Omron G3PB-515B-VD, G3PB-525B-VD, G3PB-535B-VD, G3PB-545B-VD User Manual

Solid State Relays (Single-phase) G3PB 1
Solid State Relays (Single-phase)
G3PB
Compact, Slim-profile SSR with Heat Sink, Offering Heater Control for 480-VAC Rated Loads
• Compact design achieved by optimizing heat sink shape.
• Conforms to CE Marking, EN (VDE approval), CSA, and VDE standards. (UL pending)
Note: Refer to Precautions on page 5.
Model Number Structure
Model Number Legend
1. Basic Model Name
G3PB: Solid State Relay
2. Rated Load Power Supply Voltage
5: 480 VAC
3. Rated Load Current
15: 15 A 25: 25 A 35: 35 A 45: 45 A
4. Termi nal Type
B: Screw terminals
5. Number of Elements
Blank: Single-phase models
6. Construction
Blank: DIN track mounting and built-in heat sink
7. Certification
VD: Certified by CSA and VDE
Ordering Information
List of Models
Note: The applicable load current varies depending on the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in
Engineering Data.
Accessories (Order Separately)
1
234
56 7
G3PB-@@@-@@-@
Isolation method Zero cross
function
Operation
indicator
Rated input
voltage
Rated output load
(See note.)
Model number
Phototriac coupler Yes Yes (yellow) 12 to 24 VDC 15 A, 200 to 480 VAC G3PB-515B-VD 12 to 24 VDC
25 A, 200 to 480 VAC G3PB-525B-VD 12 to 24 VDC
35 A, 200 to 480 VAC G3PB-535B-VD 12 to 24 VDC
45 A, 200 to 480 VAC G3PB-545B-VD 12 to 24 VDC
Mounting Track 50 cm (1) x 7.3 mm (t) PFP-50N
1 m (1) x 7.3 mm (t) PFP-100N
1 m (1) x 16 mm (t) PFP-100N2
2 Solid State Relays (Single-phase) G3PB
Specifications
Ratings (at an Ambient Temperature of 25°C)
Input
Output
Note: The applicable load current varies depending on the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in
Engineering Data.
Characteristics
Item Common
Rated voltage 12 to 24 VDC
Operating voltage range 9.6 to 30 VDC
Rated input current 7 mA max.
Must operate voltage 9.6 VDC max.
Must release voltage 1 VDC min.
Item G3PB-515B-VD G3PB-525B-VD G3PB-535B-VD G3PB-545B-VD
Rated load voltage 200 to 480 VAC (50/60 Hz)
Load voltage range 180 to 528 VAC (50/60 Hz)
Applicable load current (See note.) 0.1 to 15 A (at 40
°C) 0.1 to 25 A (at 40°C) 0.5 to 35 A (at 25°C) 0.5 to 45 A (at 25°C)
Inrush current resistance (peak value) 150 A
(60 Hz, 1 cycle)
220 A (60 Hz, 1 cycle)
440 A (60 Hz, 1 cycle)
Permissible I
2
t
(half 60-Hz wave)
128 A2s 1,350 A2s 6,600 A2s
Applicable load (with Class-1 AC resistive load)
6 kW max. (at 400 VAC)
10 kW max. (at 400 VAC)
14 kW max. (at 400 VAC)
18 kW max. (at 400 VAC)
Item G3PB-515B-VD G3PB-525B-VD G3PB-535B-VD G3PB-545B-VD
Operate time 1/2 of load power source cycle + 1 ms max.
Release time 1/2 of load power source cycle + 1 ms max.
Output ON voltage drop 1.8 V (RMS) max.
Leakage current 20 mA max. (at 480 VAC)
Insulation resistance 100 M
min. (at 500 VDC)
Dielectric strength 2,500 VAC, 50/60 Hz for 1 min
Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude)
(Mounted to DIN track)
Shock resistance
Destruction: 294 m/s
2
(DIN track mounting)
Ambient temperature Operating:–30
°C to 80°C (with no icing or condensation)
Storage: –30
°C to 100°C (with no icing or condensation)
Ambient humidity Operating: 45% to 85%
Certified standards CSA22.2 No. 14
EN60947-4-3
EMC Emission EN55011 Group 1 Class B
Immunity ESD IEC947-4-3, EN61000-4-2
4 kV contact discharge 8 kV air discharge
Immunity Electromagnetic IEC947-4-3, EN61000-4-3
10 V/m (80 MHz to 1 GHz)
Immunity EFT IEC947-4-3, EN61000-4-4
2 kV AC power-signal line
Immunity Surge transient IEC947-4-3, EN61000-4-5
Normal mode
±1 kV, Common mode ±2 kV
Immunity RF disturbance IEC947-4-3, EN61000-4-6
10 V (0.15 to 80 MHz)
Immunity Dips IEC947-4-3, EN61000-4-11
Weight Approx. 240 g Approx. 400 g
Solid State Relays (Single-phase) G3PB 3
Engineering Data
Input Voltage vs. Input Impedance and Input Voltage vs. Input Current
Load Current vs. Ambient Temperature
G3PB-515B-VD, G3PB-525B-VD G3PB-535B-VD, G3PB-545B-VD
One Cycle Surge Current: Non-repetitive
Keep the inrush current to below the inrush current resistance value (i.e., below the broken line) if it occurs repetitively.
G3PB-515B-VD G3PB-525B-VD G3PB-535B-VD, G3PB-545B-VD
Close Mounting (8 Relays)
G3PB-515B-VD, G3PB-525B-VD G3PB-535B-VD, G3PB-545B-VD
Input voltage (V)
Input Impedance
Ta = 25°C
10
9
8
7
6
5
4
3
2
1
0
5 10152025303540
Input current
Input impedance (k
)
Input current (mA)
30
25
20
15
10
7
0
30 20 0 20 40 60 80 10
0
G3PB-525B-VD
G3PB-515B-VD
Load current (A)
Ambient temperature (°C)
50
45
40
35
30
20
10
0
30 20 0 20 40 60 80 10
0
14
18
25
G3PB-545B-VD
G3PB-535B-VD
Ambient temperature (°C)
Load current (A)
250
200
150
100
50
0
Inrush current (A. Peak)
10 30 50 100 300 500 1,000 3,000 5,000
Energized time (ms)
Inrush current (A. Peak)
Energized time (ms)
250
200
150
100
50
0
10 30 50 100 300 500 1,000 3,000 5,000
Energized time (ms
)
Inrush current (A. Peak)
500
400
300
200
100
0
10 30 50 100 300 500 1,000 3,000 5,000
40 20 0 20 40 60 80 100
30
16
5
6
10
12
20
0
G3PB-525B-VD
G3PB-515B-VD
Ambient temperature (°C)
Load current (A)
40 20 0 20 40 60 80 100
40
30 29
26
20
10
0
G3PB-545B-VD
G3PB-535B-VD
25
Ambient temperature (˚C
)
Load current (A)
DIN Trac
k
Close Mounting Example
Loading...
+ 5 hidden pages