SAFETY PRECAUTIONS
H7CX-A@-N
Digital Counter
EN
INSTRUCTION MANUAL
Thank you for purchasing the OMRON Product.
To ensure the safe application of the Product, read this
manual carefully before using the Product and always keep
it close at hand when the Product is in use.
OMRON Corporation
©All Rights Reserved
For details, refer to the latest datasheet (Cat. No. M079).
Suitability for Use
OMRON shall not be responsible for conformity with any standards, codes, or regulations that
apply to the combination of the products in the customer's application or use of the product.
Take all necessary steps to determine the suitability of the product for the systems, machines,
and equipment with which it will be used. Know and observe all prohibitions of use applicable to
this product.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE
OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN
DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY
RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT
OR SYSTEM.
See also Product catalog for Warranty and Limitation of Liability.
1148203-6C
Keys to Warning Symbols
CAUTION
Do not allow pieces of metal, wire clippings, or fine metallic
shavings or fillings from installation to enter the product. Doing so
may occasionally result in electric shock, fire, or malfunction.
Minor injury due to explosion may occasionally occur. Do not use
the Counter where subject to flammable or explosive gas.
Fire may occasionally occur. Tighten the terminal screws to the rated torque.
H7CX terminals: 6.55 to 7.97 lb-in (0.74 to 0.90 N⋅m)
P2CF Socket terminals: 4.4 lb-in (0.5 N⋅m)
Minor injury due to electric shock may occasionally occur. Do not
touch any of the terminals while power is being supplied. Be sure
to mount the terminal cover after wiring.
The life expectancy of the output relay varies considerably according to its
usage. Use the output relay within its rated load and electrical life
expectancy. If the output relay is used beyond its life expectancy, its
contacts may become fused or there may be a risk of fire. Also, be sure
that the load current does not exceed the rated load current and when
using a heater, be sure to use a thermal switch in the load circuit.
Minor electric shock, fire, or malfunction may occasionally occur. Do not
disassemble, modify, or repair the Counter or touch internal components.
1) When mounting the Counter to a panel, tighten the two mounting screws alternately, a little at a time, so as
to keep them at an equal tightness. If the panel screws are tightened unequally, water may enter the panel.
2) Store the Counter at the specified temperature. If the Counter has been stored at a temperature of less than
−10°C, allow the Counter to stand at room temperature for at least 3 hours before use.
Indicates a potentially hazardous situation which, if not
avoided, is likely to result in minor or moderate injury or in
property damage.
CAUTION
Precautions for Safe Use
Mounting and Panel-cutout Dimensions Diagram
Mounting Dimensions (Unit: mm)
Front panel dimensions are the same
for all models.
48
48
Surface Mounting
H7CX
-A11@
103.2*
P2CF-11(-E)
Front-connecting Socket (order separately)
*These dimensions vary with the
type of DIN track (reference value).
100.9
Flush Mounting
H7CX-A11@-N
Y92S-29 (order separately)
Waterproof Packing
(51)
H7CX-A-N/-AS-N/-AW-N/-AWS-N/-AWD1-N/
-AWSD1-N/-A4-N/-A4S-N/-A4W-N/-AU-N/-AUD1-N/
-AUSD1-N
Y92S-29 (provided)
Waterproof
Packing
(51)
H7CX-AD-N/-ASD-N/-AWSD-N/-A4D-N/
-A4SD-N/-A4WSD-N
Y92S-29 (provided)
Waterproof
Packing
Y92F-30 (order separately)
Panel
Flush Mounting Adapter
Panel
Panel
(51)
7.5 57.5
9.985.7
Y92F-30 (provided)
Flush Mounting Adapter
76.57.5
Y92F-30 (provided)
Flush Mounting
Adapter
•
Panel-cutout Dimensions Diagram
(Unit: mm)
Standard panel cutout is shown in the
following diagram (conforms to DIN 43700).
A space of 15 mm or greater (a panel
cut-out distance of 60 mm or greater) is
recommended towards the Adapter's
hook side to enable easier mounting work.
+0.6
−0
45
@
60 or greater
1. The thickness of a mounting panel should
be 1 to 5 mm.
2. It is possible to mount Timers side-by-side.
(But only towards the non-hook side.)
n Units mounted
side-by-side
A=(48n−2.5)
3. If the products are mounted side by side,
water resistance will be lost.
58
15 or greater
A
+1
−0
Package Contents
• Digital Counter
• Instruction manual (this document)
• Mounting Adapter, Waterproof packing,
Terminal Cover (except H7CX-A11@)
• DIP switch label (
H7CX-AW@/-AU@ only)
Power supply voltage 100 to 240 VAC, 50/60 Hz (Other than
Allowable voltage fluctuation range
Power consumption Approx. 9.4 VA at 100 to 240 VAC,
Operating temperature range −10 to 55°C (−10 to 50°C if Counters are
Storage temperature range −25 to 70°C (with no icing or condensation)
Operating humidity range 25% to 85%
Recommended fuse T2A, 250VAC, time-lag, low-breaking capacity
Installation environment Over-voltage category II, pollution degree 2.
48
Display Section
1. Key Protect Indicator (orange)
2. Control Output Indicator (orange)
OUT (One-stage)
OUT (Two-stage)
1 2
3. Reset Indicator (orange)
(Lit when the reset input (1) or Reset Key is ON.)
4. Total Counter Indicator
(Lit when the total count value is displayed.)
Displayed only when other than Tachometer mode
is selected in the configuration selection mode.
5. Batch Indicator
(Lit when the batch count value is displayed.)
6. Set Value 1, 2 Stage Indicator
7. Present Value (Main Display)
(Character height: 12 mm (6-digit: 10 mm), red*)
* Characters on models with terminal blocks
(except H7CX-A11@) can be switched between
red, green, and orange.
H7CX-@D1/-@D)
12 to 24 VDC/24 VAC, 50/60 Hz (H7CX-@D1)
12 to 24 VDC (H7CX-@D)
85% to 110% of rated supply voltage
(12 to 24 VDC: 90% to 110%)
mounted side by side)
(IEC 61010-1)
Operating Procedures
Step1
The H7CX is a Counter that contains more than
one functional counter.
When using the Counter in any modes other than the
default modes listed in Table 2, use the following
chart to enter configuration selection mode and then
refer to Table 1 and set the functions that are suitable
to the application.
Note: can be performed first, followed by .
Step2
Power ON
Run mode
Step1
MODE +
MODE +
1 s min.
1 s min.
U1
U1
Configuration
selection
mode
func
1cnt
MODE
dip
1off
Select the function from Table 1
using the U or D Key.
DIP switch monitor
Operation as a Counter (1-stage Preset Counter, 2-stage Preset Counter, Total and Preset Counter, Batch Counter, Dual Counter, or Twin Counter)
Step2 Step2
1
2
3
4
5
6
7
8
Step3 Step3
Note: Refer to the datasheet (Cat. No. M079) for detailed parameter settings.
Change from RUN Mode to Function Setting Mode.
Set the basic parameters.
(If the desired I/O mode is not listed below or to set all
parameters using the front panel keys, perform , below.)
Item OFF ON
DIP switch settings
Counting speed
Input mode
Output mode
Output time
Minimum reset signal
Input selection
Disabled
Enabled
30 Hz
5 kHz
UP
DOWN
Refer to the table
on the right.
0.5 s
0.05 s
20 ms
1 ms
NPN
PNP
OFF
ON
OFF
ON
OFF
OFF
ON
ON
Output modePin 5Pin 4
Step3
• All pins are factory-set to OFF.
• When setting functions using the
DIP switch, be sure to set pin 1 of
the DIP switch to ON.
N
• DIP switch settings are effective
F
when the power is turned ON
C
again. (Perform DIP switch settings
K-1
while the power is OFF.)
Precautions
Parameters that cannot be set with the DIP switch are set with the operation keys on the front panel.
Set the parameters using the U and D Keys.
The characters displayed in reverse video are the default settings.
When performing settings with operation keys only, set pin1 of the DIP switch to OFF (factory setting).
setting items indicated by will not be displayed. Displays for 4-digit models are given in parentheses.
Display
Parameter name
Input mode*2
Output mode
Output time*3
cnts
Counting speed
iflt
Reset input signal width
dp
Decimal point position
pscl
Prescale value
NPN/PNP input mode
colr
Display color
Absolute value setting/
forecast value setting
Set value upper limit
sl-h
Forecast setting
pl-h
upper limit
Batch set value
bl-h
Function setting mode
upper limit
OUT allocation
otst
change
Key protect level
kypt
Models other than “-@W@/-AU@” Models
Output ON count
on-a
alarm set value
Output ON count
on-c
monitor value
“-@W@/-AU@” Models
Output 1 (OUT1) ON
on1a
count alarm set value
Output 2 (OUT2) ON
on2a
count alarm set value
Output 1 (OUT1) ON
on1c
count monitor value
Output 2 (OUT2) ON
on2c
*1: After reaching the last set value, the U Key will return to the first set value.
*2: When using Dual Counter operation
count monitor value
Dual count calculating
*3:
mode
Set each digit using the individual U and D Keys for the following configuration selection modes.
2-stage Preset Counter
One-shot output 2 time
One-shot output
1 time
Batch Counter
One-shot output 2 time
Twin Counter
One-shot output 2 time
One-shot output 1 time
Set value
up,,,ud-a, ud-b, ud-cK
n, f, c, r, k-1, p, q, a, k-2
d, l, hK*1
0.01 to 0.50 to 99.99
,*1
,*1
------[----], -----.-[---.-],
----.--—[--.--], ---.---[-.---] *1
0.001 to 1.000 to 99.999 [9.999]
npn, pnpK*1
red, grn, org, r-g, g-r, r-o
o-r, g-o, o-gK*1
abs, ofstK*1
1 to 999999 [9999]
1 to 999999 [9999]
1 to 999999 [9999]
,
off, on *1
kp-1, kp-2, kp-3, kp-4, kp-5,
kp-6, kp-7K*1
0 to 9999
---
0 to 9999
0 to 9999
---
---
add,sub
*1,
0.01 to 0.50 to 99.99
hold/0.01 to 99.99
0.01 to 0.50 to 99.99
0.01 to 0.50 to 99.99
0.01 to 0.50 to 99.99
Power ON
,
Run mode
Displayed only when Twin Counter Mode is not selected.
up, : Displayed for output modes other than k-2, d, l, and h only.
h is displayed only for 2-stage models.
k-2, d, l, and h are displayed only when the input mode is ud-a, ud-b, or ud-c.
Displayed only when the output mode is c, r, k-1, p, q, a, or
k-2. Unit: second
---
---
---
---
---
Displayed for models with terminal blocks (except H7CX-A11@)
only.
Displayed only when the configuration selection mode is set to
the 2-stage counter (2cnt).
---
Displayed only when the configuration selection mode is set to the
2-stage counter (2cnt) and there is a forecast value setting.
Displayed only when the configuration selection mode is bcnt.
Displayed only for "-AU@" models.
off: OUT1 = 12, 13, OUT2 = 3, 4, 5 on: OUT1 = 3, 4, 5, OUT2 = 12, 13
The numbers are the terminals numbers.
---
× 1,000
The monitor value is only displayed.
It cannot be set. × 1,000
× 1,000
× 1,000
The monitor value is only displayed.
It cannot be set. × 1,000
The monitor value is only displayed.
It cannot be set. × 1,000
Displayed only when the output mode is k
Displayed only when the output mode is c, r, k-1, p, q, a, or k-2Unit: second
If the output time is 0.00, hold is displayed.
Displayed for output modes other than d, l,and h.
hold cannot be set when the output mode is k
Displayed only when the output mode is c, r, k-1, p, q, aRU k-2. Unit: second
Displayed only when the output mode is c, r, k-1, p, q, or a. Unit: second
Displayed only when the output mode is c, r, k
MODE
MODE
If pin 1 of the DIP switch is set to ON, the
Comments
3 s min.
setting mode
3 s min.
Table 1 Configuration Selection Mode Settings
Display
1cnt
1-stage preset counter
2cnt
2-stage preset counter
tcnt
Total and preset counter
bcnt
Batch counter
dcnt
Dual counter
Twin counter
taco
Tachometer
Note: The modes that can be selected depend on the model. (Refer to Table 2.)
Key-protect switch
ON
OFF
1
2345678
DIP switch
Function
-2
, d, l, or h.
-2
. Unit: second
-1
, p, q, or a. Unit: second
Function
Note: Refer to the datasheet (Cat. No. M079) for detailed parameter settings.
Change from RUN Mode to Function
Setting Mode.
Set the parameters using the U and D Keys.
The characters displayed in reverse video are the default settings.
When performing settings with operation keys only, set pin1 of the DIP switch to OFF (factory setting).
If pin 1 of the DIP switch is set to ON, the setting items indicated by will not be displayed.
Function Setting Mode
*1: After reaching the last set value, the U Key will return to the first set value.
*2: When the tachometer input mode is F2 (2 inputs), set tachometer output modes 1 and 2
using the U Key.
*3: Even if 10 kHz is selected when the tachometer input mode is F2 to F5, the counting
Displays and Settings in Run Mode
1-stage Preset Counter
Present value
1234
Set value
SET
2345
2-stage Preset Counter
Forecast Value Setting
Present value
1234
Set value
SET
2800
MODEMODE
Present value
1234
Forecast set
1
2000
value
Absolute Value Setting
Present value
1234
Set value 1
SET1
2000
MODEMODE
Present value
1234
SET2
Set value 2
2800
Total and Preset Counter
Present value
1234
Set value
SET
2345
MODEMODE
Total count
3456
value
TOTAL
Batch Counter
Present value
18
Set value
SET
24
MODEMODE
Batch Count Value
613
Batch Count
BATCH
1000
Set Value
3) Mounting the Counter side-by-side may reduce the life expectancies of internal components.
4) Use the Counter within the specified ranges for the ambient operating temperature and humidity.
5) Do not use in the following locations:
• Locations subject to sudden or extreme changes in temperature.
• Locations where high humidity may result in condensation.
• Locations with excessive vibration or shock.
• Locations subject to water.
• Locations subject to oil.
6) Do not use the Counter outside of the rated ranges for vibration, shock, water exposure, and oil exposure.
7) Do not use this Counter in dusty environments, in locations where corrosive gasses are present, or in locations subject
to direct sunlight.
8) Install the Counter well away from any sources of static electricity, such as pipes transporting molding materials,
powders, or liquids.
9) Internal elements may be destroyed if a voltage outside the rated voltage range is applied.
10) Separate the Counter from sources of noise, such as devices with input signals from power lines carrying noise,
and wiring for I/O signals.
11) Do not connect more than two crimp terminals to the same terminal.
12) Up to two wires of the same size and type can be inserted into a single terminals.
13) Use the specified wires for wiring. Applicable Wires: AWG 18 to AWG 22, solid or twisted, copper
14) Install a switch or circuit breaker that allows the operator to immediately turn OFF the power, and label it to
clearly indicate its function.
15) When the Counter is operated with no-voltage input (NPN input), approximately 14 V is output from the input
terminals. Use a sensor that contains a diode.
16) Use a switch, relay, or other contact so that the rated power supply voltage will be reached within 0.1 seconds.
If the power supply voltage is not reached quickly enough, the Counter may malfunction or outputs may be
unstable.
17) Use a switch, relay, or other contact to turn the power supply OFF instantaneously. Outputs may malfunction
and memory errors may occur if the power supply voltage is decreased gradually.
18) When changing the set value during operation, because the H7CX uses a constant read-in system, output will
turn ON if the set value is equal to the present value.
19) If the set value and present value are both 0, the output will turn ON for the default setting. The output will turn
OFF during a reset operation.
20) Do not use organic solvents (such as paint thinners or benzine), strong alkali, or strong acids. They will damage
the external finish.
21) Confirm that indications are working normally, including the backlight LED, and LCD. The indicator LEDs, LCD,
and resin parts may deteriorate more quickly depending on the application environment, preventing normal
indications. Periodic inspection and replacement are required.
22) The waterproof packing may deteriorate, shrink, or harden depending on the application environment. Periodic
inspection and replacement are required.
Precautions for Correct Use
1) H7CX models with a 12 to 24-VDC power supply use a transformer-free power supply method in which the power
supply terminals are not isolated from the signal input terminals. If a non-isolating DC power supply is used,
unwanted current paths may occasionally burn or destroy internal components depending on the wiring. Always
check the wiring sufficiently before use.
2) An inrush current of approx. 10 A will flow for a short time when the power supply is turned ON. If the capacity of
the power supply is not sufficient, the Counter may not start. Be sure to use a power supply with sufficient
capacity.
3) Maintain voltage fluctuations in the power supply within the specified operating voltage range.
Ratings (Specifications)
ro gnici on htiw(
)noitasnednoc
.xam m 000,2 edutitlA
)ylno tinu niam( g 031 .xorppA thgieW
Input method
No-voltage input ON impedance: 1 kΩ max. (Leakage current: 12 mA when 0 Ω)
Voltage input High (logic) level: 4.5 to 30 VDC
No-voltage (NPN) input/voltage (PNP) input (switchable)
Control output
ot 21/CAV 42 ta W 7.4/AV 2.7 .xorppA
Contact output 250 VAC, 3 A (resistive load)
CDV 42 ot 21 ta W 7.3 .xorppA ,CDV 42
Solid state output Open collector, 30 VDC max.,100 mA max.
Electrical life of relay 100,000 operations (at an ambient temperature of 23°C)
Mechanical life of relay 10,000,000 operations (at an ambient temperature of 23°C)
External power supply 12 VDC, 100 mA
Degree of protection IEC IP66, UL508 Type 4X*
Individual mounting: Degree of protection on the front panel of the Counter conforms to UL
*
508 Type 4X when all of the following conditions are satisfied:
The Y92S-29 waterproof packing and Y92F-30 mounting adapter are used with the
•
Counter. Use only these parts for replacement.
•
The Counter is mounted on the flat surface of an enclosure that is rated and marked "Type
4X for Indoor Use Only."
30 VDC, 3 A (resistive load)
Residual voltage: 1.5 VDC max.
(Effective value: Approx. 1 VDC)
Leakage current: 0.1 mA max.
egatlov laudiser NO
( woL Ω)
k 001 :ecnadepmi FFO Ω min.
Nomenclature
4
1st digit4th digit
Model
Enabled
10 kHz
on the right.
---
PNP
f5*1
*1 *3
16*1
Twin Counter
Present value 1
1230
Set value 1
2000
SET1
MODEMODE
Present value 2
4560
Set value 2
5000
SET2
7
1
2
8
6
12
13
Default mode
2-stage preset
counter
1-stage preset
counter
*3
Power ON
*1
,
RST
3
9
10
11
(Front view of 6-digit model)
Operation Key
10. Mode Key (Changes modes and setting items)
11. Reset Key
12. Up Keys to (6-digit models: to )
13. Down Keys to
Any mode but
Tachometer
Any mode
1-stage preset or
total preset counter only
Pin 3
OFF
ON
OFF
ON
Pin 5 Pin 6
OFF
ON
OFF
ON
Run mode
Comments
---
---
---
“--.----“ will be displayed when pulse width measurement
is set or when the display unit is set to seconds.
---
---
---
Unit: second
Unit: second
---
---
---
The position of the decimal point for the value after prescaling
will be set according to the decimal point position setting.
Unit: second
---
Displayed only for "-AU@" models.
off: OUT1 = 12, 13, OUT2 = 3, 4, 5
on: OUT1 = 3, 4, 5, OUT2 = 12, 13
The numbers are the terminals numbers.
,
---
---
Displayed only when pulse cycle measurement
is used.
Displayed only if the measurement speed
is 10 kHz when pulse cycle measurement is used.
× 1,000
× 1,000
The monitor value is only displayed.
It cannot be set.
The monitor value is only displayed.
It cannot be set.
---
---
MODE
1
2
3
5
10
11
(Front view of 4-digit model)
8. Set Value Display (Sub-display) (Character height: 6
mm, green)
9. Hold Display (orange)
Displayed only when Tachometer Mode is selected
in the configuration selection mode.
Table 2 Default Modes and Selectable Functions
H7CX-A4W
H7CX-AW@
H7CX-AU@
Other models
Operation as a Tachometer
Set the basic parameters.
To set all parameters using the front panel keys, perform , below.
Note: The location of the DIP switch is shown on the left.
Also, read the precautions provided on the left.
Item
DIP switch settings
1
Counting speed
2
3
Tachometer output
mode
4
5
Average processing
6
7
---
8
Input selection
Parameters that cannot be set with the DIP switch are set with the operation
keys on the front panel.
Parameter name
Display
Tachometer input mode
Tachometer output mode*2
Counting speed
cnts
Decimal point position
dp
Prescale value
pscl
Averaging method
avgt
Averaging processing
avgn
Auto-zero time
auto0
Startup time
NPN/PNP input mode
Display color
colr
Peak/bottom hold
dhld
enabled
Output hysteresis
hys
Output OFF delay
offd
Set value upper limit
sl-h
OUT allocation change
otst
Key protect level
kypt
Pulse cycle measurement/
pulse width measurement
Display unit
unit
Measurement cycle
intv
Output 1 (OUT1) ON
on1a
count alarm set value
Output 2 (OUT2) ON
on2a
count alarm set value
Output 1 (OUT1) ON
on1c
count alarm monitor value
Output 2 (OUT2) ON
on2c
count alarm monitor value
Tachometer output
mode 1
Tachometer output
mode 2
speed will be 5 kHz.
Dual Counter
Dual count value
9876
Dual count set value
SET
9945
MODE
CP1 present value
3524
CP2 present value
1 2
6352
OFF ON
Disabled
30 Hz
Refer to the table
on the right.
Refer to the table
---
NPN
Set value
,f2,f3,f4,
f1
,
area,hihi,lolo*1
hilo
,
------, -----.-,
----.--, ---.---, --.----
to 1.000 to 99.999
0.001
,
*1
off
,2,4,8,
to 999.9
0.1
0.0
to 99.9
npn
,
pnp*1
,
grn,org,r-g,g-r
red
r-o,o-r,g-o,o-g*1
off
,
on*1
WR99999
0
0.00 to 19.99
1
to 999999
off, on*1
,
kp-2,kp-3,kp-4
kp-1
kp-5,kp-6,kp-7*1
,
wide*1
phas
,
s*1
,
cont
to 9999
0
to
9999
0
---
---
hi, lo
*1
hi, lo
*1
MODE
.xam V 3 :
1st digit6th digit
1 4
1 4
Selectable mode
Step3
Pin 4
Upper/lower limit output
OFF
OFF
Upper limit output
ON
Lower limit output
ON
Average processing
OFF
OFF
ON
ON
MODE
MODE
× 1,000
× 1,000
Tachometer
Measurement value
2280.00
(Not displayed when the input
mode is f2.)
MODE
Measurement value
2280.00
SET1
2300.00
Comparison value 1
MODE
Measurement value
2280.00
SET 2
2000.00
Comparison value 2
7
4
5
8
6
12
Tachometer
output mode
Area output
OFF
2 times
4 times
8 times
3 s min.
Function
setting mode
3 s min.
4) To allow for the startup time of peripheral devices (e.g., sensors), start Counter timing operation 200 ms to
290 ms after turning ON the power. The input signal will not be accepted before 200 to 290 ms has elapsed.
5) The input signal will not be accepted after 5 to 1005 ms has elapsed from when the power supply is turned
OFF.
6) Inrush current generated by turning ON or OFF the power supply may deteriorate contacts on the power
supply circuit. Turn ON or OFF to a device with the rated current of more than 10 A.
7) The capacity of the external power supply is 100 mA at 12 V. When
using a 24 VAC/12 to 24 VDC power supply, reduce the load with
the power supply voltage, as shown in the diagram (DC power
supplies only) on the right.
8) If the prescale value setting is incorrect, a counting error will occur.
Check that the settings are correct before using this function.
9) Make sure that all settings are appropriate for the application.
Unexpected operation resulting in property damage or accidents may occur if the settings are not
appropriate.
10) Do not leave the Counter for long periods at a high temperature with output current in the ON state. Doing
so may result in the premature deterioration of internal components (e.g., electrolytic capacitors).
11) EEPROM is used as memory when the power is interrupted. The write life of the EEPROM is 100,000
writes. The EEPROM is written when the power is turned OFF or when switching from function setting
mode or configuration selection mode to run mode.
12) Dispose of the product according to local ordinances as they apply.
13) Attach the front panel when using the Counter. The latches in the middle of each of four sides secure the
front panel to the main body. To remove the panel, widen the four latches and pull the panel toward you.
To mount the panel, fit all four latches correctly into the slots on the main body.
Conformance to EN/IEC Standards
• When conforming to EMC standards, refer to the information provided in this Instruction Manual for
cable selection and other conditions.
• This is a class A product. In residential areas it may cause radio interference, in which case the user
may be required to take adequate measures to reduce interference.
• Basic insulation is provided between power supply and input terminals, between power supply and
output terminals, and between input and output terminals. (No insulation is provided between the
power supply and input terminals for the H7CX-A@D.)
• Basic insulation is provided between power supply and output terminals, and between input and
output terminals. When double insulation or reinforced insulation is required, apply double insulation
or reinforced insulation as defined in IEC 60664 that is suitable for the maximum operating voltage
with clearances or solid insulation.
• Connect the input and output terminals to devices that do not have any exposed charged parts.
Precautions for Compliance with UL Standards and CSA Standards
Notice to Users of the H7CX in the USA and Canada
Please use the following installation information instead of the general information in the instruction
manuals in order to use the product under certified conditions of UL and CSA when the product is
installed in the USA or Canada. These conditions are required by NFPA 70, National Electrical Code in
the USA and the Canadian Electrical Code, Part I in Canada and may vary from information given in
the product manuals or safety precautions.
• Installation in a Panel
H7CX is normally installed on a flat surface in an operation panel. Use a Type 1 Enclosure for the
operation panel.
• Use an isolated source for power input for H7CX-@D and H7CX-@D1.
Use the isolated source for Inputs and for Solid State Output.
• Environment
Surrounding Air Temperature: −10 to 40°C
• Power supply: The inputs are non-isolated. (Applicable to H7CX-@D only)
The same power supply as the main power source should be used for that for input.
k 7.4 .xorppa :ecnatsiser tupnI( CDV 2 ot 0 :level )cigol
• Accessories (Order Separately)
Track Mounting/Front Connecting Socket
Flush Mounting Adapter
Waterproof Packing
Front Panel (4 digits/6 digits)
Wire properly after checking the specifications of the power supply voltage.
Do not connect unused terminals.
Terminal Arrangement
H7CX-A-N/-A4-N 1-stage Contact Output
Reset
0 V
678910
(−)
Sensor
(+)
12 VDC
11
External
power supply
12345
H7CX-AS-N/-A4S-N 1-stage Solid State
Output
Reset
1 6
H7CX-AW-N/-A4W-N/-AWD1-N
-AU-N/-AUD1-N
2-stage Contact
Output
H7CX-AWSD-N/-A4WSD-N 2-stage
Solid State Output
H7CX-A11S-N/-A114S-N/-A11SD1-N
Solid State Output
Input Connections
No-voltage Inputs (NPN Inputs)
Voltage Inputs (PNP Inputs)
0 V
678910
(−)
Sensor
(+)
12 VDC
11
External
power supply
12345
CP2
Reset 1
0 V
678910
(−)
Sensor
(+)
12 VDC
11 12 13
External
power supply
12345
OUT2
(+)(−)
Reset 1
0 V
678910
Terminals 1
and 6 are
connected
internally.
(−)
Sensor
(+)
External
power supply
Open Collector
PLC or
sensor
Note: Operate with transistor ON
No-contact Input (NPN Transistor)
Sensor
Note: Operate with transistor OFF
12345
Reset
CP1
CP2
Total reset
0 V
12 VDC
0 V
0 V
4
3
Reset
Reset
(+)(−)
5
2
CP
CP
12 13
6
Key-protect Switch Settings
When the key-protect switch is ON,
individual key operations can be
disabled to prevent setting errors
according to the key prot ect leve ls
(KP-1 to KP-7) shown in the
following table.
* Key protect levels are set in
function setting mode.
Level
*Mode change
KP-1 (default setting)
KP-2
KP-3
KP-4
KP-5
KP-6
KP-7
* Changing mode to configuration selection mode or function setting mode.
Invalid
Invalid
Invalid
Invalid
Invalid
Invalid
Invalid
Self-diagnostic Functions
The following displays will appear if an error occurs.
Main display
Sub-display
No change
No change
8
No change
Not lit
Not lit
Present value
underflow *
Present value
overflow *
CPU error
Memory error (RAM)
Memory error (EEPROM) *
Output Counter Overflow
-----
(----)
*1*5
fffff
(
ffff)*1*5
e1
e2
e2
e3 *
*1. Displays for 4-digit models are given in parentheses.
*2. This includes times when the life of the EEPROM has expired.
*3. This occurs if the present value or total count value falls below –99999 (–999 for 4-digit models).
*4. This occurs in the following conditions if the present value (i.e., measurement value) exceeds 999999 (9999 for 4-digit models).
• For Output Modes K-2, D, L, or H
• Dual counter or tachometer operation is used.
*5. Display flashes.(1-second cycles)
*6. This does not apply when tachometer operation is used.
*7. This is displayed if the alarm value setting for either of the two outputs is exceeded if a model with two outputs is used.
The total ON count will not be cleared by using the Reset Key.
*8. The normal display and e3 will appear alternately.
When the Reset Key is pressed, e3 will not be displayed even if the alarm set value is exceeded. (Monitoring is possible,
however, because the Counter will continue without the output ON count being cleared.)
OMRON EUROPE B.V.
Wegalaan 67-69-2132 JD Hoofddorp, The Netherlands
Tel: (31)2356-81-300/Fax: (31)2356-81-388
OMRON ELECTRONICS LLC (U.S.A.)
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
OMRON ASIA PACIFIC PTE. LTD. (SINGAPORE)
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
11-pin
11-pin, finger-safe type
8-pin
8-pin, finger-safe type
---
---
Light gray (Munsell 5Y7/1)
White
Black
H7CX-AD-N/-A4D-N 1-stage Contact
CP1
CP2
OUT
CP1
CP2
Output
Total reset
H7CX-ASD-N/-A4SD-N 1-stage Solid State
Output
Total reset
*
OUT
H7CX-AWS-N/-AWSD1-N/-AUSD1-N
2-stage
CP1
Reset 2
CP1
CP2
Solid State Output
1
*
OUT1
1: “-AU@” Models
*
*
12 13
H7CX-A11-N/-A114-N/-A11D1-N/-A114D1-N
1-stage Contact Output
Reset 2
OUT1
*
OUT2
:
1-stage
*
Internal circuit
7
8
9
10
111
OUT
(+)(−)
Sensor
No-contact Input (PNP Transistor)
Sensor
Description
4
NPN Output
Power for load
*
When an inductive load is
connected to the H7CX.
Voltage Output Contact Input
0 V
Reset
Note: Operate with transistor ON
0 V
Note: Operate with transistor ON
OFF (disable)
(Factory setting)
Key protect indicator
Display switch in the run mode
Valid
Valid
Valid
Valid
Invalid
Invalid
Invalid
Output status
No change
3
No change
OFF
OFF
2
OFF
No change
0 V
678910
12345
(−)
0 V
678910
12345
(−)
(−)
Sensor
(+)
12 VDC
External
power supply
Reset
CP1
CP2
Total reset
(−)
Sensor
(+)
External
power supply
Load
+
CP
Reset
CP
ON (enable)
Correction method
Either press the Reset
Key or turn ON reset input. *6
Either press the Reset
Key or reset the power supply.*6
Turn ON the power again.
Reset Key
Turn ON the power again.
Reset Key
Reset Key *7
100
Load
current
(mA)
20
0
10.8 15
Power supply voltage (VDC)
P2CF-11
P2CF-11-E
P2CF-08
P2CF-08-E
Y92F-30
Y92S-29
Y92P-CXC4G/Y92P-CXC6G
Y92P-CXC4S/Y92P-CXC6S
Y92P-CXC4B/Y92P-CXC6B
CP1
CP2
Reset
Total reset
Terminals 1
and 6 are
connected
internally.
OUT
(+)
CP1
CP2
Reset
Total reset
Terminals 1
and 6 are
connected
internally.
*
OUT
(+)
CP1
CP2
Reset 1
0 V
678910
11 12 13
12345
OUT2
(+)(−)
6
5
7
4
8
0 V
3
9
2
10
1
11
12 VDC
(+)(−)
PNP Output
Load
+
Power for load
Counter
+
Power for load
0 V
Reset
Note: Operate with relay ON
Contact Input
0 V
Reset
Note: Operate with relay ON
Up/Down Key
Reset Key
Valid
Invalid
Valid
Invalid
Invalid
Valid
Invalid
Set value after reset
No change
No change
No change
No change
Factory setting.
No change
Reset 2
OUT1
*
Internal circuit
OUT
Inductive
load
CP
CP
Valid
Valid
Invalid
Invalid
Invalid
Valid
Valid
安全上のご注意
●警告表示の意味
形 H7CX-A□-N
電子カウンタ
JPN
オムロン製品をお買い上げいただきありがとうござ い ま す 。
この製品を安 全に正しく使用していただくために 、お使いに
なる前にこの取扱説明書をお読みになり、十分にご理解くだ
さい 。お読みになったあとも、いつも手元に置いてご使用く
ださい 。
取扱説明書
軽度の感電、発火、機器の故障が稀に起こる恐れがあり
ます 。製品の中に金属、導線または、取り付け加工中の
切粉などが入らないようにしてください 。
爆発により稀に軽度の傷害の恐れがあります。引火性、
爆発性ガスのある所では使用しないでください 。
発火が稀に起こる恐れがあります。端子ネジは下記の規
正しい 取 扱 いをしなければ 、この危 険 のために、時に軽傷・中程
注意
度の傷害をおったり、あるいは物的損害を受ける恐れがあります 。
注意
定トルクで締めてください 。
©All Rights Reserved
詳細は、最新版のカタログ(SGTB-014㧕を参照してください 。
ご使用に際してのご承諾事項
下記用途に使用される場合、当社営業担当者までご相談のうえ仕様書などによりご確認いただくとともに 、
定格・性能に対し余裕を持った使い方や、万一故障があっても危険を最小にする安全回路などの安全対
策を講じてください 。
a) 屋外の用途、潜在的な化学的汚染あるいは電気的妨害を被る用途またはカタログ、取
b) 原子力制御設備、焼却設備、鉄道・航空・車両設備、医用機械、娯楽機械、安全装置、
c) 人命や財産に危険が及びうるシス テ ム・機械・装置
d)
e) その他 、上記 a)〜 d)に準ずる、高 度な安全 性が 必要とされる 用 途
*上記は適合用途の条件の一 部です。当社のベスト、総 合カタログ、データシート等最 新
扱説明書等に記載のない条件や環境での使用
および行政機関や個別業界の規制に従う設備
ガス、水道、電気の供給システムや24時間連続運転システムなど高い信頼性が必要な設備
版のカタログ、マニュアルに記載の保証・免責事項の内容をよく読 んで ご 使 用ください 。
取付およびパネル加工寸法図
●取付寸法図(単位:mm)
フロント部分の外形寸法は全ての形式
に共通です。
48
48
〈表面取付〉
形H7CX
-A11□
103.2
*
形P2CF-11(-E)(別売)
表面接続ソケット
*
DIN レールの種類により異なります。
(参考値)
〈埋込取付〉
形H7CX-A11□-N
形Y92S-29(別売)
防水パッキン
(51)
7.5 89.9
形H7CX-A-N/-AS-N/-AW-N/-AWS-N/-AWD1-N/
-AWSD1-N/-A4-N/-A4S-N/-A4W-N
形Y92S-29(付属)
防水パッキン
(51)
形H7CX-AD-N/-ASD-N/-AWSD-N/-A4D-N/
100.9
-A4SD-N/-A4WSD-N
形Y92S-29(付属)
防水パッキン
(51)
7.5 57.5
パネル
パネル
パネル
形Y92F-30(別売)
埋込み取付用アダプタ
形Y92F-30(付属)
埋込み
取付用アダプタ
76.57.5
形Y92F-30(付属)
埋込み取付用アダプタ
H7CX本体端子 : 6.55〜7.97 Lb-In(0.74〜 0.90 N・m)
P2CFソケット端子: 4.4 Lb-In(0.5 N・m)
感電により軽度の傷害が稀に起こる恐れがあります。通
電中は端子に触らないでください 。また 、配線後、必ず端
子カバーを取り付けてください 。
出力リレーの寿命は、開閉容量、開閉条件により大きく異
なるので必ず実使用条件を考慮し、定格負荷、電気的寿
命回数内でご使用ください 。寿命を超えた状態で使用する
と接点溶着や焼損の恐れがあります。また 、負荷電 流は必
ず定格以下でご使用いただき、ヒータ等を使 用 する場 合
は、必ず負荷回路にサーモ・スイッチをご 使 用ください 。
軽度の感電、発火、機器の故障が稀に起こる恐れがあり
ます 。分解、改造、修理したり、内部に触らないでください 。
●パネル加工寸法図(単位:mm)
標準パネルカットは下図のとおりです。
(DIN43700 準拠)
アダプタのフック側方向への取付間隔は、
作業性を考慮すると15mm 以上(パネル
カット間 隔 60mm 以上)あけることを推奨し
ます 。
+0.6
ー0
□45
60以上
注1. 取付パネルの板厚は1〜5mmが適
当です。
注2. アダプタの取付により密着取付が
可能です。(ただしフックのない方向
のみ)
58
15以上
n個密着取付
A
1
A (48n 2.5)
注3. 密着取り付け時は、耐水性が失われます。
0
梱包内容
● 製品本体
● 取扱説明書(本紙)
● 取付アダプタ、防水パッキン、
端子カバー(形H7CX-A11□を除く)
● ディップスイッチ 用 ラ ベ ル
(形H7CX-AW□のみ)
電源電圧 AC100 〜 240V50/60Hz
AC24V50/60Hz / DC12 〜 24V
DC12〜 24V
許容電圧変動範囲
消費電力 約9.4VA(AC100〜240V)
約7.2VA/4.7W(AC24V/DC12
約3.7W(DC12
使用温度範囲
(ただし、氷結、結露しないこと)
保存温 度範 囲 −25 〜+7 0℃(ただし、氷結、結露しないこと)
使用周囲湿度 25 〜 85%
高度 2,000m以下
推奨ヒューズ T2A、AC250V、タイムラグヒューズ 、低遮断容量
質量 約130g(本体のみ)
設置環境 過電圧カテゴリⅡ、汚染度2(IEC61010-1による)
48
入力方式
無電圧入力 短絡時インピーダンス: 1kΩ以 下(0Ω時流出電流12mA)、
電圧入力
無電圧(NPN)入力/電圧(PNP)入力(切替)
●表示部
①キープロテクト表示
②制御出力表示(橙色)
OUT(1 段設定タイプ)
OUT (2 段設定タイプ)
③リセット表示(橙色)
(リセット(1)入 力 またはリセ ットキー O N 時 に 点 灯 )
機種選択モードでタコメータ以外の時のみ表示
④トータルカウント表示
(トータルカウント値表示時に点灯)
⑤バッチ表示
(バッチカウント値表示時に点灯)
⑥設定値 1、2 表示の段階表示
⑦カウント値(第 1 表示)
(文字高 12mm(6 桁タイプ:10mm)、赤色*)
*端子台タイプ(形 H7CX-A11□以外)は、
⑧設定値(第 2 表示)(文字高 6mm、緑色)
⑨ホールド表示(橙色)
機種選択モードでタコメータの時のみ表示
定格電源電圧の85 〜 110%(DC12 〜 24Vは90 〜 110%)
−10 〜+55 ℃(密着取付時:−10 〜+5 0℃)
短絡時残留電圧:3V以下、開放時インピーダンス:100kΩ以上
Hレベル:DC4.5〜30V、Lレベル:DC0〜2V(入力抵抗約4.7kΩ)
(橙色)
1 2
赤色/緑色/橙色切替
操作方法
Step1
本機は複数の計数機能を有するカウンタです。
表 2に示す工場出荷モード以外で使用される方は、
下記のチャートにて機種選択モードに入り、
表 1を参照しながらアプリケーションにあった機 種
を設定してください 。
Step2
注) を先に設定し、 を後から設定
することも可能です。
Step1
電源ON
運転モード
MODE +
1秒以上押す
MODE +
1秒以上押す
機種選択モード
U1
func
U1
1cnt
MODE
dip
1off
U(D キー )で表 1 の
中から機種選択します。
ディップスイッチ
モニタ
表 1 機種選択モード一 覧
表示
1cnt
2cnt
tcnt
bcnt
dcnt
twn
taco
※形式により選択できない機種があります。(表2参照)
機種
1段プリセットカウンタ
2段プリセットカウンタ
トータルプリセットカウンタ
バッチカウンタ
デュアルカウンタ
ツインカウンタ
タコメータ
カウンタ(1段プリセット、2段プリセット、トータルプリセット、バッチ、デュアル、ツイン)としてご使用の場合
Step2 Step2
1
2
3
4
5
6
7
8
Step3
※各パラメータの設定値の詳細は、カタログを参照してください。
●運転モードを機能設定モードに切り替えます。
●各パラメータを U(D)キーで設定します。
反転文字は工場出荷時の設定です。
前面キーのみで設定する場合はディップスイッチ 1 を「OFF」[ 出荷時設定 ] にしてください。
ディップスイッチ 1 が「ON」(有効)の場合は、の設定項目は表示されません。
4 桁タイプは〔 〕内の表示となります。
※1:設定値が最後尾に来たとき、Uキーで再び先頭に戻ります。
※2:デュアルカウンタの場合
※3:機種選択モードが下記の場合、
基本的なパラメータの設定を行います。
(下表にご希望の入力/出力モードがない場合、またはすべての設定を前面キー
で行いたい場合は、 の内容に従って設定を行ってください。)
項目 OFF ON
ディップスイッチ設定
計数速度
入力モード
出力モード
出力時間
最小リセット時間
入力モード切替
無効
30Hz
UP
右記参照
0.5s
20ms
NPN
Step3
有効
5kHz
DOWN
0.05s
1ms
PNP
OFF
OFF
出力モードスイッチ5スイッチ4
OFF
ON
OFF
ON
ON
ON
K-1
ディップスイッチで設定できない機能を、前面キーにて設定します。
パラメータ名
画面
入力モード※2
cntm
出力モード
outm
出力時間※3
otim
計数速度
cnts
最小リセット時間
iflt
小数点位置
dp
プリスケール 値
pscl
NPN/PNP 入力
imod
モード切替
表示色切替
colr
絶対値設定
setm
機能設定モ ー ド
/ 予報値設定
設定リミット上限
sl-h
予報設定リミット上限
pl-h
バッチカウント値設定
bl-h
リミット上限
キープロテクトレ ベ ル
kypt
●-□W□タイプ以外の場合
出力 ON 回数警報
on-a
設定値
出力 ON 回数
on-c
モニタ値
●-□W□タイプの場合
出力 1(OUT1)ON
on1a
回数警報設定値
出力 2(OUT2)ON
on2a
回数警報設定値
出力 1(OUT1)ON
on1c
回数モニタ値
出力 2(OUT2)ON
on2c
回数モニタ値
デュアルカウント値
calm
算出モード
●2 段プリセットカウンタの 場 合
OUT2 出力時間
otm2
OUT1 出力時間
otm1
●バッチカウンタの場合
otm2
OUT2 出力時間
●ツインカウンタの 場 合
otm2
OUT2 出力時間
OUT1 出力時間
otm1
設定値
up,down,ud-a,ud-b,ud-cK※1
n,f,c,r,k-1,p,q,a,k-2,d,l,
hK※1
0.01 〜 0.50 〜 99.99
30hz,5khzK※1
20ms,1msK※1
------〔----〕,-----.-〔---.-〕,
----.--—〔--.--〕,---.---〔-.---〕※1
0.001 〜 1.000 〜 99.999〔9.999〕
npn,pnpK※1
red,grn,org,r-g,g-r,r-o,o-r,
g-o,
o-gK※1
abs,ofstK※1
1 〜 999999〔9999〕
1 〜 999999〔9999〕
1 〜 999999〔9999〕
kp-1,kp-2,kp-3,kp-4,kp-5,kp-6,
kp-7K※1
0 〜 9999
−
0 〜 9999
0 〜 9999
−
−
add,sub
K※1
U(D)キーで対応する各桁の数値を設定します。
0.01 〜 0.50 〜 99.99
hold/0.01 〜 99.99
0.01 〜 0.50 〜 99.99
0.01 〜 0.50 〜 99.99
0.01 〜 0.50 〜 99.99
注意事項
・出荷時は、すべて OFF に設定して
います。
・ディップスイッチにて機能設定す
る場合はスイッチ 1(ディップスイ
N
ッチ設定)を必ず「ON」(有効)にし
F
てください。
C
・ディップスイッチの設定は電源投
入時に変更されます。
(ディップスイッチは取付・通電前
に設定ください。)
電源投入
運転モード
特記事項
ツインカウンタ以外の時のみ表示
up、down は、出力モードが k-2、d、l、h 以外の時のみ表示
h は、2 段機種タイプの時のみ表示。
k-2,d,
l,
h は、入力
出力モードが c、r、k-1、p、q、a、k-2 の時のみ表示。単位:秒
−
−
−
−
−
MODE
MODE
モードが ud-a,ud-b,ud-c の時のみ表示。
端子台タイプ(形 H7CX-A11□以外)の時のみ表示
機種選択モードが 2 段機種タイプで 2cnt 時のみ表示
−
機種選択モードが 2 段機種タイプで 2cnt、予報値設定の時のみ表示
機種選択モードが bcnt の時のみ表示
ー
×1000
モニタ値の表示のみ。設定ではありません 。
×1000
×1000
×1000
モニタ値の表示のみ。設定ではありません 。
×1000
モニタ値の表示のみ。設定ではありません 。
×1000
出力モードが k-2、d、l、h の時のみ表示
出力モードが c、r、k-1、p、q、a、k-2 の時のみ表示。単位:秒
出力時間 0.00 の時、表示は hold になります
出力モードが d、l、h 以外の時のみ表示
出力モードが
k
-2 の時、hold は設 定できません。
出力モードが c、r、k-1、p、q、a、k-2 の時のみ表示。単位:秒
出力モードが 、c、r、k-1、p、q、a の時のみ表示。単位:秒
出力モードが 、c、r、k-1、p、q、a の時のみ表示。単位:秒
3秒以上
機能設定モード
3秒以上
キープロテクトスイッチ
ON
OFF
1
2345678
ディップスイッチ
。単位:秒
Step3
※各パラメータの設定値の詳細は、カタログを参照してください。
●運転モードを機能設定モードに切り替えます。
●各パラメータを U キーで設定します。
機能設定モ ー ド
※1:設定値が最後尾に来たとき、Uキーで再び先頭に戻ります。
※2:タコメータ入力モードが F2(2 入力)の場合、U キーでタコメータ出力モード 1、2 を設定します。
※3:タコメータ入力モードが F2 〜 F5 の場合、
運転モードでの表示/設定
1段プリセットカウンタ 2段プリセットカウンタ
カウント値
1234
SET
2345
設定値
1234
SET
1234
SET1
2800
2000
カウント値
設定値
MODEMODE
カウント値
予報設定値
絶対値設定の場合予報値設定の場合
1234
SET1
1234
SET2
2000
2800
カウント値
設定値1
MODEMODE
カウント値
設定値2
トータルプリセットカウンタ
カウント値
1234
2345
3456
MODEMODE
設定値
トータル
カウント値
SET
TOTAL
バッチカウンタ デュアルカウンタ ツインカウンタ タコメータ
カウント値
18
設定値
SET
24
MODEMODE
バッチカウント値
613
バッチカウント
BATCH
1000
設定値
1)パネルへの 取り付けの際は2ヵ所 の ねじを交互に バランスを取りながらしっかり締め てください 。バラ
ンスがとれていない場合、パネルの 内部 に水が 浸 入する可能 性があります。
2)保存は、記載された定格範囲内としてくださ い 。また 、−10℃以下で保 存後 、使用する場合は、常温
に3時間以上放置してから通電してください 。
3)密着取り付けをすると内部部品の寿命が短くなる 恐れ があります。
4)使用周囲温度や使用周囲湿度については、記載された定格範囲内でご使用ください 。
5)下記環境下での使用は避けてください 。
・ 温度変化の激しいところ。
・ 湿度が高く結露が生じる恐れのあるところ
・振動、衝撃の影響が大きいところ
・水がかかるところ
・被油のあるところ
6)
粉塵の多い場所、腐食ガスの発生する場所、直射日光の当たる場所での使用は避けてください 。
7)多量の静電気が発生する環境(成形材料、粉、流体材料をパイプ搬送する場合など)でご使用の場
合は静電気発生源を製品本体より離してください 。
8)定格以外の電圧を印加しますと、内部素子が破壊する恐れがあります。
9)端子の極 性は、誤配線のないようにしてください 。
10)ノイズ発生源、ノイズがのった強電線から入力信号源の機器、入力信 号線の配線、および製品本体
を離してください 。
11)圧着端子を使用する場合は1つの端子に2個までとしてください 。
配線は1端子あたり2本までは締め付けられますが、その場合、2本は同じ線種で使用してください。
12)
13)配線に使用する適用電線は記載された適切なものを使用してください。
適用電線 AWG18 〜 22 単線またはより線 銅
14)
作業者がすぐ電源をOFF できるよう、スイッチまたは サーキットブレーカを設置し、適切に表示してください 。
15)無電圧入力(NPN入力)で使用される場合、入力端子より約14Vが出力されます。ダイオードの 入っ
たセンサをご使 用ください。
電源電圧は0.1秒以内に定格電圧に達するように スイッチ、リレーなどの接 点を介して一 気 に印 加して
16)
ください 。徐々に電圧を印加しますと、電源リセットしなかったり出力の誤動作が発生することがあります 。
17)電源遮断時はスイッチ 、リレーなどの接 点を介して一 気に 行ってください 。徐々に電圧を低下させます
と、出力の誤動作やメモリ異常が発生することがあります 。
18)常時読込方式を採用しているため、動作中に設定値を変更する場合、“設定値=カウント値”となると
出力がONしますの でご 注 意ください 。
19)“設定値=カウント値=0”では出力 が ONします (工場出荷状態)。ただし、リセット操作 中の 出力はOFF
します 。
20)本体の外装は有機溶剤(シンナー・ ベンジンなど)強アルカリ性、強酸物質に侵されますので使用し
ないでください 。
21)表示(バックライトLED、LCD)が正常に動作していることをご確認ください 。ご使用環境によっては、
LED,LCD,樹脂部品の劣化を早め、表示不良になることがありますので 、定期的な点 検および交
換をお願 いします。
22)防水パッキンはご使用環境によっては、劣 化 ・ 収 縮および 硬 化 するため定 期 的な 点 検 および交 換
をお願 いします。
定格(仕様)
〜
〜
24V)
24V)
制御出力
リレー出力
トランジスタ出力 オープンコレクタ DC30Vmax、100mAmax
残留電圧 DC1.5V以下
(実力約DC1V)
漏洩電流 0.1mA以下
リレーの電気的寿命 10万回(周囲温度条件:23℃)
リレーの機械的寿命 1000万回(周囲温度条件:23℃)
外部供給電源 DC12V100mA
保護構造 IEC規格IP66、UL508Type4X*
*単品取付け:フロント部の保護構造は、以 下の条件が全て満たされた場
・防水パッキン形Y92S-29と取付けアダプタ形Y92F-30をカウンタと
・カウンタは、Type4XforIndoorUseOnlyの認定の表示がある制
AC250V3A(抵抗負荷)DC30V3A(抵抗負荷)
合に、UL508Type4Xに適合します。
共に使用する。取り替 え時も、これらの 部 品を使 用 する 。
御ボックスの 平 面に 取り付 ける。
フロント部の名称
安全上の要点
4
1
2
3
5
10
11
(4桁タイプ正面図)
●操作キー部
⑩モードキー
(モードの移行、設定項目の切替を行います)
⑪リセットキー
⑫アップキー (6 桁タイプ: )
⑬ダウンキー
1 4
1 4
7
1
2
8
6
12
13
1桁目4桁目
〜
〜
表 2 出荷時の機種設定及び選択可能機種一覧
形式
H7CX-A4W
H7CX-AW□
上記以外
工場出荷モード
2段プリセット
カウンタ
1段プリセット
カウンタ
3
9
10
11
1 6
〜
RST
(6桁タイプ正面図)
選択可能範囲
タコメータ以 外
全て
1段プリセット、
トータルプリセットのみ
1桁目6桁目
タコメータとしてご使用の場合
基本的なパラメータの 設 定を行います 。
(すべての設定を前面キーで行いたい場合は、 の内容に従って
設定を行ってください 。)
※注意事項、ディップスイッチ の 位 置 は
左記を参照くださ い 。
項目
ディップスイッチ 設 定
1
計数速度
2
3
タコメータ出 力モ ード
4
5
平均回数
6
7
未使用
8
入力モード゙ 切替
OFF ON
無効
30Hz
右記参照
右記参照
ー
NPNーPNP
ディップスイッチで設定できない機能を、前面キーにて設定します。
反転文字は工場出荷時の設定です。
前面キーのみで設定する場合はディップスイッチ 1 を「OFF」[ 出荷時設定 ] にしてください。
ディップスイッチ 1 が「ON」(有効)の場合は、の設定項目は表示されません。
パラメータ名
画面
タコメータ入 力 モード
tinm
タコメータ出 力 モード※2
totm
計数速度
cnts
小数点位置
dp
プリスケール 値
pscl
平均方法
avgt
平均回数
avgn
オートゼ ロ 時 間
auto0
起動補償タイマ
stmr
NPN/PNP
imod
入力モード切替
表示色切替
colr
ピーク / ボトム
dhld
ホールド有効
出力ヒステリシス
hys
出力オフディレイ
offd
設定リミット上限
sl-h
キープロテクトレ ベ ル
kypt
パルス周期計 測 /
calm
パルス幅計測
表示単位
unit
計測間隔
intv
出力 1(OUT1)ON
on1a
回数警報設定値
出力 2(OUT2)ON
on2a
回数警報設定値
出力 1(OUT1)
on1c
ON 回数モニタ値
出力 2(OUT2)
on2c
ON 回数モニタ値
to1m
タコメータ出力
モード1
to2m
タコメータ出力
モード2
9876
SET
3524
1 2
9945
6352
MODE
設定値
f1,f2,f3,f4,f5※1
hilo,area,hihi
30hz,10khz※1、
------,-----.-,
----.--,---.---,--.----※
0.001 〜 1.000 〜 99.999
smp,mv※1
off,2,4,8,16※1
0.1 〜 999.9
0.0 〜 99.9
npn,pnp※1
red,grn,org,r-g,g-r,
r-o,o-r,g-o,o-g※1
off,on※1
0 〜 99999
0.00 〜 19.99
1 〜 999999
kp-1,kp-2,kp-3,kp-4,
kp-5,kp-6,kp-7※1
phas,wide※1
hz,s※1
200ms,cont
0 〜 9999
0 〜 9999
−
−
hi,lo※1
hi,lo※1
デュアルカウント値
デュアルカウント設定値
CP1カウント値
CP2カウント値
MODE
Step3
スイッチ4
OFF
OFF
ON
ON
OFF
OFF
ON
ON
タコメータ出 力モ ード
上下限出力
範囲出力
上限出力
下限出力
3秒以上
MODE
MODE
3秒以上
有効
10kHz※3
,lolo※1
※3
スイッチ3
OFF
ON
OFF
ON
スイッチ5 スイッチ6 平均回数
OFF
ON
OFF
ON
電源投入
運転モード
特記事項
−
−
−
パルス幅計測時、または表示単位
1
=s時 の み「--.----」表示可能
−
−
−
単位:秒
単位:秒
−
−
−
プリスケール後の値を対象とし、小数
点位置は小数点位置設定にしたがう。
単位:秒
−
−
−
パルス周期計測時のみ表示
パルス周期計 測時で、計数速度
=10kHz の時のみ表示
×1000
×1000
モニタ値の表示のみ。
設定ではありませ ん 。×1000
モニタ値の表示のみ。
設定ではありませ ん 。×1000
ー
ー
10kHzを選択すると5kHz の計数速度になります 。
計測値(入力モードが
2280.00
2280.00
SET1
2300.00
2280.00
SET 2
2000.00
f2の場合は非表示)
MODE
計測値
比較値1
MODE
計測値
比較値2
1230
2000
SET1
4560
5000
SET2
MODEMODE
カウント値1
設定値1
カウント値2
設定値2
MODE
7
4
5
8
6
12
OFF
2回
4回
8回
機能設定モード
1)形H7CXシリーズ の DC12-24V電源タイプは電源端子と信号入力端子間が絶縁されて
いない電 源トランスレス 方 式 となってい ます 。非絶縁タイプのDC電源を使用する場合
は、配線によっては回り込みで、稀に内部部品の焼損(破壊)の恐れがあります 。
に配線を十分ご確認ください 。
前
2)電源投入時に短時間ですが突入電流が流れ(約10A)、電源の容量によっては起動しな
いことがありますので 、充分な容量の電源をご使用ください 。
3)電源電圧の変動範囲は、許容範囲内としてください 。
4)カウンタの 周 辺 機 器(センサ等)の立ち上がり時間を考慮して、電源ONから200 〜
290ms経過後にカウンタ動作を開始します。200〜 290msの前では入力信号の受付
をしないのでご注意くださ い 。
5)電源OFFから5 〜 1005ms経過 後は入 力を受け付けませんのでご注 意ください 。
6)電源ON/OFF時の突入電流によって電源回路上の接点の劣化が考えられます の で、
定格10A以上の機器での開閉をおすすめしま す 。
7)外部供給電源の容量は12V 100mAです。
ただしAC24V/DC12〜 24V仕様の機種で外部供給
をご使用の場合、供給する電源電圧に応じて右図のよう
に負荷を軽減してください 。(DC電圧供給時のみ)
8)プリスケール値の設定を間違えるとカウント誤差に つながります 。設定に間違いがないか
確かめてからご使用ください 。
9)各種設定値は、計測対象に合わせて正しく設 定し てください 。設定内容と計測対象の内
容が異なる場合には、意図しない動作により装置の破損や事故の原因になります。
10)高温中に長時間、出力電流を流した状態で放置されますと、内部部品(電解コンデンサ
等)の劣化を早める恐れがあります ので 避 けてください 。
11)EEP-ROMにより停電記憶を行っています。EEP-ROMの書き換え寿命は10万回です。
EEP-ROMは電源OFF時および機能設定モード/機種選択モードから運転モードに移
行する時に書き換えます。
12)本製品を廃棄する場合は、各地方自治体の産業廃棄物処理方法に従って処理してく
ださい 。
13)フロントパ ネルを必ず 取り付けた状 態 で使 用してください 。フロントパネルは4 辺 中 央 のツ
メで本体に固定されています。取り外しは、4つのツメを広げながら手前 に引きます。取り
付けは、4つのツメがすべて本体の 溝に納まるように は め 込 んでください 。
使用上の注意
電源
100
負荷
電流
(mA)
20
0
電源電圧(VDC)
ご使用
10.8 15
EN/IEC規格対応について
・EMC に適合するための、ケーブル選定・その他の条件については、本取扱説明書
の記載内容を参照してください 。
・この商 品は「classA」(工業環境商品 )です。住宅環境でご利用されると、電波妨
害の原因となる可能性があります。その場合には電波妨害に対する適切な対策が必
要となります 。
・電源ー入力、電源ー出力、入力ー出力端子間は基礎絶縁です。
(形 H7CX-A□D は電源ー入力間は非絶縁です。)
・二重絶縁または強化絶縁が必要な場合、空間距離や固体絶縁などにより最高使用
電圧に適した、IEC60664 にて定義されている二重絶縁または強化絶縁を施してく
ださい 。
・入力、出力端子は露出した充電部をもたない装置に接続してくださ い 。
端子配置
・電源仕様を確認し、配線をしてください 。
・アキ端子は使用しないでください 。
形H7CX-A-N/-A4-N
1段接点出力
0V
(−)
センサなど
(+)
DC12V
外部供給電源
形H7CX-AS-N/-A4S-N
1段トランジ スタ出 力
0V
(−)
センサなど
(+)
DC12V
外部供給電源
形H7CX-AW-N/-A4W-N/-AWD1-N
2段接点出力
0V
(−)
センサなど
(+)
DC12V
外部供給電源
形H7CX-AWSD-N/-A4WSD-N
2段トランジスタ 出 力
0V
①−⑥端子
は内部で接
続されてい
ます。
形H7CX-A11S-N/-A114S-N/-A11SD1-N
1段トランジスタ 出 力
リセット
CP1
CP2
トータルリセット
0V
(−)
センサなど
DC12V
(+)
外部供給電源
入力の接続
●無電圧入力(NPN入力)
〈オープンコレクタ〉
PLC、
センサなど
0V
※トランジスタO Nで 動 作
●電圧入力(PNP入力)
〈無接点入力(NPNトランジスタ)〉 〈無接点入力(PNPトランジスタ)〉
センサなど
0V
※トランジスタO F Fで 動 作
リセット
CP2
CP1
678910
11
12345
OUT
リセット
CP2
CP1
678910
11
12345
OUT
リセット1
CP2
CP1
678910
11 12 13
12345
OUT2
(+)(−)
リセット1
CP2
CP1
678910
12 13
12345
OUT2
(+)(−)
6
5
7
4
8
3
9
2
10
111
(+)(−)
リセッ ト
CP
リセッ ト
CP
トータルリセット
トータルリセット
リセット2
OUT1
リセット2
OUT1
*
内部回路
OUT
〈電圧出力〉 〈有接点入力〉
センサなど
センサなど
形H7CX-AD-N/-A4D-N
1段接点出力
リセット
0V
678910
12345
(+)(−)
形H7CX-ASD-N/-A4SD-N
1段トランジ スタ出 力
リセット
0V
678910
12345
(+)(−)
形H7CX-AWS-N/-AWSD1-N
2段トランジスタ 出 力
0V
678910
(−)
センサなど
(+)
DC12V
11 12 13
外部供給電源
12345
形H7CX-A11-N/-A114-N/-A11D1-N
/-A114D1-N
1段接点出力
リセット
CP1
CP2
トータルリセット
(−)
センサなど
DC12V
(+)
外部供給電源
*:
負荷
+
負荷用電源
・誘導負荷使用時
*
0V
リセッ ト
CP
※トランジスタO Nで 動 作
リセッ ト
0V
CP
※トランジスタO Nで 動 作
トータルリセット
CP2
CP1
OUT
トータルリセット
CP2
CP1
OUT
リセット1
CP2
CP1
OUT2
(+)(−)
6
5
7
4
0V
3
2
10
1
11
(+)(−)
負荷
負荷用電源
カウンタ
+
負荷用電源
0V
※接点ONで動作
〈有接点入力〉
0V
※接点ONで動作
①−⑥端子は
内部で接 続さ
れています。
①−⑥端子は
内部で接 続さ
れています。
**
リセット2
OUT1
*
内部回路
8
9
OUT
+
誘導負荷
リセッ ト
CP
リセッ ト
CP
キープロテクトスイッチの 設 定
キープロテクトスイッチ「ON」時は、
下表のキープロテクトレ ベ ル(KP-1
〜KP-7)に応じて、各キーの操作を
禁止し、誤設定を防止することがで
きます 。
※キープロテクトレベルは機能設定モード
で設定します。
*モードの移行
レベル
KP-1(初期値)
KP-2
KP-3
KP-4
KP-5
KP-6
KP-7
*「機種選択モード」・「機能設定モード」への移行
不可
不可
不可
不可
不可
不可
不可
運転モードでの表示切替
可
可
可
可
不可
不可
不可
キープロテクト表示
OFF(無効)
(出荷時設定)
リセットキー
可
不可
可
不可
不可
可
不可
ON(有効)
アップ/ダウンキー
可
可
不可
不可
不可
可
可
自己診断機能
異常が発 生した時は下記の表 示になります。
第1表示
-----
(----)
*1*5
fffff
(ffff)
*1*5
e1
e2
e2
e3
*8
*1.( )内は 4 桁タイプ の場合
*2.EEP-ROMの書き換え寿命に達した場合も含みます。
*3.カウント値 、トータルカウント値が−99999(4 桁タイプは−999)を下回った場 合に発 生します。
*4.以下の使用条件で、カウント値(計測値)が 999999(4 桁タイプは9999)を上回った場合 に発 生します。
・出力モードが 、K-2、D、L、Hの場合
・デュアルカウンタ、タコメータ使用の場合
*5.点滅表示します。(1 秒周期)
*6.タコメータ使用の場合は除く。
*7.出力 2 点タイプの場合、いずれか一方が警報設定値以上になると表示されます。
リセットキーによって 、トータルON 回数はクリアされません。
*8.e3と通常 表 示を交 互に 表 示します。
リセットキーを押 すと、警報設定値以上でもe3は表示しません(ただし、出力 ON 回数はクリアされずカウント継 続する
ため、モニタは可 )
東京都品川区大崎1-11-1ゲートシティ大崎 ウエストタワ ー
●
技術的なお問い合わせ
0120−919−066(フリ−コ−ル)
携帯電話・PHSなどは
直通の制御機器の技術窓口は
■営業時間:
■営業日:年末年始を除く
●FAXによる お 問 い 合 わ せ
テクニカルセンタ お客様相談室
●インターネットによるお問い 合 わせ / F A Q(よくあるご質 問 )の検索はオムロン
IndustrialWebをご利用ください 。 http://www.fa.omron.co.jp/
内容
第2表示
カウント値
変化なし
アンダーフロー
カウント値
変化なし
オーバーフロー
CPU異常
消灯
メモリ異 常(RAM)
消灯
メモリ異 常(EEP-ROM)
sum
出力回数オーバー
変化なし
インダストリア ル オートメーションビジネスカンパニー営業統轄事業部
9:00 〜 12:00/13:00 〜 19:00(土・日・祝祭日は17:00まで)
出力状態
変化なし
*3
変化なし
*4
OFF
OFF
*2
OFF
変化なし
055-982-5015です。
055-982-5000です。
復帰方法
リセットキーまたは
リセット入力
*6
リセットキーまたは
リセット入力
*6
リセットキーまたは
電源再投入
電源再投入
リセットキー
*7
リセットキー
14F(〒141-0032)
復帰後の設定値
出荷時の状態
FAX055-982-5051
変化なし
変化なし
変化なし
変化なし
変化なし