G6D
■Application Examples
• Ideal for output applications of control
equipments.
■Characteristics
Note. The data given above are initial values.
*1. Measurement conditions: 5 VDC, 1 A, voltage
drop method.
*2. Measurement conditions: The insulation
resistance was measured with a 500 VDC
megohmmeter at the same locations as the
dielectric strength was measured.
*3. This value was measured at a switching
frequency of 120 operations/min.
*4. The values indicated in parentheses ( ) are
for the G6D-1A-ASI-AP.
Contact resistance *1 100 mΩ max.
Operate time 10 ms max.
Release time 5 ms max.
Insulation resistance *2 1,000 MΩ min.
Dielectric
strength
Between coil
and contacts
3,000 VAC, 50/60 Hz for
1min
Between
contacts of
the same
polarity
750 VAC, 50/60 Hz for
1min
Impulse withstand voltage
(between coil and contacts)
6 kV (1.2 x 50
μ
s)
Vibration
resistance
Destruction
10 to 55 to 10 Hz, 0.75 mm
single amplitude (1.5 mm
double amplitude)
Malfunction
10 to 55 to 10 Hz, 0.75 mm
single amplitude
(1.5 mm double amplitude)
Shock
resistance
Destruction 1,000 m/s
2
Malfunction 100 m/s
2
Durability
Mechanical
20,000,000 operations min.
(at 18,000 operations/hr)
Electrical
70,000 operations min.
(5 A at 250 VAC, resistive
load)
70,000 operations min.
(5 A at 30 VDC, resistive
load)
300,000 operations min.
(2 A at 250 VAC, resistive
load)
300,000 operations min.
(2 A at 30 VDC, resistive
load)
(at 1,800 operations/hr)
Failure rate (P level)
(reference value *3)
10 mA at 5 VDC
(1 mA at 5 VDC) *4
Ambient operating
temperature
-25 C to 70 C (with no icing
or condensation)
Ambient operating humidity 5% to 85%
Weight Approx. 3 g
■Model Number Legend
G6D-@@-@-@
—— — —
12 3 4
1. Number of Poles
1: 1-pole
2. Contact Form
A: SPST-NO (1a)
3. Contact Material
ASI: Silver alloy
(cadmium-free)
4. Contact surface
AP: Au plated
■Ordering Information
●Connecting Socket
■Ratings
●Coil
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of
±10%.
Note 2. The operating characteristics are measured at a coil temperature of 23°C.
Note 3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
* The must operate voltage is 75% or less of the rated voltage if the relay is mounted upside down.
●Contacts
Enclosure rating Contact form Terminal shape Model Rated coil voltage
Minimun packing
unit
Fully sealed SPST-NO (1a) PCB terminals
G6D-1A-ASI
5 VDC
25 pcs/tube
12 VDC
24 VDC
G6D-1A-ASI-AP
12 VDC
24 VDC
Applicable relay Model Minimun packing unit
G6D-1A-ASI P6D-04P 25 pcs
Item
Rated voltage
Rated
current
(mA)
Coil
resistance
(Ω)
Must operate
voltage
(V)
Must release
voltage
(V)
Max.
voltage
(V)
Power
consumption
(mW)
% of rated voltage
5 VDC 40 125
70% max.* 10% min.
160%
(at 23 C)
Approx. 20012 VDC 16.7 720
24 VDC 8.3 2,880
Item Load Resistive load
Contact Type Single
Contact material
Ag-Alloy (Cd free)
(Ag-alloy (Cd free) and Au plated)*
Rated load
5 A at 250 VAC
5 A at 30 VDC
Rated carry current 5 A
Max. switching voltage 250 VAC, 30 VDC
Max. switching current 5 A
Note. When ordering, add the rated coil voltage to the model number.
Example: G6D-1A-ASI DC5
However, the notation of the coil voltage on the product case as well as on the packing will be marked
as @@ VDC.
Rated coil voltage
* The content indicated in
parentheses ( ) are for
the G6D-1A-ASI-AP
PCB Power Relay
Slim, Miniature Relay, Capable
of Relaying Programmable
Controller and Temperature
Controller Outputs
• Reduced board space, ideal for high-density mounting (45%.
(6.5 mm (W) × 17.5 mm (L) × 12.5 mm (H))
• Small, yet switches 5 A at 250 VAC/30 VDC.
• Allows 300,000 operations with a 2A load at 250 VAC or
30 VDC.
RoHS Compliant
G
6
D
1

G6D PCB Power Relay
Switching current (A)
Switching voltage (V)
50
30
10
5
3
1
0.5
0.3
0.1
0 3 5 10 30 100 250 500 1,000
AC resistive load
AC inductive
load
cosφ=0.4
DC resistive load
DC inductive load
Maximum coil voltage (%)
Ambient temperature (°C)
200
180
160
140
120
100
80
60
0 23 30 40 50 60 70 80 90
100
80
60
40
20
0
Ambient temperature (°C)
Must operate and must release voltage (ratio of rated voltage) (%)
Sample: G6D-1A-ASI
Number of Relays:
5 pcs
-40 -20 0 20 40 60 80
Must Operating voltage
Must Recovery voltage
max.
min.
X
max.
min.
X
17.5 max.
(17.3)*
6.5 max.
(6.4)*
12.5 max.
(12.4)*
2.54
2.54
(1.13)
(0.71)
5.08
10.16
5.08
Four, 1.1-dia.
1
57
13
0.5
3.5
0.3
5.087.622.54
0.5 0.8
5.08
* Average value
Note: Orientation marks are indicated as follows:
G6D-1A-ASI (-AP)
Terminal Arrangement/
Internal Connections
(Bottom View)
PCB Mounting Holes
(Bottom View)
(No coil polarity)
19.7 max.
(19.5)*
6.9 max.
(6.7)*
2.54
2.54
(2.18)
(0.86)
5.08
10.16
5.08
Four, 1.1-dia.
10.8
0.3
3.6
7.622.54
0.65
5.08
* Average value
6
±0.1
Socket
P6D-04P
PCB Mounting Holes
(Bottom View)
■Engineering Data
●Maximum Switching Capacity ●Durability ●Ambient Temperature vs.
Maximum Coil Voltage
500
300
operations)
4
100
250 VAC/30 VDC resistive load
Switching current (A)
Y
1,000
800
600
400
200
Z
Note. The maximum coil voltage is the maximum
voltage that can be applied to the relay coil.
●Ambient Temperature vs. Must
Operate and Must Release
Voltages
G6D-1A-ASI (-AP)
G
6
D
50
30
Durability (x10
10
250 VAC/30 VDC inductive load
5
(cosφ=0.4/ L/R=7 ms)
3
1 2 3 4 5 6 7 8 9 10
0
●Shock Malfunction
G6D-1A-ASI (-AP)
X
■Dimensions
2
Z'
De-energized
Energized
Sample: G6D-1A-ASI 24 VDC
Number of Relays: 5 pcs
Test conditions: Impose a shock in the ±X, ±Y, and ±Z
directions three times each with the Relay energized to
check the shock values that cause the Relay to
malfunction.
206
Y'
Unit: m/s
X'
Shock direction
X
Y
2
Y'
Coil terminals
X'
Z
Z'

G6D PCB Power Relay
●Mounting
• More than two relays can be closely
mounted right side up as shown in the
following illustration.
Note. The space between each relay required for
heat radiation may vary with operating
conditions. Contact your OMRON
representative for details.
• Use Surge Killer Diode when switching
a DC inductive load in micro load
(about 10 to 100 mA).
(Carbon deposition may decrease the
contact reliability.)
●Socket Mounting Height
●Mounting to a P6D
• The P6D is flux-resistive. Do not wash
the P6D with water.
• Dismount the relay from the socket
before soldering the socket to a PCB.
Correct Use
Upper side Upper side
6.5 mm
Current flow: 5 A max.
1.12 mm 7.62 mm in the
upside-down direction
Current flow: 2 A max.
■Approved Standards
●The rated values approved by each of the safety standards may be different from the performance characteristics individually defined in
this datasheet.
UL Recognized (File No. E41515)
Model
G6D-1A-ASI (-AP) 1 5 to 24 VDC
CSA Certified
Model
G6D-1A-ASI (-AP) 1 5 to 24 VDC
EN/TÜV Certified
Model
G6D-1A-ASI (-AP) 1 5, 12, 24 VDC
Number of
poles
Coil ratings Contact ratings
(File No. LR31928)
Number of
poles
Coil ratings Contact ratings
(Registration No. R50167084)
Number of
poles
Coil ratings Contact ratings
5 A, 250 VAC 40°C
5 A, 30 VDC 40°C
5 A, 250 VAC (Resistive) 40°C
5 A, 30 VDC (Resistive) 40°C
5 A, 250 VAC (cosφ=1.0) 70°C
5 A, 30 VDC (0 ms) 40°C
■Precautions
●Please refer to “PCB Relays Common Precautions” for correct use.
Number of test
operations
6,000
Number of test
operations
6,000
Number of test
operations
70,000
G
6
D
3

G6D PCB Power Relay
· Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
· Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
OMRON Corporation
Electronic and Mechanical Components Company
Contact: www.omron.com/ecb
Cat. No. K127-E1-04
0316(0207)(O)
Note: Do not use this document to operate the Unit.
G
6
D
4