A-235E3S-A
E3S-A
Ratings / Characteristics
Item Through-beam Retroreflective Diffuse reflective
E3S-AT11, 16, 21,
31, 36, 41, 61, 66,
71, 81, 86, 91
E3S-AR11, 16, 21,
31, 36, 41, 61, 66,
71, 81, 86, 91
E3S-AD23, 43,
73, 93
E3S-AD13, 18,
33, 38, 63, 68,
83, 88
E3S-AD11, 16,
21, 31, 36, 41,
61, 66, 71, 81,
86, 91
E3S-AD12, 17,
22, 32, 37, 42,
62, 67, 72, 82,
87, 92
Power supply voltage 10 to 30 V DC, ripple: 10 % max.
Current consumption 40 mA max. (emitter
and receiver) plus
approx. 15 mA with
turbo function
30 mA max. plus approx. 15 mA with turbo function
35 mA max. 30 mA max.
plus approx.
15 mA with turbo function
35 mA max.
Rated
sensing
distance
White mat
paper
0 to 7 m 0.1 to 2 m 0.1 to 10 cm 0.1 to 20 cm 0 to 70 cm
Black mat
paper
0 to 7 m 0.1 to 2 m 0.3 to 2.5 cm 0.5 to 20 cm 0.15 to 33 cm
Standard sensing object (white mat paper)
7 mm min. 30 mm min. 10 x 10 cm 20 x 20 cm
Variation in sensing
distance
---
30 %
/
-0 %
max.
Hysteresis --- 20 % max. 10 % max. 20 % max.
Sensing distance with
attachment
E39-E6: 2.4 m
2-mm slit: 2.5 m
1-mm slit: 1.1 m
0.5-mm slit: 0.5 m
E39-R3:
10 to 130 cm
E39-R4: 7 to 60 cm
E39-RSA:
10 to 60 cm
E39-RSB:
10 to 30 cm
---
Min. sensing object without slit: 2.0 mm
2-mm slit: 0.8 mm
1-mm slit: 0.4 mm
0.5-mm slit: 0.2 mm
E39-R1 Reflector:
10 mm
E39-R3: 3 mm
E39-R4: 1.0 mm
---
Difference in direction
between optical axis
and mounting direction
±2° max. (checked along extended line in
the mounting direction)
±2° max.
Response time 0.5 ms max. for both operation and release
Control output 30 VDC, 100 mA max. (residual voltage: 1 V max.) Open collector (residual voltage: 0.4 V max. at 16 mA)
Self-diagnostic output Only Sensors with self-diagnostic function: 50 mA max, 30 VDC (residual voltage: 1 V max.), open collector (re-
sidual voltage: 0.4 V max. 16 mA)
External
diagnostic input
Input
Voltage
With emitter OFF:
NPN: 0 V short-circuit or 1.5 V max. (push
current: 1 mA max.)
PNP: DC short-circuit or –1.5 V DC max.
(pull current: 3 mA max.)
With emitter ON: NPN/PNP
Open (max. input voltage: 30 V max. with
0.1 mA current leakage)
---
Response
time
0.5 ms max.
Ambient illumination Incandescent lamp: Illumination on optical spot: 5,000 lx max.
Sunlight: Illumination on optical spot:10,000 lx max.
Ambient temperature Operating: –25°C to 55°C (with no icing)
Storage: –40°C to 70°C (with no icing)
Ambient humidity Operating: 35% to 85%
Storage: 35% to 95%
Insulation resistance 20 MW min. (at 500 V DC)
Dielectric strength 1,000 V AC, 50/60 Hz for 1 min
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude (30G) 2 hrs each in three directions
Shock resistance Destruction: Approx. 50G 3 times each in three directions
Enclosure ratings IEC: IP67; NEMA: 4X