G7S
G7S
2
Specifications
Ratings
Operation Coil
Rated voltage Rated current Coil resistance Must operate
voltage
Must release
voltage
Max. voltage Power
consumption
24 VDC 30 mA 800 Ω 80% max. (V) 10% min. (V) 110% (V) Approx. 0.8 W
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of ±15%.
2. Performance characteristics are based on a coil temperature of 23°C
3. The maximum voltage is based on an ambient operating temperature of 23°C maximum.
Switching Section (Contact Ratings)
Load Resistive load (cos φ =1) Inductive load (cos φ = 0.4, L/R = 7 ms)
Rated load 240 VAC: 3 A, 24 VDC: 3 A 240 VAC: 3 A, 24 VDC: 1 A
Rated carry current 6 A
Maximum switching voltage 250 VAC, 24 VDC
Maximum switching current 6 A
Maximum switching capacity (reference
value)
1,440 VA, 144 W
Min. permissible load
(See note.)
5 VDC, 10 mA
Contact material Ag ) Au
Note: The above values are based on an operating frequency of 60 operations/min.
Characteristics
Contact resistance (See note 2.) 100 mΩ max.
Operate time (See note 3.) 50 ms max.
Release time (See note 3.) 50 ms max.
Maximum operating
Mechanical 18,000 operations/hr
frequency
Rated load 1,800 operations/hr
Insulation resistance 100 MΩ min. (at 500 VDC)
Dielectric strength 2,500 VAC, 50/60 Hz for 1 min (1,500 VAC between contacts of same polarity)
Vibration
Destruction 10 to 55 Hz, 1.5-mm double amplitude
Malfunction 10 to 55 Hz, 0.75-mm double amplitude
Shock
Destruction 1,000 m/s2 (approx. 100G)
Malfunction 100 m/s2 (approx. 10G)
Life expectancy
Mechanical 10,000,000 operations min. (at approx. 18,000 operations/hr)
Electrical 100,000 operations min. (at the rated load and approx. 1,800 operations/hr)
Ambient operating temperature –10°C to 70°C (no icing)
Ambient operating humidity 35% to 85% RH
Ambient storage temperature –25°C to 70°C (no icing)
Ambient storage humidity 35% to 85% RH
Weight Approx. 65 g
Note: 1. The values given above are initial values.
2. Measurement conditions: 5 VDC, 10 mA, voltage drops.
3. Measurement conditions:
Rated voltage operation
Ambient operating temperature: 23°C
Does not include bounce time.
Characteristics of Safety Relay Socket
Model Continuous current Dielectric strength Insulation resistance
P7S-14j
6 A 2000 VAC for 1 min. between terminals 1000 MΩ min. (see note)
Note: Measurement conditions: Measurement of the same points as for the dielectric strength at 500 VDC.