At the end of this document you will find links to products related to this catalog. You can go directly to our shop by
clicking HERE. HERE
Page 2
Cat. No. E79E-EN-01
ZX-T Series
F3ET2
Detection Light Curtain
OPERATION MANUAL
Page 3
Manufacturer:OMRON Europe B.V.
Wegalaan 67-69
2132 JD Hoofddorp, THE NETHERLANDS
WWWwww.industrial.omron.eu
User‘s Manual:Version 0.2 dated 18-10-2011
Page 4
Precautions
WARNING
The F3ET2 multi-beam photoelectric sensor with beam evaluation function is not a safety
component for ensuring the safety of people which is defined in EC directive (2006/42/EC) or
by any other regulations or standards.
GENERAL INFORMATION
The instructions in this manual must be followed in order to safeguard correct installation. The
barrier does not contain any parts that are subject to maintenance; do not remove any
electronic parts from the housing for any reason. In case of malfunction, please contact your
sales representative with a description of the failure found and its period of operation. Do not
touch the front protective cover with your hands as dust and/or grease may decrease
performance.
Precautions
OPERATING ENVIRONMENT
Do not use the light curtain in locations with explosive or flammable gas. Make sure that the
product is operated in accordance with IP65 standards. Do not subject the light curtain to
excessive shock when mounting. When using the light curtain in the vicinity of an inverter
motor, be sure to connect the protective earth ground wire of the motor to earth. Failure to
ground the motor may result in malfunction of the light curtain. Further it is recommended to
use shielded cables and to connect the shield to the ground in such cases.
CLEANING
When cleaning the front covers please do not use woollen cloths or organic solvents. The
interval between cleaning depends on conditions in the environment (dust, fog).
POWER SUPPLY VOLTAGE AND OUTPUT LOAD
Do not connect an AC power supply to the Sensor. If AC power (100 VAC or more) is supplied
to the Sensor, it may explode or burn. Make sure that the power supply to the Sensor is within
the rated voltage range. If a voltage exceeding the rated voltage range is supplied to the
Sensor, it may explode or burn.
Manual Revision History .............................................................................. 1
F3ET2 LIGHT CURTAINS OPERATION MANUAL
3
Page 7
4
Page 8
Overview
F3ET2 is a multi-beam light curtain for easy area detection for various applications. Due to its
robust housing F3ET2 is also suitable for hash environments in industrial automation.
F3ET2 is provided with PNP and NPN transistor output.
2-6Setting the internal selector-switches........................2-6
2
F3ET2 LIGHT CURTAINS OPERATION MANUAL
Page 11
2-1 General
2-1General
The light curtain consists of one bar with light emitting optical elements and of one with
receiving optical elements. The photosensitive elements are scanned in sequence, thus
broken rays are detected.
F3ET2 features optical synchronisation and does not require synchronization wire between
transmitter and receiver. The sync-function is provided by the upper beam located on the
opposite side of the connector (see illustration below). During operation this beam must always
be kept free. Otherwise it will result in a longer response frequency of the light curtain.
1st BEAM
2
Installation
D
L
L: Maximum detection area
D: System resolution
2-2
F3ET2 LIGHT CURTAINS OPERATION MANUAL
Page 12
2-2Mechanical installation
IDDescription
1movable M6 bolt
2fixing braket
3M6 washer
4M6 Grower
5M6 nut
Mounting accessories
The F3ET2 system is mechanically installed by using the T-slots on the two sides or the backside of the housing.
Use the movable bolts, washers, growers and nuts to fix the mounting brackets as shown in
the picture
2-2 Mechanical installation
2
Note: Shipment contains different quantity of brackets, depending on the length of the LC. Longer LC
contains a higher number of brackets, following the rule of every 400 mm one bracket.
Additional mounting rigidity
It is recommended that the distance between the mounting brackets is 400 mm or less for
optimum performance of the F3ET2 system.
Installation
F3ET2 LIGHT CURTAINS OPERATION MANUAL
2-3
Page 13
2-3 Operating environment
OKNGNG
Mechanical Mounting
Please mount the light curtains in proper alignment as shown in the pictures below by using
the brackets provided with the light curtains.
2
2-3Operating environment
Installation
If F3ET2 is installed at long distances the laser alignment aid F39-TGR-LLK2-CL provides a
visible laser spot for simplified installation.
If several light curtains are installed close to each other, interference of the light curtains must
be avoided. In this case the assembly should be carried out as follows:
TXTXRXRX
The area for the installation of the light curtain must be suitable according to the technical
specifications. The temperature of the environment, interference caused by electromagnetic
disturbance and ambient light must be considered. Please contact the manufacturer for any
information not contained in this manual.
2-4Operating distances
The operating distances, which are given in the technical specifications, are guaranteed values
for reliable operation. Operating F3ET2 above the specified sensing distance may cause
greater sensitivity to vibration and possible electromagnetic disturbances.
If the F3ET2 is operated in a distance <1m, the sensitivity can be set to NEAR operation by
dip-switch setting at transmitter (see ’ DIP switch setting’ on page 2-7).
This should be considered for following application conditions:
a) Multiple light curtains are installed close to each other (avoiding mutual interference)
b) Detection of small or semi-transparent objects
If none of above mentioned cases applies, FAR setting should be kept in order to provide
maximum detection reliability.
2-4
F3ET2 LIGHT CURTAINS OPERATION MANUAL
Page 14
2-5Wiring & output circuit
Variable
Power Supply
RECEIVER
Earth
Ground +24 VDC 0 VDC
BrWhBLBkGr
EMITTER
BrWhBlBk
Please connect the light curtain as described below:
2-5 Wiring & output circuit
2
Connector PIN assignment - Receiver
TypeInternal wiringPinColourSignal name
M12 n5 pole
Connector PIN assignment - Transmitter
TypeInternal wiringPinColourSignal name
M12 n4 pole
1Brown+Vs
2Whitenot used
3Blue0V
4BlackPNP/NPN output
5Graynot used
1Brown+Vs
2Whitenot used
3Blue0V
4BlackNot used
Installation
F3ET2 LIGHT CURTAINS OPERATION MANUAL
2-5
Page 15
2
Precautions for Correct Use
1 2 3 4 5 6 7 8
OFF
ON
1 2 3 4 5 6 7 8
OFF
ON
2-6 Setting the internal selector-switches
2-6Setting the internal selector-
switches
All the operations listed below must only be carried out when the receiver is disconnected to
the power supply.
L-ON/D-ON setting and distance setting can be changed by selector switches.
To access the selector switches unscrew the end cap of the receiver and transmitter unit:
Installation
There are two lines of dip switches in each transmitter and receiver. The settings must
be done for both lines. Change the setting of the dip-switch and close the cap again. The light
curtain can now be reconnected to the power supply.
2-6
F3ET2 LIGHT CURTAINS OPERATION MANUAL
Page 16
DIP switch setting
Transmitter:
Dip-SWStatusFunction
2-6 Setting the internal selector-switches
1
2
3
4
5
6
7
8
Receiver:
OFFNot USED
ONNot USED
OFFNot USED
ONNot USED
OFFNot USED
ONNot USED
OFFNot USED
ONNot USED
OFFFAR (Default)
ONNEAR
OFFNot USED
ONNot USED
OFFNot USED
ONNot USED
OFFNot USED
ONNot USED
2
Installation
Dip-SWStatusFunction
1
2
3
4
5
6
7
8
OFFNot USED
ONNot USED
OFFPNP type (default)
ONNPN type
OFFDark on (default)
ONLight on
OFFNot USED
ONNot USED
OFFNot USED
ONNot USED
OFFNot USED
ONNot USED
OFFNot USED
ONNot USED
OFFNot USED
ONNot USED
There are two lines of dip switches in each transmitter and receiver. The settings must
be done for both lines.
F3ET2 LIGHT CURTAINS OPERATION MANUAL
2-7
Page 17
Page 18
Order codes
3
F3ET2 LIGHT CURTAINS OPERATION MANUAL
Page 19
3
Order code
F3ET2-005-150
F3ET2-018-15018 mm15 m8
F3ET2-005-300
F3ET2-018-30018 mm15 m16
F3ET2-005-450
F3ET2-018-45018 mm15 m24
F3ET2-005-600
F3ET2-018-60018 mm15 m32
F3ET2-005-900
F3ET2-018-90018 mm15 m48
F3ET2-005-1200
F3ET2-018-120018 mm15 m64
F3ET2-005-1500
F3ET2-018-150018 mm15 m80
F3ET2-005-1800
F3ET2-018-180018 mm15 m96
F3ET2-018-2100210018 mm15 m112
Measurement
range
150
300
450
600
900
1200
1500
1800
Pitch
5mm3 m30
5mm3 m60
5mm3 m90
5 mm3 m120
5 mm3 m180
5 mm3 m240
5 mm3 m300
5 mm3 m360
*1
Sensing
distance
Channels
*1. Models with other dimensions and 7.5 mm pitch are available. Please con-