F3S-TGR-SB@C series has been developed especially for
Palletisers and wrapping machine access protection applications.
Active - Passive system and Plug and play
By using a mirror system we can achieve an active - passive
multi beam system. This active passive system will improve
installation time and reduce costs.
3 Different types available
We provide 3 different Types as following:
• 2 beam Type (beam pitch 500 mm)
• 3 beam Type (beam pitch 400 mm)
• 4 beam Type (beam pitch 300 mm)
800 mm
500 mm
Muting functions are integrated
Following Muting functions are integrated:
• Muting sensor inputs
• Muting Lamp output
• Override input (120 second max)
• Test / Reset input
• Interlock function and Test Reset input
900 mm
F3S-TGR
G-49F3S-TGR-SB@C series
Page 2
Decentralized Muting connection Box
Furthermore, using a F39-TGR-SB-CMB1, it’s possible to reduce the wiring time and wiring material for the muting Sensors and Muting Lamp etc.
In the conventional solution all wires from the light curtain, mute sensors, lamp,
reset are wired back to the mute controller in the control cabinet (See Ex. 1)
As you can see this solution need JUST ONE WIRE to the cabinet (See Ex. 2)
Ex. 1Ex. 2
To Barrier
Multiple mute connections are possible
1. PARALLEL MUTING and TWO WAY direction2. PARALLEL MUTING and ONE WAY direcion
A2 B2B1 A1
Pallet
Danger Zone
3. CROSS MUTING and TWO WAY direction4. CROSS MUTING and ONE WAY direction
B2A2
Danger Zone
Please add MTL*. Ex. F3S-TGR-SB4-K1CMTL
Pallet
Danger Zone
Danger Zone
A2 B2
Pallet
B2 A2
Pallet
To Cabinet
Reference
Muting Lamp Override and Test SwitchF3S-TGR-SB@-K@CMuting sensor
Mechanical Guard*MTL has a special software inside of F3S-TGR-SB@C which works to finalize a Muting function.
Muting Sensors Recommendation
It is recommended to use the E3Z or E3G as muting sensor. Please refer to the E3Z datasheet Cat.No. E701-E2-Cat04-01 and
the E3G datasheet Cat.No. E278-E2-Cat04-03.
SOLUTION 1: Object Gaps
In many palletiser applications
there is a gap between objects
on the pallet. The Muting function
may not work correctly because
of this gap. To avoid the mutual
interruption, we recommend to
Use E3G@@@@T as muting sensor. E3G-@@@@T has ON delay
timer internally (0 to 5 seconds)
G-50Safety Sensors / Components
Object
Gaps
Please add MTL*. Ex. F3S-TGR-SB4-K1CMTL
F3S-TGR-SB-CMB@
SOLUTION 2: Misalignment of pallets
When using a
CROSS MUTING
system, It may
cause that unexpected behavior
when the pallets get
out of alignment
then E3G@@@@T
also solves the
problem by OFF delay timer (0 to 5 seconds).
Page 3
List of Models
Safety Multi beam Sensors
F3S-TGR-SB2-K@C Mirror Reflection Type (Type 2)
ShapeNumber of optical
axes
2500F3S-TGR-SB2-K2C-500(MTL)*
3400F3S-TGR-SB2-K3C-800(MTL)*
4300F3S-TGR-SB2-K4C-900(MTL)*
*. If you want to have a ONE WAY direction Type, (see Page D-26) Please add the MTL behind of Model Name. Ex. F3S-TGR-SB4-K2C-500MTL
F3S-TGR-SB4-K@C Mirror Reflection Type (Type 4)
ShapeNumber of optical
axes
2500F3S-TGR-SB4-K2C-500(MTL)*
3400F3S-TGR-SB4-K3C-800(MTL)*
4300F3S-TGR-SB4-K4C-900(MTL)*
*. If you want to have a ONE WAY direction Type, (see Page D-26) Please add the MTL behind of Model Name. Ex. F3S-TGR-SB4-K2C-500MTL
Sensing DistanceBeam
Pitch
0.5 to 6 m
0.5 to 5 m
Sensing DistanceBeam
Pitch
0.5 to 6 m
0.5 to 5 m
Model
Model
Muting Connecting Box (Order Separately)
Flexible Connecting Box
AppearanceSLC Connection
Type
M12 8pin connector
without cable
4 x Muting sensor connection (4pin)
1 x Muting Lamp M12 (4pin)
1 x Override/Test input M12 (4pin)
1 x cabinet connection M12 (8pin)
M12 8pin connector
with 100 mm cable
Other connectionModel
F39-TGR-SB-CMB1
F39-TGR-SB-CMB2
Accessories (Order Separately)
Connector Cable
AppearanceCable lengthSpecificationModel
2 m
5 mF39-TGR-SB4-CVLB5R
10 mF39-TGR-SB4-CVLB10R
M12 connector (8pin Socket)
For cabinet connection
(From F3S-TGR-SB@-K@C or F3S-TGR-
SB-CMB@)
F39-TGR-SB4-CVLB2R
F3S-TGR
2 m
M12 connector (4pin Plug)
For Muting sensor, Muting Lamp connec-
tion and Override/Test connection
F39-TGR-SB4-CVLB2MC
G-51F3S-TGR-SB@C series
Page 4
Connector Plug Assemblies, Screw-on Type
AppearanceCable connection
direction
SpecificationConnection
method
Applicable cable
diameter
Model
Straight
DC only 4pin PlugScrew-on3 dia. (3 to 4 dia.)
Right angleXS2G-D4S6
Muting Lamp
AppearanceSpecificationModel
24 V DCF39-A11
Bulb for Maintenance
AppearanceSpecificationModel
24 V DC 3 W E14F39-A11MB
Laser alignment Kit
AppearanceModel
F39-LKK2-SB
XS2G-D4S5
G-52Safety Sensors / Components
Page 5
Rating and Performance
Safety sensors
F3S-TGR-SB@-K@C
ItemModel
F3S-TGR-SB4-K@C-@@@(MTL)*
Sensor typeType 4Type 2
Applicable safety category4, 3, 2, 1, B2, 1, B
Operating rangeF3S-TGR-SB@-K2C0.5 - 6 m
F3S-TGR-SB@-K3C/K4C0.5 - 6 m
Beam pitch and Number of beamF3S-TGR-SB@-K2C500 mm 2 beam with mirror
F3S-TGR-SB@-K3C400 mm 3 beam with mirror
F3S-TGR-SB@-K4C300 mm 4 beam with mirror
Outermost beam gapF3S-TGR-SB@-K2C500 mm
F3S-TGR-SB@-K3C800 mm
F3S-TGR-SB@-K4C900 mm
Effective aperture angle (EAA)Within ±2.5°Within ±5°
Light sourceInfrared LED (880 nm)
Power supply24 VDC ± 20%
Current Consumption420 mA
OSSDTwo PNP transistor outputs, 250 mA each. (500 mA sum)
Output operation modeLight - ON
Test functionsSelf-test (after power ON and during operation, one cycle during response time)
ProtectionOutput short-circuit protection, Reverse Polarity protection
Response timeON to OFF 16ms max
OFF to ON 300 ms (Maximum Power-ON time is 900 ms)
Ambient temperatureOperating: -10 to +55 °C (with no dew condensation)
Ambient humidity15% to 95% (non condensing)
Metal housing (Al) paintedYellow (RAL 1303 F14)
Degree of protectionIP65
AccessoriesM6 T-Bolt x 8, M6 Nut x 8
Mounting fixture x 4
Applicable standardsEN61496-1; 1997
prEN61496-2; 1997
*. If you want to have a ONE WAY direction Type, (see Page D-26) Please add the MTL behind of Model Name. Ex. F3S-TGR-SB4-K2C-500MTL
F3S-TGR-SB2-K@C-@@@(MTL)*
Muting Connecting Box
F3S-TGR-SB-CMB@
ItemModelF39-TGR-SB-CMB@
Power supply24 VDC ± 20%
Consumption10 W max
Ambient temperatureDuring operation: -10 to +55 °C (with no dex condensation)
Ambient humidity15% to 95% (non condensing)
RX connectorM12 8 pins female
Cabinet connectorM12 8 pins male
Sensor connector4 x M12 4 pins female
Muting indicatorM12 4 pins female
Test / Override connectorsM12 4 pins female
Metal housing (Al) paintedYellow (RAL 1303 F14)
Degree of protectionIP65
MaterialCaseAluminium
ConnectorBrass with nickel plate
Front CoverAluminium
Weight0.5 kg
AccessoriesM6 T-Bolt x 4, M6 Nut x 4
Mounting fixture x 2, Connector cover x 2
F3S-TGR
G-53F3S-TGR-SB@C series
Page 6
ItemModelF39-TGR-SB-CMB@
Applicable standards93/68/EEC
DIN V VDE 0801:1990 and am.A1:1994
EN 50081-2:1993
EN 55022:1998
Dimensions
F3S-TGR-SB-K@C-@@@ with Mounting Brackets
47.537.7
A
35
73C, E
13
ModelACE
F3S-TGR-SB@-K2C500614 mm500 mm500 mm
F3S-TGR-SB@-K3C800914 mm800 mm400 mm
F3S-TGR-SB@-K4C9001,014 mm900 mm300 mm
G-54Safety Sensors / Components
Page 7
F39-TGR-SB-CMB1
Muting connection boxMounting bracket (Common bracket for F3S-TGR-SB@-K@C
and F39-TGR-SB-CMB@
Connector Plug Assemblies, Screw-on Type
XS2G-D4S5
M12 x 1
14.9 dia.
20 dia.
XS2G-D4S6
M12 x 1
14.9 dia.20 dia.
58.7
14 dia.
39.7
39.6
F3S-TGR
14 dia.
G-55F3S-TGR-SB@C series
Page 8
Connection
F3S-TGR-SB@-K@C
Connection example
When using Muting function
Passive side
White
S1
Brown
Green
Active side
Pink
Yellow
Gray
Blue
Red
Shield
Green
MIA
Yellow
MIB
Pink
OSSD1
White
Brown
S1
S1: External Test / Interlock reset Switch
OSSD1
+24Vdc
OSSD2
0Vdc
MIA : Muting input A
MIB : Muting input B
ML : Muting Lamp
In case of Cat 4 (EN954-1), OSSD1/2 must be connected Safety Relay Unit (G9SA, G9SB-301B etc.) with feedback monitor
Pin reference
Front ViewPin No.Signal NameWire Color
1Test and Reset InputWhite
2+24VdcBrown
1
2
8
3
7
4
6
5
3Muting A InputGreen
4Muting B InputYellow
5OSSD1 (OUT1)Gray
6OSSD2 (OUT2)Pink
70VdcBlue
8Muting Lamp (0 Vdc)Red
Gray
OSSD2
Blue
Red
ML
Shield
+24Vdc
0Vdc
G-56Safety Sensors / Components
Page 9
F3S-TGR-SB-CMB@
Pin and Plug reference1) To F3S-TGR-SB Series
1) To Barrier (F3S-TGR-SB series)
M12 8pin connector (Female)
2) Muting Sensor B2
M12 5pin connector (Female)
3) Muting Sensor A2
M12 5pin connector (Female)
4) Muting Sensor B1
M12 5pin connector (Female)
5) Muting Sensor A1
M12 5pin connector (Female)
6) Muting Lamp
M12 5pin connector (Female)
7) Test/Override
M12 5pin connector (Female)
8) From Cabinet
M12 8pin connector (Male)
*1 In case of F3S-TGR-SB-CMB2,
M12 8pin connector with 100 mm cable
*1
Front ViewPin No.Signal NameWire Color
1Test and Reset InputWhite
2+24VdcBrown
3Muting A InputGreen