Rated power supply voltage24 VDC
Communications power supply voltage---11 to 25 VDC (supplied by communications connector)
Power consumption
supply
Vibration resistance10 to 20 Hz, 9.8 m/s2 max.
Ambient operating temperature-10 to 45 °C
Ambient operating relative humidity10% to 90% (no condensation)
Ambient storage temperature-20 to 70 °C
AtmosphereMust be free from corrosive gas
Control methodStore program method
I/O control methodCyclic scan method
Programming languageLadder chart method
Instruction length1 step/1 instruction; 1 to 5 words/1 instruction
Instruction typesBasic14 types (same as for programmable slaves)
Processing speedBasic instructions0.64 µs (LD)
Program capacity4,096 words
Maximum number of I/O points10
Input bits00000 to 00015 (6 physical inputs)
Output bits01000 to 01003 (4 physical outputs)
CompoBus/S input bits128 bits: IR 02000 to IR 02715 (bits not used for CompoBus/S input bits can be used for work bits.)
CompoBus/S output bits128 bits: IR 03000 to IR 03715 (bits not used for CompoBus/S output bits can be used for work bits.)
Inverter interfaceDirect interface with inverter through
Inverter interface bits176 bits: IR 20000 to IR 21015
Encoder interface bits48 bits: IR 02900 to IR 02915 and IR 04800 to IR 04915
Work bits448 bits: IR 02800 to IR 02815, IR 03800 to IR 04715, and IR 21100 to IR 22715
Special bits (SR area)448 bits: SR 22800 to SR 25507 (words SR 228 to SR 255)
Temporary bits (TR area)8 bits (TR 0 to TR 7)
Holding bits (HR area)320 bits: HR 0000 to HR 1915 (words HR 00 to 19)
Auxiliary bits (AR area)384 bits: AR 0000 AR 2315 (words AR 00 to AR 23)
Internal power2 W (supplied internally) (see note)3 W (supplied internally) (see note)
Communications power supply ---30 mA max.
Special105 types, 185 instructions (same as for programmable slaves)
Special instructions7.8 µs (MOV)
+10%
/
(external power supply for I/O)
-15%
20 to 50 Hz, 2 m/s2 max
• IR-memory
• DM-memory
• Transfer command
3663G3RV-P10ST@-E
ItemSpecifications
Link bits (LR area)256 bits: LR 0000 to LR 1515 (words LR 00 to LR 15)
Timers/counters256 timers/counters (TIM/CNT 000 to TIM/CNT)
CompoBus/S master functionsRemote I/O devices can be allocated up to 256 I/O points (128 inputs and 128 outputs) in input area IR 020 to
DeviceNet slave functionsUp to 64 words (32 input words and 32 output words) can be allocated to the DeviceNet master's I/O.
DM areaRead/write2,029 words (DM 0000 to DM 0999, DM 1019 to DM 2047)
Read only456 words (DM6144 to 6599)
Inverter interface19 words (DM 2022 to DM 2040)
Encoder interface14 words (DM 1986 to DM 1999)
InterruptsInterrupt inputs
High-speed counters High-speed counter 1 input,
Encoder interface3 input modes:
Pulse outputs• 2 outputs:
Synchronized pulse control1 point, see notes 5 and 6
Pulse catch inputs2 bits
Analog volumeNone
Input time constant
(ON response time = OFF response time)
Clock/Calendar functionShows the current year, month, day of the week, day of the month, hour, minute, and second.
Communication functionPort 1 = Peripheral and RS-422:
PLC setup56 words (DM 6599 to DM 6655)
see note 5
Differential phase mode (5 kHz)
Pulse plus direction input mode
(20 kHz)
Up/down input mode (20 kHz)
Increment mode (20 kHz)
• The node numbers can be set to 0 to 7 (128-point mode) or 0 to 15 (256-point mode).
• The communications mode can be set to high-speed mode (max. length 100 m) or long-distance mode
(max. length 500 m).
The master's I/O can be allocated to the following data areas:
• Explicit message communications are supported. Any 3G3RV-P10ST data area can be accessed from the
• The communications speed can be set to 500 kbps (total network length 100 m max.), 250 kbps (total network
DM 2000 to DM 2021: error log storage area
2 inputs
Response time: 50 µs
Interval timer interrupts
1 input
Set value: 0.5 to 319,968 ms
Precision: 0.1 ms
No interrupt
Count-check interrupt
(An interrupt can be generated when the count equals the set value or the count lies within a preset range.)
No interrupt
Count-up interrupt
Maximum input frequency 50 kHz
Maximum counter range 4,294,967,295 (232-1)
Two capture registers, 3 selectable registration inputs
One comparison value
Counter reset through software or Z-phase
Interrupt function
• 2 outputs:
• 1 output:
Minimum pulse input: 50 µs max.
Used in common by input interrupts and input interrupt counter mode.
Determines the input time constant for all inputs. (settings: 1, 2, 3, 5, 10, 20, 40, or 80 ms)
Port 2 = RS-232C port:
IR 000 to IR 049
IR 200 to IR 227
DM 0000 to DM 2047
LR 00 to LR 15
HR 00 to HR 19
AR 00 to AR 23 (3G3RV-P10ST ' master; read-only)
TC 000 to TC 255
DeviceNet master.
length 250 m max.), or 125 kbps (total network length 500 m max.).
Scheduled interrupts
One-shot interrupt
Differential-phase (up/down)
Pulse plus direction
Up/down pulse
Single-phase pulse output without acceleration/deceleration (see note 6.)
10 Hz to 10 kHz
Variable duty ratio pulse output (see note 6.)
0.1 to 999.9 Hz, duty ratio 0 to 100%
Pulse output with trapezoidal acceleration/deceleration (see note 6.)
Pulse plus direction output, up/down pulse output, 10 Hz to 10 kHz
Input frequency range: 10 to 500 Hz, 20 Hz to 1 kHz, or 300 Hz to 20 kHz
Output frequency range: 10 Hz to 10 kHz
Power-interruption hold functionHolds the contents of HR, AR, CNT, and DM areas.
Memory backup (see notes 1 and 2.)Flash memory:Program, read-only DM area, and PC setup
Memory backup: The read/write DM area, HR area, AR area, and counter values are backed up.
(The battery has a 5-year lifetime at 25 °C and it is replaceable.)
Self-diagnostic functionCPU errors, memory errors, communications errors, setting errors, battery errors
Program checkNo END instruction, program errors (regularly checked during operation)
Connected toolsCX-programmerAfter version 2.1
Programming consoleC200H-PRO27, CQM1-PRO01
SSSPC98 & PC/AT (SYSMAC support software, all versions)
CX-driveVersion 1 or higher
Note: 1. The DM area, HR area, AR area, and counter values are
backed up. If the backup battery or capacitor is discharged,
the contents of these areas will be lost and the data values will
revert to the defaults.
2. The contents of the program area, read-only DM area
(DM6144 to DM6599), and PLC setup (DM 6600 to DM 6655)
are stored in flash memory. The contents of these areas will
be read from flash memory the next time the power is turned
ON, even if the backup battery or capacitor is discharged.
3. Changes made while in MONITOR mode using, for example,
online editing, are written to flash memory in real-time.
4. The above figure for power consumption includes the power
consumption of the programming console.
5. This input is shared by the high-speed counter and synchro-
nized pulse control functions.
6. This output is shared by the pulse output and synchronized
pulse control functions.
When data has been changed in any of these areas, write the
new values to flash memory by switching the 3G3RV-P10ST
to MONITOR or RUN mode, or by turning the power OFF and
then ON again.
I/O specifications
Input specifications
ItemInputsSpecification
Input voltageAll24 VDC
Input impedanceIN 00000 to IN 000012.7 kΩ
IN 00002 to IN 000043.9 kΩ
IN 000054.7 kΩ
Input currentIN 00000 to IN 000018 mA typical
IN 00002 to IN 000046 mA typical
IN 000055 mA typical
ON voltage/currentIN 00000 to IN 0000117 VDC min., 5 mA
IN 00002 to IN 0000514.4 VDC min., 3.5 mA
OFF voltage/currentAll5.0 VDC max., 1.1 mA
ON delayAll1 to 80 ms max. Default: 10 ms (see note.)
OFF delayAll1 to 80 ms max. Default: 10 ms (see note.)
Circuit configurationIN 00000 to IN 00001
IN 00002 to IN 00004
IN 00005
+10%
/
-15%
IN
2.7 kΩ
COM
COM
COM
IN
3.9 kΩ
IN
4.7 kΩ
820 Ω
750 Ω
0.01
µF
1kΩ
Input LED
Input LED
Input LED
Internal circuits
Internal circuits
Internal circuits
Note: The input time constant can be set to 1, 2, 3, 5, 10, 20, 40, or 80 ms in the PLC setup.
High-speed counter inputs
The following unit input bits can be used as high-speed counter inputs. The maximum count frequency is 5 kHz in differential phase mode and
20 kHz in the other modes.
InputFunction
IN 00000A-phase pulse inputPulse inputIncrement pulse inputIncrement pulse input
IN 00001B-phase pulse inputDirection inputDecrement pulse inputNormal input
IN 00002Z-phase pulse input or hardware reset input (IN00002 can be used as a normal input when it is not used as a high-speed counter input.)
Differential phase modePulse plus direction input mode Up/down input modeIncrement mode
3683G3RV-P10ST@-E