is a software utility to assist in diagnosing and resolving problems of
the Industrial Panel PC
.
3-2 Support Software
3
3-2-3 Industrial PC Support Utility
ItemDescriptionDetails
AProduction Data Tab
BSystem Status Tab
CTab detailsDetails of the selected Tab page.
DLanguage SelectorSelect to display and choose the UI language of the Industrial PC Support
EClose ButtonClose the Industrial PC Support Utility.
FUpdate Screen ButtonUse this button to retrieve updated values from the Industrial Panel PC.
Select to display Production Data details in the Tab details area C.
Refer to Production Data T
Select to display System Status details in the Tab details area
Refer to System Status T
Utility.
ab on page 3 - 6 for details.
.
ab on page 3 - 7 for details.
NY-series Industrial Panel PC User's Manual (W555)
3 - 5
Page 70
3 Software
The Production Data tab displays generic Industrial Panel PC information. These are e.g. Model
name, Lot number
sions (Industrial PC Support Utility and Industrial PC System API).
Production Data Tab
, Serial number, Hardware version, BIOS version, BMC version, and software ver-
• Model Name is the configuration code of this model.
Refer to 1-4 Product Configuration
• BMC Version is the firmware version of the Board Management Controller.
Values are not updated automatically. Select the Update Screen Button to display the latest values.
on page 1 - 5 for details.
3 - 6
NY-series Industrial Panel PC User's Manual (W555)
Page 71
3 Software
System Status Tab
The System Status tab displays actual states and diagnostic information like internal temperature, fan
revolution, battery and power supply status.
A status that requires attention is indicated with a red bar
.
3-2 Support Software
3
3-2-3 Industrial PC Support Utility
ItemDescription
*1
Internal Temperature
Fan Revolution
*2
The average CPU temperature.
The actual rotation speed for each fan in revolutions per minute (r/min).
• First number = rotation speed of fan located closest to Power button.
.
Fan Status
• Second number = rotation speed of fan located closest to battery
*3
The target speed for the fans is dynamically set based on the CPU temperature. The
target speed is compared with the actual fan speed.
• OK indicates both fans are running on the target speed.
• Low revolution speed indicates one or both fans do not reach the target speed.
Clean the fans and replace the Fan Unit if the problem persists.
Refer to 7-2-3 Replace the Fan Unit on page 7 - 16 for replacement details.
Battery StatusThe battery status.
• OK indicates the battery is full.
• Low indicates the battery voltage is low. Replace the battery.
Refer to 7-2-4 Replace the Battery on page 7 - 18 for replacement details.
Power SupplyThe power supply status is determined by the UPS and reported to the Panel PC via
the I/O connector.
• NormalPowerSupply indicates the Panel PC is powered by the 24V power supply.
• UPS Power Supply indicates that there is no power from the 24V power supply
and the Panel PC runs on battery power from the UPS.
*1.
Not for products NY512-A£
Refer to 1-4 Product Configuration on page
*2.The Fan Revolution will always show 0 (r/min) / 0 (r/min) for fanless models
1 - 5 for configuration details.
NY-series Industrial Panel PC User's Manual (W555)
3 - 7
Page 72
3 Software
Refer to 1-4 Product Configuration on page
*3.The Fan Status will always show OK for fanless models
Values are not updated automatically. Select the Update Screen Button to display the latest values.
1 - 5 for fan details.
Installation
The Industrial PC Support Utility is pre-installed on the Industrial Box PC and Industrial Panel PC.
Download the
quired.
Industrial PC Support Utility from the OMRON download website if reinstallation is re-
Startup
The Industrial PC Support Utility can be started from:
•
Windows Start Menu
Select OMRON and then Industrial PC Support Utility.
• Industrial PC Tray Utility
• Windows desktop shortcut
Logging
There is logging in the Windows event log of the following utilities:
Industrial Monitor Utility
•
In the Windows Event Viewer filter for event source IndMonService.
• Industrial Monitor Brightness Utility
In the Windows Event Viewer filter for event source IndMonService.
• Industrial PC Support Utility
In the Windows Event Viewer filter for event source IPCServiceHost or OMRON Industrial PC
Support Utility.
Additional Information
Refer to 7-2-9 W
indows Event Viewer on page 7 - 38 for the logged messages.
3 - 8
NY-series Industrial Panel PC User's Manual (W555)
Page 73
A
B
C
D
E
F
G
I
J
K
H
3 Software
3-2-4
Industrial Monitor Utility
This section provides an overview of the Industrial Monitor Utility.
Industrial Monitor Utility Overview
The Industrial Monitor Utility provides a user interface to control settings and display details of con-
nected Industrial Monitor
s.
3-2 Support Software
3
3-2-4 Industrial Monitor Utility
ItemDescriptionDetails
AConnected Monitors
BProduct InformationProvides the following details of the selected Industrial Monitor.
Shows a list of the connected Industrial Monitors.*1 Select one
Monitor in the list to display the Monitor Details. When selected the LED Indicators of the selected monitor will flash during 3 seconds.
Industrial
• Serial Number
• Screen Size
• Hardware V
ersion
• Software Version
• Model Name
• Factory Identifier
• Unit Lot Number
• Logo Type
• Video Status
CMonitor SettingsProvides several setting adjustments to control the operation of the selected
Industrial Monitor
DBacklight Brightness Ad-
justment
ELogo Brightness Adjust-
ment
FStatus Brightness Adjust-
ment
*2
GAdvanced SettingsProvides advanced setting adjustments to control the operation of the se-
HRestore Factory DefaultsRestores the factory default settings of the selected Industrial Monitor.
Use the slider to control the brightness of the selected Industrial Monitor.
Use the slider to control the brightness of the Logo LED.
Refer to Logo LED on page 2 - 8 for details about the Logo LED.
Use the slider to control the brightness of the Status LED Indicator on the
.
monitor
Refer to Status LED Indicator on page 2 - 8 for details about the operation
of the Status LED Indicator.
Industrial Monitor.
lected
.
NY-series Industrial Panel PC User's Manual (W555)
3 - 9
Page 74
3 Software
*1.The Industrial Monitor Utility scans the connected USB devices and shows a list of connected monitors. If an
*2.With a very low backlight brightness setting (15%-0%) the displayed information might not be visible in an envi-
ItemDescriptionDetails
IOK buttonApplies the changes and closes the window
JCancel buttonExits the utility
KApply buttonApplies the changes
Industrial Monitor
ronment with high ambient light conditions. This prevents brightness adjustments with the Industrial Monitor Utility.
Additional Information
To adjust the backlight brightness when the brightness setting is set too low:
• Bring the Panel PC
• Lighten the display with a bright flashlight
is not connected with the USB cable, it will not be found.
in a low ambient light environment
Installation
The Industrial Monitor Utility is pre-installed on the Industrial Box PC and the Industrial Panel PC.
Download the
stallation on another Industrial PC.
The Industrial Monitor Utility is installed onto Windows, and can be accessed via the Windows start
menu and the Industrial PC Tray Utility. Installing the Industrial Monitor Utility will also install the Indus-
trial PC Tray Utility.
Additional Information
Refer to 3-2-7 Industrial PC T
Industrial Monitor Utility from the OMRON download website for re-installation or for in-
ray Utility on page 3 - 18 for Industrial PC Tray Utility details.
Compatibility
This monitor utility can be used on any PC that is connected to an OMRON Industrial Monitor.
This monitor utility can be used with:
Windows Embedded Standard 7
•
• Windows 10
3 - 10
Additional Information
This monitor utility does not support 3rd party monitors.
Startup
The Industrial Monitor Utility can be started from:
Windows Start Menu.
•
Select Omron and then Industrial Monitor Utility.
• Industrial PC Tray Utility
NY-series Industrial Panel PC User's Manual (W555)
Page 75
3 Software
Configuration
The Industrial Monitor Utility can be configured with following options:
Configuration itemDescription
LanguageFollows the Windows language configuration when that language is supported for the
Industrial Monitor Utility
guage configured in Windows is not supported.
Monitor identificationIf enabled, the Status LED indicator on the selected Industrial Monitor will flash for 3
seconds.
o enable:
T
(1) Open the Windows registry key HKEY_LOCAL_MACHINE\SOFTWARE
\Wow6432Node\Omron\IPC\MonitorConfiguration
(2) Set the registry value Indicate to value True.
. The default language English (EN-US) will be used if the lan-
3-2 Support Software
3
Messages
The Industrial Monitor Utility can use the Industrial PC Tray Utility to display following messages:
Message typeMessageDescription
InfoConnectedA new monitor connected
• USB cable connected
• Monitor powered ON
WarningNot ConnectedMonitor disconnected
• USB cable disconnected
• Monitor powered OFF
WarningVideo Discon-
nected
WarningNo SignalDVI cable connected but no signal detected
DVI cable disconnected or NY Monitor Link cable disconnected
Logging
There is logging in the Windows event log of the following utilities:
• Industrial Monitor Utility
In the Windows Event Viewer filter for event source IndMonService.
• Industrial Monitor Brightness Utility
In the Windows Event Viewer filter for event source IndMonService.
• Industrial PC Support Utility
In the Windows Event Viewer filter for event source IPCServiceHost or OMRON Industrial PC
Support Utility.
3-2-4 Industrial Monitor Utility
Additional Information
Refer to 7-2-9 Windows Event Viewer on page 7 - 38 for the logged messages.
NY-series Industrial Panel PC User's Manual (W555)
3 - 11
Page 76
A
B
3 Software
3-2-5
Industrial Monitor Brightness Utility
This section provides an overview of the Industrial Monitor Brightness Utility.
Industrial Monitor Brightness Utility
The Industrial Monitor Brightness Utility is a software utility that allows you to control the brightness of
the screen backlight of all connected
Industrial Monitors.
ItemDescriptionDetails
ABacklight brightness slider Use the slider to control the display brightness of all connected Industrial
Monitors.
BIndustrial Monitor UtilityButton to start the Industrial Monitor Utility.
With a very low backlight brightness setting (15%-0%) the displayed information might not be visible in
an environment with high ambient light conditions. This prevents brightness adjustments with the In-
dustrial Monitor Brightness Utility.
Additional Information
To adjust the backlight brightness when the brightness setting is set too low:
• Bring the Panel PC in a low ambient light environment
• Lighten the display with a bright flashlight
Compatibility
This monitor utility can be used on any PC that is connected to an OMRON Industrial Monitor.
This monitor utility can be used with:
• Windows Embedded Standard 7
• Windows 10
3 - 12
Additional Information
This monitor utility does not support 3rd party monitors.
NY-series Industrial Panel PC User's Manual (W555)
Page 77
3 Software
Installation
The Industrial Monitor Brightness Utility is pre-installed on the Industrial Box PC and the Industrial
Panel PC
Installation of the Industrial Monitor Brightness Utility is part of the installation of the Industrial Monitor
Utility.
Download the Industrial Monitor Utility from the OMRON download website for re-installation or for in-
stallation on another PC with Windows 7.
The Industrial Monitor Brightness Utility is installed onto Windows, and can be accessed via the Win-
dows start menu and the Industrial PC Tray Utility. Installing the Industrial Monitor Utility will also in-
stall the Industrial PC Tray Utility.
.
3-2 Support Software
Additional Information
Refer to 3-2-7 Industrial PC T
ray Utility on page 3 - 18 for Industrial PC Tray Utility details.
Startup
Start the Industrial Monitor Brightness Utility from the Industrial PC Tray Utility or from the Windows
Start Menu (select Omron and then Industrial Monitor Brightness Utility
Additional Information
Refer to 3-2-7 Industrial PC T
ray Utility on page 3 - 18 for Industrial PC Tray Utility details.
).
Configuration
Configuration is not required. This Industrial Monitor Brightness Utility will detect and support all con-
nected NY
-series Industrial Monitors.
Logging
3
3-2-5 Industrial Monitor Brightness Utility
There is logging in the Windows event log of the following utilities:
•
Industrial Monitor Utility
In the Windows Event Viewer filter for event source IndMonService.
• Industrial Monitor Brightness Utility
In the Windows Event Viewer filter for event source IndMonService.
• Industrial PC Support Utility
In the Windows Event Viewer filter for event source IPCServiceHost or OMRON Industrial PC
Support Utility.
Additional Information
Refer to 7-2-9 W
NY-series Industrial Panel PC User's Manual (W555)
indows Event Viewer on page 7 - 38 for the logged messages.
3 - 13
Page 78
B
C
E
F
D
A
3 Software
3-2-6
Rescue Disk Creator
This section provides an overview of the Rescue Disk Creator.
Rescue Disk Creator Overview
The Rescue Disk Creator creates a Rescue Disk.
A Rescue Disk is a disk with the
backup and system restore procedures.
Rescue Disk Utility; this is the software that performs the system
3 - 14
ItemDescriptionDetails
AExplanation areaInformation about the utility and the backup.
In the right bottom corner messages are displayed when applicable.
BTarget disk selectionSelection of the disk that will become the Rescue Disk.
CCreate Rescue Disk ButtonStart the Rescue Disk creation.
DShow non-removable disksCheck the box to display not only the removable storage devices
but also the non-removable (internal) storage devices and USB
Flash Drives and other USB storage devices.
ECreation progress barDisplay the progress of the Rescue Disk creation.
FClose ButtonClose the Rescue Disk Creator.
Additional Information
• Refer to Create a System Backup with the Rescue Disk on page
details.
• Refer to Restore a System Backup with the Rescue Disk on page 7 - 31 for system restore
7 - 7 for system backup
details.
NY-series Industrial Panel PC User's Manual (W555)
Page 79
Compatibility
This software utility can be used on PCs with Windows 7 and Windows 10.
3 Software
Installation
The Rescue Disk Creator is preinstalled.
Use the following procedure to reinstall the Rescue Disk Creator:
1Use Windows Explorer to examine the local disk C.
2Open the Rescue Disk folder (This PC\Local Disk(C:)\Program Files (x86)\OMRON\Industrial
PC\Rescue Disk) and activate the installer file setup.exe.
A progress bar will visualize the extraction process and then a language selection window
opens.
3Select your language and then select OK.
The installer window opens.
4Follow the installer steps to complete the Rescue Disk Creator installation.
The Rescue Disk Creator is installed and available in the OMRON folder in the Windows Start Menu.
3-2 Support Software
3
3-2-6 Rescue Disk Creator
Startup
To manually start the Rescue Disk Utility:
1Locate the Rescue Disk Utility using the Windows Start menu or the Windows search box.
2Use the option Run as administrator to activate the
NY-series Industrial Panel PC User's Manual (W555)
Rescue Disk Utility.
3 - 15
Page 80
3 Software
The Rescue Disk Utility started.
The Rescue Disk Creator can display the following messages:
Additional Information
The procedure to use Run as administrator is:
•
For Windows 10 using the Start menu:
Rightclick the Rescue Disk Utility, select More and then Run as administrator.
• For Windows 10 using Search:
Rightclick the Rescue Disk Utility in the search results and select Run as administrator.
• For Windows 7 using the Start menu or Search:
Rightclick the Rescue Disk Utility and select Run as administrator.
Messages
Message
type
ErrorCreation progress: Failed to format the disk.
Reason:
MessageDescription
• Access denied
• Call canceled
• Call cancellation request too late
• Cluster size is beyond 32 bits
• Cluster size is too large
• Cluster size is too small
• Incompatible media in drive
• Invalid volume label
• Input/Output (I/O) error
• No media in drive
• Unable to quick format
• Unknown error
• Unsupported file system
• V
olume lock failed
• Volume is not mounted
• Volume is too large
• Volume is too small
• Volume write protected
ErrorCreation progress: Failed to copy image to
rescue disk.
Reason:
• Unable to revoke access to the disk
• Unable to revoke access to the drive
• Disk write failed
• Unable to dismount the drive
• Invalid drive
• Unable to obtain exclusive access to the
drive
• The disk could not be accessed
• The drive could not be accessed
• Unable to revoke exclusive access to the
drive
The mentioned reason prevented formatting of
the connected storage device.
Ensure the connected storage device:
• Is not write protected or read-only
• Has a cluster size too small or more than
the maximum 32 bits
• Has a valid volume label
• Has suf
rescue disk utility and a full system backup
The mentioned reason prevented copying the
image to the connected storage device.
Ensure the connected storage device:
ficient storage capacity to store the
• Is not used by other programs
• Is not write protected or read-only
3 - 16
To solve an error:
NY-series Industrial Panel PC User's Manual (W555)
Page 81
3 Software
(1) Check that the correct target disk was selected.
(2) Check that the target disk has sufficient storage capacity to store the rescue disk utility and a full
system backup
(3) If the storage device is removable, check that it is inserted properly and is of the correct type.
(4) Check whether the storage device is write protected. SD Memory Cards often have a small me-
chanical write protection switch on them.
(5) Check that the user has the necessary access rights for the target disk.
(6) Check that the Rescue Disk Creator is running "As Administrator".
(7) Check that no other applications are using the target disk.
(8) Retry the operation with the same target disk.
(9) Retry the operation with a different target disk.
(10) Restart the IPC and then retry the operation.
(11) If the issue persists, contact your OMRON representative.
3-2 Support Software
3
3-2-6 Rescue Disk Creator
NY-series Industrial Panel PC User's Manual (W555)
3 - 17
Page 82
A
B
AB
B
C
E
F
D
A
3 Software
3-2-7
Industrial PC Tray Utility
This section provides an overview of the Industrial PC Tray Utility.
Industrial PC Tray Utility Overview
The Industrial PC Tray Utility is a software utility that provides information about the current state of
the Industrial PC, its related devices, and associated software.
When running, the
area
Windows 10
of Windows.
Industrial PC Tray Utility is always present as a status icon
in the system tray
Features
The Industrial PC Tray Utility provides the following features:
•
Display the overall state of all installed OMRON utilities in the icon in the system tray area.
• Display a menu that can start all installed utilities and show the state of each installed utility.
• Display notification messages in popup windows that inform the user about the state of applications
or hardware. The Industrial PC Tray Utility displays the messages provided by installed OMRON
utilities. Refer to the OMRON utilities information for the messages that can be displayed.
Menu
Select the Industrial PC Tray Utility icon F to display the menu.
3 - 18
• The application displays the available utilities.
•
Select an entry to launch the associated utility, if applicable.
NY-series Industrial Panel PC User's Manual (W555)
Page 83
A
B
C
E
3 Software
• The icons of menu items in the Industrial PC Tray Utility menu will have a warning or error symbol
when applicable.
•
The Industrial PC Support Utility
•
The Industrial Monitor Utility
The Industrial Monitor Brightness Utility
•
The application area can be configured to show and launch both OMRON and third party utilities.
•
• The About entry
Refer to About the Industrial PC T
• The Exit entry
shows details of the Industrial PC Tray Utility.
closes the utility.
is available in the menu when installed.
is available in the menu when installed.
is available in the menu when installed.
ray Utility on page 3 - 19 for details.
About the Industrial PC Tray Utility
The About window shows the version of the Industrial PC Tray Utility and copyright information.
3-2 Support Software
3
3-2-7 Industrial PC Tray Utility
Status Indicators on Icons
The following table provides the indicator details of the Industrial PC Tray Utility.
Overlay typeIconDescription
NoneNo OMRON utility has issued warning or error notifications.
Warning signAt least one OMRON utility has issued a warning notification.
Error signAt least one OMRON utility has issued an error notification.
Compatibility
This software utility can be used on PCs with Windows 7 and Windows 10.
NY-series Industrial Panel PC User's Manual (W555)
3 - 19
Page 84
3 Software
The Industrial PC Tray Utility is pre-installed on an Industrial Box PC and an Industrial Panel PC.
The Industrial PC T
trial Monitor Utility. Install the Industrial PC Support Utility or Industrial Monitor Utility to install the In-
dustrial PC Tray Utility.
By default the Industrial PC Tray Utility is configured to start automatically at Windows startup.
T
Installation
ray Utility is included in the installers of the Industrial PC Support Utility and Indus-
Startup
o manually start the Industrial PC Tray Utility:
1Locate the Industrial PC Tray Utility using the Windows Start menu or the Windows search
box.
2Use the option Run as administrator to activate the Industrial PC T
Additional Information
The procedure to use Run as administrator is:
For Windows 10 using the Start menu:
•
Rightclick the Industrial PC Tray Utility, select More and then Run as administrator.
• For Windows 10 using Search:
Rightclick the Industrial PC Tray Utility in the search results and select Run asadministrator.
• For Windows 7 using the Start menu or Search:
Rightclick the Industrial PC Tray Utility and select Run as administrator.
The Industrial PC Tray Utility started.
ray Utility.
3 - 20
NY-series Industrial Panel PC User's Manual (W555)
Page 85
3 Software
3-2-8
Power Attendant Lite Utility
This section provides an overview of the Power Attendant Lite Utility (PAL).
Power Attendant Lite Utility Overview
The Power Attendant Lite Utility is a software utility that constantly monitors the status of the UPS that
is connected to the Panel PC
When the Power Attendant Lite Utility discovers a power interruption it will send a signal to the Panel
PC to shut down.
The manual UPS Power Attendant Lite for Windows User's Manual is available.
.
Features
The Power Attendant Lite Utility provides the following features:
•
Signal the Panel PC to shut down when a power interruption is detected.
• Configure the shutdown conditions when a power interruption is detected.
• Display the state of the connected UPS using the icon in the system tray area.
IconDescription
Normal operation
3-2 Support Software
3
3-2-8 Power Attendant Lite Utility
Power Attendant Lite service stopped
UPS is supplying power from the internal battery
Communication error
Compatibility
The Power Attendant Lite Utility can be used on a Panel PC with one of the following operating sys-
tems:
•
Windows 10
• Windows 7
Installation
The Power Attendant Lite Utility is not pre-installed on a Panel PC.
The Power Attendant Lite Utility
lers). Download the installer from the OMRON download website if required.
installer is included in the installers directory (D:/OMRON-NY/Instal-
To install the Power Attendant Lite Utility:
NY-series Industrial Panel PC User's Manual (W555)
3 - 21
Page 86
3 Software
The Power Attendant Lite Utility
Configure the Power Attendant Lite Utility before using the Panel PC with a UPS connected using
USB.
1Ensure the revision number of the UPS is correct.
Refer to 2-9-8 UPS on page
2 - 23 for details.
2Ensure the UPS is connected to the Panel PC with a USB cable.
Refer to 5-8-1
Connect UPS Using the USB Connector on page 5 - 52 for details.
3Open the Power Attendant Lite Utility installer folder and activate the installer file setup.exe.
4Follow the installer steps to complete the installation.
is installed.
Configuration
o configure the Power Attendant Lite Utility:
T
1Activate the icon of the Power Attendant Lite Utility to start the software.
A UPS selection window will be displayed.
2Select the connected UPS.
A Login window will be displayed.
3Login with ID Admin and password omron.
op window with UPS status information will be displayed.
The T
3 - 22
4Configure the parameters for your specific situation.
NY-series Industrial Panel PC User's Manual (W555)
Page 87
3 Software
3-2 Support Software
Refer to UPS Power Attendant Lite for W
indows User's Manual for details.
5Select Detailed Setting / Other Settings / Communication Setting / UPS Communication
to display the parameter COM search to UPS detection.
Port
6Set the parameter to Do not search for COM ports to prevent interference for the COM ports.
7Select Submit
to save the setting.
8Select the close button in the right top corner to exit the Power Attendant Lite Utility software.
9Select the restart behavior of the Panel PC with the Bios Boot Menu parameter Power Loss
Control.
Set this parameter to Turn On to restart automatically after a power down from the Power At-
tendant Lite Utility.
Refer to the Bios Boot Menu information for details.
10 Test the UPS shutdown behavior.
(1) Start the Panel PC
(2) Start applications
3
3-2-8 Power Attendant Lite Utility
(3) Create a power interruption
(4) Monitor the shutdown sequence and confirm a correct shutdown
When the shutdown sequence is not correct change parameters in the
Lite Utility software and test the UPS shutdown behavior again.
The Power Attendant Lite Utility is configured.
The Panel PC will shut down properly in case of a power supply interruption and restart automatically
when the power is restored.
NY-series Industrial Panel PC User's Manual (W555)
Power Attendant
3 - 23
Page 88
3 Software
3-3
3-3-1
Software for Developers
This section provides information on the software that is available for developers.
Overview IPC Developer Software for Windows
This section gives an overview of the software available for developers for all Industrial PC Platform
products with a Windows operating system.
ProductDeveloper software
Industrial MonitorIndustrial Monitor SDK
Industrial Monitor API
Industrial Box PCIndustrial PC System SDK
Industrial PC System API
Industrial Panel PCIndustrial Monitor SDK
Industrial Monitor API
Industrial PC System SDK
Industrial PC System API
Select and download the software required from the OMRON download website.
3 - 24
NY-series Industrial Panel PC User's Manual (W555)
Page 89
3 Software
3-3-2
Industrial PC System API
This section describes some of the Industrial PC System API functions.
The Industrial PC System API allows programmers to create programs that can retrieve information or
set an indicator status of the product.
The API makes use of the included OMRON IPC System Service to manage the hardware.
Features
The Industrial PC System API can:
•
Retrieve product information from the Industrial PC
• Retrieve system flags
• Retrieve maintenance information
• Configure and program the Watchdog
• Set the status of the Run LED Indicator and the ERR LED Indicator
*1 Only for
• Industrial Box PCs with a Windows operating system.
These are:
• NYB££-££1££
• NYB££-££2££
• NYB££-££3££
• Industrial Panel PCs with a Windows operating system.
These are:
• NYP££-££1££-££££££££
• NYP££-££2££-££££££££
• NYP££-££3££-££££££££
*1
*1
3-3 Software for Developers
3
3-3-2 Industrial PC System API
Installation
The Industrial PC System API is part of the SDK download.
The Industrial PC System API is pre-installed on the
Install the Industrial PC System SDK to use the Industrial PC System API on development PCs.
Use the Merge Module to include the Industrial PC System API in the installer for custom applications.
To use the Industrial PC System API the API needs to be referenced in your development project.
Industrial Panel PC and the Industrial Box PC.
NY-series Industrial Panel PC User's Manual (W555)
3 - 25
Page 90
3 Software
3-3-3
Industrial Monitor API
This section describes some of the Industrial Monitor API functions.
The Industrial Monitor API
features and retrieve information from connected Industrial Monitors.
The main function of the Industrial Monitor API is to enable the brightness of the backlight and the
LEDs of the monitor to be increased or decreased according to the working environment.
The API makes use of the included OMRON Industrial Monitor Service to manage the hardware.
allows programmers to create applications that can control the hardware
Features
For all connected Industrial Monitors, the Industrial Monitor API can:
•
Retrieve product information from the Industrial Monitor or Industrial Panel PC display
• Retrieve product status information
• Set the brightness of the Status LED indicator
• Set the brightness of the backlight
• Set the brightness of the Logo LED
• Set the touch points of the monitor
• Store settings
• Restore to factory defaults
The API makes use of the included Industrial Monitor Service to manage all Industrial Monitors con-
nected via USB.
Installation
The Industrial Monitor API is part of the SDK download.
The Industrial Monitor API
Install the Industrial Monitor SDK to use the Industrial Monitor API on development PCs.
Use the Merge Module to include the Industrial Monitor API in the installer for custom applications.
To use the Industrial Monitor API the API needs to be referenced in your development project.
is pre-installed on the Industrial Panel PC and Industrial Box PC.
3 - 26
NY-series Industrial Panel PC User's Manual (W555)
Page 91
Specifications
This section provides specifications of the Industrial Panel PC.
4
4
4-1
General Specifications ............................................................................... 4 - 2
4-1-1 Dimensions and Weight................................................................................ 4 - 2
4-1-2 General Electrical Specifications .................................................................. 4 - 3
4-1-3 Power Consumption Specifications .............................................................. 4 - 3
4-1-4 CPU Specifications ....................................................................................... 4 - 6
NY-series Industrial Panel PC User's Manual (W555)
4 - 1
Page 92
Z
Y
X
R
4 Specifications
4-1
4-1-1
General Specifications
This section provides general specifications of the Industrial Panel PC.
Dimensions and Weight
The following table provides specification details on dimensions and weights.
Item
DimensionsWidth X = 332 mm
Height Y = 234 mm
Depth Z = 121 mm
Monitor thickness in front of panelRim thickness R = 8.0 mm
Weight6.1 kg7.2 kg
*1.Refer to 1-4 Product Configuration on page
12.1 Inch
1 - 5 for product configuration details.
Model Specifications
*1
15.4 Inch
Width X = 401 mm
Height Y = 277 mm
Depth Z = 121 mm
*1
4 - 2
NY-series Industrial Panel PC User's Manual (W555)
Page 93
4 Specifications
4-1-2
General Electrical Specifications
The following table provides the general electrical specifications.
ItemSpecifications
Rated power supply voltage24 VDC
Allowable power supply voltage range20.4 to 28.8 VDC
Power supply standardSELV
Grounding methodGround to less than 100 Ω
Inrush currentAt 24 VDC: 12 A / 6 ms max. for cold start at room
temperature
Overvoltage categoryJIS B3502 and IEC 61131-2: Category II
EMC immunity levelIEC 61132-2: Zone B
RTC accuracyAt ambient temperature of 55°C: −3.5 to +0.5 min error
per month
At ambient temperature of 25°C: −1.5 to +1.5 min error
per month
At ambient temperature of 0°C: −3 to +1 min error per
month
Power button life100,000 operations
Fan life8 years of continuous operation at 40°C
Battery life5 years at 25°C (for battery CJ1W-BAT01)
4-1 General Specifications
4
4-1-2 General Electrical Specifications
4-1-3
Power Consumption Specifications
The following tables provide details on the power consumption of the Industrial Panel PC.
The total power consumption is the sum of the power consumption of all items that are installed in
your Panel PC.
Additional Information
Refer to 1-4 Product Configuration on page 1 - 5 for details.
Power Consumption with an Intel® Core™ i7-4700EQ CPU
Power consumption specifications for an Industrial Panel PC with an Intel® Core™ i7-4700EQ
Item
Industrial Panel PC with an Intel® Core™ i7-4700EQ
excluding Drives and Expansions.
*1
Drives
Expansions
*1.Refer to 1-4 Product Configuration on page
*2.Refer to the documentation of your expansions for their power consumption details.
*2
HDD 320 GB2 W
SSD SLC 32 GB
SSD SLC 64 GB
SSD iMLC 128 GB
USB14 W max. ((2 x 500 mA at 5 VDC) + (2 x 900 mA at 5
PCIe15 W max.
1 - 5 for product configuration details.
12.1 Inch models
99 W99 W
VDC))
Power consumption
*1
15.4 Inch models
CPU.
*1
NY-series Industrial Panel PC User's Manual (W555)
4 - 3
Page 94
4 Specifications
The total power consumption is the sum of the power consumption of all items that are installed in
your Industrial Panel PC
The required supply specifications for a Panel PC with an Intel® Core™ i7-4700EQ CPU.
Power supply
Refer to 2-9-7 Power Supply on page
supply products.
UPS
Refer to 2-9-8 UPS on page
Power Consumption with an Intel® Core™ i5-4300U CPU
Power consumption specifications for an Industrial Panel PC with an Intel® Core™ i5-4300U CPU.
.
ItemMinimum power requirements
240 W
2 - 22 for power
240 W
2 - 23 for UPS products.
Item
Industrial Panel PC with an Intel® Core™ i5-4300U
cluding Drives and Expansions.
*1
Drives
Expansions
*1.Refer to 1-4 Product Configuration on page
*2.Refer to the documentation of your expansions for their power consumption details.
*2
HDD 320 GB2 W
SSD SLC 32 GB
SSD SLC 64 GB
SSD iMLC 128 GB
USB14 W max. ((2 x 500 mA at 5 VDC) + (2 x 900 mA at 5
PCIe5 W max.
ex-
1 - 5 for product configuration details.
12.1 Inch models
70 W70 W
VDC))
Power consumption
*1
15.4 Inch models
The total power consumption is the sum of the power consumption of all items that are installed in
your
Industrial Panel PC.
The required supply specifications for a Panel PC with an Intel® Core™ i5-4300U CPU.
ItemMinimum power requirements
Power supply
Refer to 2-9-7 Power Supply on page
supply products.
UPS
Refer to 2-9-8 UPS on page
2 - 23 for UPS products.
2 - 22 for power
120 W
120 W
*1
4 - 4
Power Consumption with an Intel® Celeron®
2980U CPU
Power consumption specifications for an Industrial Panel PC with an Intel® Celeron® 2980U CPU.
Item
Industrial Panel PC with an Intel® Celeron® 2980U
cluding Drives and Expansions.
12.1 Inch models
63 W63 W
ex-
NY-series Industrial Panel PC User's Manual (W555)
Power consumption
*1
15.4 Inch models
*1
Page 95
4 Specifications
Item
*1
Drives
Expansions
*1.Refer to 1-4 Product Configuration on page
*2.Refer to the documentation of your expansions for their power consumption details.
*2
HDD 320 GB2 W
SSD SLC 32 GB
SSD SLC 64 GB
SSD iMLC 128 GB
USB14 W max. ((2 x 500 mA at 5 VDC) + (2 x 900 mA at 5
PCIe5 W max.
1 - 5 for product configuration details.
12.1 Inch models
VDC))
Power consumption
*1
15.4 Inch models
The total power consumption is the sum of the power consumption of all items that are installed in
your
Industrial Panel PC.
The required supply specifications for a Panel PC with an Intel® Celeron® 2980U CPU.
ItemMinimum power requirements
Power supply
Refer to 2-9-7 Power Supply on page
supply products.
UPS
Refer to 2-9-8 UPS on page
2 - 23 for UPS products.
2 - 22 for power
120 W
120 W
*1
4-1 General Specifications
4
4-1-3 Power Consumption Specifications
NY-series Industrial Panel PC User's Manual (W555)
4 - 5
Page 96
4 Specifications
4-1-4
CPU Specifications
This section gives the specifications of the CPUs that are available for the Industrial Panel PC.
Refer to 1-4
Intel®
CPU specifications for Industrial Panel PCs with an Intel® Core™ i7-4700EQ
Cores / Threads4 / 8
CPU base frequency2.4 GHz
Maximum turbo frequency3.4 GHz
Cache6 MB
Cooling detailsRequires active cooling (fan)
Drive bays (HDD/SSD)2
Graphics controllerIntel ® HD Graphics 4600. Up to two independent
Product Configuration on page 1 - 5 for product configuration details.
Core™ i7-4700EQ CPU Specifications
CPU.
ItemSpecifications
screens.
Additional Information
Refer to A-1-3 BIOS - Advanced on page A - 5 for turbo frequency details.
Intel® Core™ i5-4300U
CPU specifications for Industrial Panel PCs with an Intel® Core™ i5-4300U
ItemSpecifications
Cores / Threads2 / 4
CPU base frequency1.9 GHz
Maximum turbo frequency2.9 GHz
Cache3 MB
Cooling detailsPassive cooling (fanless)
Drive bays (HDD/SSD)2
Graphics controllerIntel ® HD Graphics 4400. Up to two independent
Additional Information
Refer to A-1-3 BIOS - Advanced on page A - 5 for turbo frequency details.
CPU Specifications
CPU.
screens.
4 - 6
NY-series Industrial Panel PC User's Manual (W555)
Page 97
4 Specifications
4-1-5
Intel®
Celeron® 2980U CPU Specifications
CPU specifications for Industrial Panel PCs with an Intel® Celeron® 2980U CPU.
ItemSpecifications
Cores / Threads2 / 2
CPU base frequency1.6 GHz
Maximum turbo frequency---
Cache2 MB
Cooling detailsPassive cooling (fanless)
Drive bays (HDD/SSD)1. Drive bay A.
Graphics controllerIntel ® HD Graphics. Up to two independent screens.
Memory Specifications
The following table provides specification details of the memory.
Item
Memory typeDDR3L
Package memory formatSO-DIMM
Serial Presence Detect (SPD)
*1.Refer to 1-4 Product Configuration on page
Speed grade1600 Mbps
CAS LatencyCL11
1 - 5 for product configuration details.
2 GB
*1
Model Specifications
*1
4 GB
8 GB
*1
4-1 General Specifications
4
4-1-5 Memory Specifications
Additional Information
The small outline dual in-line memory modules (SO-DIMM) cannot be added or replaced by
users.
NY-series Industrial Panel PC User's Manual (W555)
4 - 7
Page 98
4 Specifications
4-1-6
Storage Device Specifications
This section provides the specifications of the storage devices.
Hard Disk Drive Specifications
Specifications for the Hard Disk Drive (HDD) are provided in the table below.
Item
ModelNY000-AH00
S.M.A.R.T. supportYes
Rotation speed5,400 r/min
InterfaceSerial ATA 3.0
Operating temperature
Operating humidity
5 to 55°C
• 10% to 95% (with no condensation)
*2
• 29°C wet-bulb temperature max.
Storage temperature-40 to 65°C
Storage humidity
• 8% to 90% (with no condensation)
• 40°C wet-bulb temperature max.
LifeApproximately 5 years or 20,000 powered-ON hours
(whichever comes first) under the following conditions:
• 25°C at 101.3 kPa
• Less than 333 powered-ON hours/month
• Less than 20% operation while powered-ON
• Less than 1.30 x 10
*1.Refer to 1-4 Product Configuration on page
*2.Refer to 4-5-1 Operation Environment Specifications on page 4 - 25 for the temperature specifications of
the complete Panel PC
*3.Powered-ON hours include sleep and standby modes.
*4.Operation includes seeking, writing, and reading functions.
1 - 5 for product configuration details.
Model Specifications
320 GB
6
seeks/month
*1
*3
*4
4 - 8
Solid State Drive Specifications
Specifications for the Solid State Drive (SSD) are provided in the table below.
Item
ModelNY000-AS00NY000-AS01NY000-AS02
TypeSLCSLCiMLC
S.M.A.R.T. supportYes
InterfaceSerial ATA 3.1
Sustained read speedUp to 160 MB/sUp to 430 MB/s
Sustained write speedUp to 150 MB/sUp to 190 MB/s
Operating temperature
Operating humidity10% to 95% (with no condensation)
Storage temperature-40 to 100°C
Storage humidity10% to 95% (with no condensation)
0 to 70°C
32 GB
*2
*1
Model Specifications
*1
64 GB
NY-series Industrial Panel PC User's Manual (W555)
128 GB
*1
Page 99
4 Specifications
Item
Life1500 TB/11 years at a
daily workload of 350 GB
*1.Refer to 1-4 Product Configuration on page 1 - 5 for product configuration details.
*2.Refer to 4-5-1 Operation Environment Specifications on page 4 - 25 for the temperature specifications of
the complete Panel PC
32 GB
*1
Model Specifications
*1
64 GB
3000 TB/23 years at a
daily workload of 350 GB
128 GB
114 TB/3 years at a daily
workload of 100 GB
*1
4-1 General Specifications
4
4-1-6 Storage Device Specifications
NY-series Industrial Panel PC User's Manual (W555)
4 - 9
Page 100
A
A
4 Specifications
4-1-7
PCIe Card Specifications
The PCI Express (PCIe) Card slot of the Industrial Panel PC accepts various cards for specific hard-
ware needs.
Ensure that, according to the PCIe hardware specifications, the indent
The following tables provide PCIe Card details per CPU type.
is present in the PCIe Card.
PCIe Card Slot Specifications with an Intel® Core™ i7-4700EQ CPU
The table below provides PCIe Card slot details for Industrial Panel PCs with an Intel® Core