Omron NX-SL3300, NX-SL3500, NX-SL5500, NX-SIH800, NX-SOH200 User Manual

...
Page 1
Machine Automation Controller
NX-series
Safety Control Unit
User's Manual
NX-SL££££ NX-SI££££ NX-SO££££
Safety Control Unit
Page 2
NOTE
(1) All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or
transmitted, in any form, or by any means, mechanical, electronic, photocopying, recording, or otherwise, without the prior written permission of OMRON.
(2) No patent liability is assumed with respect to the use of the information contained herein.
Moreover, because OMRON is constantly striving to improve its high-quality products, the infor­mation contained in this manual is subject to change without notice.
Every precaution has been taken in the preparation of this manual. Nevertheless, OMRON as-
(3)
sumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained in this publication.
Trademarks
Sysmac and SYSMAC are trademarks or registered trademarks of OMRON Corporation in Japan
and other countries for OMRON factory automation products.
Microsoft, Windows, Windows Vista, Excel, and V
trademarks of Microsoft Corporation in the United States and other countries.
EtherCAT
GmbH, Germany.
Safety over EtherCAT
Automation GmbH, Germany.
®
is registered trademark and patented technology, licensed by Beckhoff Automation
®
is a registered trademark and a patented technology licensed by Beckhoff
isual Basic are either registered trademarks or
ODVA, CIP, CompoNet, DeviceNet, EtherNet/IP, and CIP Safety are trademarks of ODVA.
The SD and SDHC logos are trademarks of SD-3C, LLC.
Other company names and product names in this document are the trademarks or registered trade­marks of their respective companies.
Copyrights
Microsoft product screen shots reprinted with permission from Microsoft Corporation.
This product incorporates certain third party software. The license and copyright information associ-
ated with this software is available at http://www
.fa.omron.co.jp/nj_info_e/.
Page 3

Introduction

Thank you for purchasing an NX-series Safety Control Unit. This manual contains information that is necessary to use the NX-series Safety Control Unit. Please read this manual and make sure you understand the functionality and performance of the Unit before you attempt to use it in a control system. Keep this manual in a safe place where it will be available for reference during operation.

Intended Audience

This manual is intended for the following personnel, who must also have knowledge of electrical sys­tems (an electrical engineer or the equivalent).
• Personnel in charge of introducing FA systems.
• Personnel in charge of designing FA systems.
• Personnel in charge of installing and maintaining FA systems.
• Personnel in charge of managing FA systems and facilities.
• Personnel with the qualifications, authority, and responsibility for providing safety at each phase of the lifecycle of the machine: design, installation, operation, maintenance, and disposal.
• Personnel with a knowledge of functional safety.
For programming, this manual is intended for personnel who understand the programming language specifications in international standard IEC 61131-3 or Japanese standard JIS B 3503.
Introduction

Applicable Products

This manual covers the following products.
• NX-series Safety Control Units NX-SL££££ NX-SI££££ NX-SO££££
Note that this manual provides information for using an NX-series Safety Control Unit described above together with an NJ/NX-series CPU Unit, an EtherCAT Coupler Unit, or with an EtherNet/IP Coupler Unit. When you use it with an NX-CSG320 Communication Control Unit, refer to the NX-series Safety Control Unit / Communication Control Unit User's Manual (Cat. No. Z395).
NX-series Safety Control Unit User's Manual (Z930)
1
Page 4
Introduction
2
NX-series Safety Control Unit User's Manual (Z930)
Page 5

Sections in this Manual

1 10
2
3
4
5
6
7
8
9
1
10
2
3
11
12
4
13
5 A
6 I
8
9
Overview
Specifications
Safety Unit Restore
Installation and Wiring
Safety Control Unit Operation
Programming
12
Troubleshooting
System Configuration and Setup
11
Safety Data Logging
A
Appendices
I
Index
13
Inspection and Maintenance
Checking Operation and Actual Operation
Calculating Safety Reaction Times
Communications Load
7
Sections in this Manual
NX-series Safety Control Unit User's Manual (Z930)
3
Page 6

CONTENTS

CONTENTS
Introduction .............................................................................................................. 1
Intended Audience...........................................................................................................................................1
Applicable Products
Sections in this Manual ........................................................................................... 3
Relevant Manuals................................................................................................... 11
Manual Structure.................................................................................................... 13
Page Structure...............................................................................................................................................13
Special Information ........................................................................................................................................ 14
Precaution on Terminology ............................................................................................................................14
Terms and Conditions Agreement........................................................................ 15
Warranty, Limitations of Liability ....................................................................................................................15
Application Considerations ............................................................................................................................16
Disclaimers ....................................................................................................................................................16
.........................................................................................................................................1
Safety Precautions................................................................................................. 18
Definition of Precautionary Information..........................................................................................................18
Symbols ......................................................................................................................................................... 18
Warnings........................................................................................................................................................19
Precautions for Safe Use ...................................................................................... 24
Precautions for Correct Use ................................................................................. 29
Regulations and Standards .................................................................................. 31
Conformance to EU Directives ......................................................................................................................31
Conformance to EN ISO 13849-1 and EN 62061..........................................................................................32
Conformance to UL and CSA Standards.......................................................................................................33
Conformance to Shipbuilding Standards .......................................................................................................33
Conformance to KC Certification ...................................................................................................................33
Unit Versions.......................................................................................................... 35
Unit Versions..................................................................................................................................................35
Unit Versions of Units and Sysmac Studio Versions......................................................................................36
Related Manuals..................................................................................................... 37
Terminology............................................................................................................ 39
Revision History..................................................................................................... 42
Section 1 Overview
1-1 Introduction and Features...................................................................................................1 - 2
1-1-1 Overview of Safety Control Unit
1-1-2 Features of Safety Control Unit.................................................................................................1 - 5
1-2 System Configuration and Configuration Devices ........................................................... 1 - 8
1-2-1 Safety Control System Configuration on NX bus of CPU Unit or EtherCAT Network ...............1 - 8
1-2-2 Safety Control System Configuration on EtherNet/IP Network ...............................................1 - 10
1-2-3 Standalone Safety Control System Configuration...................................................................1 - 10
4
................................................................................................1 - 2
NX-series Safety Control Unit User's Manual (Z930)
Page 7
1-2-4 Types of Safety Control Unit ...................................................................................................1 - 11
1-3 Support Software
1-3-1 Applicable Support Software...................................................................................................1 - 12
1-3-2 Connection Method and Procedures for EtherCAT Coupler Units ..........................................1 - 12
1-3-3 Connection Method and Procedures for EtherNet/IP Coupler Units .......................................1 - 14
...............................................................................................................1 - 12
1-4 Commissioning Procedures .............................................................................................1 - 15
1-4-1 Overall Procedure ...................................................................................................................1 - 15
1-4-2 Detailed Procedures................................................................................................................1 - 16
Section 2 Specifications
2-1 Safety CPU Unit....................................................................................................................2 - 2
2-1-1 Models and Specifications
2-1-2 Part Names and Functions........................................................................................................2 - 8
2-1-3 Indicators.................................................................................................................................2 - 10
2-2 Safety Input Unit ................................................................................................................2 - 16
2-2-1 Models and Specifications ......................................................................................................2 - 16
2-2-2 Part Names and Functions......................................................................................................2 - 22
2-2-3 Indicators.................................................................................................................................2 - 24
2-3 Safety Output Unit .............................................................................................................2 - 28
2-3-1 Models and Specifications ......................................................................................................2 - 28
2-3-2 Part Names and Functions......................................................................................................2 - 35
2-3-3 Indicators.................................................................................................................................2 - 38
2-4 PFH......................................................................................................................................2 - 41
CONTENTS
........................................................................................................2 - 2
Section 3 Installation and Wiring
3-1 Installing Units .....................................................................................................................3 - 2
3-1-1 Installing NX Units
3-1-2 Attaching Markers .....................................................................................................................3 - 4
3-1-3 Removing Units.........................................................................................................................3 - 5
3-1-4 Installation Orientation ..............................................................................................................3 - 6
.....................................................................................................................3 - 2
3-2 Power Supply Types and Wiring ........................................................................................3 - 8
3-2-1 Applications of I/O Power Supply and Supply Methods ............................................................3 - 8
3-2-2 Calculating the Total Current Consumption from I/O Power Supply .........................................3 - 9
3-3 Wiring the Terminals..........................................................................................................3 - 10
3-3-1 Wiring to the Screwless Clamping Terminal Blocks ................................................................3 - 10
3-3-2 Checking Wiring ......................................................................................................................3 - 23
Section 4 Safety Control Unit Operation
4-1 Relationship between Units and Types of Communications...........................................4 - 2
4-1-1 Safety Control System on CPU Rack or EtherCAT Network.....................................................4 - 2
4-1-2 Safety Control System on EtherNet/IP Network........................................................................4 - 4
4-1-3 Standalone Safety Control System ...........................................................................................4 - 6
4-2 I/O System ............................................................................................................................4 - 8
4-2-1 Relationship between the Types of Signals and the Types of Communications.......................4 - 8
4-2-2 Safety Data Types and Standard Data Types...........................................................................4 - 8
4-2-3 Specifying Safety Data Types and Standard Data Types .........................................................4 - 9
4-3 Safety I/O Function ............................................................................................................4 - 10
4-3-1 Safety Input Function ..............................................................................................................4 - 10
4-3-2 Safety Output Function ...........................................................................................................4 - 32
NX-series Safety Control Unit User's Manual (Z930)
5
Page 8
CONTENTS
Section 5 System Configuration and Setup
5-1 Configuration and Setup Procedures ................................................................................5 - 2
5-2 Part Names and Functions of the Sysmac Studio W
5-3 Controller Configuration and Setup of the Safety Control Units ....................................5 - 5
5-3-1 Procedures for Creating the Controller Configuration for Safety Control ..................................5 - 6
5-3-2 Setting and Viewing the Safety Control Unit Settings ...............................................................5 - 9
5-3-3 Procedure to Change the Model of the Safety Control Unit ....................................................5 - 10
5-4 Setting Up the Safety Process Data Communications...................................................5 - 12
5-4-1 Setting Up the FSoE Communications....................................................................................5 - 12
5-4-2 Setting Up the CIP Safety Communications ...........................................................................5 - 13
5-4-3 Calculating the Number of Connections..................................................................................5 - 20
5-5 Safety I/O Functions ..........................................................................................................5 - 23
5-6 Registering Device Variables............................................................................................5 - 26
5-7 Exposing Variables to Standard Controllers...................................................................5 - 30
5-7-1 Exposing Global Variables ......................................................................................................5 - 30
5-7-2 Setting Exposed Variables ......................................................................................................5 - 31
5-7-3 Safety CPU Unit Status...........................................................................................................5 - 35
5-7-4 I/O Ports for Safety I/O Units...................................................................................................5 - 36
5-7-5 I/O Refreshing Method ............................................................................................................5 - 36
5-8 Setting Standard Process Data Communications ..........................................................5 - 37
5-8-1 Using an CPU Unit or EtherCAT Coupler Unit ........................................................................5 - 37
5-8-2 Using an EtherNet/IP Coupler Unit .........................................................................................5 - 37
5-9 Exporting/Importing Settings Data...................................................................................5 - 39
5-9-1 Exporting/Importing the Settings for the Entire Slave Terminal...............................................5 - 39
5-9-2 Exporting/Importing the Settings for All the NX Units on a CPU Rack or Slave Terminal.......5 - 41
5-9-3 Exporting/Importing Data for Individual Safety CPU Unit........................................................5 - 42
indow .............................................5 - 3
Section 6 Programming
6-1 POUs (Program Organization Units) .................................................................................. 6 - 3
6-1-1 POU
6-1-2 Overview of the Three Types of POUs......................................................................................6 - 3
6-1-3 Differences between Programs, Functions, and Function Blocks.............................................6 - 4
6-1-4 Details on Programs..................................................................................................................6 - 5
6-1-5 Details on Function Blocks........................................................................................................6 - 6
6-1-6 Details on Functions................................................................................................................6 - 10
6-1-7 Instructions..............................................................................................................................6 - 11
6-2 Variables .............................................................................................................................6 - 12
6-2-1 Variables..................................................................................................................................6 - 12
6-2-2 Types of Variables ...................................................................................................................6 - 12
6-2-3 Type of User-defined Variable .................................................................................................6 - 12
6-2-4 Attributes of Variables .............................................................................................................6 - 13
6-2-5 Data Type................................................................................................................................6 - 14
6-2-6 Variable Attributes Other Than Data Type...............................................................................6 - 16
6-2-7 Function Block Instances ........................................................................................................6 - 17
6-2-8 Restrictions on Variable Names and Other Safety Program-related Names...........................6 - 17
6-3 Constants (Literals) ...........................................................................................................6 - 19
6-3-1 Constants ................................................................................................................................6 - 19
6-3-2 Types of Constants .................................................................................................................6 - 19
6-4 Programming Languages..................................................................................................6 - 21
6-4-1 Programming Languages........................................................................................................6 - 21
6-4-2 FBD Language ........................................................................................................................6 - 21
6-5 Programming Operations..................................................................................................6 - 26
6-5-1 Programming Layer on the Sysmac Studio.............................................................................6 - 26
..........................................................................................................................................6 - 3
6
NX-series Safety Control Unit User's Manual (Z930)
Page 9
CONTENTS
6-5-2 Registering POUs ...................................................................................................................6 - 27
6-5-3 Registering V
6-5-4 FBD Programming ..................................................................................................................6 - 41
6-5-5 Function Block Conversion for Programs................................................................................6 - 60
6-5-6 Building ..................................................................................................................................6 - 61
6-5-7 Searching and Replacing ........................................................................................................6 - 63
6-5-8 Safety Task Settings................................................................................................................6 - 66
6-6 Automatic Programming ................................................................................................... 6 - 68
6-6-1 Generation Algorithms for Automatic Programming................................................................6 - 68
6-6-2 Automatic Programming Settings............................................................................................6 - 71
6-6-3 Automatic Programming Execution Procedure .......................................................................6 - 74
6-7 Monitoring Memory Usage for Safety Control Unit ........................................................6 - 77
6-8 Offline Debugging..............................................................................................................6 - 79
6-8-1 Offline Safety Program Debugging..........................................................................................6 - 79
6-8-2 Monitoring ...............................................................................................................................6 - 82
6-8-3 Controlling BOOL Variables, Changing Present Values, and Using Forced Refreshing.........6 - 82
6-8-4 Setting the Initial Values of Variables......................................................................................6 - 82
6-8-5 Feedback Settings ..................................................................................................................6 - 83
6-8-6 Simple Automatic Test.............................................................................................................6 - 84
ariables ..............................................................................................................6 - 36
Section 7 Checking Operation and Actual Operation
7-1 Procedures before Operation and Transferring the Required Data................................7 - 3
7-1-1 Commissioning Procedure
7-1-2 Data That You Must Transfer before Operation and Data Transfer Procedures .......................7 - 4
7-2 Transferring the Configuration Information ...................................................................... 7 - 7
7-2-1 Overview ...................................................................................................................................7 - 7
7-2-2 Transfer Procedure for a Connection to NJ/NX-series CPU Unit..............................................7 - 8
7-2-3 Transfer Procedure for a Connection to Communications Coupler Unit ...................................7 - 8
7-3 Operating Modes of the Safety CPU Unit ........................................................................7 - 11
7-3-1 Startup Operating Mode and Changing the Operating Mode.................................................. 7 - 11
7-3-2 Operation When Changing Operating Mode...........................................................................7 - 13
7-3-3 Executable Functions in Each Mode of the Safety CPU Unit..................................................7 - 14
7-4 Changing to DEBUG Mode................................................................................................7 - 17
7-5 Checking External Device Wiring.....................................................................................7 - 20
7-5-1 Overview of Functions for Checking Wiring ............................................................................7 - 20
7-5-2 Monitoring Safety I/O Units .....................................................................................................7 - 20
7-5-3 Troubleshooting Safety I/O Terminals .....................................................................................7 - 24
7-5-4 Clear All Memory Operation for Safety I/O Units ....................................................................7 - 25
7-6 Functions for Checking Operation...................................................................................7 - 27
7-6-1 Overview of Functions for Checking Operation.......................................................................7 - 27
7-6-2 Starting and Stopping the Safety Programs in DEBUG Mode ................................................7 - 27
7-6-3 Monitoring Variables in the FBD Editor ...................................................................................7 - 28
7-6-4 Monitoring Variables in a Watch Tab Page..............................................................................7 - 29
7-6-5 Controlling BOOL Variables, Changing Present Values, and Using Forced Refreshing.........7 - 31
7-7 Online Functional Test ......................................................................................................7 - 40
7-7-1 Online Functional Test Settings...............................................................................................7 - 40
7-7-2 Online Functional Test Execution Procedure ..........................................................................7 - 44
7-8 Node Name .........................................................................................................................7 - 50
7-9 Security Settings................................................................................................................7 - 51
7-9-1 Setting the Safety Password ...................................................................................................7 - 51
7-9-2 Data Protection .......................................................................................................................7 - 52
7-10 Performing Safety Validation and Operation...................................................................7 - 56
7-10-1 Performing Safety Validation...................................................................................................7 - 56
7-10-2 Changing to RUN Mode ..........................................................................................................7 - 57
7-10-3 Changing to PROGRAM Mode ...............................................................................................7 - 58
........................................................................................................7 - 3
NX-series Safety Control Unit User's Manual (Z930)
7
Page 10
CONTENTS
7-11 Uploading Configuration Information and Safety Application Data .............................7 - 60
7-11-1
7-11-2 Uploading Data for a Connection to an NJ/NX-series CPU Unit.............................................7 - 60
7-11-3 Uploading Data for a Connection to a Communications Coupler Unit ....................................7 - 61
Outline.....................................................................................................................................7 - 60
7-12 Transferring Safety Application Data...............................................................................7 - 63
7-13 Monitoring Controller Status ............................................................................................7 - 64
7-14 Restarting and Clearing All Memory ................................................................................ 7 - 66
7-14-1 Restarting................................................................................................................................7 - 66
7-14-2 Clear All Memory Operation....................................................................................................7 - 67
Section 8 Calculating Safety Reaction Times
8-1 Safety Reaction Time...........................................................................................................8 - 2
8-1-1 Calculating the Safety Reaction T
8-1-2 Verifying Safety Reaction Times ...............................................................................................8 - 4
8-2 Safety Task ...........................................................................................................................8 - 5
8-2-1 Safety Task................................................................................................................................8 - 5
8-2-2 Operation of Safety Task...........................................................................................................8 - 5
8-2-3 Minimum Safety Task Period.....................................................................................................8 - 5
8-2-4 Setting the Safety Task Period..................................................................................................8 - 7
8-3 FSoE Watchdog Timer.........................................................................................................8 - 9
8-3-1 FSoE Watchdog Timers ............................................................................................................8 - 9
8-3-2 Checking FSoE Watchdog Timers ............................................................................................8 - 9
8-3-3 Settings for FSoE Watchdog Timers .......................................................................................8 - 10
8-3-4 Changing FSoE Watchdog Timers..........................................................................................8 - 10
8-4 EPI (Data Packet Interval).................................................................................................. 8 - 11
8-4-1 Changing the EPI .................................................................................................................... 8 - 11
8-4-2 EPI Restrictions....................................................................................................................... 8 - 11
ime .......................................................................................8 - 2
Section 9 Communications Load
9-1 Adjusting the Communications Load ................................................................................9 - 2
9-1-1 Checking Bandwidth Usage for T
9-1-2 Checking the Device Bandwidth Usage of the CIP Safety Routing ..........................................9 - 4
9-1-3 Relationship between the Number of Packets Used per Second and Packet Intervals............9 - 5
9-1-4 Adjusting the Device Bandwidth Usage ....................................................................................9 - 5
ag Data Links ........................................................................9 - 3
Section 10 Safety Unit Restore
10-1 Safety Unit Restore............................................................................................................10 - 2
10-1-1 Generate Safety Unit Restore File Function ...........................................................................10 - 2
10-1-2 Safety Unit Restore Function ..................................................................................................10 - 3
10-1-3 Specifications of a Safety Unit Restore File ............................................................................10 - 6
Section 11 Safety Data Logging
11-1 Outline of the Safety Data Logging Function.................................................................. 11 - 2
Creating a Safety Data Logging Settings File with the Sysmac Studio........................ 11 - 4
11-2
11-3 Safety Data Logging Operation Procedure .....................................................................11 - 6
11-4 Checking the Logging Status ........................................................................................... 11 - 7
11-4-1 Checking the Seven-segment Indicator ..................................................................................11 - 7
11-4-2 Checking with System-defined Variables ................................................................................11 - 7
8
NX-series Safety Control Unit User's Manual (Z930)
Page 11
11-5 Log File Specifications......................................................................................................11 - 8
Section 12 Troubleshooting
12-1 How to Check for Errors....................................................................................................12 - 2
12-2 Checking for Errors with the Indicators
12-2-1 Troubleshooting the Main Errors in the Safety CPU Unit........................................................12 - 3
12-2-2 Troubleshooting the Main Errors in the Safety I/O Units.......................................................12 - 11
12-3 Checking for Errors with the Sysmac Studio................................................................12 - 14
12-3-1 Checking for Errors from the Sysmac Studio ........................................................................12 - 14
12-3-2 Types of Errors......................................................................................................................12 - 15
12-3-3 Event Codes for Errors and Troubleshooting Procedures.....................................................12 - 17
12-3-4 Error Descriptions .................................................................................................................12 - 31
12-4 Resetting Errors...............................................................................................................12 - 90
12-5 Troubleshooting Flow When Errors Occur....................................................................12 - 91
CONTENTS
..........................................................................12 - 3
Section 13 Inspection and Maintenance
13-1 Cleaning and Inspection ...................................................................................................13 - 2
13-1-1 Cleaning
13-1-2 Periodic Inspections ................................................................................................................13 - 2
..................................................................................................................................13 - 2
13-2 Maintenance Procedures ..................................................................................................13 - 5
13-2-1 Replacing the Safety CPU Unit ...............................................................................................13 - 5
13-2-2 Replacing Safety I/O Units ......................................................................................................13 - 7
Appendices
A-1 Dimensions.......................................................................................................................... A - 3
A-1-1 Safety CPU Unit ....................................................................................................................... A - 3
A-1-2 Safety I/O Units ........................................................................................................................ A - 4
A-2 NX Objects ........................................................................................................................... A - 5
A-2-1 Format of NX Object Descriptions............................................................................................ A - 5
A-2-2 Safety CPU Unit (NX-SL3300/NX-SL3500) ............................................................................. A - 5
A-2-3 Safety CPU Unit (NX-SL5500/NX-SL5700) ............................................................................. A - 7
A-2-4 NX-SID800 Safety Input Unit ..................................................................................................A - 11
A-2-5 NX-SIH400 Safety Input Unit ................................................................................................. A - 16
A-2-6 NX-SOD400 Safety Output Unit............................................................................................. A - 21
A-2-7 NX-SOH200 Safety Output Unit............................................................................................. A - 25
A-3 Application Examples....................................................................................................... A - 30
A-3-1 Emergency Stop Pushbutton Switches .................................................................................. A - 30
A-3-2 Safety Doors .......................................................................................................................... A - 32
A-3-3 Safety Laser Scanners........................................................................................................... A - 36
A-3-4 Safety Door Switches with Magnetic Locks and Key Selector Switches................................ A - 39
A-3-5 Enable Switches..................................................................................................................... A - 43
A-3-6 Two-hand Switches................................................................................................................ A - 47
A-3-7 D40A Non-contact Door Switches.......................................................................................... A - 50
A-3-8 D40Z Non-contact Door Switches.......................................................................................... A - 53
A-3-9 Safety Mats and Safety Light Curtains................................................................................... A - 56
A-3-10 Safety Edges.......................................................................................................................... A - 61
A-3-11 Single Beam Safety Sensor ................................................................................................... A - 63
A-3-12 Multi-axis Servo Drives (STO)................................................................................................ A - 66
A-4 Change Tracking ............................................................................................................... A - 70
A-5 Safety CPU Unit Status..................................................................................................... A - 72
A-5-1 NX-SL3300/NX-SL3500 ......................................................................................................... A - 72
A-5-2 NX-SL5500/NX-SL5700 ......................................................................................................... A - 72
NX-series Safety Control Unit User's Manual (Z930)
9
Page 12
CONTENTS
A-6 I/O Ports of Safety I/O Units ............................................................................................. A - 74
A-7 CIP Response Codes ........................................................................................................ A - 81
A-8 Icon list for Safety Slave Unit Parameters ...................................................................... A - 86
A-9 Calculating I/O Sizes for CPU Rack or Slave Terminals................................................ A - 93
A-10 Printing .............................................................................................................................. A - 94
A-11 List of Screwless Clamping Terminal Block Models ..................................................... A - 96
A-12 I/O Response Times for Communications between NX Units on EtherNet/IP
A-13 Units That Support Communications between NX Units ............................................ A - 100
A-14 Checking the Signature Code on the Seven-segment Indicator ................................ A - 101
A-15 Execution Scenarios for the Simple Automatic Test................................................... A - 102
A-16 Differences in Checking Operation between the Simulator and Safety CPU Unit.... A - 104
A-17 Version Information ........................................................................................................ A - 105
A-6-1 NX-SIH400 Safety Input Unit
A-6-2 NX-SID800 Safety Input Unit ................................................................................................. A - 76
A-6-3 NX-SOH200 Safety Output Unit............................................................................................. A - 77
A-6-4 NX-SOD400 Safety Output Unit............................................................................................. A - 78
A-7-1 General Status Codes............................................................................................................ A - 81
A-7-2 Extended Status Codes ......................................................................................................... A - 83
A-8-1 External Device Icons for Input Devices ................................................................................ A - 86
A-8-2 Contact Icons for Input Devices ............................................................................................. A - 89
A-8-3 External Device Icons for Output Devices.............................................................................. A - 91
A-8-4 Contact Icons for Output Devices .......................................................................................... A - 92
A-10-1 Selecting the Items to Print .................................................................................................... A - 94
A-10-2 Items that are Printed............................................................................................................. A - 94
A-11-1 Model Notation ....................................................................................................................... A - 96
A-11-2 List of Terminal Block Models................................................................................................. A - 96
................................................................................................. A - 74
Slave Terminals................................................................................................................. A - 98
A-17-1 Relationship between Unit Versions and Sysmac Studio Versions...................................... A - 105
A-17-2 Functions That Were Added or Changed for Each Version ................................................. A - 109
Index
10
NX-series Safety Control Unit User's Manual (Z930)
Page 13

Relevant Manuals

The following table provides the relevant manuals for this product. Read all of the manuals that are relevant to your system configuration and application before you use the product. Most operations on this product are performed from the Sysmac Studio Automation Software. For de­tails on the Sysmac Studio, refer to the Sysmac Studio Version 1 Operation Manual (Cat. No. W504).
Purpose of use
NX-series
Safety Control Unit
User's Manual
User's Manual
Relevant Manuals
NX-series
Safety Control Unit /
Communication Control Unit
NX-series
Communication Control Unit
Built-in Function User's Manual
NX-series
Safety Control Unit
Instructions Reference Manual
Building a safety control system integrated with NJ/NX-ser­ies CPU Units
Building a standalone safety control system with EtherNet/IP Coupler Units
Building a safety network control system with Communica­tion Control Units
Introduction to Safety Control Unit Setting devices and hardware
NX-SL5£££ Safety CPU Unit NX-SL3£££ Safety CPU Unit NX-SI££££ and NX-SO££££ Safety I/O Units NX-CSG£££ Communication Control Unit
Software settings
NX-SL5£££ Safety CPU Unit NX-SL3£££ Safety CPU Unit NX-SI££££ and NX-SO££££ Safety I/O Units
NX-CSG£££ Communication Control Unit Creating safety programs Testing operation and debugging
Safety programs
Safety process data communications
Safety I/O functions
Tag data links
Built-in functions for Communication Control Unit Learning about error corrections
NX-SL5£££ Safety CPU Unit
NX-SL3£££ Safety CPU Unit
NX-SI££££ and NX-SO££££ Safety I/O Units
NX-CSG£££ Communication Control Unit Maintenance
l
l
l
l l
l l
l
l l
l
l l
l
l l
l l
l l l
l l l
l l
l l
l
l l
l l l
l l
l l
l
NX-series Safety Control Unit User's Manual (Z930)
11
Page 14
Relevant Manuals
Purpose of use
NX-series
Safety Control Unit
User's Manual
User's Manual
NX-series
Safety Control Unit /
Communication Control Unit
NX-series
Communication Control Unit
Built-in Function User's Manual
NX-series
Safety Control Unit
Instructions Reference Manual
NX-SL5£££ Safety CPU Unit NX-SL3£££ Safety CPU Unit NX-SI££££ and NX-SO££££ Safety I/O Units NX-CSG£££ Communication Control Unit
l l
l
l l
l
12
NX-series Safety Control Unit User's Manual (Z930)
Page 15

Manual Structure

4-9
4 Installation and Wir
ing
NJ-series CPU Unit Hardware User’s Manual (W500)
s
t
i
n
U
gnitn
u
oM
3-4
4
s
t
ne
no
p
m
o
C
rel
l
o
r
t
n
oC
g
n
i
tc
e
n
noC
1
-
3-
4
4-3 Mounting Units
The Units that make up an NJ-series Controller can be connected simply by pressing the Units together and locking the sliders by moving them toward the back of the Units. The End Cover is connected in the same way to the Unit on the far right side of the Controller.
1 Join the Units so that the conn ectors fit exactly.
2 The yellow sliders at the top and bottom of each Unit lock the Units together. Move the sliders
toward the back of the Units as shown below until they click into place.
Precautions for Correct UsePrecautions for Correct Use
4-3-1 Connecting Controller Components
Connector
Hook
Hook holes
Slider
Lock
Release
Move the sliders toward the back until they lock into place.
Level 1 heading Level 2 heading Level 3 heading
Level 2 heading
A step in a procedure
Manual name
Special information
Level 3 heading
Page tab
Gives the current headings.
Indicates a procedure.
Icons indicate precautions, additional information, or reference information.
Gives the number of the main section.
This illustration is provided only as a sample. It may not literally appear in this manual.
The sliders on the tops and bottoms of the Power Supply Unit, C
PU Unit, I/O Units, Special I/O Units, and CPU Bus Units must be completely locked (until they click into place) after connecting the adjacent Unit connectors.

Page Structure

The following page structure is used in this manual.
Manual Structure
NX-series Safety Control Unit User's Manual (Z930)
13
Page 16
RightLeft
Up
Down
Manual Structure

Special Information

Special information in this manual is classified as follows:
Precautions for Safe Use
Precautions on what to do and what not to do to ensure safe usage of the product.
Precautions for Correct Use
Precautions on what to do and what not to do to ensure proper operation and performance.
Additional Information
Additional information to read as required. This information is provided to increase understanding or make operation easier.
Version Information
Information on dif and for dif
ferent versions of the Sysmac Studio is given.
ferences in specifications and functionality for Controller with different unit versions

Precaution on Terminology

In this manual, the directions in relation to the Units are given in the following figure, which shows up­right installation.
14
NX-series Safety Control Unit User's Manual (Z930)
Page 17

Terms and Conditions Agreement

Terms and Conditions Agreement

Warranty, Limitations of Liability

Warranties
Exclusive Warranty
l
Omron’s exclusive warranty is that the Products will be free from defects in materials and work­manship for a period of twelve months from the date of sale by Omron (or such other period ex­pressed in writing by Omron). Omron disclaims all other warranties, express or implied.
Limitations
l
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right.
Buyer Remedy
l
Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-com­plying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be re­sponsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Compa­nies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CON­SEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY
NX-series Safety Control Unit User's Manual (Z930)
15
Page 18
Terms and Conditions Agreement
WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
, NEGLIGENCE OR STRICT LIABILITY.

Application Considerations

Suitability of Use
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’ er’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the par­ticular Product with respect to Buyer’s application, product or system. Buyer shall take application re­sponsibility in all cases.
s application or use of the Product. At Buy-
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIP­MENT OR SYSTEM.
Programmable Products
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof.

Disclaimers

Performance Data
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’ formance is subject to the Omron’s Warranty and Limitations of Liability.
s test conditions, and the user must correlate it to actual application requirements. Actual per-
16
Change in Specifications
Product specifications and accessories may be changed at any time based on improvements and oth­er reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may
NX-series Safety Control Unit User's Manual (Z930)
Page 19
Terms and Conditions Agreement
be changed without any notice. When in doubt, special part numbers may be assigned to fix or estab­lish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product.
Errors and Omissions
Information presented by Omron Companies has been checked and is believed to be accurate; how­ever, no responsibility is assumed for clerical, typographical or proofreading errors or omissions.
NX-series Safety Control Unit User's Manual (Z930)
17
Page 20
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Additionally, there may be severe property damage.
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury, or property damage.
WARNING
Ca
ution

Safety Precautions

Safety Precautions

Definition of Precautionary Information

The following notation is used in this manual to provide precautions required to ensure safe usage of the NX-series Safety Control Unit. The safety precautions that are provided are extremely important to safety. Always read and heed the information provided in all safety precautions. The following notation is used.

Symbols

The circle and slash symbol indicates operations that you must not do. The specific operation is shown in the circle and explained in text. This example indicates prohibiting disassembly
The triangle symbol indicates precautions (including warnings). The specific operation is shown in the triangle and explained in text. This example indicates a precaution for electric shock.
The triangle symbol indicates precautions (including warnings). The specific operation is shown in the triangle and explained in text. This example indicates a general precaution.
The filled circle symbol indicates operations that you must do. The specific operation is shown in the circle and explained in text. This example shows a general precaution for something that you must do.
.
18
NX-series Safety Control Unit User's Manual (Z930)
Page 21

Warnings

WARNING
Serious injury may possibly occur due to loss of required safety functions. When building the system, observe the following warnings to ensure the integrity of the safety-related components.
Setting Up a Risk Assessment System
The process of selecting these products should include the development and execu­tion of a risk assessment system early in the design development stage to help identify potential dangers in your equipment and optimize safety product selection. Related International Standards:
• ISO 12100 General Principles for Design - Risk Assessment and Risk Reduction
Safety Precautions
Protective Measure
When developing a safety system for the equipment and devices that use safety prod­ucts, make every effort to understand and conform to the entire series of international and industry standards available, such as the examples given below Related International Standards:
• ISO 12100 General Principles for Design - Risk Assessment and Risk Reduction
• IEC 60204-1 Electrical Equipment of Machines - Part 1: General Requirements
• ISO 13849-1, -2 Safety-related Parts of Control Systems
• ISO 14119 Interlocking Devices Associated with Guards - Principles for Design and Selection
• IEC/TS 62046 Application of Protective Equipment to Detect the Presence of Per­sons
• IEC 62061 Functional Safety of Safety-related Electrical, Electronic and Programma­ble Electronic Control Systems
• IEC 61508 Functional Safety of Electrical/Electronic/Programmable Electronic Safe­ty-related Systems
.
Role of Safety Products
Safety products incorporate standardized safety functions and mechanisms, but the benefits of these functions and mechanisms are designed to attain their full potential only within properly designed safety-related systems. Make sure you fully understand all functions and mechanisms, and use that understanding to develop systems that will ensure optimal usage. Related International Standards:
• ISO 141 Selection
• ISO 13857 Safety Distances to Prevent Hazard Zones being Reached by Upper and Lower Limbs
19 Interlocking Devices Associated with Guards - Principles for Design and
NX-series Safety Control Unit User's Manual (Z930)
19
Page 22
Safety Precautions
Installing Safety Products
Qualified engineers must develop your safety-related system and install safety prod­ucts in devices and equipment. Prior to machine commissioning verify through testing that the safety products works as expected. Related International Standards:
• ISO 12100 General Principles for Design - Risk Assessment and Risk Reduction IEC 60204-1 Electrical Equipment of Machines - Part 1: General Requirements
• ISO 13849-1, -2 Safety-related Parts of Control Systems
• ISO 14119 Interlocking Devices Associated with Guards - Principles for Design and Selection
• IEC 62061 Functional Safety of Safety-related Electrical, Electronic and Programma­ble Electronic Control Systems
• IEC 61508 Functional Safety of Electrical/Electronic/Programmable Electronic Safe­ty-related Systems
Observing Laws and Regulations
Safety products must conform to pertinent laws, regulations, and standards. Make sure that they are installed and used in accordance with the laws, regulations, and stand­ards of the country where the devices and equipment incorporating these products are distributed.
Observing Usage Precautions
Carefully read the specifications and precautions as well as all items in the Instruction Manual for your safety product to learn appropriate usage procedures. Any deviation from instructions will lead to unexpected device or equipment failure not anticipated by the safety-related system.
Transferring Devices and Equipment
When transferring devices and equipment, be sure to retain one copy of the Instruction Manual and supply another copy with the device or equipment so the person receiving it will have no problems with operation and maintenance. Related International Standards:
• ISO 12100 General Principles for Design - Risk Assessment and Risk Reduction
IEC 60204-1 Electrical Equipment of Machines - Part 1: General Requirements
• ISO 13849-1, -2 Safety-related Parts of Control Systems
• IEC 62061 Functional Safety of Safety-related Electrical, Electronic and Programma­ble Electronic Control Systems
• IEC 61508 Functional Safety of Electrical/Electronic/Programmable Electronic Safe­ty-related Systems
20
Design
NX-series Safety Control Unit User's Manual (Z930)
Page 23
Safety Precautions
Confirm that the calculated reaction times meet the required specifications for all safety chains. Serious injury may possibly occur due to loss of required safety functions.
All safety devices and components that are connected to an NX-series Safety Control Unit must be selected and used to meet the required level of safety and the relevant safety category. Serious injury may possibly occur due to loss of required safety functions.
Do not use indicators on the NX-series Safety Control Units for safety operations. Serious injury may possibly occur due to loss of required safety functions.
Check during the import of the program that the CRC of the program is correct. Serious injury may possibly occur due to loss of required safety functions.
Check during the import of the user defined function that the CRC of the imported func­tion block is correct. Serious injury may possibly occur due to loss of required safety functions.
Do not use non-safety signals, including tag data links, explicit messages, and ex­posed variables, as safety signals. Serious injury may possibly occur due to loss of required safety functions.
If you select “Only Open” for the Open Type setting, make sure to verify that the origi­nator/target have correct configurations. Serious injury may possibly occur due to loss of required safety functions.
Before connecting an NX Series Safety Control Unit to the network, clear the previous settings. Serious injury may possibly occur due to loss of required safety functions.
Debugging
Before you perform safety validation of the safety programs, complete debugging of the safety programs. Otherwise, the Safety CPU Unit will start with safety programs that are not fully debug­ged and may cause serious personal injury.
Make sure that the area around the system is safe before you change the operating mode, change present values, or execute forced refreshing. The outputs may operate and may cause serious injury.
Make sure that the area around the system is safe before you start the system opera­tion while the online functional test is in progress. The outputs may operate and may cause serious injury.
Testing Operation
Before you start the system, perform user testing to make sure that all safety devices operate correctly Serious injury may possibly occur due to loss of required safety functions.
NX-series Safety Control Unit User's Manual (Z930)
. The safety signature is validated upon completion of the user testing.
21
Page 24
Safety Precautions
After you perform safety validation, check items for safety validation printed out to con­firm Safety Control Units are correctly configured.
Although the Simulator and Simple Automatic Test simulate the operation of the Safety CPU Unit, there are differences from the Safety CPU Unit in operation and timing. Al­ways confirm operation on the actual equipment before you operate the equipment. Accidents may occur if the controlled system performs unexpected operation.
Wiring
Wire the safety input and output lines so that they do not touch other lines. Serious injury may possibly occur due to loss of required safety functions.
Wire the Safety Control Unit properly so that 24-VDC lines do not touch output lines accidentally or unintentionally. Serious injury may possibly occur due to loss of required safety functions.
Wire the safety output lines and 24-VDC lines so that ground faults will not cause the loads to turn ON. Serious injury may possibly occur due to loss of required safety functions.
The wiring information that is displayed on the Sysmac Studio is for reference only and may dif forming suitable wiring. Serious injury may possibly occur due to loss of required safety functions.
fer from the actual wiring diagrams. Always confirm the actual wiring and per-
During Power Supply
Do not touch any of the terminals or terminal blocks while the power is being supplied. Doing so may result in electric shock.
Do not attempt to take any Unit apart. In particular, high-voltage parts are present in Units that supply power while power is supplied or immediately after power is turned OFF There are sharp parts inside the Unit that may cause injury.
. Touching any of these parts may result in electric shock.
Replacing Units
When replacing a Safety Control Unit, confirm that the model of the Unit is correct, confirm that the Unit and terminal block mounting positions are correct, configure the replacement Unit suitably, and confirm that the Unit operates correctly
.
Voltage and Current Inputs
Make sure that the voltages and currents that are input to the Units and slaves are within the specified ranges. Inputting voltages or currents that are outside of the specified ranges may cause acci­dents or fire.
22
NX-series Safety Control Unit User's Manual (Z930)
Page 25
Safety Precautions
Transferring
Always confirm safety at the destination before you transfer the unit configuration infor­mation, parameters, set values, or other data from tools such as the Sysmac Studio. The devices or machines may perform unexpected operation regardless of the operat­ing mode of the Controller.
Restoring Data
When you restore the Safety CPU Unit, confirm that the safety signature for the re­stored programs is correct. Serious injury may possibly occur due to loss of required safety functions.
NX-series Safety Control Unit User's Manual (Z930)
23
Page 26
Example: NX Unit (12 mm width)
N
G NG

Precautions for Safe Use

Precautions for Safe Use
Transporting
• Do not attempt to disassemble, repair, or modify any Units. Doing so may result in malfunction or fire.
• Do not drop any Unit or subject it to abnormal vibration or shock. Doing so may result in Unit mal­function or burning.
• When transporting any Unit, use the special packing box for it. Also, do not subject the Unit to ex­cessive vibration or shock during transportation.
Mounting
• Always turn OFF the power supply before mounting a Unit. If the power supply is not OFF, the Unit may malfunction or may be damaged.
• Mount terminal blocks and connectors only after checking the mounting location carefully. Be sure that the terminal blocks, expansion cables, and other items with locking devices are properly locked into place.
• Do not apply labels or tape to the Unit. When the Units are installed or removed, adhesive or scraps may adhere to the pins in the NX bus connector, which may result in malfunctions.
• Do not touch the pins in the NX bus connector on the Unit. Dirt may adhere to the pins in the NX bus connector, which may result in malfunctions.
• Do not write on the an NX Unit with ink within the restricted region that is shown in the following figure. Also do not get this area dirty. When the Unit is installed or removed, ink or dirt may adhere to the pins in the NX bus connector, which may result in malfunctions in the Controller. Refer to the user's manual of the CPU Unit or Communications Coupler Unit to be connected for details on the restricted region of the CPU Unit or Communications Coupler Unit.
24
NX-series Safety Control Unit User's Manual (Z930)
Page 27
Restricted region
(shaded portion)
Upper
Lower
NG OK
Precautions for Safe Use
• For the installation orientations in the following figure, support the cables, e.g., with a duct, so that the End Plate on the bottom is not subjected to the weight of the cables. The weight of the cables may cause the bottom End Plate to slide downward so that the Slave Terminal is no longer secured to the DIN T
rack, which may result in malfunctions.
Wiring
• Follow the instructions in this manual to correctly perform wiring.
• Double-check all switch settings to make sure that they are correct before turning ON the power
.
supply
• Use the correct wiring parts and tools when you wire the system. Otherwise, cables may be discon­nected to cause short-circuit or wire breakage.
• Do not pull on the cables or bend the cables beyond their natural limit. Do not place any heavy ob­jects on the cables or other wiring lines. Doing so may severe the cables.
• When wiring or installing the Units, do not allow metal fragments to enter the Units.
• Do not press the flat-blade screwdriver straight into the release hole on the screwless clamping ter­minal block. Doing so may damage the terminal block.
NX-series Safety Control Unit User's Manual (Z930)
25
Page 28
NG NG
Precautions for Safe Use
• When you insert a flat-blade screwdriver into a release hole on the screwless clamping terminal block, press the screwdriver down with a force of 30 N or less. Applying excessive force may dam­age the terminal block.
• Do not tilt or twist the flat-blade screwdriver while it is pressed into the release hole on the screwless clamping terminal block. Doing so may damage the terminal block.
Power Supply Design
• Use the I/O power supply capacity within the range that is given in the Unit specifications.
• Provide suitable power supply capacity according to the reference manuals.
Use the power supply voltage that is specified in the related manuals.
• Do not apply voltages that exceed the rated value to any Input Unit.
Debugging
• With forced refreshing, the values of variables are overwritten with specified values and then the safety programs are executed. If forced refreshing is used for variables that give the results of pro­gram processing, the variables will first take the specified values, but they will then be overwritten by the safety program.
• Depending on the dif
• After you clear the memory, the Controller operates in the same way as immediately after you create the system configuration with the Controller in the factory default condition.
• Verify that the safety communications with a remote node will be established in the debug mode of the Safety CPU Unit.
ference in the forced status, the control system may operate unexpectedly.
Turning ON the Power Supply or Restarting after Safety Validation
• Remember that if safety validation is successful, the next time the Safety CPU Unit is started, it will automatically start in RUN mode.
• When you download the parameters for the NJ/NX-series CPU Units, the Communications Coupler Unit and NX Units, the Safety CPU Unit automatically restarts.
Turning ON the Power Supply
• Double-check all wiring connections and switch settings to make sure that they are correct before turning ON the power supply. Use the correct wiring parts and tools when you wire the system.
26
NX-series Safety Control Unit User's Manual (Z930)
Page 29
Precautions for Safe Use
• Make sure that the voltages and currents that are input to the Units and slaves are within the speci­fied ranges. Inputting voltages or currents that are outside of the specified ranges may damage the Units or slaves or cause fire.
Actual Operation
• The relevant Units will maintain the safe states for I/O data with safety connections after an error is detected in safety process data communications. However, when the cause of the error is removed, safety process data communications will recover automatically If you need to prevent equipment from restarting when safety process data communications recover automatically, implement suitable restart conditions in the user program.
.
Turning OFF the Power Supply
• Do not disconnect the cable or turn OFF the power supply to the Controller or a Slave Terminal when downloading data or the user program from the Support Software.
• Always turn OFF the external power supply to the Units before attempting any of the following. a)
Mounting or removing an NX Unit. b) Assembling Units c) Setting DIP switches or rotary switches d) Connecting or wiring cables e) Attaching or removing terminal blocks or connectors The Power Supply Unit may continue to supply power to the Controller for a few seconds after the power supply turns OFF. The UNIT PWR and I/O PWR indicators are lit during this time. Confirm that the UNIT PWR and the I/O PWR indicators are not lit before you perform any of the above ac­tions.
General Communications
• Do not exceed the ranges that are given in the specifications for the communications distance and number of connected Units.
• Refer to the user safe use of communications with the connected CPU Unit or Communications Coupler Unit.
’s manual for the CPU Unit or Communications Coupler Unit for precautions for the
Standards
• The customer is responsible for attaining conformance of the entire system to standards.
Maintenance
• Test the functionality every six months to detect welded contactor contacts. To detect electrical and mechanical failures, use a combination of redundant semiconductor output contacts and redundant mechanical output devices.
NX-series Safety Control Unit User's Manual (Z930)
27
Page 30
Precautions for Safe Use
Unit Replacement
• After you replace the Safety Control Unit, set the program and all configuration settings that are nec­essary to resume operation. Make sure that the safety functions operate normally before you start actual operation.
• When you replace a Unit, start operation only after you transfer the settings and variables that are required for operation to the new Unit.
Disposal
• Dispose of the product according to local ordinances as they apply.
28
NX-series Safety Control Unit User's Manual (Z930)
Page 31

Precautions for Correct Use

Storage and Installation
• Follow the instructions in this manual to correctly perform installation and wiring.
• Do not operate or store the Units in the following locations. Doing so may result in burning, in opera­tion stopping, or in malfunction. a) Locations subject to direct sunlight b) Locations subject to temperatures or humidity outside the range specified in the specifications c) Locations subject to condensation as the result of severe changes in temperature d) Locations subject to corrosive or flammable gases e) Locations subject to dust (especially iron dust) or salts f) Locations subject to exposure to water, oil, or chemicals g) Locations subject to shock or vibration h) Locations subject to static electricity or other forms of noise
• Take appropriate and sufficient countermeasures when installing the Controller in the following loca­tions. a) Locations subject to strong, high-frequency noise b) Locations subject to static electricity or other forms of noise c) Locations subject to strong electromagnetic fields d) Locations subject to possible exposure to radioactivity e) Locations close to power lines
• Before touching a Unit, be sure to first touch a grounded metallic object in order to discharge any static build-up.
• Use the rated power supply voltage for the Units that supply power. Take appropriate measures to ensure that the specified power with the rated voltage and frequency is supplied in places where the power supply is unstable.
Precautions for Correct Use
Wiring
• Do not allow foreign matter to enter the openings in the Unit. Doing so may result in Unit burning, electric shock, or failure.
Actual Operation
• Make sure that you are connected to the correct Safety CPU Unit before you perform any online op­erations with the Safety CPU Unit.
• Before you transfer safety application data to the Safety CPU Unit, check the safety signature and make sure the data is the intended data.
• Always confirm the destination before you transfer configuration information and safety application data from the Sysmac Studio.
• You cannot monitor or perform certain online operations with the same Safety CPU Unit from more than one copy of the Sysmac Studio at the same time.
NX-series Safety Control Unit User's Manual (Z930)
29
Page 32
Precautions for Correct Use
Turning OFF the Power Supply
• Do not turn OFF the power supply while data is being transferred.
General Communications
• Refer to the user’s manual for the CPU Unit or Communications Coupler Unit for precautions for the correct use of communications with the connected CPU Unit or Communications Coupler Unit.
Debugging
• The task period affects the safety response performance. If the task period changes due to changes in the configuration or programs, recalculate the safety reaction times.
• If you change the I/O for a variable to publish to a NJ/NX-series CPU Unit, the device variable as­signments to the NJ/NX-series CPU Unit will be canceled. In this case, you need to assign the de­vice variables, and then transfer the settings and programs to the NJ/NX-series CPU Unit. After you transfer the settings and programs, check that the operation of the NJ/NX-series CPU Unit is cor­rect.
If you change the exposed variable in the EtherNet/IP Slave Terminal configuration, the I/O alloca­tions of the EtherNet/IP Couplers Unit will be changed. Check that the operation of the EtherNet/IP Coupler Unit is correct.
• For security purposes, we recommend that you set a password for the Safety CPU Unit and the project file. To avoid the leakage, keep the passwords under strict control. Especially, when you transmit password data through the Internet, implement a measure to secure the transmission such as by using the public key encryption.
• If you lose the password that is set to the Safety CPU Unit, you will no longer be able to make changes to the Safety CPU Unit. Take caution not to lose the password. If you want to reset the con­figured password, contact your OMRON representative.
• For safety data logging, make sure to use the settings file generated from the same project file as the logging target.
30
Periodic Inspections and Maintenance
• Do not disassemble, repair, or modify the Safety Control Unit. Doing so may lead to loss of safety functions.
Disposal
• Be careful not to injure yourself when dismantling the Safety Control Unit.
NX-series Safety Control Unit User's Manual (Z930)
Page 33

Regulations and Standards

The NX-series Safety Control Units are certified for the following standards.
Certification body Standards
EN ISO 13849-1: 2015
EN ISO 13849-2: 2012
IEC 61508 parts 1-7: 2010
TÜV Rheinland
UL NRAQ (UL61010-1, and UL 61010-2-201)
*1. The FSoE protocol was certified for applications in which OMRON FSoE devices are connected to each oth-
er. For compatibility with FSoE devices other than OMRON FSoE devices, the customer must validate FSoE communications.
*1
IEC/EN 62061:2005+A1: 2013+A2:2015
IEC/EN 61
IEC/EN 60204-1: 2016
NRAG (ANSI/ISA 12.12.01) NRAQ7 (CSA C22.2 No. 61010-1, and CSA C22.2 No. 61010-2-201) FSPC (IEC 61508 and EN ISO 13849)
131-2: 2007
Regulations and Standards
IEC 61326-3-1: 2017
IEC 61131-6: 2012
The NX-series Safety Control Units allow you to build a safety control system that meets the following standards.
• Requirements for SIL 3 (Safety Integrity Level 3) in IEC 61508, EN 62061, (Functional Safety of Electrical/Electronic/Programmable Electronic Safety-related Systems)
• Requirements for PLe (Performance Level e) and for safety category 4 in EN ISO13849-1
The NX-series Safety Control Units are also registered for RCM, EAC, and KC compliance.

Conformance to EU Directives

Applicable Directives
• EMC Directives
• Low Voltage Directive
Concepts
EMC Directives
l
OMRON devices that comply with EU Directives also conform to the related EMC standards so that they can be more easily built into other devices or the overall machine. The actual products have been checked for conformity to EMC standards.*1 Whether the products conform to the standards in the system used by the customer, however, must be checked by the customer. EMC-related performance of the OMRON devices that comply with EU Directives will vary depending on the configuration, wiring, and other conditions of the equip­ment or control panel on which the OMRON devices are installed. The customer must, therefore, perform the final check to confirm that devices and the overall machine conform to EMC standards.
NX-series Safety Control Unit User's Manual (Z930)
31
Page 34
Regulations and Standards
*1. Applicable EMC (Electromagnetic Compatibility) standards are as follows: EMS (Electromagnetic Suscept-
ibility): EN 61131-2 EMI (Electromagnetic Interference): EN 61 tions).
Machinery Directive
l
The Machinery Directive requires ensuring the required safety for safety components used for ma­chinery safety. The applicable directives are EN ISO 13849-1:2008 and EN 62061 SIL CL3.
Conformance to EU Directives
l
131-2 (Radiated emission: 10-m regula-
The NX-series Units comply with EU Directives. T NX-series Units are used complies with EU Directives, the following precautions must be observed.
• The NX-series Units must be installed within a metallic control cabinet.
• You must meet the following conditions for the DC power supplies that are connected as the Unit power supplies and I/O power supplies for the NX-series Units. a) Use reinforced insulation or double insulation. b) Ensure an output hold time of 20 ms min. c) Use an SELV power supply that meets the requirements of IEC/EN 60950-1 and EN 50178.
Do not allow the power supply cable length to exceed 3 m. We recommend that you use the OMRON S8VK-S-series Power Supplies. EMC standard com­pliance was confirmed for the recommended Power Supplies.
• NX-series Units that comply with EU Directives also conform to the Common Emission Standard. Radiated emission characteristics (10-m regulations) may vary depending on the configuration of the control panel used, other devices connected to the control panel, wiring, and other condi­tions. You must therefore confirm that the overall machine or equipment in which the NX-series Units are used complies with EU Directives.
• This is a Class A product (for industrial environments). In a residential environment, it may cause radio interference. If radio interference occurs, the user may be required to take appropriate measures.
o ensure that the machine or device in which the

Conformance to EN ISO 13849-1 and EN 62061

EN ISO 13849-1 and EN 62061 require functional safety management to avoid systematic failure dur­ing the software development. This is required in all phases of the life cycle of software programming and software design (e.g., basic software design, safety circuit system design, and software upgrades) in safety control systems to be developed using safety controllers. Therefore, functional safety management is required for design and development of software for facili­ties and equipment that use the function blocks provided in the Safety Controller The customer must implement measures to ensure compliance with these standards.
Y
ou can download the reliability data for safety of machinery that is required to verify the safety per­formance of your equipment from the following URL: http://www.ia.omron.com/support/sistemalibrary/ index.html.
32
.
NX-series Safety Control Unit User's Manual (Z930)
Page 35

Conformance to UL and CSA Standards

The NX-series Safety Control Units comply with the following UL and CSA standards. The application conditions for standard compliance are defined. Refer to the Instruction Sheet that is provided with each Unit before application.

Conformance to Shipbuilding Standards

Some NX-series products comply with shipbuilding standards. If you use an NX-series product that complies with shipbuilding standards and the machinery or system in which you use the NX-series product must also comply with the standards, consult with your OMRON representative. Application conditions are defined according to the installation location. Application may not be possible for some installation locations.
Usage Conditions for NK and LR Shipbuilding Standards
Regulations and Standards
Usage Conditions for Locations Other Than the Bridge or Decks
l
• A Safety Control Unit must be installed within a control panel.
• Gaps in the door to the control panel must be completely filled or covered with gaskets or other material.
Usage Conditions for the Bridge (Certified only by Nippon Kaiji Kyokai
l
(Class NK))
A Safety Control Unit must be installed within a control panel.
• Gaps in the door to the control panel must be completely filled or covered with gaskets or other material.
• The following noise filter must be connected to the power supply line.
Noise Filter
Name Manufacturer Model
Noise filter Cosel Co., Ltd. TAH-06-683

Conformance to KC Certification

Observe the following precaution if you use NX-series Units in Korea.
Class A Device (Broadcasting Communications Device for Office Use) This device obtained EMC registration for office use (Class A), and it is intended to be used in places other than homes. Sellers and/or users need to take note of this.
NX-series Safety Control Unit User's Manual (Z930)
33
Page 36
Regulations and Standards
Usage Conditions for KC Certification
Take the same measures as those described in Conformance to EU Directives on page 31. In addi­tion, attach a clamp core to the port side of the EtherNet/IP cable. The recommended clamp core is given below
Recommended Clamp Core
Manufacturer Product Model Turns of cable
NEC TOKIN Clamp core ESD-SR-250 1 turn
.
34
NX-series Safety Control Unit User's Manual (Z930)
Page 37

Unit Versions

Notched
area
Unit
specifications
LOT No.
Lot number and unit version Unit model number
Unit versionLot number
This section describes the notation that is used for unit versions, the confirmation method for unit ver­sions, and the relationship between unit versions and Sysmac Studio versions.

Unit Versions

A “unit version” refers to a revision number of the respective NX-series Units. A “unit version” has been introduced to manage the Units in the NX Series according to differences in functionality accom­panying Unit upgrades.
Notation of Unit Versions on Products
The unit version is given with the Unit specifications on the side of the Unit or in the notched area.
Unit Versions
NX-series Safety Control Unit User's Manual (Z930)
35
Page 38
Unit Versions
The following information is provided in the Unit specifications on the Unit.
Unit model number Gives the model of the Unit. Unit version Gives the unit version of the Unit. Lot number Gives the lot number of the Unit.
The following information is provided in the notched area on the Unit.
Lot number and unit ver­sion
Name Function
,
DDMYY£: Lot number “M” gives the month (1 to 9: January to September, X: October, Y: November, Z: December)
Name Function
Gives the lot number and unit version of the Unit.
DDMYY£: Lot number,
“M” gives the month (1 to 9: January to September, X: October, Y: November, Z: December)
£: Used by OMRON.
£: Used by OMRON.
1£: Unit version
The decimal portion of the unit version is omitted. (It is provided in the Unit specifications.)
Confirming Unit Versions with the Support Software
If your NX Unit is connected to a CPU Unit, refer to the user’s manual of the connected CPU Unit for the confirmation method for the unit version of the NX Unit. If your NX Unit is connected to a Communications Coupler Unit, refer to the user’s manual of the con­nected Communications Coupler Unit for the confirmation method for the unit version of the Communi­cations Coupler Unit and NX Unit.

Unit Versions of Units and Sysmac Studio Versions

The functions that are supported depend on the unit version of the Unit. The version of Sysmac Studio that supports the functions that were added for an upgrade is also required to use those functions. Refer to A-17 Version Information on page A - 105 for the relationship between the unit versions of the Units and the Sysmac Studio versions, and for the functions that are supported by each unit version.
36
NX-series Safety Control Unit User's Manual (Z930)
Page 39

Related Manuals

The followings are the manuals related. Use these manuals for reference.
Manual name Cat. No. Model numbers Application Description
NX-series Safety Control Unit User's Manual
NX-series Safety Control Unit Instructions Reference Man­ual
NX-series Data Reference Manual
Sysmac Studio Version 1 Operation Manual
NJ/NX-series
roubleshooting Manual
T
NX-series
EtherCAT® Coupler Unit
’s Manual
User
NX-series
EtherNet/IP Coupler Unit User’
NX-series System Units User’
NX-series NX102 CPU Unit Hardware User
s Manual
s Manual
’s Manual
Z930
Z931
W525
W504 SYSMAC
W503
W519
W536
W523
W593
NX-SL££££ NX-SI££££ NX-SO££££
NX-SL££££
NX-££££££
-SE2£££
NX701-££££ NX102-££££ NX1P2-££££ NJ501-££££ NJ301-££££ NJ101-££££
NX-ECC£££
NX-EIC£££
NX-PD1£££ NX-PF0£££ NX-PC0£££ NX-TB£££X
NX102-££££
Learning how to use NX-series Safety Control Units.
Learning about the specifications of in­structions for the Safety CPU Unit.
Referencing lists of the data that is re­quired to configure systems with NX-ser­ies Units.
Learning about the operating procedures and functions of the Sysmac Studio.
Learning about the errors that may be detected in an NJ/NX-series Con-
.
troller
Learning how to use the NX-series Ether­CAT Coupler Unit and EtherCAT Slave Terminals.
Learning how to use an NX-series Ether­Net/IP Coupler Unit and EtherNet/IP Slave Terminals.
Learning how to use NX-series System Units
Learning the basic specifications of the NX102 CPU Units, including introductory information, design­ing, installation, and maintenance. Mainly hardware in­formation is provided.
Related Manuals
Describes the hardware, setup methods, and functions of the NX-series Safety Con­trol Units.
Describes the instructions for the Safety CPU Unit.
Lists of the power consumptions, weights, and other NX Unit data that is required to configure systems with NX-series Units are provided.
Describes the operating procedures of the Sysmac Studio.
Concepts on managing errors that may be detected in an NJ/NX-series Controller and information on individual errors are descri­bed.
The following items are described: the overall system and configuration methods of an EtherCAT Slave Terminal (which con­sists of an NX-series EtherCAT Coupler Unit and NX Units), and information on hardware, setup, and functions to set up, control, and monitor NX Units through EtherCAT.
The following items are described: the overall system and configuration methods of an EtherNet/IP Slave Terminal (which consists of an NX-series EtherNet/IP Cou­pler Unit and NX Units), and information on hardware, setup, and functions to set up, control, and monitor NX Units.
The hardware and functions of the NX-ser­ies System Units are described.
An introduction to the entire NX102 system is provided along with the following infor­mation on the CPU Unit.
Features and system configuration
Introduction
Part names and functions
General specifications
Installation and wiring
Maintenance and Inspection
NX-series Safety Control Unit User's Manual (Z930)
37
Page 40
Related Manuals
Manual name Cat. No. Model numbers Application Description
NJ/NX-series CPU Unit
s Manual
Communi-
Port
Built-in EtherNet/IP™ User
’s Manual
NJ/NX-series CPU Unit Software User
NJ/NX-series Instructions Reference Manual
AC Servomotors/Servo Drives G5 Series with
Built-in EtherCAT® cations User's Manual
Multi-function Compact Inver­ter MX2-series V1
s Manual
User AC Servomotors/Servo
Drives 1S-series with
Built-in EtherCAT® Communi­cations User's Manual
W506
W501
W502
I576
I577
I585
I586
NX701-££££ NX102-££££ NX1P2-££££ NJ501-££££ NJ301-££££ NJ101-££££
NX701-££££ NX102-££££ NX1P2-££££ NJ501-££££ NJ301-££££ NJ101-££££
NX701-££££ NX102-££££ NX1P2-££££ NJ501-££££ NJ301-££££ NJ101-££££
R88M-K£ R88D-KN£-ECT
R88L-EC-£ R88D-KN£-ECT-L
3G3MX2-A££££­V1
R88M-1£ R88D-1SN£
-ECT
Using the built-in EtherNet/IP port on an NJ/NX-series CPU Unit.
Learning how to pro­gram and set up an NJ/NX-series CPU Unit. Mainly software infor­mation is provided.
Learning detailed specifications on the basic instructions of an NJ/NX-series CPU Unit.
Learning how to use the AC Servomotors/ Servo Drives with built-in EtherCAT Communications.
Learning how to use the MX2-series Multi­function Compact In­verter.
Learning how to use the Servomotors/ Servo Drives with built-in EtherCAT Communications.
Information on the built-in EtherNet/IP port is provided. Information is provided on the basic setup, tag data links, and other features.
The following information is provided on a Controller built with an NJ/NX-series CPU Unit.
CPU Unit operation
CPU Unit features
Initial settings
Programming based on IEC 61131-3
language specifications
The instructions in the instruction set (IEC
131-3 specifications) are described.
61
Describes the hardware, setup methods and functions of the AC Servomotors/ Servo Drives with built-in EtherCAT Com­munications. The linear motor type model and the model dedicated for position controls are availa­ble in G5-series.
Describes the hardware, setup methods, and functions of the MX2-series Multi-func­tion Compact Inverter.
Describes the hardware, setup methods and functions of the Servomotors/Servo Drives with built-in EtherCAT Communica­tions.
38
NX-series Safety Control Unit User's Manual (Z930)
Page 41

Terminology

Terminology
Term Description
standard The generic term for devices, functions, and data that are used for general control purposes
as opposed to those that are used for safety measures.
safety function A function that is executed by the safety control system to achieve a safe state for a machine
hazard.
safe state The status of a device or piece of equipment when the risk of danger to humans has been
reduced to an acceptable level.
safety signal A signal that is used for safety controls.
In this safety control system, the data type of a variable determines whether a signal is relat­ed to the safety controls. Broadly speaking, there are two data types: safety data types and
standard data types. standard signal A signal or data that is used for general control purposes. Safety data type The data type for a safety signal. Standard data type The data type for a standard signal. safety reaction time The time required for the system to enter a safe state in a worst-case scenario after the oc-
currence of a safety-related input (press of an emergency stop pushbutton switch, interrup-
tion of a light curtain, opening of a safety door
The reaction time of the system includes the reaction times of sensors and actuators, just
like the reaction time for a Controller or network. safety control A type of control that uses devices, functions, and data that are designed with special safety
measures. standard control A type of control that use devices, functions, and data that are designed for general control
purposes. This term is used to differentiate from a safety control safety process data communications standard process data communications A type of I/O data communications that is used for standard control purposes. Safety I/O connection A type of connections that is used for safety process data communications. CIP Safety connection Safety I/O connection that is used to transmit safety process data by the communication pro-
CIP Safety originator connection A CIP Safety connection when an own node is a CIP Safety originator. CIP Safety target connection A CIP Safety connection when an own node is a CIP Safety target. CIP Safety originator A role in CIP Safety communications. A CIP Safety originator manages a CIP Safety connec-
CIP Safety target A role in CIP Safety communications. A CIP Safety target receives a request to open a CIP
single-cast connection A safety process data communications method in CIP Safety
multi-cast connection A safety process data communications method in CIP Safety
FSoE master connection Master safety I/O connection that is used to transmit safety process data by the communica-
safety master connection The generic term for the CIP Safety originator connection and the FSoE master connection. exposing global variables to the NJ/NX-
series CPU Unit Safety Control Unit The generic term for a Unit that is used in safety controls. Safety CPU Unit A CPU Unit that is used for safety controls. This is a type of NX Unit. Safety I/O Unit An I/O Unit that is used for safety controls. This is a type of NX Unit.
A type of I/O data communications that is used for safety control purposes.
tocol called CIP Safety
are available depending on the roles of communications.
tion for a CIP Safety target. CIP Safety originator exists in a connection unit, and not in a
device unit.
Safety connection from a CIP Safety originator
and not in a device unit.
CIP Safety target communicate one-to-one in this connection.
You can apply this setting for both of input data and output data.
input data of the CIP Safety target in multi-cast to multiple CIP Safety originators in this con-
nection.
This is a connection type you can set only for input data of a CIP Safety target. You cannot
apply this setting for output data.
tion protocol called FSoE.
Exposing specified global variables to the NJ/NX-series CPU Unit to allow the exchange of
standard signals between the NJ/NX-series CPU Unit and the Safety CPU Unit.
. CIP Safety originator connection and CIP Safety target connection
, etc.) or device failure.
. CIP Safety target exists in a connection unit,
. A CIP Safety originator and a
. A CIP Safety target sends the
NX-series Safety Control Unit User's Manual (Z930)
39
Page 42
Terminology
Term Description
safety input device An input device that is designed with special safety measures for use in safety controls.
The generic term for safety input devices, such as emergency stop pushbutton switches and safety switches.
safety output device An output device that is designed with special safety measures for use in safety controls.
The generic term for safety output devices, such as safety relays.
EtherNet/IP Slave Terminal An EtherNet/IP Slave Unit Terminal is a building-block slave that is created by mounting a
group of NX Units.
Safety program User programming for safety controls in the Safety CPU Unit.
This term is used to dif CPU Unit. Safety programs are programmed in the FBD language.
FBD language The abbreviation for the function block diagram programming language. This is a graphical
language used to program algorithms with connecting lines that represent the flow of inputs and data, and rectangular boxes that represent functions or function blocks. Unlike the ladder diagram language, the FBD language does not have bus bars, and the connecting lines represent the flow of inputs and data rather than the power flow. Algorithms are executed in order from top to bottom in units that are called networks. A net­work consists of configuration elements that use connecting lines to connect inputs to out­puts. The FBD language does not have an END instruction. Execution for the task period ends when the last network is executed.
ou use the FBD language to write safety programs for the Safety CPU Unit.
Y
user program All of the programs that are created by the user. It refers to the programs for standard con-
trols of the NJ/NX-series CPU Units and the safety program of the Safety CPU Units.
operating mode The status of the Safety CPU Unit, when it is in normal operation, that the user changes to
run or check the operation of the Safety CPU Unit. There are the three modes: PROGRAM mode, DEBUG mode, and RUN mode. You can use DEBUG mode only when the Sysmac Studio is online with the Safety CPU Unit.
safety validation The process of appending confirmation information to the safety application data if safety val-
idation testing demonstrates that the safety controls meet the required specifications of a safety system. You execute the safety validation from the Sysmac Studio when the Safety CPU Unit is in DEBUG mode. The validated safety programs are automatically transferred to the non-vola­tile memory of the Safety CPU Unit.
DEBUG mode The mode that is used to debug unvalidated safety programs. DEBUG mode is only available
when the Sysmac Studio is online with the Safety CPU Unit. Use this mode to check that the safety programs and external devices operate correctly. Af­ter you confirm that the system meets the required specifications, perform the safety valida­tion. This will enable you to change to RUN mode. When you change from PROGRAM mode to DEBUG mode, the unvalidated safety programs are automatically transferred to the main memory of the Safety CPU Unit.
DEBUG mode (RUN) A status that indicates that an unvalidated safety program is in execution in DEBUG mode.
You can control BOOL variables, use forced refreshing, and change present values.
DEBUG mode (ST
PROGRAM mode A mode indicates that execution of the safety program is stopped. You cannot control BOOL
RUN mode A mode that indicates that execution of the validated safety programs is in progress. Unlike
before safety validation A status that indicates that safety validation has not been performed on the safety applica-
after safety validation A status indicates that safety validation has been performed on the safety application data
OPPED) A status that indicates that an unvalidated safety program is stopped in DEBUG mode. You
can control BOOL variables, use forced refreshing, and change present values.
variables, use forced refreshing, or change present values.
DEBUG mode (RUN), the validated safety programs in the non-volatile memory of the Safety CPU Unit are executed. Y change present values.
tion data from the Sysmac Studio because it has not yet been determined whether the safety controls meet the required specifications of the safety system.
from the Sysmac Studio because it has been determined that the safety controls meet the required specifications of the safety system.
ferentiate safety programs from user programs in the NJ/NX-series
ou cannot control BOOL variables, use forced refreshing, or
40
NX-series Safety Control Unit User's Manual (Z930)
Page 43
Terminology
Term Description
CPU Rack A Rack to which a CPU Unit or Communication Control Unit is mounted. For NX-series CPU
Units to which NX Units can be connected, a CPU Rack has a CPU Unit with NX Units and
an End Cover mounted to it. For NX-series Communication Control Units, a CPU Rack has a
Communication Control Unit with NX Units and an End Cover mounted to it. CPU Rack settings Consists of the following items.
Configuration information
Unit operation settings
Unit application data
Slave Terminal settings Consists of the following items.
Configuration information
Unit operation settings
Unit application data
configuration information It consists of the following data:
Unit configuration information
I/O allocation information
I/O allocation information The set of information that specifies the I/O data to be processed by I/O refreshing.
On the Sysmac Studio, this is shown as configuration information and includes the Unit con-
figuration information. Unit configuration information The set of information that specifies the configuration of the NX Units that are connected to
the NX bus master.
On the Sysmac Studio, this is shown as configuration information and includes the I/O allo-
cation information. safety application data The data that contains the settings that are used to operate the NX-series Safety Control
Units.
It consists of the safety programs, safety task, and variables. You use the Sysmac Studio to
create this data, and then transfer and execute it on the Safety CPU Unit.
On the Sysmac Studio, this data is shown as the slave parameters.
The location where the safety application data is stored on the Safety CPU Unit depends on
whether the safety programs have been validated. (Unvalidated safety programs are stored
in the main memory safety input function A function that evaluates whether the signals that are input on a safety input terminal are
normal or abnormal.
Specific safety evaluation functions include test pulse evaluation and dual channel evalua-
tion.
When the evaluation result shows an abnormality, the safety input data is made inactive
(OFF). safety output function A function that evaluates whether the values of safety output data and the output signals on
safety output terminals are normal or abnormal.
Specific safety evaluation functions include test pulse evaluation and dual channel evalua-
tion.
When the evaluation result shows an abnormality, the output signal on the safety output ter-
minal is turned OFF dual channel evaluation This function uses a pair of safety input or safety output terminals as redundant terminals
that are checked for consistency to evaluate the status of the safety input or safety output. single channel The input or output is used as a single point. dual channels Two inputs or outputs are used as a pair of points for redundancy. test pulse evaluation This function outputs a test pulse that is used to evaluate a safety input or safety output for
failures or wiring errors with the connected external device. change tracking A pin is used to manage whether the safety application data has been changed after the fi-
nalized data is created.
, while validated safety programs are stored in the non-volatile memory.)
.
NX-series Safety Control Unit User's Manual (Z930)
41
Page 44
Cat. No.
Z930-E1-13
Revision code

Revision History

Revision History
A manual revision code appears as a suffix to the catalog number on the front and back covers of the manual.
Revision
code
01 June 2013 Original production 02 September
03 December 2013
04 August 2014
05 January 2015 06 April 2015
07 July 2015
08 April 2016
09 July 2016
Date Revised content
Added NX-SL3500.
2013
Added information on offline debugging.
Added information on 10-A Terminal Blocks.
Corrected mistakes.
Added procedures to upload data.
Corrected mistakes.
Made changes accompanying the upgrade to NX-SL££££ unit version 1.1.
Made changes accompanying the upgrade to NX-SIH400 unit version 1.1.
Made revisions accompanying connection to EtherNet/IP Coupler Units.
Corrected mistakes.
Made revisions accompanying the upgrade to Sysmac Studio version 1.12.
Made revisions accompanying the upgrade to Sysmac Studio version 1.13.
Corrected mistakes.
4-1-2 Calculating the Safety Reaction Time
Corrected numeric values for OMRON Special Safety Input Devices that are used when calculating safety sensor/switch response time.
4-1-2 Calculating the Safety Reaction T
Corrected the calculation method for safety input refresh time and safety out­put refresh time for safety I/O refresh time.
4-1-2 Calculating the Safety Reaction Time
Added precaution for conformance to ISO 13856-1:2013.
Made revisions accompanying the upgrade to Sysmac Studio version 1.15.
3-3-1 Safety Input Function
Changed connection wiring diagrams.
A-3 Application Examples
Changed wiring examples.
Added precautions for correct use.
Corrected mistakes.
Made revisions accompanying the upgrade to Sysmac Studio version 1.16.
Corrected mistakes.
ime
42
NX-series Safety Control Unit User's Manual (Z930)
Page 45
Revision History
Revision
code
10 October 2016
Date Revised content
Made revisions accompanying the upgrade to Sysmac Studio version 1.17.
6-9-2 Exporting/Importing Data for the Entire NX Unit
7-5-2 Registering POUs
Added program import/export functions.
8-5 Checking External Device Wiring
8-7-2 Data Protection
Added the program data protection function.
Corrected mistakes.
11 April 2018
Made revisions accompanying connection to NX-series CPU Units.
Made revisions associated with the addition of UM Safety Mats.
Corrected mistakes.
12 July 2018
Added NX-SL5700 and NX-SL5500
Corrected mistakes.
13 August 2018 Added PFH values.
NX-series Safety Control Unit User's Manual (Z930)
43
Page 46
Revision History
44
NX-series Safety Control Unit User's Manual (Z930)
Page 47
Overview
This section introduces and describes the features, system configuration, and applica­tion procedure of the NX-series Safety Control Unit
1-1 Introduction and Features........................................................................... 1 - 2
1-2 System Configuration and Configuration Devices ...................................1 - 8
1-3 Support Software .......................................................................................1 - 12
1-4 Commissioning Procedures ..................................................................... 1 - 15
1
s.
1-1-1 Overview of Safety Control Unit.................................................................... 1 - 2
1-1-2 Features of Safety Control Unit .................................................................... 1 - 5
1-2-1 Safety Control System Configuration on NX bus of CPU Unit or
EtherCAT Network......................................................................................... 1 - 8
1-2-2 Safety Control System Configuration on EtherNet/IP Network................... 1 - 10
1-2-3 Standalone Safety Control System Configuration ...................................... 1 - 10
1-2-4 Types of Safety Control Unit........................................................................1 - 11
1-3-1 Applicable Support Software ...................................................................... 1 - 12
1-3-2 Connection Method and Procedures for EtherCAT Coupler Units.............. 1 - 12
1-3-3 Connection Method and Procedures for EtherNet/IP Coupler Units........... 1 - 14
1-4-1 Overall Procedure....................................................................................... 1 - 15
1-4-2 Detailed Procedures ................................................................................... 1 - 16
1
NX-series Safety Control Unit User's Manual (Z930)
1 - 1
Page 48
1 Overview
1-1
1-1-1

Introduction and Features

Overview of Safety Control Unit

The NX-series Safety Control Units are part of the lineup of Sysmac devices. They are used to exe­cute safety controls. Safety Control Units are classified as NX Units and they are used connected to an NX-seriess, EtherCAT Coupler Unit or EtherNet/IP Coupler Unit. You use the integrated development environment that is provided by the Sysmac Studio Automation Software to build the safety control system, and perform all settings, programming, and debugging of the Safety Control Unit.
Safety Control System on CPU Rack or EtherCAT Network
The NX-series Safety Control Units can be connected to the following units.
• NX-series CPU Unit
NX-series EtherCAT Coupler Unit When using both the CPU Unit and EtherCAT Coupler Unit, you can integrate the installation, wiring, and setting methods of the NX Unit, which will enable design costs to be reduced. These Units achieve safety controls on an CPU Rack or EtherCAT network when they are used in a sequence and motion control system that is based on the NJ/NX-series Machine Automation Control­ler.
*1. Only one Safety CPU Unit can be used in this system. *2. Refer to the user's manual of the CPU Unit to be used for details on whether the Safety Control Unit can be
connected to the CPU Unit to be used.
*2
*1
The Safety Control Unit connected to a CPU Unit performs I/O communications with the CPU Unit. The Safety Control Unit with the EtherCAT master through the EtherCAT Coupler Unit. Both methods support the FSoE (Safe­ty over EtherCAT) protocol through each communication and perform safety I/O communications be­tween the FSoE master and slaves through the CPU Unit that has a built-in EtherCAT master. This allows you to use safety process data communications and standard process data communications on the same EtherCAT network through the NX bus of the CPU Unit that has a built-in EtherCAT master.
Additional Information
• NX102 CPU Units support connection of NX-SL££££ Units, NX-SI££££ Units, and NX­SO££££ Units.
• NX-series Units, and NX-SO££££ Units. It does not support connection to NX-SL5£££ Units.
connected to an EtherCAT Coupler Unit performs remote I/O communications
EtherCAT Coupler Units support connection of NX-SL3£££ Units, NX-SI££££
1 - 2
NX-series Safety Control Unit User's Manual (Z930)
Page 49
NJ/NX-series
Sysmac Studio
EtherCAT slaves, such as servos, vision systems, and I/O
Et
herCAT master
EtherCAT slaves
Setting, programming, and debugging the Safety Control Units
Safety Control Units
EtherCAT Coupler Unit
EtherCAT Coupler Unit
EtherCAT
1 Overview
1-1 Introduction and Features
1
1-1-1 Overview of Safety Control Unit
When you set up the Safety System configuration on the Sysmac Studio, you automatically achieve safety process data communications (Safety over EtherCAT) on any EtherCA
T network that was in-
stalled for standard process data communications.
Safety Control System on EtherNet/IP Network
You can build a safety control system which performs CIP Safety on EtherNet/IP communications with other controllers on the same EtherNet/IP network when you connect an NX-series
with an NX-series CPU Unit*1.
*1. Refer to A-17 Version Information on page A - 105 for the model numbers and unit versions of the applicable
NX-series CPU Units.
In addition, you can build a safety control system which performs CIP Safety on EtherNet/IP communi­cations in a system that does not use an SL5£££ Unit with an NX-series NX-CSG320 Communication Control Unit. For details on systems that use NX-series Communication Control Units, refer to the NX-series Safety Control Unit /
NX-series CPU Unit when you connect an NX-series NX-
Communication Control Unit User's Manual (Cat. No. Z395).
NX-SL5£££ Unit
NX-series Safety Control Unit User's Manual (Z930)
1 - 3
Page 50
NX-series CPU Unit
*1
Safety CPU Unit NX-SL5£££
EtherCAT
EtherCAT slaves, such as servos, vision systems, and I/O, NX-series Safety I/O Units
EtherCAT slaves, such as servos, vision systems, and I/O, NX-series Safety I/O Units
Standard Controller
Sysmac Studio
EtherNet/IP
NX-series CPU Unit
*1
Safety CPU Unit NX-SL5£££
EtherCAT
Safety control
between
automation
system
Safety control within
automation system
Safety control within automation system
1 Overview
*1. Refer to A-17 Version Information on page
A - 105 for the model numbers and unit versions of the applicable
NX-series CPU Units.
This system enables the safety controls between respective automation systems upon building up each automation system that has the safety control built around EtherCAT which feature high speed and high precision.
Additional Information
CIP Safety on EtherNet/IP communications are only available for the combination where an NX­SL5£££ Unit is connected to an NX-series
CPU Unit or to a Communication Control Unit. It
cannot be used with NX-SL3£££ Units.
Standalone Safety Control System
The NX-SL3300 Unit is used connected to an EtherNet/IP Coupler Unit to achieve safety controls in a Slave Terminal.
The Safety Control Unit EtherNet/IP Coupler Unit.
performs remote I/O communications with a standard controller through an
1 - 4
NX-series Safety Control Unit User's Manual (Z930)
Page 51
Sysmac Studio
Setting, programming, an
d debugging the Safety Control Units
Safety Control Unit
EtherNet/IP
E
t
herNet/IP Coupler Unit
Slave Terminal
1 Overview
Additional Information
• Standalone safety control system does not support CIP Safety on EtherNet/IP communica­tions.
• The EtherNet/IP Coupler Units support connection of NX-SL3300 Units, NX-SI££££ Units and NX-SO££££ Units. It does not support connection to NX-SL5£££ Units and NX­SL3500 Units.
1-1 Introduction and Features
1

1-1-2 Features of Safety Control Unit

1-1-2
Features of Safety Control Unit
Achieving Safety Control System on CPU Rack or EtherCAT Net­work
Integrating Safety Controls in a Sequence and Motion Control System
l
You can use NX-series Safety Control Units to integrate a safety control system into a sequence and motion control system. The safety I/O communications support the FSoE protocol and can be built in as a subsystem on the NX Bus of CPU Unit or EtherCA cables or interface devices are required for safety communications.
Easy Creation of an Interface with the Standard Controls
l
ou can exchange data between the safety controls that are based on the Safety CPU Unit and the
Y standard controls that are based on the NJ/NX-series CPU Unit. This allows you to maintain the independent nature of the previously separate safety controls and standard controls while easily interfacing monitoring and commands between them.
T network. Therefore, no special safety control communications
NX-series Safety Control Unit User's Manual (Z930)
Achieving Safety Control System on EtherNet/IP Network
CIP Safety on EtherNet/IP Is Supported
l
You can combine an NX-series NX-SL5£££ Unit with an NX-series ty-based communications between devices that support CIP Safety on EtherNet/IP or other Safety CPU Units.
CPU Unit to enable CIP Safe-
1 - 5
Page 52
1 Overview
Achieving Standalone Safety Control System on EtherNet/IP Slave T
l
l
Excellent Connectability with OMRON Safety I/O Devices
You can directly connect OMRON’s wide lineup of Safety I/O Devices to Safety I/O Units without using any special units.
erminal
Constructing a Small Safety Control System
You can configure a small standalone safety control system on the EtherNet/IP Slave Terminal by using an NX-series Safety Control Unit
Easy Creation of an Interface with the Standard I/O Data
You can easily exchange data between Safety CPU Unit and standard I/O Units.
.
Integrating Setting and Debugging Operations for Safety Controls into the Sysmac Studio
Setting and debugging operations for safety controls are integrated into the Sysmac Studio Automa­tion Software. The shared concepts, such as IEC 61131-3, consistent operating procedures, one-project manage­ment, integrated debugging, and integrated troubleshooting, reduce the software workload.
Support for the IEC 61131-3 Programming Environment
Program Languages Based on the IEC 61131-3 International Standard
l
Programming is possible with the FBD language, which is part of the programming language speci­fications of IEC 61131-3. And the safety function blocks that are defined in PLCopen® TC5 Safety are also supported.
Programming with V
l
Programming with variables eliminates the need to specify memory addresses so that you can cre­ate user programs that are not dependent on any hardware considerations, such as the model of the Controller or the system configuration. This allows you to reuse user programming, even for dif­ferent Controller models or system configurations.
ariables
1 - 6
Complete Advanced Validation
NX-series Safety Control Unit User's Manual (Z930)
Page 53
1 Overview
Checking Safety Programs and Safety Parameters
l
You can verify beforehand whether your safety programs (user program for safety controls that runs on the Safety CPU Unit) and safety parameters (parameters that are used for safety controls) meet the validity and safety aspects that are outlined below.
Validity and safety issues related to function block diagram programs, such as missing or incor­rect connection for function blocks
• Safety issues, such as the incorrect connection of a standard input to a safety input parameter of a function block
• Validity of the safety task period
These checks help to prevent design regression and help to ensure the reliability of the safety de­signs.
Debugging function
l
You can connect the Sysmac Studio to perform various types of debugging, including monitoring, changing present values, and forced refreshing.
1-1 Introduction and Features
1
1-1-2 Features of Safety Control Unit
NX-series Safety Control Unit User's Manual (Z930)
1 - 7
Page 54
Safety CPU Unit
NX-series CPU Unit
Coupler Unit
Coupler Unit
Safety control system
NX-series NX Bus/EtherCAT Integrated System
The Safety CPU Unit performs safety process data communications with the Safety I/O Units.
EtherCAT master /NX bus master
Slave Terminal Slave Terminal
Coupler Unit: EtherCAT Coupler Unit Safety Input: Safety Input Unit Safety Output: Safety Output Unit
(These abbreviations apply to all subsequent figures in this manual.)
Safety Input
Safety Input
Safety Output
Safety Output
EtherCAT
1 Overview
1-2
1-2-1
System Configuration and Configura­tion Devices

Safety Control System Configuration on NX bus of CPU Unit or EtherCAT Network

In this configuration, the safety control system operates on the NX bus of the NX-series on the EtherCAT network. The safety control system consists of the NX-series CPU Unit with the NX bus master function, CPU Unit with the EtherCA slave function.
T master function, and the NX-series EtherCAT Coupler Unit with the EtherCAT
CPU Unit and
1 - 8
NX-series Safety Control Unit User's Manual (Z930)
Page 55
Slave Terminal
The Safety CPU Unit performs safety process data communica­tions with the Safety I/O Units.
Slave Terminal
Safety
CPU Unit
NJ/NX-series CPU Unit
Coupler Unit
Safety control system
NJ/NX-series EtherCAT Communications System
EtherCAT ma st er
• Coupler Unit: EtherCAT Coupler Unit
• Safety Input: Safety Input Unit
• Safety Output: Safety Output Unit (These abbreviations apply to all figures in this manual.)
Safety Output
Safety Input
Safety Output
Safety Input
Coupler Unit
Coupler Unit
EtherCAT
EtherCAT ma st er
Safety CPU Unit
NJ/NX-series CPU Unit
Coupler Unit
Safety Output
Safety Input
Safety Output
Safety Input
Coupler Unit
Coupler Unit
Digital Output
Digital Input
EtherCAT
1 Overview
1-2 System Configuration and
Configuration Devices
1
1-2-1 Safety Control System Configuration on NX bus of CPU Unit or EtherCAT Network
The Safety CPU Unit serves the FSoE master function to control the Safety I/O Units with the FSoE
slave function served and the FSoE slave.*1 As shown in the above figure, the Safety CPU Unit can be used to control not only the Safety I/O Units Slave Terminal, but also it can control Safety I/O Units that are mounted to other EtherCAT Slave Ter­minals through the EtherCAT network. You can use only one Safety CPU Unit on each EtherCAT net­work.
*1. The connectivity of FSoE communications between the OMRON NX-series Safety Control Unit is confirmed
using the OMRON 1S-series Servo Driver.
Y
ou can also mount just a Safety CPU Unit to an EtherCAT Coupler Unit without mounting Safety I/O
Units, as shown in the following figure. Standard I/O Units*1 can also be mounted in the same Slave Terminal, but they cannot be controlled by the Safety CPU Unit.
*1. This refers to NX Units used for standard control, such as Digital Input Units and Digital Output Units.
that are mounted to the same CPU Rack or EtherCAT
Refer to the NX-series EtherCAT network configurations.
NX-series Safety Control Unit User's Manual (Z930)
EtherCAT Coupler Unit User’s Manual (Cat. No. W519) for information on
1 - 9
Page 56
Safety CPU Unit
Et
herNet/IP network
Safety CPU Unit
The device that supports CIP Safety on EtherNet/IP such as Safety I/O Terminal and Robot Controller.
NX-series CPU Unit
NX-series CPU Unit
Safety control system
The Safety CPU Unit performs safety process data communications between the another Safety CPU Units and the device that supports CIP Safety on EtherNet/IP by CIP Safety on EtherNet/IP.
Safety Control System in EtherNet/IP Network
1 Overview
l
Applicable NJ/NX-series CPU Units and NX-series EtherCAT Coupler Unit
Refer to A-17 Version Information on page A - 105 for the model numbers and unit versions of the NJ/NX-series CPU Units and the
Precautions for Correct Use
If you use an NX-series CPU Unit, you cannot set both the priority-5 periodic task and another task for an EtherCAT Coupler Unit that contains a Safety Control Unit Refer to the NX-series EtherCAT Coupler Unit User’s Manual (Cat. No. W519) for details on task settings.
NX-series EtherCAT Coupler Units that can be used together.
.
1-2-2

Safety Control System Configuration on EtherNet/IP Network

The safety control system operates in the EtherNet/IP network.
Applicable NX-series CPU Units
l
Refer to A-17 Version Information on page A - 105 for the model numbers and unit versions of the applicable
NX-series CPU Units.
1-2-3

Standalone Safety Control System Configuration

The safety control system operates in the Slave Terminals of the EtherNet/IP Coupler Units.
1 - 10
NX-series Safety Control Unit User's Manual (Z930)
Page 57
Safety
CPU
Unit
Coupler Unit
Coupler Unit
Safety Control System
Safety Control System in EtherNet/IP Slave Terminals
Slave Terminal Slave Terminal
Safety Output
Safety Input
Safety Output
Safety Input
Safety
CPU
Unit
Coupler Unit
The Safety CPU Unit performs safety process data communications with the Safety I/O Units in the Slave Terminal.
Standard CPU Unit
1 Overview
You can control Safety I/O Units that are mounted to the same Slave Terminal as the Safety CPU Unit You cannot use the EtherNet/IP network to control the operation of Safety I/O Units that are mounted to other Slave T
erminals. You can use only one Safety CPU Unit on each Slave Terminal.
1-2 System Configuration and
Configuration Devices
1

1-2-4 Types of Safety Control Unit

Applicable NX-series EtherNet/IP Coupler Units
l
Refer to A-17 Version Information on page A - 105 for the model numbers and unit versions of the applicable NX-series EtherNet/IP Coupler Units.
1-2-4
Types of Safety Control Unit
This section provides the Classification of NX-series Safety Control Unit.
Unit classification Introduction
Safety CPU Unit This Unit has safety control functions.
Safety I/O Units These Units have safety input functions or safety output functions.
Safety Input Unit Safety Output Unit These Units have Safety Output functions.
Refer to Section 2 Specifications on page
It operates as an NX Unit. It also operates as an FSoE master. It operates as a CIP-Safety-on-EtherNet/IP device.
They operate as NX Units. These Units operate as FSoE slaves.
These Units have safety input functions.
2 - 1 for details on individual Units.
NX-series Safety Control Unit User's Manual (Z930)
1 - 11
Page 58
Ethernet
USB
USB
Sysmac Studio
Sysmac Studio
Sysmac Studio
Safety CPU Unit
NJ/NX-series CPU Unit
Coupler Unit
Safety Output
Safety Input
Coupler Unit
Safety Output
Safety Input
EtherNet/IP
EtherCAT
1 Overview
1-3
1-3-1
1-3-2

Support Software

You use the Support Software to set up the safety control system for the Safety Control Unit and to perform programming and debugging.

Applicable Support Software

You use the Support Software to set up the safety control system for the Safety Control Unit, and to perform programming and debugging. Refer to A-17 Version Information on page A - 105 for informa­tion on combinations of the applicable Support Software and versions.
Refer to the Sysmac Studio Version 1 Operation Manual (Cat. No. W504) for the system requirements of the Sysmac Studio.

Connection Method and Procedures for EtherCAT Coupler Units

In general, there are the following two ways to connect the Sysmac Studio.
• USB Connection or Ethernet Connection to the NJ/NX-series CPU Unit The USB connection and Ethernet connection are functionally identical. This is the most common connection method.
• USB Connection to the NX-series EtherCAT Coupler Unit This method is functionally limited when compared with a connection to the NJ/NX-series CPU Unit. This connection method is used mainly for debugging.
1 - 12
Refer to the Sysmac Studio Version 1 Operation Manual (Cat. No. W504) for the connection proce­dure.
You use the Sysmac Studio to connect to the USB port or the built-in EtherNet/IP port of the NJ/NX­series CPU Unit. This connection allows you to download safety programs to the Safety CPU Unit Safety I/O Units on the EtherCAT network.
USB Connection or Ethernet Connection to the NJ/NX-series CPU Unit
and to monitor the
NX-series Safety Control Unit User's Manual (Z930)
Page 59
USB
USB or EtherNet/IP
NJ/NX-series EtherCAT Communications System
Sysmac Studio
Safety CPU Unit
NJ/NX-series CPU Unit
Coupler Unit
Safety Output
Safety Input
Coupler Unit
Safety Output
Safety Input
Accessible
Accessible
Safety control system
EtherCAT
Safety control system
USB
The Safety I/O Units mounted under the other EtherCAT Coupler Unit cannot be accessed.
Coupler Unit
Sysmac Studio
NJ/NX-series EtherCAT Communications System
Safety CPU Unit
NJ/NX-series CPU Unit
Coupler Unit
Safety Output
Safety Input
Safety Output
Safety Input
Only the Safety I/O Units mounted under the Safety CPU Unit are accessible.
EtherCAT
1 Overview
1-3 Support Software
1
1-3-2 Connection Method and Procedures for EtherCAT Coupler Units
USB connection to the EtherCAT Coupler Unit
You can connect the Sysmac Studio to the USB port on the EtherCAT Coupler Unit. This connection allows you to download, upload, and monitor the safety programs for only the Safety CPU Unit and Safety I/O Units that are under the EtherCAT Coupler Unit that the Sysmac Studio is online with. The other devices cannot be accessed.
NX-series Safety Control Unit User's Manual (Z930)
Precautions for Correct Use
There are functional restrictions when you connect to the EtherCAT Coupler Unit via the USB port in comparison with connecting to the NJ/NX-series CPU Unit. We therefore recommend that you connect to the NJ/NX-series CPU Unit.
1 - 13
Page 60
Safety Control System in EtherNet/IP Slave Terminals
USB
Coupler Unit
Safety
CPU
Unit
Safety Control System
Sysmac Studio
Only the Safety I/O Units mounted under the Safety CPU Unit are accessible.
The Safety I/O Units mounted under the other Communications Coupler Unit cannot be accessed.
Safety Output
Safety Input
Coupler Unit
Safety
CPU
Unit
Safety Output
Safety Input
EtherNet/IP
1 Overview
Functional Differences on the Sysmac Studio Based on the Con­nection Point
The functions that you can use on the Sysmac Studio depend on what the Sysmac Studio is connect­ed to. Refer to the NX-series EtherCAT Coupler Unit User
’s Manual (Cat. No. W519) for details.
1-3-3

Connection Method and Procedures for EtherNet/IP Coupler Units

Connect the Sysmac Studio to the USB port on the EtherNet/IP Coupler Unit. This connection allows you to download, upload, and monitor the safety programs for only the CPU Unit and online with. The other devices cannot be accessed.
Safety I/O Units that are under the EtherNet/IP Coupler Unit that the Sysmac Studio is
Safety
1 - 14
NX-series Safety Control Unit User's Manual (Z930)
Page 61
Standard Control
Safety Control
Step 1. System Design
Step 1-1 Determining Safety Measures by Performing Risk Assessment
Step 2. Software Design
Step 2. Hardware Design
Step 2-1 Designing I/O and Processing
Step 2-2 Designing Safety Programs
Step 3 Calculating and Verifying Safety Response Performance
Step 3-1 Calculating Safety Reaction Time and Safety Distance
Step 3-2 Verifying Fulfillment of Required Specifications
Step 4. Software Settings and Programming
Step 4-1 Creating the Safety Control System Configuration
Step 4-3 Assigning Safety I/O Terminals to the Connected Devices
Step 4-4 Assigning Device Variables to I/O Ports
Step 4-5 Programming
Step 5. Installation and Wiring
Step 6. Checking Operation
Step 6-1 Changing to DEBUG Mode After Transferring the Slave Terminal Configuration Information
Step 6-2 Checking Operation Using the Controller
Step 6-3 Performing Safety Validation Testing
Step 6-5 Validating Safety from the Sysmac Studio (Transferring the Program to the Non-volatile Memory)
Step 7. Operation, Maintenance, and Inspection
Software Design
Designing I/O and P rocessing
Designin g Tasks
Designin g User Program
Software Settings and Programming
Slave an d Unit Con figuratio ns
Controller Setup and Assignment of Device Variables to I/O Ports
Programm ing
Offline Debugging
Transfer ring the P roject (Includi ng Slave T erminal C onfigurati on Information)
Online D ebugging
Step 1-3 Designing the Interface between Standard Controls and Safety Controls
Step 1-2 Selecting Safety Devices
Checking Operation
Step 7-3 Inspection and Replacement
Step 7-1 Operation
Step 7-2 Troubleshooting Errors If They Occur
Step 2-1 Determining Wiring for Communications, Power Supply, and External I/O Devices
Step 4-2 Setting Up and Checking the Safety Process Data Communications
Step 4-6 Offline Debugging
Step 5-1 Installation
Step 5-3 Wiring the I/O
Step 5-4 Connecting the Computer That Runs the Sysmac Studio
Step 5-2 Connecting the Ethernet Cables
Step 6-4 Designing Device Security
1 Overview

1-4 Commissioning Procedures

1-4
1-4-1
Use the following procedure to build a safety system. The procedure is divided into steps for standard control and safety control.
Commissioning Procedures
Overall Procedure
1

1-4-1 Overall Procedure

NX-series Safety Control Unit User's Manual (Z930)
1 - 15
Page 62
1 Overview
1-4-2

Detailed Procedures

As described in the previous section, the standard controls and safety controls are linked with one an­other throughout the setup procedures. This section describes the detailed procedures for the safety controls.
Refer to NJ/NX-series CPU Unit Software User for using NJ/NX-series CPU Units for standard control.
Step 1. System Design
Step Description Reference
Step 1-1 Determining Safety Measures by Per­forming Risk Assessment
Step 1-2 Selecting Safety Devices
Identify potential danger factors and perform
risk assessment.
Study and decide on measures to reduce
risks.
Select the safety devices for inputs, logic, and outputs of the safety controls.
s Manual (Cat. No. W501)for the detailed procedures
---
1-2 System Configuration and Configuration Devices on page
1 - 8
ction 2 Specifications on
Se
page 2 - 1
2-1-2 Part Names and Func­tions on page 2 - 8
Step 1-3 Designing the In­terface between Standard Controls and Safety Con­trols
Step 2. Software Design
Step Description Reference
Step 2-1 Designing I/O and Processing
Design the interface between the standard con­trols and safety controls. This is done by exposing the global variables to the NJ/NX-series CPU Unit.
Design the configuration of the safety I/O devi­ces and Safety I/O Units.
Safety I/O devices
Program contents
5-7 Exposing Variables to Standard Controllers on page
5 - 30
2-1-2 Part Names and Func­tions on page 2 - 8
1 - 16
NX-series Safety Control Unit User's Manual (Z930)
Page 63
Step Description Reference
Step 2-2 Designing Safety Programs
Design the POUs (Program Organization Units).
Programs
Function blocks
Design of Variables:
Design the data types of the variables (partic-
ularly the design of safety data types and standard data types).
Define the variables that you will use in more
than one POU and variables that you will use in only specific POUs.
Define the variable names for the device vari-
ables that you use to access Safety I/O Units.
Define the attributes of variables, such as the
Name attribute.
Design the variables to expose to the user
program for the standard controls.
Design the interface with the safety controls
of the user program for the standard controls.
1 Overview
ection 6 Programming on
S
page
6 - 1
1-4 Commissioning Procedures
1
1-4-2 Detailed Procedures
Step 2. Hardware Design
Step Description Reference
Step 2-1 Determining Wir­ing for Communications, Power Supply, and Exter­nal I/O Devices
Determine the wiring for the communications network, power supply, and safety I/O devices.
Step 3. Calculating and Verifying Safety Response Performance
Step Description Reference
Step 3-1 Calculating Safe­ty Reaction Time and Safe­ty Distance
Step 3-2 Verifying Fulfill­ment of Required Specifi­cations
Calculate the safety reaction times and use them to find the safety distances.
Check to see if requirements are met. If require­ments are not met, reconsider the designs again starting with the system design.
Step 4. Software Settings and Programming
2-1-2 Part Names and Func­tions on page 2 - 8
Manuals for specific Communi­cations Coupler Units Manuals for the specific NX Units
ection 8 Calculating Safety
S Reaction Times on page
8 - 1
Section 8 Calculating Safety Reaction Times on page
8 - 1
Step Description Reference
Step 4-1 Creating the Safety Control System Configuration
Step 4-2 Setting Up and Checking the Safety Proc­ess Data Communications
NX-series Safety Control Unit User's Manual (Z930)
On the Sysmac Studio, configure the NX bus master
Check the settings for the safety process data communications and make any necessary changes.
, Safety CPU Unit and Safety I/O Units
5-3 Controller Configuration
.
and Setup of the Safety Control Units on page 5 - 5
5-4 Setting Up the Safety Proc­ess Data Communications on
page 5 - 12
1 - 17
Page 64
1 Overview
Step Description Reference
Step 4-3 Assigning Safety I/O Terminals to the Con­nected Devices
Step 4-4 Assigning Device Variables to I/O Ports
Step 4-5 Programming Variable Registration:
On the parameter setting tab page for the ty I/O Units, select the safety I/O devices that are connected to the safety I/O terminals.
Register the device variables in the global varia­ble table. (You can use either user-defined or automatical­ly assigned variable names.)
Register the variables that are used by more
than one POU in the global variable table with the Sysmac Studio.
Register the variables that are used in only a
specific program in the local variable table for that program.
Register the variables that are used in only a
specific function block in the local variable ta­ble for that function block.
Safe-
5-5 Safety I/O Functions on page 5 - 23
5-6 Registering Device V bles on page 5 - 26
6-5 Programming Operations
on page 6 - 26
aria-
Writing Algorithms for POUs: W
rite the algorithms for the POUs (programs
and function blocks) using the FBD language.
Step 4-6 Offline Debugging The Simulator is used to debug the program. 6-8 Offline Debugging on page
6 - 79
Step 5 Installation and Wiring
Step Description Reference
Step 5-1 Installation
Step 5-2 Connecting the Ethernet Cables
Step 5-3 Wiring the I/O
Connect the Units to each other.
Mount the connected Units on a DIN T
Connect the NJ/NX-series CPU Units or other standard controllers to the Communications Coupler Units.
rack.
Wire the Safety I/O Units.
Section 3 Installation and Wir­ing on page 3 -
Manuals for specific Communi­cations Coupler Units
ection 3 Installation and Wir-
S ing on page 3 - 1
1
1 - 18
NX-series Safety Control Unit User's Manual (Z930)
Page 65
1 Overview
Step Description Reference
Step 5-4 Connecting the Computer That Runs the Sysmac Studio
Use one of the following connections.
Connect a USB cable to the NJ/NX-series
CPU Unit
*1
Connect an Ethernet cable to the built-in
EtherNet/IP port on the NJ/NX-series CPU Unit.*1
Connect a USB cable to the Communications
Coupler Unit
*1. You can use this connection method only if you use an NJ/NX-series CPU Unit and EtherCAT Coupler Unit.
Step 6. Checking Operation
Step Description Reference
Step 6-1 Changing to DE­BUG Mode After Transfer­ring the Slave T Configuration Information
erminal
Place the Sysmac Studio online with the NJ/NX­series CPU Unit*1 or the Communications Cou-
pler Unit and then transfer the Slave Terminal configuration information. Then, change the Safety CPU Unit from the Safety CPU Unit Setup and Programming View. This transfers the safety application data to the Safety CPU Unit and enables debugging.
1-3 Support Software on page 1 -
12
Refer to the
Version 1 Operation Manual (Cat. No. W504)
Manuals for specific Communi­cations Coupler Units
7-2 Transferring the Configura­tion Information on page
7 - 7
7-3 Operating Modes of the Safety CPU Unit on page
7 - 11
7-4 Changing to DEBUG Mode
on page 7 - 17
Sysmac Studio
1-4 Commissioning Procedures
1
1-4-2 Detailed Procedures
Step 6-2 Checking Opera­tion Using the Controller
Step 6-3 Performing Safety Validation T
Step 6-4 Designing Device Security
Step 6-5 Validating Safety from the Sysmac Studio
*1. You can use this connection method only if you use an NJ/NX-series CPU Unit and EtherCAT Coupler Unit.
esting
Check all wiring and the operation of the pro­gram to check that the Safety Control Unit oper­ates as intended.
Test all safety functions to see if they operate according to designs.
Set the safety passwords. 7-9 Security Settings on page
After the safety validation testing has been passed, execute the Safety Validation operation from the Sysmac Studio. This transfers the safety application data to the non-volatile memory in the enables operation.
Safety CPU Unit and
7-6 Functions for Checking Op-
on page
eration
7-6 Functions for Checking Op­eration on page 7 - 27
7 - 51
7-10 Performing Safety Valida­tion and Operation on page
7 - 56
7 - 27
Step 7. Operation, Maintenance, and Inspection
Step Description Reference
Step 7-1 Operation Restart the Safety CPU Unit.
If the Safety CPU Unit gram, the Safety CPU Unit will automatically start in RUN mode.
NX-series Safety Control Unit User's Manual (Z930)
has a validated user pro-
7-10 Performing Safety Valida­tion and Operation on page
7 - 56
1 - 19
Page 66
1 Overview
Step Description Reference
Step 7-2 Troubleshooting Errors If They Occur
Step 7-3 Inspection and Replacement
If an error occurs, use the troubleshooting func­tion of the Sysmac Studio to check the error and determine the cause. Then, remove the error.
Perform periodic maintenance. If you find any defects or problems during the in­spection, replace the affected devices.
ection 12 Troubleshooting on
S
page 12 - 1
S
ection 13 Inspection and
Maintenance on page 13 - 1
1 - 20
NX-series Safety Control Unit User's Manual (Z930)
Page 67
2
2
Specifications
This section provides the specifications of the Safety CPU Unit and the Safety I/O Units.
2-1 Safety CPU Unit
2-1-1 Models and Specifications ............................................................................ 2 - 2
2-1-2 Part Names and Functions ........................................................................... 2 - 8
2-1-3 Indicators .................................................................................................... 2 - 10
2-2 Safety Input Unit......................................................................................... 2 - 16
2-2-1 Models and Specifications .......................................................................... 2 - 16
2-2-2 Part Names and Functions ......................................................................... 2 - 22
2-2-3 Indicators .................................................................................................... 2 - 24
2-3 Safety Output Unit...................................................................................... 2 - 28
2-3-1 Models and Specifications .......................................................................... 2 - 28
2-3-2 Part Names and Functions ......................................................................... 2 - 35
2-3-3 Indicators .................................................................................................... 2 - 38
2-4 PFH ..............................................................................................................2 - 41
............................................................................................ 2 - 2
NX-series Safety Control Unit User's Manual (Z930)
2 - 1
Page 68
2 Specifications
2-1
2-1-1

Safety CPU Unit

This section describes the models and specifications of the Safety CPU Units as well as the names and functions of the parts.

Models and Specifications

The Safety CPU Unit specifications are described below.
Models
The following table specifies the list of Safety CPU Unit models.
Maximum
Model
NX-SL3300 256 points 512 KB
NX-SL3500 1,024 points 2,048 KB
NX-SL5500 1,024 points 2,048 KB
NX-SL5700 2,032 points 4,096 KB
*1. Only FSoE master connections are supported. *2. CIP Safety originator connections, CIP Safety target connections, and FSoE master connections are sup-
ported.
number of
safety I/O
points
Program ca-
pacity
Number of
safety I/O con-
nections
*1
32
*1
128
*2
128
*2
254
I/O refreshing method
Free-Run refreshing
Free-Run refreshing
Free-Run refreshing
Free-Run refreshing
General Specifications
This section provides the general specifications of the Safety CPU Unit.
Item Specification
Enclosure Mounted in a panel (open) Grounding method Ground to 100 Ω or less
2 - 2
NX-series Safety Control Unit User's Manual (Z930)
Page 69
Item Specification
Operating environment Ambient operating tem-
perature
Ambient operating hu­midity
Atmosphere Must be free from corrosive gases.
Ambient storage temper­ature
Altitude 2,000 m max. Pollution degree Pollution degree 2 or less: Conforms to JIS B 3502
Noise immunity Conforms to IEC 61 Insulation class CLASS III (SELV) Overvoltage category Category II: Conforms to JIS B 3502 and IEC 61131-2 EMC immunity level Zone B Vibration resistance Conforms to IEC 60068-2-6
Shock resistance Conforms to IEC 60068-2-27
Installation method DIN T
0 to 55°C
10% to 95% (with no condensation or icing)
−25 to 70°C (with no condensation or icing)
and IEC 61
5 to 8.4 Hz with amplitude of 3.5 mm
8.4 to 150 Hz, acceleration of 9.8 m/s 100 min. in each X, Y 10 min. each = 100 min. total)
147 m/s2, 3 times in each X, Y, and Z directions
2 Specifications
131-2
131-2, 2 kV (power supply line)
2
, and Z directions (10 sweeps of
rack (IEC 60715 TH35-7.5/TH35-15)
2-1 Safety CPU Unit
2
2-1-1 Models and Specifications
Individual Specifications
This section provides the individual specifications of the Safety CPU Unit.
Datasheet Items for Safety CPU Unit
l
The following table gives the meaning of the datasheet items for the Safety CPU Unit.
Item Description
Maximum number of safety I/O points
Program capacity This is the capacity of the safety programs in the Unit.
Number of safety I/O connec-
*1
tions
Number of CIP Safety origi-
nator connections
Number of CIP Safety target
connections
Number of originators that can be connected with a mul­ti-cast connection
Number of FSoE master con­nections
I/O refreshing method The I/O refreshing methods that are used by the Unit.
*2
*2
This is the number of safety I/O points that Safety CPU Unit can control.
This is the maximum number of Safety I/O connections that can be set to this Unit. The value is the total number of CIP Safety originator connections, CIP Safety target connections, and FSoE master connections.
This is the maximum number of CIP Safety originator connections that can be set to this Unit.
This is the maximum number of CIP Safety target connections that can be set to this Unit.
When this unit is a CIP Safety target, it is the number of CIP Safety origina­tors that can be connected with a multi-cast connection by a single CIP Safe­ty target connection.
It is the maximum number of FSoE master connections that can be config­ured to this unit.
NX-series Safety Control Unit User's Manual (Z930)
2 - 3
Page 70
2 Specifications
External connection termi­nals
Indicators The type of indicators on the Unit and the layout of those indicators. Hardware switch settings It is the type and layout of hardware switches for the Unit. Dimensions (mm) These are the external dimensions of the Unit. The dimensions are given in
I/O power supply method The method for supplying I/O power for the Unit. The supply method is deter-
Current capacity of I/O power supply terminal
NX Unit power consumption The power consumption of the NX Unit power supply of the Unit.
Current consumption from I/O power supply
Weight The weight of the Unit.
Installation orientation and restrictions
*1. Refer to 5-4-3 Calculating the Number of Connections on page 5 - 20 for how to calculate the number of
connections.
*2. The number of CIP Safety connections that can be actually set depends on the maximum number of routa-
ble CIP Safety connections of the NX-series CPU Unit. For NX102 CPU Units, the maximum number of routable CIP Safety connections is 16.
Item Description
The type of terminal block and connector that is used for connecting the Unit. This specification includes the number of terminals for a screwless clamping terminal block.
the form W × H × D. The dimensions are given in
mined for each Unit. The power can be supplied either from the NX bus or from an external source.
The current capacity of the I/O power supply terminals (IOV/IOG) of the Unit. Do not exceed this value when supplying the I/O power to the connected ex­ternal devices.
The current consumption from I/O power supply of the Unit. This value does not include the load current of any external connection loads or the current consumption of any connected external devices.
This is the installation orientation of the Unit. Any restrictions to specifications that result from the installation orientation are also given.
"millimeters".
NX-SL3300
l
Item Specification
Maximum number of safety I/O points 256 points Program capacity 512 KB Number of safety I/O connections 32 Number of CIP Safety originator connections 0 Number of CIP Safety target connections 0
Number of originators that can be connected with a multi-cast connection
Number of FSoE master connections 32 I/O refreshing method Free-Run refreshing External connection terminals None Indicators [FS] LED, [VALID] LED, [DEBUG] LED, [TS] LED, [RUN]
Hardware switch settings None Dimensions (mm) 30 × 100 × 71 mm (W × H × D) I/O power supply method Not supplied. Current capacity of I/O power supply terminals No I/O power supply terminals
0
LED
2 - 4
NX-series Safety Control Unit User's Manual (Z930)
Page 71
2 Specifications
Item Specification
NX Unit power consumption
Current consumption from I/O power supply No consumption Weight 75 g max. Installation orientation and restrictions Installation orientation:
*1. The cable length for the Units that supply power to the corresponding Unit must be up to 20 m. *2. Only NX102 CPU Units can be connected. NX1P2 CPU Units cannot be connected.
NX-SL3500
l
*1
Connected to a CPU Unit
1.25 W max.
Connected to a Communications Coupler Unit
0.90 W max.
Connected to a CPU Unit
Possible in the upright installation orientation.
*2
Connected to a Communications Coupler Unit
Six possible orientations.
Restriction: None.
2-1 Safety CPU Unit
2
2-1-1 Models and Specifications
Item Specification
Maximum number of safety I/O points 1,024 points Program capacity 2,048 KB Number of safety I/O connections 128 Number of CIP Safety originator connections 0 Number of CIP Safety target connections 0
Number of originators that can be connected with a multi-cast connection
Number of FSoE master connections 128 I/O refreshing method Free-Run refreshing External connection terminals None Indicators [FS] LED, [VALID] LED, [DEBUG] LED, [TS] LED, [RUN]
Hardware switch settings None Dimensions (mm) 30 × 100 × 71 mm (W × H × D) I/O power supply method Not supplied. Current capacity of I/O power supply terminals No I/O power supply terminals
NX Unit power consumption
*1
0
LED
Connected to a CPU Unit
1.25 W max.
Connected to a Communications Coupler Unit
0.90 W max.
Current consumption from I/O power supply No consumption Weight 75 g max.
NX-series Safety Control Unit User's Manual (Z930)
2 - 5
Page 72
Seven-segment indicator
[TS] LED, [NS] LED, [FS] LED
[P ERR] LED, [RUN] LED,
[VALID] LED, [DEBUG] LED
2 Specifications
Installation orientation and restrictions Installation orientation:
*1. The cable length for the Units that supply power to the corresponding Unit must be up to 20 m. *2. Only NX102 CPU Units can be connected. NX1P2 CPU Units cannot be connected.
NX-SL5500
l
Maximum number of safety I/O points 1,024 points Program capacity 2,048 KB Number of safety I/O connections 128
Number of CIP Safety originator con­nections
Number of CIP Safety target connec­tions
Number of originators that can be connected with a multi-cast connec­tion
Number of FSoE master connections 128 I/O refreshing method Free-Run refreshing External connection terminals None Indicators [TS] indicator, [NS] indicator, [FS] indicator, [P ERR] indicator, [RUN]
Item Specification
Connected to a CPU Unit
Possible in the upright installation orientation.
*2
Connected to a Communications Coupler Unit
Six possible orientations.
Restriction: None.
Item Specification
128
4
8
, [V
indicator cator
ALID] indicator, [DEBUG] indicator, seven-segment indi-
2 - 6
Hardware switch settings [SERVICE] switch, [SETTING] switch
Dimensions (mm) 30 × 100 × 71 mm (W × H × D) I/O power supply method Not supplied.
NX-series Safety Control Unit User's Manual (Z930)
Page 73
Seven-segment indicator
[TS] indicator, [NS] indicator, [FS] indicator
[P ERR] indicator, [RUN] indicator,
[VALID] indicator, [DEBUG] indicator
2 Specifications
Item Specification
Current capacity of I/O power supply terminal
NX Unit power consumption
Current consumption from I/O power supply
Weight 130 g max.
Installation orientation and restric-
*2
tions
*1. The cable length for the Units that supply power to the corresponding Unit must be up to 20 m. *2. Only NX102 CPU Units and Communication Control Units can be connected. NX1P2 CPU Units or Commu-
nications Coupler Units cannot be connected.
NX-SL5700
l
Item Specification
Maximum number of safety I/O points
Program capacity 4,096 KB
Number of safety I/O connec­tions
Number of CIP Safety origi­nator connections
Number of CIP Safety target connections
Number of originators that can be connected with a mul­ti-cast connection
Number of FSoE master con­nections
I/O refreshing method Free-Run refreshing
External connection termi­nals
Indicators [TS] indicator, [NS] indicator, [FS] indicator, [P ERR] indicator, [RUN] indica-
*1
2,032 points
254
254
4
8
254
None
tor
No I/O power supply terminals
3.35 W max.
No consumption
Installation orientation: Upright installation Restriction: None.
ALID] indicator, [DEBUG] indicator, seven-segment indicator
, [V
2-1 Safety CPU Unit
2
2-1-1 Models and Specifications
NX-series Safety Control Unit User's Manual (Z930)
2 - 7
Page 74
(D)
(D)
(E)
(C)
(G)
(F)
(E)
(A)
(C)
(C)
(B)
(E)
(B)
(B)
(E)
2 Specifications
Hardware switch settings [SERVICE] switch, [SETTING] switch
Dimensions (mm) 30 × 100 × 71 (W × H × D) I/O power supply method Not supplied.
Current capacity of I/O power supply terminals
NX Unit power consump-
*1
tion
Current consumption from I/O power supply
Weight 130 g max.
Installation orientation and
restrictions
*1. The cable length for the Units that supply power to the corresponding Unit must be up to 20 m. *2. Only NX102 CPU Units and Communication Control Units can be connected. NX1P2 CPU Units or Commu-
nications Coupler Units cannot be connected.
Item Specification
No I/O power supply terminals
3.35 W
No consumption
Installation orientation: Upright installation
*2
Restriction: None.
2-1-2

Part Names and Functions

This section describes the names and functions of the Safety CPU Unit components.
NX-SL3300 or NX-SL3500
l
2 - 8
NX-series Safety Control Unit User's Manual (Z930)
Page 75
(D)
(D)
(E)
(C)
(I)
(F)
(E)
(A)
(G)
(H)
(C)
(C)
(B)
(E)
(B)
(B)
(G)
(H)
(E)
2 Specifications
Letter Name Function
(A) Marker attachment loca-
tions
(B) Protrusions for removing
the Unit
(C) DIN Track mounting
hook (D) NX bus connector This is the NX-series bus connector. (E) Unit hookup guides These guides are used to connect two Units. (F) Indicators The indicators show the current operating status and power supply status of
(G) Unit specifications The specifications of the Safety CPU Unit are given.
NX-SL5500/SL5700
l
The locations where markers are attached. The markers made by OMRON are installed for the factory setting. Commercially available markers can also be installed. Refer to 3-1-2 Attaching Markers on page 3 - 4.
The protrusions to hold when removing the Unit.
These hooks are used to mount the NX Unit to a DIN Track.
the Safety CPU Unit. Refer to 2-1-3 Indicators on page 2 - 10.
2-1 Safety CPU Unit
2
2-1-2 Part Names and Functions
Let-
ter
(A) Marker attachment loca-
tion
(B) Protrusions for removing
the Unit
(C) DIN Track mounting
hook (D) NX bus connector This is the NX-series bus connector. (E) Unit hookup guides These guides are used to connect two Units. (F) Indicators The indicators show the current operating status and power supply status of
(G) Service switch This switch is used for the start trigger of various functions.
NX-series Safety Control Unit User's Manual (Z930)
Name Function
The locations where markers are attached. The markers made by OMRON are installed for the factory setting. Commercially available markers can also be installed. Refer to 3-1-2 Attaching Markers on page 3 - 4.
The protrusions to hold when removing the Unit.
This hook is used to mount the NX Unit to a DIN Track.
the Safety CPU Unit. Refer to 2-1-3 Indicators on page 2 - 10.
2 - 9
Page 76
(A)
(B
)
2 Specifications
2-1-3
Let-
ter
(H) DIP switch This switch is used for the Safety Unit Restore and the safety data logging
(I) Unit specifications The specifications of the Safety CPU Unit are given.
Name Function
function. Refer to 10-1-2 Safety Unit Restore Function on page 10 ­the Safety Unit Restore. Refer to 11-3 Safety Data Logging Operation Procedure on page 11 - 6 for details on the Safety Data Logging function.
3 for details on

Indicators

The Safety CPU Unit has indicators that show the current operating status and communications sta­tus.
WARNING
Do not use the status of the indicators on the NX-series Safety Control Units for safety operations. This will compromise the safety functions of the Unit and may cause serious injury in the event of an accident.
NX-SL3300/SL3500
Letter Name Function
(A) Model number display Displays part of the model number of the Safety CPU Unit. (B) Indicators Show the current operating status and communications status of the Safety
CPU Unit.
The rest of this section gives the indicator specifications.
TS Indicator
l
The TS indicator shows the current status of the Safety CPU Unit and the communications status with the NX bus master.
The following table lists the possible states for this indicator and what they mean.
Color Status Meaning
Green Lit. The Unit is operating normally.
2 - 10
Flashing (at 2-s intervals)
Initialization is in progress (from when the power supply is turned ON until RUN or PROGRAM mode is entered), or I/O allocation information data is being downloaded from the Sysmac Studio.
NX-series Safety Control Unit User's Manual (Z930)
Page 77
2 Specifications
Color Status Meaning
Red Lit. A hardware error, WDT error, or other critical error has occurred.
---
Flashing (at 1-s intervals)
Not lit.
An NX bus communications error, I/O allocation information data error, or other recoverable minor error that is attributed to the NX bus has occurred.
There is no Unit power supply
.
Restarting the Unit
aiting for initialization to start
W
FS Indicator
l
The FS indicator shows the safety communications status and safety function status of the Safety CPU Unit.
The following table lists the possible states for this indicator and what they mean.
Color Status Meaning
Green
Red Flashing (at 1-s in-
Green/Re
d
--- Not lit. Power is not being supplied or a fatal fault has occurred.
Lit. All FSoE connections are established and there are no errors in any
Safety CPU Unit functions.
Flashing (at 1-s in­tervals)
tervals)
Alternates at 1-s in­tervals.
One or more FSoE connections are not established or are currently being established and there are no errors in any Safety CPU Unit functions.
An FSoE communications error, program execution error, or other minor error that is attributed to the safety application has occurred. The safety application data has not been stored.
2-1 Safety CPU Unit
2
2-1-3 Indicators
*1
*1. For approximately 30 seconds after the power supply to the Safety CPU Unit is turned ON, a Safety Process
Data Communications Initialization Error event is not registered as an error if the Safety I/O Units exist. During that time, the FS indicator will flash green.
RUN Indicator
l
do not
The RUN indicator shows the execution status of the safety programs.
The following table lists the possible states for this indicator and what they mean.
Color Status Meaning
Green Lit. Execution of a safety program is in progress (operation is in progress in
RUN mode, or DEBUG mode (RUN)).
Flashing (at 1-s intervals)
---
DEBUG Indicator
l
Not lit. Operation is in progress in PROGRAM mode or DEBUG mode (STOPPED),
Initialization is in progress (from when the power supply is turned ON until RUN or PROGRAM mode is entered).
or a fatal fault has occurred.
The DEBUG indicator shows the status whether the debug function is executable on Safety CPU Unit. Refer to 6-8-3 Controlling BOOL Variables, Changing Present V
alues, and Using Forced Refresh-
ing on page 6 - 82 for the debug function of Safety CPU Unit.
The following table lists the possible states for this indicator and what they mean.
NX-series Safety Control Unit User's Manual (Z930)
2 - 11
Page 78
(A)
(B)
(C)
2 Specifications
Color Status Meaning
Yellow Lit. Operation is in progress in DEBUG mode.
--- Not lit. Operation is in progress in a mode other than DEBUG mode or a fatal fault has occur-
VALID Indicator
l
The VALID indicator shows whether safety validation has been performed. The following table lists the possible states for this indicator and what they mean.
Color Status Meaning
Yellow Lit. Safety application data from the execution of the safety validation is stored in the non-
--- Not lit. Safety application data from the execution of the safety validation is not stored in the
red.
volatile memory.
non-volatile memory, or a fatal fault has occurred.
Refer to 7-3 Operating Modes of the Safety CPU Unit
on page 7 - 11 for details on the relationship
between the operating modes of the Safety CPU Unit and the indicators.
NX-SL5500/SL5700
Letter Name Function
(A) Model number display Displays part of the model number of the Safety CPU Unit. (B) Seven-segment Indicator Displays detailed information on the Safety CPU Unit. (C) Indicators Show the current operating status and communications status of the Safety
CPU Unit.
2 - 12
The rest of this section gives the indicator specifications.
TS Indicator
l
The TS indicator shows the current status of the Safety CPU Unit and the communications status with the NX Bus Master.
The following table lists the possible states for this indicator and what they mean.
NX-series Safety Control Unit User's Manual (Z930)
Page 79
Color Status Meaning
Green Lit The Unit is operating normally.
2 Specifications
Flashing (at 2-s intervals) Initialization is in progress (from when the power supply is
turned ON until RUN or PROGRAM mode is entered), or I/O allocation information data is being downloaded from the Sysmac Studio.
Red
--- Not lit
Lit A hardware error, WDT error, or other critical error has oc-
curred.
Flashing (at 1-s intervals) An NX bus communications error, I/O allocation information
data error, or other recoverable minor error that is attributed to the NX bus has occurred.
There is no Unit power supply
The Unit is restarting
Waiting for initialization to start
NS Indicator
l
The NS indicator shows the CIP Safety communications status of the Safety CPU Unit.
The following table lists the possible states for this indicator and what they mean.
Color Status Meaning
Green Lit The CIP Safety connections are established.
Flashing (at 1-s intervals) The CIP Safety connections are not established.
2-1 Safety CPU Unit
2
2-1-3 Indicators
Red Flashing (at 1-s intervals)
--- Not lit The CIP Safety communications are not executed.
*1. For approximately 30 seconds after the power supply to the Safety CPU Unit is turned ON, the CIP Safety
Target Does Not Exist
FS Indicator
l
is not registered as an error. During that time, the NS indicator will flash red.
A CIP Safety communications error occurred.
*1
The FS indicator shows the FSoE communications status of the Safety CPU Unit.
The following table lists the possible states for this indicator and what they mean.
Color Status Meaning
Green Lit All FSoE connections are established.
Flashing (at 1-s intervals) The FSoE connections are being established.
Red Flashing (at 1-s intervals)
--- Not lit FSoE communications are not executed.
*1. For approximately 30 seconds after the power supply to the Safety CPU Unit is turned ON, a FSoE Master
Connection Not Established Error event is not registered as an error if the Safety I/O Units do not exist. Dur­ing that time, the FS indicator will flash green.
An FSoE communications error occurred.
*1
NX-series Safety Control Unit User's Manual (Z930)
2 - 13
Page 80
2 Specifications
P ERR Indicator
l
The P ERR indicator shows the error status of the running program or settings of the Safety CPU Unit.
The following table lists the possible states for this indicator and what they mean.
Color Status Meaning
Red Lit The safety program, CIP Safety communications, and
--- Not lit No errors in the running program or settings
RUN Indicator
l
The RUN indicator shows the execution status of the programs for the Safety CPU Unit.
FSoE communications stopped due to the running program or settings, which resulted in error.
Flashing (at 1-s intervals) Local error occurred in the running program.
The following table lists the possible states for this indicator and what they mean.
Color Status Meaning
Green Lit Execution of a safety program is in progress (operation is in
progress in RUN mode, or DEBUG mode (RUN)).
Flashing (at 1-s intervals) Initialization is in progress (from when the power supply is
turned ON until RUN or PROGRAM mode is entered).
--- Not lit Operation is in progress in PROGRAM mode or DEBUG mode (STOPPED), or a fatal fault has occurred.
DEBUG Indicator
l
The DEBUG indicator shows the status whether the debug function can be executed on Safety CPU Unit. Refer to 6-8-3 Controlling BOOL Variables, Changing Present V
alues, and Using Forced Refresh-
ing on page 6 - 82 for the debug function of Safety CPU Unit.
The following table lists the possible states for this indicator and what they mean.
Color Status Meaning
Yellow
--- Not lit Operation is in progress in a mode other than DEBUG
Lit Operation is in progress in DEBUG mode. (the debug func-
tion can be executed)
mode or a fatal fault has occurred. (the debug function can­not be executed)
2 - 14
VALID Indicator
l
The VALID indicator shows whether safety validation has been performed on the safety application data in the Safety CPU Unit.
The following table lists the possible states for this indicator and what they mean.
NX-series Safety Control Unit User's Manual (Z930)
Page 81
2 Specifications
Color Status Meaning
Yellow Lit Safety application data from the execution of the safety vali-
dation is stored in the non-volatile memory.
---
Seven-segment Indicator
l
The two-digit seven-segment indicator shows the detailed information on the Safety CPU Unit.
Not lit Safety application data from the execution of the safety vali-
dation is not stored in the non-volatile memory, or a fatal fault has occurred.
2-1 Safety CPU Unit
Item Meaning
At normal operation It shows the lowest one byte of the safety signature for the safety pro-
gram that is operating. If the safety signature is not confirmed, “—“ is dis­played. While a CIP Safety originator connection is being established, the indica­tor flashes. When all the CIP Safety originator connections are establish­ed, the indicator is lit.
When an error occurs Refer to 12-2-1 Troubleshooting the Main Errors in the Safety CPU Unit
12 - 3.
101.
3.
on page 11 - 7.
When a signature code is checked
When the Safety Unit Restore is executed
When the Safety Data Logging is executed
on page Refer to A-14 Checking the Signature Code on the Seven-segment Indi-
cator on page A ­Refer to 10-1-2 Safety Unit Restore Function on page 10 -
Refer to 11-4 Checking the Logging Status
2
2-1-3 Indicators
NX-series Safety Control Unit User's Manual (Z930)
2 - 15
Page 82
2 Specifications
2-2
2-2-1

Safety Input Unit

This section describes the models and specifications of the Safety Input Units as well as the names and functions of the parts.

Models and Specifications

The Safety Input Unit specifications are described below.
Models
The following table specifies the list of Safety Input Unit models.
Number of
Model
NX-SIH400 4 points 2 points Sinking in-
NX-SID800 8 points 2 points Sinking in-
safety in-
put points
Number
of test output points
Internal I/O
common
puts (PNP)
puts (PNP)
Rated
input
voltage
24 VDC Can be con-
24 VDC Cannot be
OMRON
Special
Safety Input
Devices
nected.
connected.
Number
of safety
slave
connec-
tions
1 Free-Run re-
1 Free-Run re-
I/O refresh­ing method
freshing
freshing
General Specifications
This section provides the general specifications of the Safety Input Unit.
Item Specification
Enclosure Mounted in a panel (open) Grounding method Ground to 100 Ω or less
2 - 16
NX-series Safety Control Unit User's Manual (Z930)
Page 83
2 Specifications
Item Specification
Operating environment Ambient operating tem-
perature
Ambient operating humid­ity
Atmosphere Must be free from corrosive gases.
Ambient storage tempera­ture
Altitude 2,000 m max. Pollution degree Pollution degree 2 or less: Conforms to JIS B 3502
Noise immunity Conforms to IEC 61 Insulation class CLASS III (SELV) Overvoltage category Category II: Conforms to JIS B 3502 and IEC 61131-2 EMC immunity level Zone B Vibration resistance Conforms to IEC 60068-2-6
Shock resistance Conforms to IEC 60068-2-27
Isolation method Photocoupler isolation Insulation resistance 20 MΩ Dielectric strength 510 VAC between isolated circuits for 1 minute at a
Installation method DIN Track (IEC 60715 TH35-7.5/TH35-15)
0 to 55°C
10% to 95% (with no condensation or icing)
−25 to 70°C (with no condensation or icing)
and IEC 61
5 to 8.4 Hz with amplitude of 3.5 mm
8.4 to 150 Hz, acceleration of 9.8 m/s 100 min. in each X, Y 10 min. each = 100 min. total)
147 m/s2, 3 times in each X, Y, and Z directions
leakage current of 5 mA max.
131-2
131-2, 2 kV (power supply line)
2
, and Z directions (10 sweeps of
between isolated circuits (at 100 VDC)
2-2 Safety Input Unit
2
2-2-1 Models and Specifications
Individual Specifications
This section provides the individual specifications of the Safety Input Unit.
Datasheet Items for Safety Input Unit
l
The following table gives the meaning of the datasheet items for the Safety Input Units.
Item Specification
Number of safety input points This is the number of safety input points on the Unit. Number of test output points This is the number of test output points on the Unit. The test output points
are used with the safety input terminals.
Internal I/O common This is the polarity that the Unit uses to connect to input devices. Rated input voltage This is the rated input voltage of the Unit.
OMRON Special Safety Input De­vices
Number of safety slave connec­tions
I/O refreshing method This is the I/O refreshing method for the Unit.
This tells whether the Unit supports the connection of OMRON Special Safety Input Devices (D40A Non-contact Door Switches, E3FS Single Beam Safety Sensors, etc.).
This is the number of slave connections that the Unit can have through FSoE. Y connection.
ou can perform communications with one FSoE master device per
NX-series Safety Control Unit User's Manual (Z930)
2 - 17
Page 84
2 Specifications
External connection terminals This is the type of terminal block and connector that is used to wire the
Indicators This gives the names and the layout of the indicators on the Unit. Safety input current This is the input current at the rated voltage of the safety inputs on the
Safety input ON voltage This is the input voltage at which the safety inputs on the Unit turn ON.
Safety input OFF voltage/OFF current
est output type This is the polarity that the Unit uses to connect to devices.
T Test output rated current This is the maximum load current for each test output on the Unit. Test output ON residual voltage This is the residual voltage when the test output on the Unit is ON. Test output leakage current This is the leakage current when the test output on the Unit is OFF. Dimensions (mm) These are the external dimensions of the Unit. The dimensions are given
Isolation method This is the method that is used to isolate the input circuits from the internal
Insulation resistance This is the insulation resistance between the input circuits and the internal
Dielectric strength This is the dielectric strength between the input circuits and the internal
I/O power supply method This is the method that is used to supply I/O power to the Unit.
Current capacity of I/O power supply terminal
NX Unit power consumption This is the power consumption of the Unit from the NX bus power supply.
Current consumption from I/O power supply
Weight This is the weight of the Unit. Circuit layout This is the internal circuits of the Unit. Terminal connection diagram This is the connection diagram between the Unit and connected external
Installation orientation and re­strictions
Protective functions These are the protective functions that are supported by the Unit.
Item Specification
Unit. This specification includes the number of terminals for a screwless clamping terminal block.
Unit.
These are the input voltage and input current at which the safety inputs on the Unit turn OFF
in the form W × H × D. The dimensions are given in millimeters.
circuits of the Unit.
circuits of the Unit.
circuits of the Unit.
This is the current capacity of the I/O power supply terminals (IOV/IOG) on the Unit. When you supply I/O power to external devices that are con­nected to the Unit, make sure that the total power does not exceed this value.
This is the current consumption of the Unit from the I/O power supply. This value does not include the load current of any external connection loads or the current consumption of any connected external devices.
devices. This is the installation orientation of the Unit. If the installation orientation
imposes any restrictions on the specifications, those restrictions are also described.
.
2 - 18
NX-SIH400
l
Item Specification
Number of safety input points 4 points Number of test output points 2 points Internal I/O common PNP (sinking inputs) Rated input voltage 24 VDC (20.4 to 28.8 VDC)
OMRON Special Safety Input De­vices
Number of safety slave connec­tions
Can be connected.
1
NX-series Safety Control Unit User's Manual (Z930)
Page 85
[IN] indicator
[I
N ERR] indicator
Internal Circuits
T0 – 1
Terminal block
Si0 – 3
I/O power supply +
I/O power supply -
NX bus
connector
(left)
I/O power supply +
I/O power supply -
NX bus
connector
(right)
2 Specifications
Item Specification
I/O refreshing method Free-Run refreshing External connection terminals Screwless clamping terminal block (8 terminals) Indicators [TS] indicator, [FS] indicator, [IN] indicator, [IN ERR] indicator
Safety input current 4.5 mA typical Safety input ON voltage 11 VDC min.
Safety input OFF voltage/OFF current
Test output type Sourcing outputs (PNP) Test output rated current 25 mA max. Test output ON residual voltage 1.2 V max. (IOV and all output terminals) Test output leakage current 0.1 mA max. Dimensions (mm) 12 × 100 × 71 (W × H × D) Isolation method Photocoupler isolation Insulation resistance 20 MΩ min. between isolated circuits (at 100 VDC) Dielectric strength 510 VAC between isolated circuits for 1 minute at a leakage current of 5
I/O power supply method Power supplied from the NX bus
Current capacity of I/O power supply terminals
NX Unit power consumption
Current consumption from I/O power supply
Weight 70 g max.
Circuit layout
5 VDC max./1 mA max.
mA max.
No applicable terminals.
Connected to a CPU Unit or a Communication Control Unit
1.10 W max.
Connected to a Communications Coupler Unit
0.70 W max.
20 mA max.
2-2 Safety Input Unit
2
2-2-1 Models and Specifications
NX-series Safety Control Unit User's Manual (Z930)
2 - 19
Page 86
Si0
Safety Input Unit
NX-SIH400
A1 B1
A8 B8
Si1
T0 T1
Si2 Si3
T0 T1
Safety Switch
[IN] indicator[I
N ERR] indicator
2 Specifications
Terminal connection diagram Si0 to Si3: Safety input terminals
Installation orientation and re­strictions
Protective functions Overvoltage protection circuit and short detection (test outputs)
*1. Only NX102 CPU Units and Communication Control Units can be connected. NX1P2 CPU Units cannot be
connected.
Item Specification
T0, T1: Test output terminals
Refer to 4-3-1 Safety Input Function on page 4 - 10 for details. Installation orientation:
Connected to a CPU Unit or a Communication Control Unit
Possible in the upright installation orientation.
Connected to a Communications Coupler Unit
Six possible orientations. Restriction: Maximum ambient temperature is 50°C for any orientation oth­er than upright installation.
*1
NX-SID800
l
Item Specification
Number of safety input points 8 points Number of test output points 2 points Internal I/O common PNP (sinking inputs) Rated input voltage 24 VDC (20.4 to 28.8 VDC)
OMRON Special Safety Input De­vices
Number of safety slave connec­tions
I/O refreshing method Free-Run refreshing External connection terminals Screwless clamping terminal block (16 terminals) Indicators [TS] indicator, [FS] indicator, [IN] indicator, [IN ERR] indicator
Safety input current 3.0 mA typical Safety input ON voltage 15 VDC min.
Cannot be connected.
1
2 - 20
NX-series Safety Control Unit User's Manual (Z930)
Page 87
Internal Circuits
T0–1
Terminal block
Si0–7
I/O power supply +
I/O power supply -
I/O power supply +
I/O power supply -
NX bus
connector (left)
NX bus connector (right)
Si0
Safety Input Unit
NX-SID800
Safety Switch
A1 B1
A8 B8
Si1
T0 T1
Si2 Si3
T0 T1
Si4 Si5
T0 T1
Si6 Si7
T0 T1
2 Specifications
Item Specification
Safety input OFF voltage/OFF current
Test output type Sourcing outputs (PNP) Test output rated current 50 mA max. Test output ON residual voltage 1.2 V max. (IOV and all output terminals) Test output leakage current 0.1 mA max. Dimensions (mm) 12 × 100 × 71 (W × H × D) Isolation method Photocoupler isolation Insulation resistance 20 MΩ min. between isolated circuits (at 100 VDC) Dielectric strength 510 VAC between isolated circuits for 1 minute at a leakage current of 5
I/O power supply method Power supplied from the NX bus
Current capacity of I/O power supply terminals
NX Unit power consumption
Current consumption from I/O power supply
Weight 70 g max.
Circuit layout
5 VDC max./1 mA max.
mA max.
No applicable terminals.
Connected to a CPU UNIT or a Communication Control Unit
1.10 W max.
Connected to a Communications Coupler Unit
0.75 W max.
20 mA max.
2-2 Safety Input Unit
2
2-2-1 Models and Specifications
NX-series Safety Control Unit User's Manual (Z930)
Terminal connection diagram Si0 to Si7: Safety input terminals
T0, T1: Test output terminals
Refer to 4-3-1 Safety Input Function on page 4 - 10 for details.
2 - 21
Page 88
(C)
(D)
(H)
(G)
(F)
(C)
(A)
(E)
(C)(E)
(C)
(B)
(B)
2 Specifications
Installation orientation and re­strictions
Protective functions Overvoltage protection circuit and short detection (test outputs)
*1. Only NX102 CPU Units and Communication Control Units can be connected. NX1P2 CPU Units cannot be
connected.
Item Specification
Installation orientation:
Connected to a CPU Unit or a Communication Control Unit
Possible in the upright installation orientation.
Connected to a Communications Coupler Unit
Six possible orientations. Restriction: Maximum ambient temperature is 50°C for any orientation oth­er than upright installation.
*1
2-2-2

Part Names and Functions

This section provides the names and functions of the parts of the Safety Input Unit.
Letter Name Function
(A) Marker attachment loca-
tion
(B) NX bus connector This is the NX-series bus connector. (C) Unit hookup guides These guides are used to connect two Units. (D) DIN Track mounting
(E) Protrusions for removing
(F) Indicators The indicators show the current operating status of the Safety Input Unit or
(G) Terminal block The terminal block is used to connect external devices. (H) Unit specifications The specifications of the Safety Input Unit are given here.
hooks
the Unit
The locations where markers are attached. The markers made by OMRON are installed for the factory setting. Commercially available markers can also be installed. Refer to 3-1-2 Attaching Markers on page 3 - 4.
These hooks are used to mount the NX Unit to a DIN Track.
The protrusions to hold when removing the Unit.
signal input status. Refer to 2-2-3 Indicators on page 2 - 24.
2 - 22
NX-series Safety Control Unit User's Manual (Z930)
Page 89
Terminal Blocks
8-terminal type
(B)
16-terminal type
(C)
(A)
A1
A2
A3
A4
A5
A6
A7
A8
B1
B2
B3
B4
B5
B6
B7
B8
A1
A2
A3
A4
A5
A6
A7
A8
B1
B2
B3
B4
B5
B6
B7
B8
8-terminal type
(B)
16-terminal type
(C)
(A)
A1
A2
A3
A4
A5
A6
A7
A8
B1
B2
B3
B4
B5
B6
B7
B8
A1
A2
A3
A4
A5
A6
A7
A8
B1
B2
B3
B4
B5
B6
B7
B8
2 Specifications
There are two models of screwless clamping terminal blocks: NX-TB£££2 and NX-TB£££1. The following models of Terminal Blocks can be mounted to Safety Input Units.
£££2
NX-TB
2-2 Safety Input Unit
2
2-2-2 Part Names and Functions
NX-TB£££1
NX-series Safety Control Unit User's Manual (Z930)
2 - 23
Page 90
2 Specifications
Letter Name Function
(A) Terminal number
(B) Release holes Insert a flat-blade screwdriver into these holes to connect or remove the wires.
(C) Terminal holes The wires are inserted into these holes.
Terminal Blocks for Safety Input Units come in two types depending on the number of terminals that can be used. There are 8-terminal and 16-terminal Terminal Blocks. The terminal block must have the same number of terminals that the Unit is designed for.
The 8-terminal type does not have terminal holes and release holes for the following terminals.
• A2, A4, A6, A8, B2, B4, B6, and B8.
The terminal numbers are given by column letters A and B, and row numbers 1 to 8.
indications
The combination of the "column" and "row" A8 and B1 to B8. The terminal number indicators are the same regardless of the number of terminals on the terminal block, as shown above.
Additional Information
gives the terminal numbers from A1 to
There are two types of Terminal Blocks in terms of current capacity, 10 A for the NX-TB£££2 Termi­nal Blocks and 4 A for the NX-TB
£££1 Terminal Blocks. To differentiate between the two types of Terminal Blocks, use the terminal number column indications. The Terminal Block with white letters on a dark background is the NX-TB£££2 Terminal Block. You can mount either type of Terminal Block to a Unit with a terminal current capacity of 4 A max. You can only mount the NX-TB£££2 Terminal Block to the Units that the current capacity specifica­tion of the terminals is greater than 4 A.
• Applicable Terminal Blocks for Each Unit Model The following table gives the Terminal Blocks that are applicable to each Unit.
Unit model number
NX-SIH400 NX-TBA081 8 Not provided 4 A
NX-SID800 NX-TBA161 16 Not provided 4 A
Model number Number of terminals Ground terminal mark Current capacity
NX-TBA082 10 A
NX-TBA162 10 A
Terminal block
Precautions for Correct Use
You can mount either NX-TB£££1 or NX-TB£££2 Terminal Block to a Unit with a terminal current capacity of 4 A. Even if you mount an NX-TB
£££2 Terminal Block, the current specification does not change because the terminal current capacity of the Unit is 4 A. Refer to the I/O power supply terminal current capacities given in Individual Specifications on page 2 - 17 for the terminal current capacity specifications of the Units. Refer to A-11 List of Screwless Clamping Terminal Block Models on page A - 96 or the model numbers of the Terminal Blocks.
2-2-3
2 - 24

Indicators

This section describes the indicators of the Safety Input Unit.
NX-series Safety Control Unit User's Manual (Z930)
Page 91
WARNING
Unit with 4 I/O Points Unit with 8 I/O Points
(A)
(B)
IN
ININ ERR
IN ERR
2 Specifications
Do not use the status of the indicators on the NX-series Safety Control Units for safety operations. This will compromise the safety functions of the Unit and may cause serious injury in the event of an accident.
The indicator pattern depends on the number of input points, as shown below.
Letter Name Function
(A) Model number dis-
play
(B) Indicators Show the current operating status and communications status of the Safety I/O
Displays part of the model number of the Safety I/O Units. The model number indication is red on all Safety Control Units.
Units.
2-2 Safety Input Unit
2
2-2-3 Indicators
Safety Input Unit Operation Status Indicators
Indicators to show the operation status of the Safety Input Unit are located in the center of the front side of the Safety Input Unit.
The following section describes the specifications of each indicator.
TS Indicator
l
The TS indicator shows the current status of the Safety Input Unit and its communications status with the NX Bus Master.
NX-series Safety Control Unit User's Manual (Z930)
2 - 25
Page 92
2 Specifications
The following table lists the possible states for this indicator and what they mean.
Color Status Meaning
Green Lit The Unit is operating normally.
Red
--- Not lit
FS Indicator
l
Flashing (at 1-s intervals) Initializing, or I/O allocation information data is being down-
loaded from the Sysmac Studio.
Lit A hardware error, WDT error, or other critical error has oc-
curred.
Flashing (at 1-s intervals) An NX bus communications error, I/O allocation information
data error, or other recoverable minor error that is attributed to the NX bus has occurred.
There is no Unit power supply
Restarting the Unit
Waiting for initialization to start
The FS indicator shows the FSoE communications status and safety function status of the Safety Input Unit.
The following table lists the possible states for this indicator and what they mean.
Color Status Meaning
Green Lit The FSoE connections are established and there are no er-
rors in any Safety I/O Units functions.
Flashing (at 1-s intervals) The FSoE connections are being established.
Red Flashing (at 1-s intervals) An FSoE communications error, safety input terminal error,
or other minor error has occurred.
--- Not lit Power is not being supplied or a fatal fault has occurred.
IN Indicator
l
The IN indicator shows the signal input status of the safety input terminal.
The following table lists the possible states for this indicator and what they mean.
Color Status Meaning
Yellow
Lit The safety input terminal is ON and there are no errors.
2 - 26
--- Not lit The safety input terminal is OFF or an error has occurred.
IN ERR Indicator
l
The IN ERR indicator shows the error status of the safety input terminal.
The following table lists the possible states for this indicator and what they mean.
Color Status Meaning
Red Lit An error has occurred in the safety input terminal.
Flashing (at 1-s intervals) An error has occurred in the safety input terminal for the
other channel of the dual channel I/O.
NX-series Safety Control Unit User's Manual (Z930)
Page 93
2 Specifications
Color Status Meaning
--- Not lit An error has occurred in the safety input terminal.
Refer to 12-2-1 Troubleshooting the Main Errors in the Safety CPU Unit on page on the relationship between the errors of the Safety Input Unit and the indicators.
12 - 3 for details
2-2 Safety Input Unit
2
2-2-3 Indicators
NX-series Safety Control Unit User's Manual (Z930)
2 - 27
Page 94
2 Specifications
2-3
2-3-1

Safety Output Unit

This section describes the models and specifications of the Safety Output Units as well as the names and functions of the parts.

Models and Specifications

The Safety Output Unit specifications are described below.
Models
The following table specifies the list of the Safety Output Unit models.
Number
Number of
Model
NX-SOH200 2 points Sourcing out-
NX-SOD400 4 points Sourcing out-
safety out-
put points
Internal I/O
common
puts (PNP)
puts (PNP)
Maximum load
current
2.0 A/point,
4.0 A/Unit at 40°C
2.5 A/Unit at 55°C
0.5 A/point and
2.0 A/Unit
Rated
voltage
24 VDC 1 Free-Run re-
24 VDC 1 Free-Run re-
of safety
slave
connec-
tions
I/O refreshing
method
freshing
freshing
General Specifications
This section provides the general specifications of the Safety Output Unit.
Item Specification
Enclosure Mounted in a panel (open) Grounding method Ground to 100 Ω or less
2 - 28
NX-series Safety Control Unit User's Manual (Z930)
Page 95
2 Specifications
Item Specification
Operating environment Ambient operating tem-
perature
Ambient operating humid­ity
Atmosphere Must be free from corrosive gases.
Ambient storage tempera­ture
Altitude 2,000 m max. Pollution degree Pollution degree 2 or less: Conforms to JIS B 3502
Noise immunity Conforms to IEC 61 Insulation class CLASS III (SELV) Overvoltage category Category II: Conforms to JIS B 3502 and IEC 61131-2 EMC immunity level Zone B Vibration resistance Conforms to IEC 60068-2-6
Shock resistance Conforms to IEC 60068-2-27
Isolation method Photocoupler isolation Insulation resistance 20 MΩ Dielectric strength 510 VAC between isolated circuits for 1 minute at a
Installation method DIN Track (IEC 60715 TH35-7.5/TH35-15)
0 to 55°C
10% to 95% (with no condensation or icing)
−25 to 70°C (with no condensation or icing)
and IEC 61
5 to 8.4 Hz with amplitude of 3.5 mm
8.4 to 150 Hz, acceleration of 9.8 m/s 100 min. in each X, Y 10 min. each = 100 min. total)
147 m/s2, 3 times in each X, Y, and Z directions
leakage current of 5 mA max.
131-2
131-2, 2 kV (power supply line)
2
, and Z directions (10 sweeps of
between isolated circuits (at 100 VDC)
2-3 Safety Output Unit
2
2-3-1 Models and Specifications
Individual Specifications
This section provides the individual specifications of the Safety Output Unit.
Datasheet Items for Safety Output Unit
l
The following table gives the meaning of the datasheet items for the Safety Output Units.
Item Specification
Number of safety output points This is the number of safety output points on the Unit. Internal I/O common This is the polarity that the Unit uses to connect to output devices. Maximum load current This is the maximum load current for outputs on the Unit. A specifica-
tion is given for each output and each Unit.
Rated voltage This is the rated voltage of the outputs on the Unit.
Number of safety slave connec­tions
I/O refreshing method The I/O refreshing methods that are used by the Unit. External connection terminals The type of terminal block and connector that is used for connecting
Indicators This gives the names and the layout of the indicators on the Unit.
This is the number of slave connections that the Unit can have through FSoE. Y per connection.
the Unit. This specification includes the number of terminals for a screwless clamping terminal block.
ou can perform communications with one FSoE master device
NX-series Safety Control Unit User's Manual (Z930)
2 - 29
Page 96
2 Specifications
Safety output rated current This is the maximum load current for safety outputs on the Unit. The
Safety output ON residual voltage This is the residual voltage when a safety output on the Unit is ON. Safety output OFF residual voltage This is the residual voltage when a safety output on the Unit is OFF. Safety output leakage current This is the leakage current when a safety output on the Unit is OFF. Dimensions (mm) These are the external dimensions of the Unit. The dimensions are giv-
Isolation method This is the method that is used to isolate the output circuits from the
Insulation resistance This is the insulation resistance between the output circuits and the in-
Dielectric strength This is the dielectric strength between the output circuits and the inter-
I/O power supply method The method for supplying I/O power for the Unit.
Current capacity of I/O power sup­ply terminal
NX Unit power consumption This is the power consumption of the Unit from the NX bus power sup-
Current consumption from I/O pow­er supply
eight This is the weight of the Unit.
W Circuit layout This is the internal circuits of the Unit. Terminal connection diagram This is the connection diagram between the Unit and external devices.
Installation orientation and restric­tions
Protective functions These are the protective functions that are supported by the Unit.
Item Specification
inrush current of the external connection load must be lower than this value.
en in the form W × H × D. The dimensions are given in millimeters.
internal circuits of the Unit.
ternal circuits of the Unit.
nal circuits of the Unit.
This is the current capacity of the I/O power supply terminals (IOV/ IOG) on the Unit. When you supply I/O power to external devices that are connected to the Unit, make sure that the total power does not ex­ceed this value.
.
ply This is the current consumption of the Unit from the I/O power supply.
This value does not include the load current of any external connection loads or the current consumption of any connected external devices.
This is the installation orientation of the Unit. If the installation orienta­tion imposes any restrictions on the specifications, those restrictions are also described.
2 - 30
NX-SOH200
l
Item Specification
Number of safety output points
Internal I/O common
Maximum load current
Rated input voltage
Number of safety slave connections
I/O refreshing method
2 points
PNP (sourcing outputs)
2.0 A/point
4.0 A/Unit at 40°C
2.5 A/Unit at 55°C The maximum load current depends on the installation orientation and ambient temperature.
24 VDC (20.4 to 28.8 VDC)
1
Free-Run refreshing
NX-series Safety Control Unit User's Manual (Z930)
Page 97
Item Specification
[OUT] indicator
[O
UT ERR] indicator
I/O power supply -
NX bus connector (right)
Internal Circuits
So0–1
Terminal block
IOG
I/O
power
supply +
I/O
power
supply -
I/O power supply +
NX bus connector
(left)
External con-
Screwless clamping terminal block (8 terminals)
nection termi­nals
Indicators [TS] indicator, [FS] indicator, [OUT] indicator, [OUT ERR] indicator
2 Specifications
2-3 Safety Output Unit
Safety output
1.2 V max. (between IOV and all output terminals)
ON residual voltage
Safety output
2 V max. (between IOG and all output terminals)
OFF residual voltage
Safety output
0.1 mA max.
leakage cur­rent
Dimensions
12 × 100 × 71 (W × H × D)
(mm)
Isolation meth-odPhotocoupler isolation
Insulation re-
20 MΩ min. between isolated circuits (at 100 VDC)
sistance
Dielectric
510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max.
strength
I/O power sup-
Power supplied from the NX bus
ply method
Current ca-
IOG: 2 A/terminal max.
pacity of I/O power supply terminals
NX Unit power consumption
Connected to a CPU UNIT or a Communication Control Unit
1.05 W max.
Connected to a Communications Coupler Unit
0.70 W max.
Current con­sumption from I/O power sup­ply
Weight 65 g max.
Circuit layout
40 mA max.
2
2-3-1 Models and Specifications
NX-series Safety Control Unit User's Manual (Z930)
2 - 31
Page 98
So0
Safety Output Unit
NX-SOH200
A1 B1
A8 B8
So1
L L
IOG IOG
NC NC
NC NC
2 Specifications
Item Specification
Terminal con­nection dia­gram
So0 to So1: Safety output terminals IOG: I/O power supply 0 V
Refer to 4-3-2 Safety Output Function on page 4 - 32 for details.
2 - 32
NX-series Safety Control Unit User's Manual (Z930)
Page 99
Item Specification
2
1
0
4
3
2
0
30 40 5550100
Load current [A]
Ambient Operating Temperature (°C)
2.5 A
2
1
0
4
3
2
0
30 40 50100
Load current [A]
Ambient Operating Temperature (°C)
Installation orientation and restric­tions
Installation orientation:
Connected to a CPU Unit or a Communication Control Unit
Possible in the upright installation orientation.
Connected to a Communications Coupler Unit
Six possible orientations. Restriction: For upright installation, the ambient temperature is restricted as shown below ac­cording to the total Unit load current.
2 Specifications
*1
2-3 Safety Output Unit
2
2-3-1 Models and Specifications
For all installation orientations other than upright installation, the ambient temperature is re­stricted as shown below according to the total Unit load current.
Protective functions
*1. Only NX102 CPU Units and Communication Control Units can be connected. NX1P2 CPU Units cannot be
connected.
NX-SOD400
l
Number of safety output points
Internal I/O common PNP (sourcing outputs) Maximum load current 0.5 A/point and 2.0 A/Unit Rated input voltage 24 VDC (20.4 to 28.8 VDC)
Number of safety slave connections
Overvoltage protection circuit and short detection
Item Specification
4 points
1
NX-series Safety Control Unit User's Manual (Z930)
2 - 33
Page 100
[OUT] indicator
[OUT ERR] indicator
Internal Circuits
So0 – 3
Terminal block
IOG
I/O power supply +
I/O power supply -
NX bus connector
(left)
I/O power supply +
I/O power supply -
NX bus connector
(right)
2 Specifications
I/O refreshing method Free-Run refreshing
External connection ter­minals
Indicators [TS] indicator, [FS] indicator, [OUT] indicator, [OUT ERR] indicator
Item Specification
Screwless clamping terminal block (8 terminals)
Safety output ON residual
1.2 V max. (between IOV and all output terminals)
voltage
Safety output OFF residu-
2 V max. (between IOG and all output terminals)
al voltage
Safety output leakage cur-
0.1 mA max.
rent Dimensions (mm) 12 × 100 × 71 (W × H × D) Isolation method Photocoupler isolation Insulation resistance 20 MΩ min. between isolated circuits (at 100 VDC) Dielectric strength 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max. I/O power supply method Power supplied from the NX bus
Current capacity of I/O power supply terminals
NX Unit power consump­tion
IOG (A3 and B3): 2 A/terminal max. IOG (A7 and B7): 0.5 A/terminal max.
Connected to a CPU UNIT or a Communication Control Unit
1.10 W max.
Connected to a Communications Coupler Unit
0.75 W max.
Current consumption from I/O power supply
Weight 65 g max.
Circuit layout
60 mA max.
2 - 34
NX-series Safety Control Unit User's Manual (Z930)