Omron E3U-GS5-C4-S-M5, E3U-GS5-B4-S-M5, E3U-GS8-C4-S-M5, E3U-GS8-B4-S-M5, E3U-GS12-C4-S-M5 Datasheet

...
Page 1
Photoelectric sensors in stainless steel fork shape housing
E3U-GS_-S
The fork shape of the E3U-GS photoelectric sensors provides
simple installation, positioning and alignment for the detection
of objects. The detergent resistant stainless steel (SUS 316L)
housing makes this sensor ideal for usage in frequently
cleaned areas.
• Slot sizes from 50 to 120 mm
• Visible red LED for simple and precise positioning
• Easy adjustment by potentiometer and L-on/D-on switch
Ordering Information
Sensor type Sensing distance Connection method Order Code
NPN output PNP output
Through-beam Red light 50 mm slot width
80 mm slot width
120 mm slot width
–––
–––
–––
E3U-GS5-C4-S-M5 E3U-GS5-B4-S-M5
E3U-GS8-C4-S-M5 E3U-GS8-B4-S-M5
E3U-GS12-C4-S-M5 E3U-GS12-B4-S-M5
Accessories
Sensor I/O connectors
Size Shape Type Features Material Order code
Nut Cable
M8 Detergent
resistant
Note: For the complete list of sensor I/O connectors refer to E26E Accessories datasheet.
3 pin Stainless steel PVC 2 m Y92E-S08PVC3S2M-L Y92E-S08PVC3A2M-L
1E3U-GS_-S
Page 2
Specifications
E3U-GS_
Slot width 50 mm 80 mm 120 mm
Light source (wave length) Red LED (660 nm)
Min. detectable object size dia 0.5 mm dia 0.8 mm
Power supply voltage 10 to 35 VDC
Operating frequency 4,000 Hz 2,000 Hz
Control output Transistor, Load current 200 mA max., light-ON/dark-ON switch selectabel
Sensitivity adjustment one turn potentiometer adjuster
Side by side mounting (gang mounting)
Ambient illumination 10,000 lx max.
Ambient temperature Operating: -10°C to 60°C
Degree of protection IEC 60529: IP67
Indicators Operation indicator (yellow)
Weight 50 g 60 g 70 g
Material (case) Stainless steel (SUS 316L)
possible not possible
Output Circuit Diagram
PNP NPN
Brown
10 to 35VDC
1
Brown
10 to 35VDC
1
Load
Black
4
Load
Blue
3
0V
M8 connector
(3 pin)
Pin Arrangement
4
3
1
Black
4
Blue
3
0V
2 Photoelectric Sensors
Page 3
Dimensions
M8
L-ON/D-ON
Sensitivity adjuster
Operation LED (yellow)
E3U-GS5_
E3U-GS8_
M8
Operation LED (yellow)
L-ON/D-ON
Sensitivity adjuster
3E3U-GS_-S
Page 4
E3U-GS12_
3060
100
Operation
LED
(yellow)
22
10
M8
12
62
52
37
10
10 12
Ø4,3
120
5
20
Sensitivity
adjuster
L-ON/D-ON
4 Photoelectric Sensors
Page 5
Safety precautions
! Warning
This product is not designed or rated for directly or indirectly ensuring safety of persons. Do not use it for such a purpose.
! Caution
Do not use the product with voltage in excess of the rated voltage. Excess voltage may result in malfunc­tion or fire.
Never use the product with an AC power supply. Otherwise, explosion may result.
When cleaning the product, do not apply a high-pres­sure spray of water to one part of the product. Other­wise, parts may become damaged and the degree of protection may be degraded.
High-temperature environments may result in burn injury.
Precautions for Safe Use
The following precautions must be observed to ensure safe operation of the Sensor.
Operating Environment
Do not use the Sensor in an environment where explosive or flammable gas is present.
Connecting Connectors
Be sure to hold the connector cover when inserting or removing the connector. Be sure to tighten the connector lock by hand; do not use pliers or other tools. If the tightening is insufficient, the degree of protection will not be maintained and the Sensor may become loose due to vibration. The appropriate tightening torque is 0.4 to 0.5 N·m for M12 connectors and 0.3 Nm for M8 connec­tors.
Load
Do not use a load that exceeds the rated load.
Modifications
Do not attempt to disassemble, repair, or modify the Sensor.
Outdoor Use
Do not use the Sensor in locations subject to direct sunlight.
Surface Temperature
Burn injury may occur. The Sensor surface temperature rises de­pending on application conditions, such as the surrounding tem­perature and the power supply voltage. Use caution when operating or washing the Sensor.
Precautions for Correct Use
Do not use the Sensor in any atmosphere or environment that exceeds the ratings.
Do not install the Sensor in the following locations.
(1)Locations subject to direct sunlight (2)Locations subject to condensation due to high humidity (3)Locations subject to corrosive gas (4)Locations where the Sensor may receive direct vibration or
shock
Connecting and Mounting
(1)The maximum power supply voltage is 35 VDC. Before turning
the power ON, make sure that the power supply voltage does not exceed the maximum voltage.
(2)Laying Sensor wiring in the same conduit or duct as high-volt-
age wires or power lines may result in malfunction or damage due to induction. As a general rule, wire the Sensor in a sepa­rate conduit or use shielded cable.
(3)Use an extension cable with a minimum thickness of 1 mm
and less than 100 m long. (4)Do not pull on the cable with excessive force. (5)Pounding the Sensor with a hammer or other tool during
mounting will impair water resistance. (6)Mount the Sensor either using a suitable bracket or on a flat
surface. (7)Be sure to turn OFF the power supply before inserting or re-
moving the connector.
Power Supply
If a commercial switching regulator is used, ground the FG (frame ground) terminal.
Turning OFF the Power Supply
Output pulses may be generated even when the power supply is OFF. Therefore, it is recommended to first turn OFF the power supply for the load or the load line.
Load Short-circuit Protection
This Sensor is equipped with load short-circuit protection, but be sure to not short circuit the load. Be sure to not use an output cur­rent flow that exceeds the rated current.
2
5E3U-GS_-S
Page 6
WARRANTY
In the interest of product improvement, specifications are subject to change without notice.Cat. No. E69E-EN-01
OMRON EUROPE B.V.
Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands Phone: +31 23 568 13 00 Fax: +31 23 568 13 88 www.industrial.omron.eu
OMRON’s exclusive warranty is that the products are free from de­fects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EX­PRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MER­CHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WAR­RANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDI­RECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall responsibility of OMRON for any act exceed the in­dividual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRAN­TY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON’S ANALYSIS CONFIRMS THAT THE PROD­UCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
SUITABILITY FOR USE
THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR EN­SURING SAFETY OF PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES. Please refer to separate catalogs for OM­RON's safety rated products.
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer’s application or use of the product.
At the customer’s request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combina­tion with the end product, machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document.
• Nuclear energy control systems, combustion systems, railroad sys­tems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate in­dustry or government regulations.
• Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PERFORMANCE DATA
Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual perfor­mance is subject to the OMRON Warranty and Limitations of Liability.
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be as­signed to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for man­ufacturing purposes, even when tolerances are shown.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user’s programming of a pro­grammable product, or any consequence thereof.
6 Photoelectric Sensors
Loading...