Omron ELITE 7300W User Manual

Women’s Advanced
Automatic Blood Pressure Monitor
with Two Cuffs
Model Elite 7300W

INSTRUCTION MANUAL

ESPAÑOL
ENGLISH
2
Before Using the Monitor
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Operating the Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Care and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Before Taking a Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Operating Instructions
Know Your Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Unit Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Display Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Irregular Heartbeat Symbol ( ) . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Movement Error Symbol ( ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Heartbeat Symbol/Hypertension Indicator ( ) . . . . . . . . . . . . . . .12
Average Value Symbol ( ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Battery Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Setting the Date and Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Setting the Medication Reminder Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Applying the Arm Cuff . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Taking a Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
Using the Guest Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Using the Memory Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
Averaging Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
To Display the Measurement Values . . . . . . . . . . . . . . . . . . . . . . . . .31
To Delete All Values Stored in the Memory . . . . . . . . . . . . . . . . . . .33
Care and Maintenance
Care and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
Error Indicators and Troubleshooting Tips . . . . . . . . . . . . . . . . . . . . . . . . . .36
FCC Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40

TABLE OF CONTENTS

3
Thank you for purchasing the Omron®Elite 7300W IntelliSense
®
Women’s Advanced Automatic Blood Pressure Monitor.

INTRODUCTION

Fill in for future reference.
DATE PURCHASED: __________________ SERIAL NUMBER: ____________________
Staple your purchase receipt here
Your new digital blood pressure monitor uses the oscillometric method of blood pressure measurement. This means the monitor detects your blood’s movement through your brachial artery and converts the movements into a digital reading. An oscillometric monitor does not need a stethoscope so the monitor is simple to use.
The Elite 7300W comes with the following components:
• Monitor • Standard Arm Cuff • Large Arm Cuff
• 4 “AAA” Batteries • Stylish Zipper Case
• Instruction Manual printed in English and Spanish
• Quick Guide • Warranty Card • Cuff Guide The Elite 7300W IntelliSense
®
Women’s Advanced Automatic Blood
Pressure Monitor is intended for home use. While the Omron Elite 7300W is designed for women, it has also been
clinically proven accurate for all adults, regardless of gender. So you can be assured that this product can be used by men and women.
SAVE THESE INSTRUCTIONS
Before Using the Monitor
4
To assure the correct use of the product basic safety measures should always be followed including the warnings and cautions listed in this instruction manual.
WARNING
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL
CAUTION
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury to the user or patient or damage to the equipment or other property.
OPERATING THE DEVICE
Contact your physician for specific information about your blood pressure. Self-diagnosis and treatment using measured results may be dangerous. Follow the instructions of your physician or licensed healthcare provider.
If battery fluid should get in your eyes, immediately rinse with plenty of clean water. Contact a physician immediately.
People with severe blood flow problems, or blood disorders, should consult a doctor before using the unit. Cuff inflation can cause internal bleeding.
Read all of the information in the instruction manual and any other literature in the box before operating the unit.

SAFETY INFORMATION

OPERATING THE DEVICE (continued)
This device is intended for use in measuring blood pressure and pulse rate in the adult population. Do not use this device on infants or persons who cannot express their intentions.
Inflating to a higher pressure may result in bruising where the cuff is
applied.
Operate the device only as intended. Do not use the device for any other purpose.
Dispose of the device, components and optional accessories according to applicable local regulations. Unlawful disposal may cause environmental pollution.
Do not use a cellular phone near the device. It may result in an operational failure.
Use only Omron authorized parts and accessories. Parts and accessories not approved for use with the device may damage the unit.
Use only 1.5V alkaline batteries with this device. Do not use other types of batteries. This may damage the unit.
SAFETY INFORMATION
5
CARE AND MAINTENANCE
Do not subject the monitor to strong shocks, such as dropping the unit on the floor.
Do not submerge the device or any of the components in water.
Store the device and the components in a clean, safe location.
Changes or modification not approved by Omron Healthcare will void the user warranty. Do not disassemble or attempt to repair the unit or components.
SAFETY INFORMATION
6
7

BEFORE TAKING A MEASUREMENT

To ensure a reliable reading follow these recommendations:
1. Avoid eating, drinking alcohol, smoking, exercising, and bathing for 30 minutes before taking a measurement. Rest for at least 15 minutes before taking the measurement.
2. Stress raises blood pressure. Avoid taking measurements during stressful times.
3. Measurements should be taken in a quiet place.
4. Remove tight-fitting clothing from your arm.
5. Sit in a chair with your feet flat on the floor. Rest your arm on a table so that the cuff is at the same level as your heart.
6. Remain still and do not talk during the measurement.
7. Keep a record of your blood pressure and pulse readings for your physician. A single measurement may not provide an accurate indication of your true blood pressure. You need to take and record several readings over a period of time. Try to measure your blood pressure at about the same time each day for consistency.
8. Wait 2-3 minutes between measurements. The wait time allows the arteries to return to the condition prior to taking the blood pressure measurement. You may need to increase the wait time depending on your individual physiological characteristics.
8
KNOW YOUR UNIT
Main Unit:
Operating Instructions
Battery Compartment
Memory Button ( )
Display
Date/Time Setting Button ( )
Air Jack
Start/Stop Button
KNOW YOUR UNIT
9
Components:
Arm Cuffs
Air Tube
Air Plug (Connects to Air Jack)
Stylish Zipper Case
Four “AAA”Batteries
Instruction Manual
Quick Guide
Thank you for purchasing the Omron¤Elite 7300WIntelliSense
¤
Womens Advanced Automatic Blood Pressure Monitor. There are two cuffs included in this unit, standard size and large size. This sheet simply explains how to choose the correct size cuff with Cuff Guide. However, please read the instruction manual thoroughly before using the unit.
1. Make a loop with your Cuff Guide.
2. Fit the looped Cuff Guide on your upper arm.
3. Cuff Guide shows your correct cuff. Use the cuff with same colored sticker.
QUICK GUIDE
5318770-0A
Use the Cuff Guide to get your upper arm size, then choose the right size cuff.
(9"-13")
Use the Cuff Guide to get your upper arm size, then choose the right size cuff.
(13"-17")
Use the Standard Cuff
Use the Large Cuff
Orange
Purple
Cuff Guide
Standard Arm Cuff
Air Tube
Air Plug (Connects to Air Jack)
Large Arm Cuff
INSTRUCTION MANUAL
Women’s Advanced
Automatic Blood Pressure Monitor
with Two Cuffs
Model
Elite 7300W
ESPAÑOL
ENGLISH
10

UNIT DISPLAY

Movement Error Symbol
Low Battery Indicator
Deflation Symbol
Heartbeat Symbol/ Hypertension Indicator
Irregular Heartbeat Symbol
Average Value Symbol
Memory Symbol
Pulse Display
Medication Symbol
Date/Time Display
Guest Symbol
Systolic Blood Pressure
Diastolic Blood Pressure
11
IRREGULAR HEARTBEAT SYMBOL ()
When the monitor detects an irregular rhythm two or more times during the measurement, the Irregular Heartbeat Symbol ( ) will appear on the display with the measurement values.
An irregular heartbeat rhythm is defined as a rhythm that is more than 25% slower or 25% faster from the average rhythm detected while the monitor is measuring the systolic blood pressure and the diastolic blood pressure.
If the Irregular Heartbeat Symbol ( ) displays with your measurement results, we recommend you consult your physician. Follow the directions of your doctor.
MOVEMENT ERROR SYMBOL ()
The Movement Error Symbol () is displayed if you move your body during the measurement. Please remove the arm cuff, and wait 2-3 minutes. Take another measurement.
NNormal H
ormal H
ear
eartbtb
eat
eat
Irregular Heartbeat
Pulse
Blood
pressure
Pulse
Blood
pressure
Short Long

DISPLAY SYMBOLS

HEARTBEAT SYMBOL/HYPERTENSION INDICATOR ()
TAKING A MEASUREMENT
The Heartbeat Symbol ( ) flashes on the display during the measurement. The Heartbeat Symbol ( ) flashes at every heartbeat.
When the measurement is complete, the Heartbeat Symbol ( ) flashes on the display with your blood pressure and pulse rate if the reading is above 135 for the Systolic Blood Pressure value and/or 85 for the Diastolic Blood Pressure value.
USING THE MEMORY FUNCTION
The Heartbeat Symbol ( ) flashes when the blood pressure reading stored in the memory is above 135 for the Systolic Blood Pressure value and/or 85 for the Diastolic Blood Pressure value.
AVERAGE VALUE SYMBOL ()
The Average Value Symbol () is displayed when you press the Memory button ( ). The most recent average reading appears on the display screen.
DISPLAY SYMBOLS
12
The American Heart Association recommends the following guideline for upper limit of normal for home blood pressure readings:
AHA Home Guideline for UpperLimit of Normal BP
Systolic Blood Pressure 135 mmHg Diastolic Blood Pressure 85 mmHg This is a general guideline because blood pressure depends on
age and morbidity. The AHA recommends a lower home blood pressure goal for certain patients, including diabetic patients, pregnant women, and patients with renal failure
1
.
The monitor is not intended to be a diagnostic device.
WARNING
Contact your physician for specific information about your blood pressure. Self-diagnosis and treatment using measured results may be dangerous. Follow the instructions of your physician or licensed healthcare provider.
Omron Healthcare recommends you contact your physician if the Heartbeat Symbol ( ) flashes on the display with your measurement values.
DISPLAY SYMBOLS
13
1
American Heart Association Scientific Statement 2004
1. Press the tindicator on the battery cover and slide the cover off in the direction of the arrow.
2. Install 4 “AAA” size batteries so the + (positive) and – (negative) polarities match the polarities of the battery compartment as indicated.
3. Replace the battery cover.

BATTERY INSTALLATION

14
Battery Cover
BATTERY REPLACEMENT
When the Low Battery Indicator appears on the display screen, turn the monitor off and remove all the batteries. Replace with four new batteries at the same time.
WARNING
If battery fluid should get in your eyes, immediately rinse with plenty of clean water. Contact a physician immediately.
NOTES: • Turn the unit off before replacing the batteries. If the batteries
are removed while the unit is still on, the date and time will be reset to that of the previous use. However, the measurement results are not deleted.
• When the batteries are replaced, you may need to reset the date and time. If the year is flashing on the display screen, refer to “Setting the Date and Time”.
• The supplied batteries may have a shorter life.
CAUTION
Dispose of the device, components and optional accessories according to applicable local regulations. Unlawful disposal may cause environmental pollution.
BATTERY INSTALLATION
15
Low Battery Indicator
16
Set the monitor to the current date and time before taking a measurement for the first time. If the date and time are not set correctly, the measurement values stored in the memory and the average values may not be correct.
The Blood Pressure Monitor automatically stores up to 84 individual measurements values with the dates and times.
The monitor can also calculate an average reading based on the three most recent measurements taken within 10 minutes.
NOTES: • If only two readings are stored in the memory for the
10-minute period, the average is based on the two readings.
• If one reading is stored in the memory for the 10-minute period, this reading is displayed as the average.
1. TO STARTTHE SETTING
Press and hold the Date/Time Setting button ( ) to adjust the date and time.
The year flashes on the display.
SETTING THE DATE AND TIME
SETTING THE DATE AND TIME
2. SETTING THE YEAR
The year can be set between 2008 and 2030. When the display reaches 2030, it will return to
2008. Press the Memory button ( ) to advance by
increments of one year.
Press the Date/Time Setting button ( ) to set the current year.
The month flashes on the display.
NOTE: Press and hold the Memory button ( ) to advance the date and
time values faster.
3. SETTING THE MONTH
Press the Memory button ( ) to advance by increments of one month. Press the Date/Time Setting button ( )
to set the current month.
The day flashes on the display.
17
18
4. SETTING THE DAY
Press the Memory button ( ) to advance by increments of one day. Press the Date/Time Setting button
( ) to set the current day.
The hour flashes on the display.
5. SETTING THE HOUR
The time is set using AM or PM. Press the Memory button ( ) to advance by increments of one hour. Press the Date/Time Setting button
( ) to set the current hour.
The minute flashes on the display.
6. SETTING THE MINUTE
Press the Memory button ( ) to advance by increments of one minute.
Press the Date/Time Setting button ( ) to turn the monitor off.
SETTING THE DATE AND TIME
RESETTING THE DATE AND TIME
To adjust the date or time after it has been setup when you first use the unit.
Start with the monitor in the off position.
1. Press and hold the Date/Time Setting button ( ). The Medication Symbol ( ) No.1 and the current setting (on or
oFF) will appear on the display. Press the Date/Time Setting button repeatedly until the year flashes on
the display.
2. Refer to “Setting the Date and Time”. The Medication Symbol ( ) No.1 and the current setting (on or
oFF) will appear on the display, after the minute has been set.
3. Press the START/STOP button to turn the monitor off. NOTE: If you need to change the Date and Time, always adjust the
Date and Time setting before taking the next measurement.
SETTING THE DATE AND TIME
19
The Medication Reminder Alarm can be set to sound twice a day to alert the user to take a medication. The Medication Reminder Alarm can be set for either AM or PM alerts. Only set the Medication Reminder Alarm after the date and time has been set. The Medication Reminder Alarm is set to off at the time of purchase.
NOTES: • Press the START/STOP button to stop the Medication
Reminder Alarm.
• The Medication Reminder Alarm will automatically stop sounding after one minute.
• The Medication Reminder Alarm will not sound when the monitor is taking a measurement.
1. TO START THE SETTING
Press and hold the Date/Time Setting button ( ).
The Medication Symbol ( ) No.1 and the
oFF setting appear on the display.
SSEETTTTIINNGG TTHHEE MMEEDDIICCAATTIIOONN RREEMMIINNDDEERR AALLAARRMM
20
2. SETTING ON OR OFF
Press the Memory button ( ) to select on. Press the Date/Time Setting button ( ).
The hour flashes on the display. NOTE: Press the Memory button ( ) to
alternate between on or oFF.
3. SETTING THE HOUR
The time is set using AM or PM. Press the Memory button ( ) to advance by increments of one hour. Press the Date/Time Setting button ( )
to set the hour.
The minute flashes on the display.
SSEETTTTIINNGG TTHHEE MMEEDDIICCAATTIIOONN RREEMMIINNDDEERR AALLAARRMM
21
4. SETTING THE MINUTE
Press the Memory button ( ) to advance by increments of one minute.
Press the Date/Time Setting button ( ) to set the minute.
The Medication Symbol ( ) No.2 and the oFF setting appears on the display.
5. SETTING THE MEDICATION REMINDER ALARM 2
Repeat steps from 2 to 4 to set the Medication Reminder Alarm 2.
The year flashes on the display, after the Medication Reminder Alarm 2 has been set.
SSEETTTTIINNGG TTHHEE MMEEDDIICCAATTIIOONN RREEMMIINNDDEERR AALLAARRMM
22
6. TO TURN THE MONITOR OFF
If the date and time are correct, press the START/STOP button to turn the monitor off.
To change the date and time refer to “Resetting the Date and Time” on page 19.
SSEETTTTIINNGG TTHHEE MMEEDDIICCAATTIIOONN RREEMMIINNDDEERR AALLAARRMM
23
CAUTION
Read all of the information in the instruction manual and any other literature in the box before operating the unit.
CAUTION
This device is intended for use in measuring blood pressure and pulse rate in the adult population. Do not use this device on infants or persons who cannot express their intentions.
USE CUFF GUIDE TO CHOOSE THE RIGHT CUFF
There are two cuffs included in this unit, standard size and large size. Use the Cuff Guide to determine which size cuff is right for you, based on the circumference of your arm.
1. Make a loop with your Cuff Guide.

APPLYING THE ARM CUFF

24
2. Fit the looped Cuff Guide on your upper arm.
3. Cuff Guide shows your correct cuff. Use the cuff with same colored sticker.
APPLYING THE CUFF ON THE LEFT ARM
1. Make sure the air plug is securely inserted in the main unit.
APPLYING THE ARM CUFF
25
Use the Standard Cuff
Orange
Purple
Use the Large Cuff
26
2. Remove tight-fitting clothing from your upper left arm.
3. Apply the cuff to your left upper arm so the blue arrow is centered on the inside of your arm and aligned with your middle finger. The air tube runs down the inside of your arm. The bottom of the cuff should be approximately 1/2" above your elbow.
4. Wrap the cuff firmly in place around your arm using the closure strip.
APPLYING THE ARM CUFF
1/2 inch (1 - 2 cm)
Air Tube
Blue Arrow
27
APPLYING THE ARM CUFF
APPLYING THE CUFF ON THE RIGHT ARM
When taking a measurement using the right arm use this instruction for Step 3 on page 26.
Apply the cuff to your right upper arm so the blue arrow and the air tube runs along the inside of your elbow. The bottom of the cuff should be approximately 1/2'' above your elbow.
NOTE: Be careful not to rest your arm on the air tube. This will restrict
the flow of air to the cuff.
1. Sit in a chair with your feet flat on the floor. Place your left arm on a table so the cuff is level with your heart.
2. Press the START/STOP button. All symbols appear on the display. The cuff starts to inflate automatically. As the cuff inflates, the monitor
automatically determines your ideal inflation level. This monitor detects your blood pressure and pulse rate during inflation. The Heartbeat Symbol ( ) flashes at every heartbeat. Do not move your arm and remain still until the entire measurement process is completed.
NOTE: To stop the inflation or measurement, press the START/STOP
button. The monitor will stop inflating, start deflating and will turn off.

TAKING A MEASUREMENT

28
3. When the measurement is complete, the arm cuff completely deflates. Your blood pressure and pulse rate are displayed.
4. Press the START/STOP button to turn the monitor off.
NOTE: The monitor will automatically turn off
after two minutes.
TAKING A MEASUREMENT
29
USING THE GUEST MODE
The monitor is designed to take measurements and store the measurement values in the memory for one person. The monitor can also be used to take a single measurement for other persons using the GUEST Mode. Measurements taken using the Guest Mode are not stored in the memory.
1. Press and hold the START/STOP button for 3 seconds.
The Guest Symbol ( ) appears on the display.
2. Release the START/STOP button. The cuff starts to inflate automatically. NOTE: To stop the inflation, press the START/STOP button. The
monitor will stop inflating, start deflation and turn off.
3. Inflation stops and the measurement is started. When the measurement is completed, your blood pressure and pulse rate appear on the display.
TAKING A MEASUREMENT
30
Every time you complete a measurement the monitor stores the blood pressure and pulse rate in the memory.
The monitor automatically stores up to 84 sets of measurement values (blood pressure and pulse rate). When 84 sets of measurement values are stored, the oldest record is deleted to save the most recent values.
Measurements taken using the GUEST Mode are not stored in the memory.
AVERAGING FUNCTION
The monitor calculates the average reading based on the three most recent sets of measurement values taken within 10 minutes.
NOTE: If two sets of measurement values are stored in the memory for
the 10 minutes period, the average is based on the two sets of measurement values. If one set of measurement values is stored, this is displayed as the average.
TO DISPLAY THE MEASUREMENT VALUES
1. Press the Memory button ( ). The Average Symbol ( ) appears on the display when the average
reading is shown.

USING THE MEMORY FUNCTION

31
2. Press the Memory button ( ) to display the most recent set of measurement values on the screen. The values are displayed from the most recent to the oldest.
NOTE: The date and time are
alternately displayed with the measurement values.
Press the Memory button ( ) to display the next set of values.
Press and hold the Memory button ( ) to display the values faster.
3. Press the START/STOP button to turn the power off.
USING THE MEMORY FUNCTION
32
Alternating display
TO DELETE ALLVALUES STORED IN THE MEMORY
You cannot partially delete values stored in the memory.
1. Press the Memory button ( ) to turn the monitor on.
2. Press the Memory button ( ) again.
While holding it down, press the START/STOP button together for more than 5 seconds.
3. Press the START/STOP button to turn the monitor off. NOTE: The monitor will automatically turn off after two minutes.
USING THE MEMORY FUNCTION
33
34
To keep your digital blood pressure monitor in the best condition and protect the unit from damage, follow the directions listed below:
Keep the monitor in the Stylish Zipper Case when not in use.
Do not forcefully bend the arm cuff or air tube. Do not fold tightly. Clean the monitor with a soft dry cloth. Do not use any abrasive
or volatile cleaners. Do not attempt to clean the cuff.
CAUTION
Do not submerge the device or any of the components in water. Do not subject the monitor to extreme hot or cold temperatures, humidity or direct sunlight.
CAUTION
Store the device and the components in a clean, safe location.
CAUTION
Do not subject the monitor to strong shocks, such as dropping the unit on the floor.
Remove the batteries if the unit will not be used for three months or longer. Always replace all the batteries with new ones at the same time.
CARE AND MAINTENANCE
Care and Maintenance
Use the unit consistent with the instruction provided in this manual.
CAUTION
Changes or modification not approved by Omron Healthcare will void the user warranty. Do not disassemble or attempt to repair the unit or components.
CAUTION
Use only Omron authorized parts and accessories. Parts and accessories not approved for use with the device may damage the unit.
CARE AND MAINTENANCE
35
Contact your OMRON distributor or Customer Services as mentioned on the package.
A malfunction has occured.
36
SYMBOL CAUSE CORRECTION
Remove the arm cuff. Read, “Taking a Measurement”. Take another measurement.
Cuff over-inflated
Take another measurement and remain still until the measurement is complete.
Monitor could not detect pulse wave.
Air plug is not connected.
Batteries are worn
Replace the four batteries. Refer to “Battery Installation.”
ERROR INDICATORS
ERROR INDICATORS AND TROUBLESHOOTING TIPS
37
ERROR INDICATORS AND TROUBLESHOOTING TIPS
PROBLEM CAUSES AND SOLUTIONS
No power.
No display appears on the unit.
Replace all four batteries with new ones. Check the battery installation for proper placement of the battery polarities.
Measurement values appear too high or too low.
Blood pressure varies constantly. Many factors including stress, time of day, and how you wrap the cuff, may affect your blood pressure. Review the sections “Before Taking a Measurement” and “Taking a Measurement”.
TROUBLESHOOTING TIPS
38
FCC STATEMENT
NOTE:
POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only) This product has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. The product generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If the product does cause harmful interference to radio or television reception, which can be determined by turning the product on and off, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the product and the receiver.
• Connect the product into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for Canada only) This digital apparatus does not exceed the Class B limits for radio noise
emissions from digital apparatus as set out in the interference-causing equipment standard entitled “Digital Apparatus”, ICES-003 of the Canadian Department of Communications.
Cet appareil numérique respecte les limites de bruits radioeléctriques applicables aux appareils numériques de Clase B prescrites dans la norme sur le materiel brouilleur: “Appareils Numériques”, ICES-003 édictée par le minister des communications.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

WARRANTY

39
Your Omron®Elite 7300W IntelliSense®Women’s Advanced Automatic Blood Pressure Monitor, excluding the arm cuffs, is warranted to be free from defects in materials and workmanship appearing within 5 years from the date of purchase, when used in accordance with the instructions provided with the monitor. The arm cuffs are warranted to be free from defects in materials and workmanship appearing within one year from the date of purchase when the monitor is used in accordance with the instructions provided with the monitor. The above warranties extend only to the original retail purchaser.
We will, at our option, repair or replace without charge any monitor or arm cuff covered by the above warranties. Repair or replacement is our only responsibility and your only remedy under the above warranties.
To obtain warranty service contact Omron Healthcare for the address of the repair location. Shipping instructions and repair information is available by calling 1-800-634-4350 or visit our website at www.omronhealthcare.com.
Enclose the Proof of Purchase. Include $5.00 for the return shipping and handling. Include a letter, with your name, address, phone number, and description of the specific problem. Pack the product carefully to prevent damage in transit. Because of possible loss in transit, we recommend insuring the product with return receipt requested.
ALL IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITYAND FITNESS FOR PARTICULAR PURPOSE, ARE LIMITED TO THE DURATION OF THE APPLICABLE WRITTEN WARRANTY ABOVE. Some states do not
allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.
OMRON SHALL NOT BE LIABLE FOR LOSS OFUSE OR ANY OTHER INCIDENTAL, CONSEQUENTIALOR INDIRECT COSTS, EXPENSES OR DAMAGES. Some states do not allow the exclusion or limitation of incidental
or consequential damages, so the above exclusions may not apply to you. This warranty gives you specific legal rights, and you may also have other rights
which may vary from state to state.
FOR CUSTOMER SERVICE
Visit our web site at: www.omronhealthcare.com Call toll free: 1-800-634-4350
40
Model: Elite 7300W Display: LCD Digital Display Measurement Range: Pressure: 0 to 299 mmHg, Pulse: 40 to 180/min. Accuracy/Calibration: Pressure: ±3mmHg or 2% of reading
Pulse: ±5% of reading Inflation: Automatic by electric pump Deflation: Automatic rapid deflation pressure Rapid Air Release: Automatic exhaust valve Pressure Detection: Electrostatic capacity semi-conductor pressure sensor Measurement Method: Oscillometric method Pulse Wave Detection: Capacitance type pressure sensor Power Source: 4 “AAA” batteries (1.5V Alkaline) Battery Life: Approximately 300 uses when used 3 times a day with new
alkaline batteries when inflated to 170mmHg at 73ºF
(23ºC). Operating Temperature 50ºF to 104ºF (10ºC to 40ºC) /15 to 90% RH
/Humidity: Storage Temperature -4ºF to 140ºF (-20ºC to 60ºC) /10 to 95% RH
/Humidity/Air Pressure: /700 - 1060 hPa Main Unit Weight: Approximately 8 1/2 oz. (240 g)
not including batteries Main Unit Dimensions: Approximately 6 3/16" (l) × 2 15/16" (w) × 1 7/32" (h)
(157 mm × 74 mm × 30.6 mm) Cuff Size: Standard Cuff
Approximately 5 3/4" (w) × 17 1/2" (l) (146 mm × 446 mm) Cuff tube 23 5/8" (l) (600 mm)
Large Cuff
Approximately 6 7/8" (w) × 25 11/16" (l) (174 mm × 652 mm) Cuff tube 35 7/16" (l) (900 mm)
Cuff Circumference: Standard Cuff fits arm circumferences 9" to 13"
(220 mm to 320 mm)
Large Cuff fits arm circumferences 13" to 17"
(320 mm to 420 mm)
SPECIFICATIONS
Memory: Up to 84 readings Contents: Main Unit, Standard and Large Arm Cuffs,
Instruction Manual, 4 “AAA” batteries, Stylish Zipper Case, Quick Guide, Warranty Card and Cuff Guide
UPC Code: 0 73796 73000 0
NOTE: These specifications are subject to change without notice.
SPECIFICATIONS
41
Manufactured by OMRON HEALTHCARE
Made in China
Distributed by:
OMRON HEALTHCARE, INC.
1200 Lakeside Drive Bannockburn, Illinois 60015 www.omronhealthcare.com
Copyright © 2007 Omron Healthcare, Inc.
Loading...