OPERATION MANUAL
Page 3
Manufacturer: OMRON Europe B.V.
Wegalaan 67-69 2132 JD Hoofddorp, THE NETHERLANDS WWW www.industrial.omron.eu
User‘s Manual: Version 0.2 dated 18-10-2011
Page 4
Precautions
WARNING
The F3ET2 multi-beam photoelectric sensor with beam evaluation function is not a safety component for ensuring the safety of people which is defined in EC directive (2006/42/EC) or by any other regulations or standards.
GENERAL INFORMATION
The instructions in this manual must be followed in order to safeguard correct installation. The barrier does not contain any parts that are subject to maintenance; do not remove any electronic parts from the housing for any reason. In case of malfunction, please contact your sales representative with a description of the failure found and its period of operation. Do not touch the front protective cover with your hands as dust and/or grease may decrease performance.
Precautions
OPERATING ENVIRONMENT
Do not use the light curtain in locations with explosive or flammable gas. Make sure that the product is operated in accordance with IP65 standards. Do not subject the light curtain to excessive shock when mounting. When using the light curtain in the vicinity of an inverter motor, be sure to connect the protective earth ground wire of the motor to earth. Failure to ground the motor may result in malfunction of the light curtain. Further it is recommended to use shielded cables and to connect the shield to the ground in such cases.
CLEANING
When cleaning the front covers please do not use woollen cloths or organic solvents. The interval between cleaning depends on conditions in the environment (dust, fog).
POWER SUPPLY VOLTAGE AND OUTPUT LOAD
Do not connect an AC power supply to the Sensor. If AC power (100 VAC or more) is supplied to the Sensor, it may explode or burn. Make sure that the power supply to the Sensor is within the rated voltage range. If a voltage exceeding the rated voltage range is supplied to the Sensor, it may explode or burn.
F3ET2 LIGHT CURTAINS OPERATION MANUAL
1
Page 5
Page 6
Table Of Contents
Precautions ........................................................................................... 1
Chapter 1 Overview
Chapter 2 Installation
2-1 General...................................................................................................2-2
2-2 Mechanical installation ...........................................................................2-3
2-3 Operating environment ...........................................................................2-4
2-4 Operating distances................................................................................2-4
2-5 Wiring & output circuit.............................................................................2-5
2-6 Setting the internal selector-switches .....................................................2-6
Chapter 3 Order codes
Chapter 4 Technical specifications
4-1 Ratings ...................................................................................................4-2
Chapter 5 LED indicators and error indication
5-1 LED indication on receiver unit...............................................................5-2
5-2 LED indication on emitter unit.................................................................5-3
5-3 Troubleshooting for error indication........................................................5-4
Chapter 6 Dimensions
Chapter 7 Accessories
7-1 Mounting bracket ....................................................................................7-2
7-2 Cables ....................................................................................................7-2
Manual Revision History .............................................................................. 1
F3ET2 LIGHT CURTAINS OPERATION MANUAL
3
Page 7
4
Page 8
Overview
F3ET2 is a multi-beam light curtain for easy area detection for various applications. Due to its robust housing F3ET2 is also suitable for hash environments in industrial automation.
F3ET2 is provided with PNP and NPN transistor output.
F3ET2 is available in two resolutions:
Model Sensing distance Pitch resolution Min. detectable object
F3ET2-005-[…] 0 to 3 m 5 mm 10 mm
F3ET2-018-[…] 0 to 15 m 18 mm 30 mm
Models with 7.5 mm resolution are available upon request.
Due to its modular design F3ET2 can be provided in various sizes. For standard sizes please refer to model list in chapter 3.
1
F3ET2 LIGHT CURTAINS OPERATION MANUAL
Page 9
Page 10
Installation
2-1 General ..........................................................................2-2
2-2 Mechanical installation ................................................2-3
Mounting accessories ..................................................................... 2-3
Additional mounting rigidity ............................................................. 2-3
Mechanical Mounting ...................................................................... 2-4
2-3 Operating environment ................................................2-4
2-4 Operating distances .....................................................2-4
2-5 Wiring & output circuit .................................................2-5
2-6 Setting the internal selector-switches........................2-6
2
F3ET2 LIGHT CURTAINS OPERATION MANUAL
Page 11
2-1 General
2-1 General
The light curtain consists of one bar with light emitting optical elements and of one with receiving optical elements. The photosensitive elements are scanned in sequence, thus broken rays are detected.
F3ET2 features optical synchronisation and does not require synchronization wire between transmitter and receiver. The sync-function is provided by the upper beam located on the opposite side of the connector (see illustration below). During operation this beam must always be kept free. Otherwise it will result in a longer response frequency of the light curtain.
1st BEAM
2
Installation
D
L
L: Maximum detection area D: System resolution
2-2
F3ET2 LIGHT CURTAINS OPERATION MANUAL
Page 12
2-2 Mechanical installation
ID Description
1 movable M6 bolt
2 fixing braket
3 M6 washer
4 M6 Grower
5M6 nut
Mounting accessories
The F3ET2 system is mechanically installed by using the T-slots on the two sides or the back­side of the housing. Use the movable bolts, washers, growers and nuts to fix the mounting brackets as shown in the picture
2-2 Mechanical installation
2
Note: Shipment contains different quantity of brackets, depending on the length of the LC. Longer LC
contains a higher number of brackets, following the rule of every 400 mm one bracket.
Additional mounting rigidity
It is recommended that the distance between the mounting brackets is 400 mm or less for optimum performance of the F3ET2 system.
Installation
F3ET2 LIGHT CURTAINS OPERATION MANUAL
2-3
Page 13
2-3 Operating environment
OK NG NG
Mechanical Mounting
Please mount the light curtains in proper alignment as shown in the pictures below by using the brackets provided with the light curtains.
2
2-3 Operating environment
Installation
If F3ET2 is installed at long distances the laser alignment aid F39-TGR-LLK2-CL provides a visible laser spot for simplified installation. If several light curtains are installed close to each other, interference of the light curtains must be avoided. In this case the assembly should be carried out as follows:
TX TXRXRX
The area for the installation of the light curtain must be suitable according to the technical specifications. The temperature of the environment, interference caused by electromagnetic disturbance and ambient light must be considered. Please contact the manufacturer for any information not contained in this manual.
2-4 Operating distances
The operating distances, which are given in the technical specifications, are guaranteed values for reliable operation. Operating F3ET2 above the specified sensing distance may cause greater sensitivity to vibration and possible electromagnetic disturbances.
If the F3ET2 is operated in a distance <1m, the sensitivity can be set to NEAR operation by dip-switch setting at transmitter (see ’ DIP switch setting’ on page 2-7). This should be considered for following application conditions:
a) Multiple light curtains are installed close to each other (avoiding mutual interference) b) Detection of small or semi-transparent objects
If none of above mentioned cases applies, FAR setting should be kept in order to provide maximum detection reliability.
2-4
F3ET2 LIGHT CURTAINS OPERATION MANUAL
Page 14
2-5 Wiring & output circuit
Variable
Power Supply
RECEIVER
Earth
Ground +24 VDC 0 VDC
Br Wh BL Bk Gr
EMITTER
Br Wh Bl Bk
Please connect the light curtain as described below:
2-5 Wiring & output circuit
2
Connector PIN assignment - Receiver
Type Internal wiring Pin Colour Signal name
M12 n5 pole
Connector PIN assignment - Transmitter
Type Internal wiring Pin Colour Signal name
M12 n4 pole
1Brown +Vs
2 White not used
3Blue 0V
4 Black PNP/NPN output
5 Gray not used
1Brown+Vs
2 White not used
3Blue 0V
4 Black Not used
Installation
F3ET2 LIGHT CURTAINS OPERATION MANUAL
2-5
Page 15
2
Precautions for Correct Use
1 2 3 4 5 6 7 8
OFF
ON
1 2 3 4 5 6 7 8
OFF
ON
2-6 Setting the internal selector-switches
2-6 Setting the internal selector-
switches
All the operations listed below must only be carried out when the receiver is disconnected to the power supply.
L-ON/D-ON setting and distance setting can be changed by selector switches. To access the selector switches unscrew the end cap of the receiver and transmitter unit:
Installation
There are two lines of dip switches in each transmitter and receiver. The settings must be done for both lines. Change the setting of the dip-switch and close the cap again. The light
curtain can now be reconnected to the power supply.
2-6
F3ET2 LIGHT CURTAINS OPERATION MANUAL
Page 16
DIP switch setting
Transmitter:
Dip-SW Status Function
2-6 Setting the internal selector-switches
1
2
3
4
5
6
7
8
Receiver:
OFF Not USED
ON Not USED
OFF Not USED
ON Not USED
OFF Not USED
ON Not USED
OFF Not USED
ON Not USED
OFF FAR (Default)
ON NEAR
OFF Not USED
ON Not USED
OFF Not USED
ON Not USED
OFF Not USED
ON Not USED
2
Installation
Dip-SW Status Function
1
2
3
4
5
6
7
8
OFF Not USED
ON Not USED
OFF PNP type (default)
ON NPN type
OFF Dark on (default)
ON Light on
OFF Not USED
ON Not USED
OFF Not USED
ON Not USED
OFF Not USED
ON Not USED
OFF Not USED
ON Not USED
OFF Not USED
ON Not USED
There are two lines of dip switches in each transmitter and receiver. The settings must be done for both lines.
F3ET2 LIGHT CURTAINS OPERATION MANUAL
2-7
Page 17
Page 18
Order codes
3
F3ET2 LIGHT CURTAINS OPERATION MANUAL
Page 19
3
Order code
F3ET2-005-150
F3ET2-018-150 18 mm 15 m 8
F3ET2-005-300
F3ET2-018-300 18 mm 15 m 16
F3ET2-005-450
F3ET2-018-450 18 mm 15 m 24
F3ET2-005-600
F3ET2-018-600 18 mm 15 m 32
F3ET2-005-900
F3ET2-018-900 18 mm 15 m 48
F3ET2-005-1200
F3ET2-018-1200 18 mm 15 m 64
F3ET2-005-1500
F3ET2-018-1500 18 mm 15 m 80
F3ET2-005-1800
F3ET2-018-1800 18 mm 15 m 96
F3ET2-018-2100 2100 18 mm 15 m 112
Measurement
range
150
300
450
600
900
1200
1500
1800
Pitch
5mm 3 m 30
5mm 3 m 60
5mm 3 m 90
5 mm 3 m 120
5 mm 3 m 180
5 mm 3 m 240
5 mm 3 m 300
5 mm 3 m 360
*1
Sensing distance
Channels
*1. Models with other dimensions and 7.5 mm pitch are available. Please con-
tact your OMRON representative.
Order codes
3-2
F3ET2 LIGHT CURTAINS OPERATION MANUAL
Page 20
Technical specifications
4-1 Ratings...........................................................................4-2
4
F3ET2 LIGHT CURTAINS OPERATION MANUAL
Page 21
4-1 Ratings
4-1 Ratings
Models F3ET2-005-… F3ET2-018-…
Operating distance 3 m 15 m
Light source (wave length) Infrared (880 nm)
Pitch 5.3 mm 18.3 mm
Operation temperature –10° to +55°C
Storage temperature –10° to +75°C
Degree of protection IP65 (IEC 60529)
Operating voltage 24 VDC ±20%
Current consumption 150 mA max (excluded load on digital)
Power-on delay <1 s
Response time 4 ms + 80 µs x number of beams
Outputs PNP / NPN transistor output, 200 mA
Protective circuits Reverse polarity protection, output short-circuit protection
Insulation resistance >20 M
Dielectric voltage strength 350 VAC (1 min)
Configuration By dip-switches
4
Housing material Aluminum
Front Window Material Acrylic Lexan
End Cap and Connector ABS
Sealing Gasket Material EPDM
Technical specifications
4-2
F3ET2 LIGHT CURTAINS OPERATION MANUAL
Page 22
LED indicators and error indication
5-1 LED indication on receiver unit...................................5-2
5-2 LED indication on emitter unit.....................................5-3
5-3 Troubleshooting for error indication ..........................5-4
5
F3ET2 LIGHT CURTAINS OPERATION MANUAL
Page 23
5-1 LED indication on receiver unit
POWER
RUN
FREE
BREAK
STATUS
RX
Meaning of symbols
SYMBOL MEANING
Diagnosis LED off
Diagnosis LED on
Diagnosis LED blinking
5-1 LED indication on receiver unit
Status of Receiver is displayed by 5 LEDs:
Disposition of indicator Name of indicator Colour
POWER Green
RUN Yellow
FREE Green
BREAK Red
STATUS Yellow
5
Normal operation indication on receiver:
LED signal pattern Description
LED error indication on receiver:
ID LED signal pattern Description
1 Short on PNP/NPN output
2
3
4
5
LED indicators and error indication
No object in field. Running ok
Object in field. Running ok
Correct alignment reached
Low supply voltage
Error on microcontroller
Error on optical system
Wrong dip switch configuration
5-2
F3ET2 LIGHT CURTAINS OPERATION MANUAL
Page 24
5-2 LED indication on emitter unit
POWER
STATUS 1
RANGE
STATUS 2
TX
5-2 LED indication on emitter unit
Status of Receiver is displayed by 5 LEDs:
Disposition of indicator Name of indicator Colour
POWER Green
STATUS 1 Yellow
RANGE Green
Not used Red
STATUS 2 Yellow
Normal operation indication on emitter:
LED signal pattern Description
Emitter working, short range selected.
Emitter working, long range selected.
LED error indication on emitter:
ID LED signal pattern Description
2
3
4
5
Low supply voltage
Error on microcontroller
Error on optical system
Wrong dip switch configuration
5
LED indicators and error indication
F3ET2 LIGHT CURTAINS OPERATION MANUAL
5-3
Page 25
5-3 Troubleshooting for error indication
5-3 Troubleshooting for error
indication
ID Actions
1 Check the presence of shorts on the outputs, check the correct connection of outputs
2 Check if power supply is within specification of 24Vdc ± 20%
3 Turn the unit ON and OFF again. If the error persist, please contact manufacturer
4 Turn the unit ON and OFF again. If the error persist, please contact manufacturer
5 Check the setting of switches
5
LED indicators and error indication
5-4
F3ET2 LIGHT CURTAINS OPERATION MANUAL
Page 26
Dimensions
6
F3ET2 LIGHT CURTAINS OPERATION MANUAL
Page 27
L: Total length
E: Detection zone
A: Dead zone without detection capability
E
6
Dimensions
L
A
All dimensions shown are in mm
Item number Detection Zone E (mm) Total length L (mm)
F3ET2-005-150 159 218
F3ET2-018-150 147 217
F3ET2-005-300 318 277
F3ET2-018-300 294 364
F3ET2-005-450 477 536
F3ET2-018-450 441 511
F3ET2-005-600 636 695
F3ET2-018-600 588 658
22.75
37
4.5
10.5
48
6.5
6-2
F3ET2-005-900 954 1013
F3ET2-018-900 882 952
F3ET2-005-1200 1272 1331
F3ET2-018-1200 1176 1246
F3ET2-005-1500 1590 1649
F3ET2-018-1500 1470 1540
F3ET2-005-1800 1908 1967
F3ET2-018-1800 1764 1834
F3ET2-018-2100 2058 2128
F3ET2 LIGHT CURTAINS OPERATION MANUAL
Page 28
Accessories
7-1 Mounting bracket..........................................................7-2
7-2 Cables............................................................................7-2
7
F3ET2 LIGHT CURTAINS OPERATION MANUAL
Page 29
7-1 Mounting bracket
7-1 Mounting bracket
(provided with the product)
7
Accessories
7-2 Cables
M12-5pin (straight)
M12-5pin (angled)
For other accessories like alignment kit, special brackets or connector cables please contact your sales representative.
Order Code Length
XS2F-M12PVC5S2M 2 m
XS2F-M12PVC5S5M 5 m
XS2F-M12PVC5A2M 2 m
XS2F-M12PVC5A5M 5 m
7-2
F3ET2 LIGHT CURTAINS OPERATION MANUAL
Page 30
Manual Revision History
The manual revision symbol is an alphabet appended at the end of the manual number found in the bottom left-hand corner of the front or back cover.
Example
E79E-EN-01
Revision symbol
Revision symbol
01 January 2012 First Print.
Revision date Description of revision and revised page
F3ET2 LIGHT CURTAINS OPERATION MANUAL
1
Page 31
Below is a list of articles with direct links to our shop Electric Automation Network where you
Buy on EAN
Buy on EAN
Buy on EAN
Buy on EAN
Buy on EAN
Buy on EAN
Buy on EAN
Buy on EAN
Buy on EAN
Buy on EAN
Buy on EAN
Buy on EAN
Buy on EAN
Buy on EAN
can see:
• Quote per purchase volume in real time.
• Online documentation and datasheets of all products.
• Estimated delivery time enquiry in real time.
• Logistics systems for the shipment of materials almost anywhere in the world.
• Purchasing management, order record and tracking of shipments.
To access the product, click on the green button.
Product Code Reference Product link
Photoelectric sensor, Height 1500mm 15m 18mm Digital output beams Sep.
Photoelectric sensor, Height 1500mm 5mm 3m Digital output beams Sep.
Photoelectric sensor, Height 450mm 5mm 3m Digital output beams Sep.
Photoelectric sensor, Height 600mm 18mm 15m Digital output beams Sep.
Photoelectric sensor, Height 600mm 5mm 3m Digital output beams Sep.
Photoelectric sensor, Height 900mm 18mm 15m Digital output beams Sep.
Photoelectric sensor, Height 900mm 5mm 3m Digital output beams Sep.
Photoelectric sensor, Height 1200mm 15m 18mm Digital output beams Sep.
Photoelectric sensor, Height 450mm 18mm 15m Digital output beams Sep.
Photoelectric sensor, Height 2100mm 15m 18mm Digital output beams Sep.
365869 F3ET2-018-1500
365868 F3ET2-005-1500
365860 F3ET2-005-450
365863 F3ET2-018-600
365862 F3ET2-005-600
365865 F3ET2-018-900
365864 F3ET2-005-900
365867 F3ET2-018-1200
365861 F3ET2-018-450
365872 F3ET2-018-2100
Photoelectric sensor, Height 1800mm 5mm 3m Digital output beams Sep.
Photoelectric sensor, Height 1800mm 15m 18mm Digital output beams Sep.
Photoelectric sensor, Height 150mm 5mm 3m Digital output beams Sep.
Photoelectric sensor, Height 150mm 18mm 15m Digital output beams Sep.
365870 F3ET2-005-1800
365871 F3ET2-018-1800
365856 F3ET2-005-150
365857 F3ET2-018-150
Page 32
Photoelectric sensor, Height 300mm 5mm 3m Digital
Buy on EAN
Buy on EAN
output beams Sep.
365858 F3ET2-005-300
Photoelectric sensor, Height 300mm 18mm 15m Digital output beams Sep.
365859 F3ET2-018-300