Omron G3NE DATASHEET

Solid State Relays
G3NE
Compact, Low-cost, SSR Switching 5 to 20 A
• Wide load voltage range: 75 to 264 VAC. Both 100-V and 200-V loads can be handled with the same model.
• Dedicated, compact aluminum PCB and power elements used.
• Quick-connect #110 input terminals and #250 output connections. (#187 input terminals and #250 output connections are available.)
• “-US” models certified by UL, CSA, and IEC/EN (TÜV).
Model Number Structure
Model Number Legend
G3NE-@@@@-@-@
67
5
234
1
1. Basic Model Name
G3NE: Solid State Relay
2. Rated Load Power Supply Voltage
2: 200 VAC
3. Rated Load Current
05: 5 A 10: 10 A 20: 20 A
4. Terminal Type
T: Quick-connect terminals
5. Zero Cross Function
Blank: Equipped with zero cross function L: Not equipped with zero cross function
6. Special Specifications
Blank: Standard models 2: #187 input terminals
7. Certification
US: Certified by UL, CSA, and TÜV
SSR
Solid State Relays G3NE J-17
Ordering Information
List of Models
Isolation Zero cross
Phototriac Yes No 5 A at 100 to 240 VAC 5, 12, 24 VDC G3NE-205T-US
Note: When ordering, specify the input voltage.
function
No 5 A at 100 to 240 VAC G3NE-205TL-US
Indicator Rated output load Rated input voltage Model
G3NE-205T-2-US
10 A at 100 to 240 VAC G3NE-210T-US
G3NE-210T-2-US
20 A at 100 to 240 VAC G3NE-220T-US
G3NE-220T-2-US
G3NE-205TL-2-US
10 A at 100 to 240 VAC G3NE-210TL-US
G3NE-210TL-2-US
20 A at 100 to 240 VAC G3NE-220TL-US
G3NE-220TL-2-US
Accessories (Order Separately)
Heat Sinks
The following heat sinks are thin and can be DIN-track mounted. See Dimensions for details.
Model Applicable SSR Y92B-N50 G3NE-205T(L)(-2)-US/-210T(L)(-2)-US Y92B-N100 G3NE-220T(L)(-2)-US
Specifications
Ratings (at an Ambient Temperature of 25°C)
Input
Rated voltage Operating voltage Voltage level Input impedance
Must operate Must release With zero cross function Without zero cross function
5 VDC 4 to 6 VDC 4 VDC max. 1 VDC min. 250 Ω±20% 300 Ω±20% 12 VDC 9.6 to 14.4 VDC 9.6 VDC max. 600 Ω±20% 800 Ω±20% 24 VDC 19.2 to 28.8 VDC 19.2 VDC max. 1.6 kΩ±20%
Note: Each model has 5-VDC, 12-VDC, and 24-VDC input versions.
Output
Model Applicable load
Rated load voltage Load voltage range Load current
With heat sink Without heat sink G3NE-205T(L)(-2)-US 100 to 240 VAC 75 to 264 VAC 0.1 to 5 A 0.1 to 5 A 60 A (60 Hz, 1 cycle) G3NE-210T(L)(-2)-US 0.1 to 10 A
G3NE-220T(L)(-2)-US 0.1 to 20 A
Note: 1. The load current varies depending on the ambient temperature. Refer to Load Current vs. Ambient Temperature under Engineering Data
for details.
2. These values apply when using a dedicated heat sink or a radiation plate of specified size.
(See note 2.)
(See note 2.)
(See note 1.)
0.1 to 5 A 150 A (60 Hz, 1 cycle)
0.1 to 5 A 220 A (60 Hz, 1 cycle)
Inrush current
J-18 Solid State Relays G3NE