Omron F3S-TGR-SB2-K2C-500, F3S-TGR-SB2-K3C-800MTL, F3S-TGR-SB2-K2C-500MTL, F3S-TGR-SB2-K3C-800, F3S-TGR-SB2-K4C-900 Datasheet

...
Page 1
Safety sensor for Palletisers
F3S-TGR-SB@C series
Features
For Palletiser
F3S-TGR-SB@C series has been developed especially for Palletisers and wrapping machine access protection applica­tions.
Active - Passive system and Plug and play
By using a mirror system we can achieve an active - passive multi beam system. This active passive system will improve installation time and reduce costs.
3 Different types available
We provide 3 different Types as following:
• 2 beam Type (beam pitch 500 mm)
• 3 beam Type (beam pitch 400 mm)
• 4 beam Type (beam pitch 300 mm)
800 mm
500 mm
Muting functions are integrated
Following Muting functions are integrated:
• Muting sensor inputs
• Muting Lamp output
• Override input (120 second max)
• Test / Reset input
• Interlock function and Test Reset input
900 mm
F3S-TGR
G-49F3S-TGR-SB@C series
Page 2
Decentralized Muting connection Box
Furthermore, using a F39-TGR-SB-CMB1, it’s possible to reduce the wiring time and wiring material for the mut­ing Sensors and Muting Lamp etc.
In the conventional solution all wires from the light curtain, mute sensors, lamp, reset are wired back to the mute controller in the control cabinet (See Ex. 1) As you can see this solution need JUST ONE WIRE to the cabinet (See Ex. 2)
Ex. 1 Ex. 2
To Barrier
Multiple mute connections are possible
1. PARALLEL MUTING and TWO WAY direction 2. PARALLEL MUTING and ONE WAY direcion
A2 B2 B1 A1
Pallet
Danger Zone
3. CROSS MUTING and TWO WAY direction 4. CROSS MUTING and ONE WAY direction
B2 A2
Danger Zone
Please add MTL*. Ex. F3S-TGR-SB4-K1CMTL
Pallet
Danger Zone
Danger Zone
A2 B2
Pallet
B2 A2
Pallet
To Cabinet
Reference
Muting Lamp Override and Test Switch F3S-TGR-SB@-K@C Muting sensor
Mechanical Guard *MTL has a special software inside of F3S-TGR-SB@C which works to finalize a Muting function.
Muting Sensors Recommendation
It is recommended to use the E3Z or E3G as muting sensor. Please refer to the E3Z datasheet Cat.No. E701-E2-Cat04-01 and the E3G datasheet Cat.No. E278-E2-Cat04-03.
SOLUTION 1: Object Gaps
In many palletiser applications there is a gap between objects on the pallet. The Muting function may not work correctly because of this gap. To avoid the mutual interruption, we recommend to Use E3G@@@@T as muting sen­sor. E3G-@@@@T has ON delay timer internally (0 to 5 seconds)
G-50 Safety Sensors / Components
Object Gaps
Please add MTL*. Ex. F3S-TGR-SB4-K1CMTL
F3S-TGR-SB-CMB@
SOLUTION 2: Misalignment of pallets
When using a CROSS MUTING system, It may cause that unex­pected behavior when the pallets get out of alignment then E3G@@@@T also solves the problem by OFF delay timer (0 to 5 seconds).
Page 3
List of Models
Safety Multi beam Sensors
F3S-TGR-SB2-K@C Mirror Reflection Type (Type 2)
Shape Number of optical
axes
2 500 F3S-TGR-SB2-K2C-500(MTL)*
3 400 F3S-TGR-SB2-K3C-800(MTL)*
4 300 F3S-TGR-SB2-K4C-900(MTL)*
*. If you want to have a ONE WAY direction Type, (see Page D-26) Please add the MTL behind of Model Name. Ex. F3S-TGR-SB4-K2C-500MTL
F3S-TGR-SB4-K@C Mirror Reflection Type (Type 4)
Shape Number of optical
axes
2 500 F3S-TGR-SB4-K2C-500(MTL)*
3 400 F3S-TGR-SB4-K3C-800(MTL)*
4 300 F3S-TGR-SB4-K4C-900(MTL)*
*. If you want to have a ONE WAY direction Type, (see Page D-26) Please add the MTL behind of Model Name. Ex. F3S-TGR-SB4-K2C-500MTL
Sensing Distance Beam
Pitch
0.5 to 6 m
0.5 to 5 m
Sensing Distance Beam
Pitch
0.5 to 6 m
0.5 to 5 m
Model
Model
Muting Connecting Box (Order Separately)
Flexible Connecting Box
Appearance SLC Connection
Type
M12 8pin connector without cable
4 x Muting sensor connection (4pin) 1 x Muting Lamp M12 (4pin) 1 x Override/Test input M12 (4pin)
1 x cabinet connection M12 (8pin) M12 8pin connector with 100 mm cable
Other connection Model
F39-TGR-SB-CMB1
F39-TGR-SB-CMB2
Accessories (Order Separately)
Connector Cable
Appearance Cable length Specification Model
2 m
5 m F39-TGR-SB4-CVLB5R
10 m F39-TGR-SB4-CVLB10R
M12 connector (8pin Socket)
For cabinet connection
(From F3S-TGR-SB@-K@C or F3S-TGR-
SB-CMB@)
F39-TGR-SB4-CVLB2R
F3S-TGR
2 m
M12 connector (4pin Plug)
For Muting sensor, Muting Lamp connec-
tion and Override/Test connection
F39-TGR-SB4-CVLB2MC
G-51F3S-TGR-SB@C series
Page 4
Connector Plug Assemblies, Screw-on Type
Appearance Cable connection
direction
Specification Connection
method
Applicable cable
diameter
Model
Straight
DC only 4pin Plug Screw-on 3 dia. (3 to 4 dia.)
Right angle XS2G-D4S6
Muting Lamp
Appearance Specification Model
24 V DC F39-A11
Bulb for Maintenance
Appearance Specification Model
24 V DC 3 W E14 F39-A11MB
Laser alignment Kit
Appearance Model
F39-LKK2-SB
XS2G-D4S5
G-52 Safety Sensors / Components
Page 5
Rating and Performance
Safety sensors
F3S-TGR-SB@-K@C
Item Model
F3S-TGR-SB4-K@C-@@@(MTL)*
Sensor type Type 4 Type 2 Applicable safety category 4, 3, 2, 1, B 2, 1, B Operating range F3S-TGR-SB@-K2C 0.5 - 6 m
F3S-TGR-SB@-K3C/K4C 0.5 - 6 m
Beam pitch and Number of beam F3S-TGR-SB@-K2C 500 mm 2 beam with mirror
F3S-TGR-SB@-K3C 400 mm 3 beam with mirror
F3S-TGR-SB@-K4C 300 mm 4 beam with mirror
Outermost beam gap F3S-TGR-SB@-K2C 500 mm
F3S-TGR-SB@-K3C 800 mm
F3S-TGR-SB@-K4C 900 mm
Effective aperture angle (EAA) Within ±2.5° Within ±5° Light source Infrared LED (880 nm) Power supply 24 VDC ± 20% Current Consumption 420 mA OSSD Two PNP transistor outputs, 250 mA each. (500 mA sum) Output operation mode Light - ON Test functions Self-test (after power ON and during operation, one cycle during response time) Protection Output short-circuit protection, Reverse Polarity protection Response time ON to OFF 16ms max
OFF to ON 300 ms (Maximum Power-ON time is 900 ms)
Ambient temperature Operating: -10 to +55 °C (with no dew condensation) Ambient humidity 15% to 95% (non condensing) Metal housing (Al) painted Yellow (RAL 1303 F14) Degree of protection IP65 Accessories M6 T-Bolt x 8, M6 Nut x 8
Mounting fixture x 4
Applicable standards EN61496-1; 1997
prEN61496-2; 1997
*. If you want to have a ONE WAY direction Type, (see Page D-26) Please add the MTL behind of Model Name. Ex. F3S-TGR-SB4-K2C-500MTL
F3S-TGR-SB2-K@C-@@@(MTL)*
Muting Connecting Box
F3S-TGR-SB-CMB@
Item Model F39-TGR-SB-CMB@
Power supply 24 VDC ± 20% Consumption 10 W max Ambient temperature During operation: -10 to +55 °C (with no dex condensation) Ambient humidity 15% to 95% (non condensing) RX connector M12 8 pins female Cabinet connector M12 8 pins male Sensor connector 4 x M12 4 pins female Muting indicator M12 4 pins female Test / Override connectors M12 4 pins female Metal housing (Al) painted Yellow (RAL 1303 F14) Degree of protection IP65 Material Case Aluminium
Connector Brass with nickel plate
Front Cover Aluminium Weight 0.5 kg Accessories M6 T-Bolt x 4, M6 Nut x 4
Mounting fixture x 2, Connector cover x 2
F3S-TGR
G-53F3S-TGR-SB@C series
Page 6
Item Model F39-TGR-SB-CMB@
Applicable standards 93/68/EEC
DIN V VDE 0801:1990 and am.A1:1994 EN 50081-2:1993 EN 55022:1998
Dimensions
F3S-TGR-SB-K@C-@@@ with Mounting Brackets
47.5 37.7
A
35
73 C, E
13
Model A C E
F3S-TGR-SB@-K2C500 614 mm 500 mm 500 mm F3S-TGR-SB@-K3C800 914 mm 800 mm 400 mm F3S-TGR-SB@-K4C900 1,014 mm 900 mm 300 mm
G-54 Safety Sensors / Components
Page 7
F39-TGR-SB-CMB1
Muting connection box Mounting bracket (Common bracket for F3S-TGR-SB@-K@C
and F39-TGR-SB-CMB@
Connector Plug Assemblies, Screw-on Type
XS2G-D4S5
M12 x 1
14.9 dia.
20 dia.
XS2G-D4S6
M12 x 1
14.9 dia.20 dia.
58.7
14 dia.
39.7
39.6
F3S-TGR
14 dia.
G-55F3S-TGR-SB@C series
Page 8
Connection
F3S-TGR-SB@-K@C
Connection example
When using Muting function
Passive side
White
S1
Brown
Green
Active side
Pink
Yellow
Gray
Blue
Red
Shield
Green
MIA
Yellow
MIB
Pink
OSSD1
White
Brown
S1
S1: External Test / Interlock reset Switch
OSSD1
+24Vdc
OSSD2
0Vdc
MIA : Muting input A
MIB : Muting input B
ML : Muting Lamp
In case of Cat 4 (EN954-1), OSSD1/2 must be connected Safety Relay Unit (G9SA, G9SB-301B etc.) with feedback monitor
Pin reference
Front View Pin No. Signal Name Wire Color
1 Test and Reset Input White 2+24Vdc Brown
1
2
8
3
7
4
6
5
3 Muting A Input Green 4 Muting B Input Yellow 5 OSSD1 (OUT1) Gray 6 OSSD2 (OUT2) Pink 70Vdc Blue 8 Muting Lamp (0 Vdc) Red
Gray
OSSD2
Blue
Red
ML
Shield
+24Vdc
0Vdc
G-56 Safety Sensors / Components
Page 9
F3S-TGR-SB-CMB@
Pin and Plug reference 1) To F3S-TGR-SB Series
1) To Barrier (F3S-TGR-SB series) M12 8pin connector (Female)
2) Muting Sensor B2 M12 5pin connector (Female)
3) Muting Sensor A2 M12 5pin connector (Female)
4) Muting Sensor B1 M12 5pin connector (Female)
5) Muting Sensor A1 M12 5pin connector (Female)
6) Muting Lamp M12 5pin connector (Female)
7) Test/Override M12 5pin connector (Female)
8) From Cabinet M12 8pin connector (Male)
*1 In case of F3S-TGR-SB-CMB2,
M12 8pin connector with 100 mm cable
*1
Front View Pin No. Signal Name Wire Color
1 Test and Reset Input White 2+24Vdc Brown 3 Muting A Input Green
1
2
3
7
8
4
6
5
4 Muting B Input Yellow 5 OSSD1 (OUT1) Gray 6 OSSD2 (OUT2) Pink 70Vdc Blue 8 Muting Lamp (0 Vdc) Red
2), 3) 4), 5) Wiring of Muting Sensor connection
Front View Pin No. Signal Name Wire Color
1+24Vdc Brown
2
1
5
4
3
2 No connect White 30V Blue 4 PNP Input Black
6) Wiring of Muting Lamp connection
Front View Pin No. Signal Name Wire Color
1+24Vdc Brown
2
1
5
4
3
2 No connect White 3 No connect Blue 40V Black
7) Test/Override connection
Front View Pin No. Signal Name Wire Color
1+24Vdc Brown
2
1
5
4
3
2 Test input White 3 No connect Blue 4 Override input Black
8) From Cabinet
Front View Pin No. Signal Name Wire Color
1 Test and Reset Input White 2+24Vdc Brown
1
2
8
3
7
4
6
5
3 Muting A Input Green 4 Muting B Input Yellow 5 OSSD1 (OUT1) Gray 6 OSSD2 (OUT2) Pink 70Vdc Blue 8 Muting Lamp (0 Vdc) Red
F3S-TGR
G-57F3S-TGR-SB@C series
Page 10
Application
Manual Reset Mode (by Safety barrier)
F3S-TGR-SB4-K2C / F39-TGR-SB-CMB@ / G9SB-200-B or 301-B
Passive side Active side
F3S-TGR-SB@-K@C
Muting sensor B2
Muting sensor A2
DIP switch Status of F3S-TGR-SB@-K@C
1 2 3 4
ON
1 2 3 4
ON
+24VDC
0VDC
F39-TGR-SB-CMB@
BROWN (+24VDC)
BLUE (0VDC)
SHIELD
Muting sensor B1
Manual Reset Mode:
Every DIP SW has to be OFF status
Muting sensor A1
Factory setting:
Auto Reset Mode (Sw No 4 is ON)
Muting Lamp
Override Switch
Test / Reset Switch
KM1 b
GRAY (OSSD 1)
PINK (OSSD 2)
KM2 b
F39-TGR-SB-CMB@ Plug reference
Muting Sensor (B2/A2/B1/A1)
4 3
5
1
Black
Blue
Brown
2
PNP OUT
0Vdc
+24Vdc
Muti ng Sen sor
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. E19E-EN-01
In the interest of product improvement, specifications are subject to change without notice.
G-58 Safety Sensors / Components
G9SB-301-B
Muting Lamp
4 3
1
5
2
KM1 KM2
Black(0Vdc)
Brown(+24Vdc)
Muting Lamp
Test and Ov erride inputs
Black(Override (N.O))
4 3
5
1
2
White(Test/Reset (N.C))
Brown(Common)
Loading...