Omron H7CZ-L8, H7CZ-L8D1, H7CZ User Manual

New Product
Digital Counter
H7CZ
Easy to Use and Easy to Read.
Basic Features
• Character height of 10 mm for better readability.
• Operation is simplified by the Up Key for each digit.
Safety and Reliability
• Power supply circuit and input circuits are isolated inside the Counter.
• Set value limit function prevents unexpected operation of output devices caused by setting mistakes.
• Output counter function helps in managing the service life of the Counter or the load.
Other Features
• Waterproof, dust-proof structure (UL508 Type 4X and IP66).
• Key protection.
Refer to Safety Precautions on page 17.
For the most recent information on models that have been certified for safety standards, refer to your OMRON website.
Features
Basic Features
Better Readability
Character Height of 10 mm with a Wide Viewing Angle.
Easy to read from the top, bottom, and sides.
(actual size)
10 mm
The Easiest Operation
Operation is simplified by the Up Key for each digit.
Safety and Reliability
Isolated Power Supply and Input Circuits
Power supply circuit and input circuits are isolated inside the Counter. Previous non-isolated counters had wiring restrictions and could be damaged if wired incorrectly. The H7CZ removes these worries.
Clear
Confirmation
Set Value Limit
You can set an upper limit for the set value to prevent unexpected operation of output devices caused by setting mistakes.
Setting the upper limit of the set value enables worry-free operation.
For 1,000 pieces
No overflow
Output Counter
The output counter counts the number of times the output turns ON (alarms can be displayed and the count can be monitored in increments of 1,000 operations). This counter is useful in managing the service life of the Counter or the load.
Other Features
Waterproof, Dust-proof Structure (UL508 Type 4X and IP66)
Worry-free application is possible in locations subject to water.
Note: When the Y92S-29 Waterproof Packing is used.
Key Protection
Select from any of seven protection patterns. Use the best one for the application.
1
H7CZ
Model Number Structure
Model Number Legend
H7CZ-L@@
12
1. External connections 2. Supply voltage
Symbol Meaning
8 8-pin socket
Symbol Meaning
None 100 to 240 VAC at 50/60 Hz
D1 12 to 24 VDC/24 VAC at 50/60 Hz
Ordering Information
List of Models
Type Configuration
H7CZ
Note: The functions that are provided depend on the model. Check detailed specifications before ordering.
• 1-stage preset counter
External
connections
8-pin socket 1-stage 6 digits Contact output (SPDT)
Settings
Accessories (Order Separately)
Soft Cover
Model Page
Y92A-48F1 9
Display
digits
Outputs
Power supply
voltage
100 to 240 VAC H7CZ-L8
12 to 24 VDC/24 VAC H7CZ-L8D1
Model
Hard Cover
Model Page
Y92A-48 9
Flush Mounting Adapter
Model Page
Y92F-30 9
Waterproof Packing
Model Page
Y92S-29 9
Connection Sockets
Model Type Remarks Page
P2CF-08 Front-connecting Socket ---
P2CF-08-E Front-connecting Socket (Finger-safe Type)
P3G-08 Back-connecting Sockets
Round crimp terminals cannot be used on Finger-safe Sockets. Use forked crimp terminals.
A Y92A-48G Terminal Cover can be used with the Socket to create a finger-safe construction.
Terminal Covers for P3G-08 Back-connecting Socket
Model Page
Y92A-48G 10
10
2
H7CZ
H7CZ Multifunction Preset Counter
Specifications
Ratings
Item Models H7CZ-L8 H7CZ-L8D1
Configuration 1-stage preset counter
Power supply voltage
Ratings
Mounting method Flush mounting or surface mounting
External connections 8-pin socket
Degree of protection IEC IP66, UL508 Type 4X (indoors) for panel surface only and only when Y92S-29 Waterproof Packing is used.
Input signals Count, Reset
Counter
Prescaling function Yes (0.001 to 99.999)
Decimal point adjustment Yes (rightmost 3 digits)
Sensor waiting time 290 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.)
Input method
Control output
Display
Digits
Memory backup EEPROM (overwrites: 100,000 times min.) that can store data for 10 years min.
Operating temperature range 10 to 55°C (10 to 50°C if Counters are mounted side by side) (with no icing or condensation)
Storage temperature range 25 to 70°C (with no icing or condensation)
Operating humidity range 25% to 85%
Front panel color Light gray (5Y7/1)
*1. Do not use the output from an inverter as the power supply.The ripple must be 20% maximum for DC power. *2. The display is lit only when the power is ON. Nothing is displayed when power is OFF.
Operating voltage fluctuation range
Power consumption Approx. 9.4 VA at 100 to 240 VAC, Approx. 7.2 VA/4.7 W at 24 VAC/12 to 24 VDC
Maximum counting speed 30 Hz or 10 kHz (switchable) (ON/OFF ratio 1:1)
Input mode Increment, Decrement
Output mode N, F, C, R, K-1, P, Q, and A.
One-shot output time 0.01 to 99.99 s
Reset system
*2
*1
100 to 240 VAC, 50/60 Hz 24 VAC, 50/60 Hz or 12 to 24 VDC
85% to 110% of rated supply voltage (12 to 24 VDC: 90% to 110%)
External (minimum reset signal width: 1 ms or 20 ms, selectable), Manual, and Automatic reset (internal according to C, R, P, and Q mode operation)
No-voltage inputs: ON impedance: 1 kΩ max. (Leakage current: 12 mA at 0 Ω) ON residual voltage: 3 V max. OFF impedance: 100 kΩ min.
3 A at 250 VAC/30 VDC, resistive load (cosφ=1), Minimum applied load: 10 mA at 5 VDC (failure level: P, reference value)
LCD Character height Count value: 10 mm Set value: 6 mm
6 digits
99999 to 999999 (5 digits to +6 digits)
3
H7CZ
* Refer to the Life-test Curve.
Applicable Standards
*1. The following safety standards apply to H7CZ.
cUL (Listing): Applicable when an OMRON P2CF(-E) Socket is used. cUR (Recognition): Applicable when any other socket is used.
*2. Industrial electromagnetic environment (EN/IEC 61326-1 Table 2)
Insulation resistance
100 MΩ min. (at 500 VDC) between current-carrying terminals and exposed non­current-carrying metal parts, and between non-continuous contacts
Dielectric strength
2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and non-current­carrying metal parts 2,000 VAC, 50/60 Hz for 1 min between power supply and input circuit (1,000 VAC for 24 VAC/12 to 24 VDC) 1,000 VAC, 50/60 Hz for 1 min between control output, power supply, and input circuit (2,000 VAC) 1,000 VAC, 50/60 Hz for 1 min between non-continuous contacts
Impulse withstand voltage
3.0 kV between power terminals (1.0 kV for models with 24 VAC/12 to 24 VDC)
4.5 kV between current-carrying terminals and exposed non-current-carrying metal parts (1.5 kV for models with 24 VAC/12 to 24 VDC)
Noise immunity
±1.5 kV between power terminals ±600 V between input terminals Square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise)
Static immunity
Malfunction: 8 kV Destruction: 15 kV
Vibration resistance
Destruction 10 to 55 Hz with 0.75-mm single amplitude each in three directions for 2 h each
Malfunction 10 to 55 Hz with 0.35-mm single amplitude each in three directions for 10 min each
Shock re­sistance
Destruction 300 m/s2 each in three directions
Malfunction 100 m/s2 each in three directions
Life expectancy
Mechanical: 10,000,000 operations min. Electrical: 100,000 operations min. (3 A at 250 VAC, resistive load, ambient temperature condition: 23°C)
*
Weight Approx. 100 g (Counter only)
Approved safety standards
cULus (or cURus): UL508/CSA C22.2 No. 14
*1
EN 61010-1 (IEC 61010-1): Pollution degree 2/overvoltage category II B300 PILOT DUTY 1/4 HP 120 VAC, 1/3 HP, 240 VAC, 3 A resistive load VDE0106/P100 (finger protection)
EMC
(EMI) EN61326-1
*2
Emission Enclosure: EN 55011 Group 1 class A Emission AC mains: EN 55011 Group 1 class A (EMS) EN61326-1
*2
Immunity ESD: EN 61000-4-2: 4 kV contact discharge;
8 kV air discharge
Immunity RF-interference: EN 61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz);
10 V/m (Pulse-modulated, 900 MHz ±5 MHz) Immunity Conducted Disturbance: EN 61000-4-6: 10 V (0.15 to 80 MHz) Immunity Burst: EN 61000-4-4: 2 kV power-line;
1 kV I/O signal-line Immunity Surge: EN 61000-4-5: 1 kV line to lines (power and output lines);
2 kV line to ground (power and output lines) Immunity Voltage Dip/Interruption: EN 61000-4-11: 0.5 cycle, 100% (rated voltage)
Life-test Curve (Reference Values)
Resistive load
Inductive load
A current of 0.15 A max. can be switched at 125 VDC (cosφ=1) and current of 0.1 A max. can be switched if L/R=7 ms. In both cases, a life of 100,000 operations can be expected.
1,000
700
500
300
100
70
50
Load current (A)
01 2 34
30 VDC (cosφ=1)
250 VAC (cosφ=1)
No. of operations (
×
10
3
)
Characteristics
)
1,000
3
10
×
700
500
I/O Functions
Using as a Counter
Inputs
Outputs OUT Outputs signals according to the specified output mode when a set value is reached.
*1. For information on operation of I/O functions, refer to page 14 and page 15. *2. In elapsed time mode, the present value returns to 0; in remaining time mode, the present value returns to the set value.
• The following table shows the delay from when the reset signal is input until the output is turned OFF. (Reference values)
Minimum reset signal width Output delay time
4
*1
Count
Reset
• Reads counting signals.
• Increment and decrement inputs accepted.
• Resets present value and outputs.
• Counting cannot be performed during reset input.
• Reset indicator is lit while reset input is ON.
1 ms 0.8 to 1.2 ms
20 ms 15 to 25 ms
*2
300
No. of operations (
100
70
50
01 2 34
30 VDC (L/R=7 ms)
250 VAC (cosφ=1)
Load current (A)
Connections
H7CZ
Block Diagram
Output circuit
(Basic insulation)
Input circuits
(Basic insulation)
Internal
control circuit
Power supply
circuit
(Basic insulation)
Display circuit
Key switch
circuit
Terminal Arrangement
Confirm that the power supply meets specifications before use.
H7CZ-L8/L8D1
1-stage Contact Output
Internal circuit
Count
Reset
Contact Output
0V
(+) ()
Input Circuits
Count and Reset Input
No-voltage Inputs (NPN Inputs)
+14V
1 kΩ
IN
Internal circuit
Input Connections
The inputs of the H7CZ-L8@ are no-voltage (short-circuit or open) inputs.
No-voltage Inputs (NPN Inputs)
Open Collector Voltage Output Contact Input DC Two-wire Sensor
PLC or sensor
Reset input
Count input
0 V for inputs
134
Note: Operates with transistor ON.
No-voltage Input Signal Levels
Short-circuit level (transistor ON)
• Residual voltage: 3 V max.
No-contact input
Contact input Use contacts which can adequately switch 5 mA at 10 V.
Note: The DC voltage must be 30 VDC max.
• Impedance when ON: 1 kΩ max.
(The leakage current is approx. 12 mA when the impedance is 0 Ω.)
Open level (transistor OFF)
• Impedance when OFF: 100 kΩ min.
Sensor
Reset input
Count input
0 V for inputs
134
Note: Operates with transistor ON.
Reset input
Count input
0 V for inputs
134
Note: Operates with relay ON.
Reset input
0 V for inputs
134
Note: Operates with transistor ON.
Applicable Two-wire Sensor
• Leakage current: 1.5 mA max.
• Switching capacity: 5 mA min.
• Residual voltage: 3 VDC max.
• Operating voltage: 10 VDC
Count input
5
H7CZ
Nomenclature
Display Section
1. Key Protect Indicator
2. Control Output Indicator
3. Reset Indicator
4. Present Value (Main Display)
(Character height: 10 mm)
5. Set value (Sub-display)
(Character height: 6 mm)
Character Size for Main Display
10 mm
Character Size for Sub-display
6 mm
4
1
2 3
6
7
1st digit 6th digit
5
8
6. Mode Key
(Changes modes and setting items.)
7. Reset Key
8. Up Keys to
9. Key-protect Switch
9
(Default setting) OFF
Operation Keys
1 6
Switches
ON
(Disable)
(Enable)
Dimensions (Unit: mm)
Counters
H7CZ-L8/-L8D1 (Flush Mounting/Surface Mounting Models)
48 × 48
6
63.7
14.2
44.8×44.8
Panel Cutouts
Panel cutouts are as shown below. (according to DIN43700).
60 min.
+
0.6
45
0
+
0.6
45
0
15 min.
60 min.
Dimensions with Flush Mounting Adapter
H7CZ-L8/-L8D1 (Adapter and Waterproof Packing Ordered Separately)
Waterproof Packing
58
48
(51)
Y92F-30 (order separately)
Pane lY92S-29 (order separately)
Flush Mounting Adapter
84.87.5
Dimensions with Front Connecting Socket
*
92.3
H7CZ
-L8@
90
P3G-08 (order separately) Back-connecting Socket
Note: 1. The mounting panel thickness
should be 1 to 5 mm.
2. To allow easier operation, it is recommended that Adapters be mounted so that the gap between sides with hooks is at least 15 mm (i.e., with the panel cutouts separated by at least 60 mm).
3. It is possible to horizontally mount Timers side by side. Attach the Flush Mounting Adapters so that the surfaces without hooks are on the sides of the Timers. If they are mounted side-by-side, water­resistance will be lost.
n Units mounted
side by side
A
A=(48n2.5)
With Y92A-48F1 attached. A={48n2.5+(n1)×4} With Y92A-48 attached.
A=(51n5.5)
+1
0
+1
0
+1
0
P2CF-08(-E) (order separately) Front Connecting Socket
* These dimensions depend on the kind of DIN Track. (Reference value)
6
Loading...
+ 14 hidden pages