Omron ELITE 7300W User Manual

Women’s Advanced
Automatic Blood Pressure Monitor
with Two Cuffs
Model Elite 7300W

INSTRUCTION MANUAL

ESPAÑOL
ENGLISH
2
Before Using the Monitor
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Operating the Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Care and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Before Taking a Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Operating Instructions
Know Your Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Unit Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Display Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Irregular Heartbeat Symbol ( ) . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Movement Error Symbol ( ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Heartbeat Symbol/Hypertension Indicator ( ) . . . . . . . . . . . . . . .12
Average Value Symbol ( ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Battery Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Setting the Date and Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Setting the Medication Reminder Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Applying the Arm Cuff . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Taking a Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
Using the Guest Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Using the Memory Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
Averaging Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
To Display the Measurement Values . . . . . . . . . . . . . . . . . . . . . . . . .31
To Delete All Values Stored in the Memory . . . . . . . . . . . . . . . . . . .33
Care and Maintenance
Care and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
Error Indicators and Troubleshooting Tips . . . . . . . . . . . . . . . . . . . . . . . . . .36
FCC Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40

TABLE OF CONTENTS

3
Thank you for purchasing the Omron®Elite 7300W IntelliSense
®
Women’s Advanced Automatic Blood Pressure Monitor.

INTRODUCTION

Fill in for future reference.
DATE PURCHASED: __________________ SERIAL NUMBER: ____________________
Staple your purchase receipt here
Your new digital blood pressure monitor uses the oscillometric method of blood pressure measurement. This means the monitor detects your blood’s movement through your brachial artery and converts the movements into a digital reading. An oscillometric monitor does not need a stethoscope so the monitor is simple to use.
The Elite 7300W comes with the following components:
• Monitor • Standard Arm Cuff • Large Arm Cuff
• 4 “AAA” Batteries • Stylish Zipper Case
• Instruction Manual printed in English and Spanish
• Quick Guide • Warranty Card • Cuff Guide The Elite 7300W IntelliSense
®
Women’s Advanced Automatic Blood
Pressure Monitor is intended for home use. While the Omron Elite 7300W is designed for women, it has also been
clinically proven accurate for all adults, regardless of gender. So you can be assured that this product can be used by men and women.
SAVE THESE INSTRUCTIONS
Before Using the Monitor
4
To assure the correct use of the product basic safety measures should always be followed including the warnings and cautions listed in this instruction manual.
WARNING
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL
CAUTION
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury to the user or patient or damage to the equipment or other property.
OPERATING THE DEVICE
Contact your physician for specific information about your blood pressure. Self-diagnosis and treatment using measured results may be dangerous. Follow the instructions of your physician or licensed healthcare provider.
If battery fluid should get in your eyes, immediately rinse with plenty of clean water. Contact a physician immediately.
People with severe blood flow problems, or blood disorders, should consult a doctor before using the unit. Cuff inflation can cause internal bleeding.
Read all of the information in the instruction manual and any other literature in the box before operating the unit.

SAFETY INFORMATION

OPERATING THE DEVICE (continued)
This device is intended for use in measuring blood pressure and pulse rate in the adult population. Do not use this device on infants or persons who cannot express their intentions.
Inflating to a higher pressure may result in bruising where the cuff is
applied.
Operate the device only as intended. Do not use the device for any other purpose.
Dispose of the device, components and optional accessories according to applicable local regulations. Unlawful disposal may cause environmental pollution.
Do not use a cellular phone near the device. It may result in an operational failure.
Use only Omron authorized parts and accessories. Parts and accessories not approved for use with the device may damage the unit.
Use only 1.5V alkaline batteries with this device. Do not use other types of batteries. This may damage the unit.
SAFETY INFORMATION
5
CARE AND MAINTENANCE
Do not subject the monitor to strong shocks, such as dropping the unit on the floor.
Do not submerge the device or any of the components in water.
Store the device and the components in a clean, safe location.
Changes or modification not approved by Omron Healthcare will void the user warranty. Do not disassemble or attempt to repair the unit or components.
SAFETY INFORMATION
6
7

BEFORE TAKING A MEASUREMENT

To ensure a reliable reading follow these recommendations:
1. Avoid eating, drinking alcohol, smoking, exercising, and bathing for 30 minutes before taking a measurement. Rest for at least 15 minutes before taking the measurement.
2. Stress raises blood pressure. Avoid taking measurements during stressful times.
3. Measurements should be taken in a quiet place.
4. Remove tight-fitting clothing from your arm.
5. Sit in a chair with your feet flat on the floor. Rest your arm on a table so that the cuff is at the same level as your heart.
6. Remain still and do not talk during the measurement.
7. Keep a record of your blood pressure and pulse readings for your physician. A single measurement may not provide an accurate indication of your true blood pressure. You need to take and record several readings over a period of time. Try to measure your blood pressure at about the same time each day for consistency.
8. Wait 2-3 minutes between measurements. The wait time allows the arteries to return to the condition prior to taking the blood pressure measurement. You may need to increase the wait time depending on your individual physiological characteristics.
8
KNOW YOUR UNIT
Main Unit:
Operating Instructions
Battery Compartment
Memory Button ( )
Display
Date/Time Setting Button ( )
Air Jack
Start/Stop Button
KNOW YOUR UNIT
9
Components:
Arm Cuffs
Air Tube
Air Plug (Connects to Air Jack)
Stylish Zipper Case
Four “AAA”Batteries
Instruction Manual
Quick Guide
Thank you for purchasing the Omron¤Elite 7300WIntelliSense
¤
Womens Advanced Automatic Blood Pressure Monitor. There are two cuffs included in this unit, standard size and large size. This sheet simply explains how to choose the correct size cuff with Cuff Guide. However, please read the instruction manual thoroughly before using the unit.
1. Make a loop with your Cuff Guide.
2. Fit the looped Cuff Guide on your upper arm.
3. Cuff Guide shows your correct cuff. Use the cuff with same colored sticker.
QUICK GUIDE
5318770-0A
Use the Cuff Guide to get your upper arm size, then choose the right size cuff.
(9"-13")
Use the Cuff Guide to get your upper arm size, then choose the right size cuff.
(13"-17")
Use the Standard Cuff
Use the Large Cuff
Orange
Purple
Cuff Guide
Standard Arm Cuff
Air Tube
Air Plug (Connects to Air Jack)
Large Arm Cuff
INSTRUCTION MANUAL
Women’s Advanced
Automatic Blood Pressure Monitor
with Two Cuffs
Model
Elite 7300W
ESPAÑOL
ENGLISH
10

UNIT DISPLAY

Movement Error Symbol
Low Battery Indicator
Deflation Symbol
Heartbeat Symbol/ Hypertension Indicator
Irregular Heartbeat Symbol
Average Value Symbol
Memory Symbol
Pulse Display
Medication Symbol
Date/Time Display
Guest Symbol
Systolic Blood Pressure
Diastolic Blood Pressure
11
IRREGULAR HEARTBEAT SYMBOL ()
When the monitor detects an irregular rhythm two or more times during the measurement, the Irregular Heartbeat Symbol ( ) will appear on the display with the measurement values.
An irregular heartbeat rhythm is defined as a rhythm that is more than 25% slower or 25% faster from the average rhythm detected while the monitor is measuring the systolic blood pressure and the diastolic blood pressure.
If the Irregular Heartbeat Symbol ( ) displays with your measurement results, we recommend you consult your physician. Follow the directions of your doctor.
MOVEMENT ERROR SYMBOL ()
The Movement Error Symbol () is displayed if you move your body during the measurement. Please remove the arm cuff, and wait 2-3 minutes. Take another measurement.
NNormal H
ormal H
ear
eartbtb
eat
eat
Irregular Heartbeat
Pulse
Blood
pressure
Pulse
Blood
pressure
Short Long

DISPLAY SYMBOLS

HEARTBEAT SYMBOL/HYPERTENSION INDICATOR ()
TAKING A MEASUREMENT
The Heartbeat Symbol ( ) flashes on the display during the measurement. The Heartbeat Symbol ( ) flashes at every heartbeat.
When the measurement is complete, the Heartbeat Symbol ( ) flashes on the display with your blood pressure and pulse rate if the reading is above 135 for the Systolic Blood Pressure value and/or 85 for the Diastolic Blood Pressure value.
USING THE MEMORY FUNCTION
The Heartbeat Symbol ( ) flashes when the blood pressure reading stored in the memory is above 135 for the Systolic Blood Pressure value and/or 85 for the Diastolic Blood Pressure value.
AVERAGE VALUE SYMBOL ()
The Average Value Symbol () is displayed when you press the Memory button ( ). The most recent average reading appears on the display screen.
DISPLAY SYMBOLS
12
The American Heart Association recommends the following guideline for upper limit of normal for home blood pressure readings:
AHA Home Guideline for UpperLimit of Normal BP
Systolic Blood Pressure 135 mmHg Diastolic Blood Pressure 85 mmHg This is a general guideline because blood pressure depends on
age and morbidity. The AHA recommends a lower home blood pressure goal for certain patients, including diabetic patients, pregnant women, and patients with renal failure
1
.
The monitor is not intended to be a diagnostic device.
WARNING
Contact your physician for specific information about your blood pressure. Self-diagnosis and treatment using measured results may be dangerous. Follow the instructions of your physician or licensed healthcare provider.
Omron Healthcare recommends you contact your physician if the Heartbeat Symbol ( ) flashes on the display with your measurement values.
DISPLAY SYMBOLS
13
1
American Heart Association Scientific Statement 2004
Loading...
+ 29 hidden pages