6 Power Relays G7Z
■Characteristics
Note: 1. The above values are initial values.
2. The contact resistance for the Relay (G7Z) was measured with 1 A at 5 VDC using the voltage drop method.
The contact resistance for the auxiliary contact block (G73Z) was measured with 0.1 A at 5 VDC using the voltage drop method.
3. The operate time was measured with the rated voltage imposed with any contact bounce ignored at the ambient temperature of 23
°C.
4. The insulation resistance was measured with a 1,000-VDC megohmmeter applied to the same places as those used for checking the dielectric strength.
5. The electrical endurance was measured at an ambient temperature of 23
°C.
6. The specifications for the auxiliary contact block mounted on the G7Z are the same as those for the G73Z auxiliary contact block.
■Approved Standards
UL Standard: UL508, UL840 (File No.
E41643)
Note: Auxiliary contact ratings
CSA Standard: CSA Certification by
: CSA C22.2 No. 14
EN Standard/TÜV Certification: EN
60947-4-1 (Certification No. R50079155)
Note: Auxiliary contact ratings
Reference Information
UL 508: Industrial control devices
UL 840: Insulation coordination including clearance
and creepage distance for electrical devices
CSA C22.2 No. 14: Industrial control devices
EN 60947-4-1: Contactors
Classification Relay (See note 6.) Auxiliary contact block
Item Model G7Z-4A-@Z, G7Z-3A1B-@Z, G7Z-2A2B-@Z G73Z-20Z, G73Z-11Z, G73Z-02Z
Contact resistance (S ee note 2.) 100 mΩ max.
Operating time (See note 3.) 50 ms max.
Release time (See note 3.) 50 ms max.
Maximum operating
frequency
Mechanical 1,800 operations/h
Rated load 1,200 operations/h
Insulation resistance (See note 4.) 1,000 M
Ω min.
Dielectric strength Between coil and contacts 4,000 VAC, 50/60 Hz for 1 min ---
Between contacts of different polarity 4,000 VAC, 50/60 Hz for 1 min
Between contacts of the same polarity 2,000 VAC, 50/60 Hz for 1 min
Impulse withstand
voltage
Between coil and contacts 10 kV, 1.2
× 50 µs ---
Between contacts of different polarity 10 kV, 1.2
× 50 µs
Between contacts of the same polarity 4.5 kV, 1.2
× 50 µs
Vibration resistance Destruction 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)
Malfunction NO: 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)
NC: 10 to 32 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)
Shock resistance Destruction
Screw mounting: 800 m/s
2
, DIN Track mountin g: 500 m/s2
Malfunction
NO: 100 m/s
2
NO: 25 m/s
2
Endurance Mechanical 1,000,000 operations min. (at 1,800 operations/h, contact no load)
Electrical (See note 5.) AC resistive load: 80,000 operations
AC indu ctive load: 80,000 operations
DC resistive load: 100,000 operations
(at 1,200 operations/h, rated load)
Failure rate P value (reference value) 2 A at 24 VDC 1 mA at 5 VDC
Ambient operating temperature
−25 to 60°C (with no icing or condensation)
Ambient operating humidity 5% to 85%
Weight Approx. 330 g
Model Coil
ratings
Contact ratings Numbe r of
test
operations
G7Z 12, 24 VDC NO
contact
40 A, 480 VAC, 60 Hz
(Resistive)
80,000
5 A, 120 VDC (Resistive) 100,000
22 A, 480 VAC, 60 Hz
(General Use)
100,000
D300* (1-A current applied) ---
NC
contact
25 A, 480 VAC, 60 Hz
(Resistive)
5 A, 120 VDC (Resistive)
10 A, 480 VAC, 60 Hz
(General Use)
100,000
D300* (1-A current applied) ---
Model Contact ratings
G73Z NO contact D300 (1-A current applied)
NC contact
Model Coil ratings Con tact ratings
G7Z 12, 24 VDC NO contact AC-1: 40 A, 440 V, 50/60 Hz
AC-3: 16 A, 440 V, 50/60 Hz
DC-1: 5 A, 110 V
*AC15: 0.5 A, 440 V, 50/60 Hz
*DC13: 0.5 A, 110 V
NC contact AC-1: 25 A, 440 V, 50/60 Hz
DC-1: 5 A, 110 V
*AC15: 0.5 A, 440 V, 50/60 Hz
*DC13: 0.5 A, 110 V
G73Z --- NO contact AC15: 0.5 A, 440 V , 50/60 Hz
DC13: 0.5 A, 110 V
NC contact