Omron E3S-AR16, E3S-AT11, E3S-AT61, E3S-AR61, E3S-AT66 Datasheet

...
Page 1
E3S-A
A-231E3S-A
Built-in Amplifier Photoelectric Sensor
E3S-A
Ordering Information
E3S-A General-purpose Sensors
Connections Appearance Sensing
Sensing distance
Operating
modes
Output / timer
functions
Model
NPN output PNP output
Prewired Horizontal Through-beam 7 m Light-ON
Dark-ON (selectable)
--- E3S-AT11 E3S-AT31 With timer and
self-diagnostic functions
E3S-AT21 E3S-AT41
Retroreflective 0.1 to 2 m
(polarized)
--- E3S-AR11 E3S-AR31 With timer and
self-diagnostic functions
E3S-AR21 E3S-AR41
Diffuse reflec­tive
10 cm (light source: infra­red)
--- E3S-AD13 E3S-AD33 With timer and
self-diagnostic functions
E3S-AD23 E3S-AD43
20 cm --- E3S-AD11 E3S-AD31
With timer and self-diagnostic functions
E3S-AD21 E3S-AD41
70 cm (light source: infra­red)
--- E3S-AD12 E3S-AD32 With timer and
self-diagnostic functions
E3S-AD22 E3S-AD42
Page 2
A-232 Standard Photoelectric Sensors
Accessories (Order Separately)
E3S-A General-purpose Sensor Accessories
Prewired Vertical Through-beam 7 m Light-ON
Dark-ON (selectable)
--- E3S-AT61 E3S-AT81 With timer and
self-diagnostic functions
E3S-AT71 E3S-AT91
Retroreflective 0.1 to 2 m
(polarized)
--- E3S-AR61 E3S-AR81 With timer and
self-diagnostic functions
E3S-AR71 E3S-AR91
Diffuse reflec­tive
10 cm (light source: infra­red)
--- E3S-AD63 E3S-AD83 With timer and
self-diagnostic functions
E3S-AD73 E3S-AD93
20 cm --- E3S-AD61 E3S-AD81
With timer and self-diagnostic functions
E3S-AD71 E3S-AD91
70 cm (light source: infra­red)
--- E3S-AD62 E3S-AD82 With timer and
self-diagnostic functions
E3S-AD72 E3S-AD92
Connector Horizontal Through-beam 7 m --- E3S-AT16 E3S-AT36
Retroreflective 0.1 to 2 m
(polarized)
E3S-AR16 E3S-AR36
Diffuse reflec­tive
10 cm (light source: infra­red)
E3S-AD18 E3S-AD38
20 cm E3S-AD16 E3S-AD36 70 cm (light
source: infra­red)
E3S-AD17 E3S-AD37
Vertical Through-beam 7 m --- E3S-AT66 E3S-AT86
Retroreflective 0.1 to 2 m
(polarized)
E3S-AR66 E3S-AR86
Diffuse reflec­tive
10 cm (light source: infra­red)
E3S-AD68 E3S-AD88
20 cm E3S-AD66 E3S-AD86 70 cm (light
source: infra­red)
E3S-AD67 E3S-AD87
Name Model Remarks
Slit for Through-beam Sensor E39-S46 2 mm, 1 mm, and 0.5 mm slits are sold in pairs, one each
for the receiver and emitter of a through-beam model
Mounting Bracket for Vertical Sensor E39-L59 Purchase two brackets for each through-beam model
E39-L81
Filter for Mutual Interference Prevention (for Through-beam Sensor)
E39-E6 4 filters are sold together for two through-beam models (2
filters each for the emitters and receivers)
Reflector for Optical Axis Adjustment (for Through-beam Sensor)
E39-R5 One only
Connections Appearance Sensing
method
Sensing distance
Operating
modes
Output / timer
functions
Model
NPN output PNP output
Page 3
A-233E3S-A
E3S-A
Plugs (for Sensors with Connector Terminals)
Reflectors
Specifications
Without self-diagnostic functions
Cord Appearance Cord length Model
Standard Straight (3 conductor) 2 m XS2F-D421-DC0-A
5 m XS2F-D421-GC0-A
L-shape (3 conductor) 2 m XS2F-D422-DC0-A
5 m XS2F-D422-GC0-A
Robot (vibration-proof) Straight (4 conductor) 2 m XS2F-D421-D80-R
5 m XS2F-D421-G80-R
L-shape (43 conductor) 2 m XS2F-D422-D80-R
5 m XS2F-D422-G80-R
Name Model Remarks Mini-reflector E39-R4 One Small Reflector E39-R3 One Reflector Tape E39-RS1, RS2, RS3 One (sealed type)
Sensing method Through-beam, Retrore-
flective (polarized)
Diffuse reflective: 10 cm Diffuse reflective: 20 cm Diffuse reflective: 70 cm
Model NPN output E3S-AT11, -AR11
E3S-AT16, -AR16 E3S-AT61, -AR61 E3S-AT66, -AR66
E3S-AD13 E3S-AD63 E3S-AD18 E3S-AD68
E3S-AD11 E3S-AD16 E3S-AD61 E3S-AD66
E3S-AD12 E3S-AD17 E3S-AD62 E3S-AD67
PNP output E3S-AT31, -AR31
E3S-AT36, -AR36 E3S-AT81, -AR81 E3S-AT86, -AR86
E3S-AD33 E3S-AD83 E3S-AD38 E3S-AD88
E3S-AD31 E3S-AD36 E3S-AD81 E3S-AD86
E3S-AD32 E3S-AD37 E3S-AD82 E3S-AD87
Wavelength of LED light source
700 nm (red) 880 nm (infrared) 700 nm (red) 880 nm (infrared)
Sensitivity adjustment Two-turn (endless) sensitivity adjustor with indicator Self-diagnostic functions --­Timer --­Turbo function --­Method of connection Prewired / connector Weight Prewired type: 60 g; connector type: 11 g Operation mode Dark-ON or Light-ON (switchable) Output Open collector current output (NPN or PNP) Circuit protection Load short-circuit protection, reverse connection protection, mutual interference prevention (except for
through-beam models)
Indicators Light indicator (red) and stability indicator (green); emittion indicator (red) for the emitter of through-beam
models
Materials Case:
Lens: Mounting bracket:
Polybutylene terephtalate Denaturated polyallalate Stainless steel (SUS304)
Attachments Mounting bracket, sensitivity adjustor knob, screws, sensitivity adjustor cover, close-mounting plate (only for
Sensors with connector terminals) and reflector (E39-R1: only for retroreflective Sensors)
Page 4
A-234 Standard Photoelectric Sensors
With self-diagnostic functions
Sensing method Through-beam, Retrore-
flective (polarized)
Diffuse reflective: 10 cm Diffuse reflective: 20 cm Diffuse reflective: 70 cm
Model NPN output E3S-AT21
E3S-AR21 E3S-AT71 E3S-AR71
E3S-AD23 E3S-AD73
E3S-AD21 E3S-AD71
E3S-AD22 E3S-AD72
PNP output E3S-AT41
E3S-AR41 E3S-AT91 E3S-AR91
E3S-AD43 E3S-AD93
E3S-AD41 E3S-AD91
E3S-AD42 E3S-AD92
Wavelength of LED light source
700 nm (red) 880 nm (infrared) 700 nm (red) 880 nm (infrared)
Sensitivity adjustment Two-turn (endless) sensitivity adjustor with indicator Self-diagnostic functions Self-diagnostic output,
External diagnostic input
Self-diagnostic output
Timer 0 to 100 ms OFF-delay varable adjustor Turbo function Yes (with turbo switch) --­Method of connection Prewired Weight 60 g Operation mode Dark-ON or Light-ON (switchable) Output Open collector current output (NPN or PNP) Circuit protection Load short-circuit protection, reverse connection protection, mutual interference prevention (except for
through-beam models) functions
Indicators Light indicator (red) and stability indicator (green); emittion indicator (red) for the emitter of the through-beam
model
Materials Case:
Lens: Mounting bracket:
Polybutylene terephtalate Denaturated polyallalate Stainless steel (SUS304)
Attachments Mounting bracket, sensitivity adjustor knob, screws, sensitivity adjustor cover, close-mounting plate (only for
Sensors with connector terminals) and reflector (E39-R1: only for retroreflective Sensors)
Page 5
A-235E3S-A
E3S-A
Ratings / Characteristics
Item Through-beam Retroreflective Diffuse reflective
E3S-AT11, 16, 21, 31, 36, 41, 61, 66,
71, 81, 86, 91
E3S-AR11, 16, 21,
31, 36, 41, 61, 66,
71, 81, 86, 91
E3S-AD23, 43,
73, 93
E3S-AD13, 18,
33, 38, 63, 68,
83, 88
E3S-AD11, 16,
21, 31, 36, 41, 61, 66, 71, 81,
86, 91
E3S-AD12, 17,
22, 32, 37, 42, 62, 67, 72, 82,
87, 92 Power supply voltage 10 to 30 V DC, ripple: 10 % max. Current consumption 40 mA max. (emitter
and receiver) plus approx. 15 mA with turbo function
30 mA max. plus ap­prox. 15 mA with tur­bo function
35 mA max. 30 mA max.
plus approx. 15 mA with tur­bo function
35 mA max.
Rated sensing distance
White mat paper
0 to 7 m 0.1 to 2 m 0.1 to 10 cm 0.1 to 20 cm 0 to 70 cm
Black mat paper
0 to 7 m 0.1 to 2 m 0.3 to 2.5 cm 0.5 to 20 cm 0.15 to 33 cm
Standard sensing ob­ject (white mat paper)
7 mm min. 30 mm min. 10 x 10 cm 20 x 20 cm
Variation in sensing distance
---
30 %
/
-0 %
max.
Hysteresis --- 20 % max. 10 % max. 20 % max. Sensing distance with
attachment
E39-E6: 2.4 m 2-mm slit: 2.5 m 1-mm slit: 1.1 m
0.5-mm slit: 0.5 m
E39-R3: 10 to 130 cm E39-R4: 7 to 60 cm E39-RSA: 10 to 60 cm E39-RSB: 10 to 30 cm
---
Min. sensing object without slit: 2.0 mm
2-mm slit: 0.8 mm 1-mm slit: 0.4 mm
0.5-mm slit: 0.2 mm
E39-R1 Reflector: 10 mm E39-R3: 3 mm E39-R4: 1.0 mm
---
Difference in direction between optical axis and mounting direc­tion
±2° max. (checked along extended line in the mounting direction)
±2° max.
Response time 0.5 ms max. for both operation and release Control output 30 VDC, 100 mA max. (residual voltage: 1 V max.) Open collector (residual voltage: 0.4 V max. at 16 mA) Self-diagnostic output Only Sensors with self-diagnostic function: 50 mA max, 30 VDC (residual voltage: 1 V max.), open collector (re-
sidual voltage: 0.4 V max. 16 mA)
External diagnos­tic input
Input Voltage
With emitter OFF:
NPN: 0 V short-circuit or 1.5 V max. (push
current: 1 mA max.)
PNP: DC short-circuit or –1.5 V DC max.
(pull current: 3 mA max.)
With emitter ON: NPN/PNP
Open (max. input voltage: 30 V max. with
0.1 mA current leakage)
---
Re­sponse time
0.5 ms max.
Ambient illumination Incandescent lamp: Illumination on optical spot: 5,000 lx max.
Sunlight: Illumination on optical spot:10,000 lx max.
Ambient temperature Operating: –25°C to 55°C (with no icing)
Storage: –40°C to 70°C (with no icing)
Ambient humidity Operating: 35% to 85%
Storage: 35% to 95% Insulation resistance 20 MW min. (at 500 V DC) Dielectric strength 1,000 V AC, 50/60 Hz for 1 min Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude (30G) 2 hrs each in three directions Shock resistance Destruction: Approx. 50G 3 times each in three directions Enclosure ratings IEC: IP67; NEMA: 4X
Page 6
A-236 Standard Photoelectric Sensors
Engineering Data
Parallel Operating Range (Typical)
Operating Range (Typical)
E3S-AT@1E3S-AD@ (Left and Right) E3S-AD@ (Up and Down)
Sensing Distance vs. Object Size Excess Gain vs. Set Distance
E3S-AD@ E3S-AT@1 (Typical) E3S-AD@1, -AD@2, -AD@3, -AD@8
(Detection of White Paper)
Reflector Parallel Movement
E3S-AR@1 (With Reflector E39-R1) E3S-AD@1, -AD@2, -AD@3, -AD@8
(Detection of White Paper)
E3S-AR@1 (Typical)
Parallel operating range Y (cm)
2 4 6
8
X
Y
Distance X (m)
Operating position Y (cm)
Sensing object
Y
X
Distance X (cm)
E3S-AD@3/@8
E3S-AD@2
E3S-AD@1
Operating position Y (cm)
E3S-AD@1
E3S-AD@2
Distance X (cm)
E3S-AD@3/@8
Sensing distance (cm)
E3S-AD@2
E3S-AD@1
E3S-AD@3/@8
OFF ON
OFF ON
OFF ON
Size of object (cm)
Excess gain ratio
Distance (m)
Excess gain ratio
Distance (cm)
Sensing object: white (E3S-AD@2: 20 x 20 cm E3S-AD@1: 10 x 10 cm E3S-AD@3/@8: 10 x 10 cm)
E3S-AD@2
E3S-AD@3/@8
Operating level
E3S-AD@1
Parallel operating range Y (cm)
X
Y
Distance X (m)
Excess gain ratio
Distance (m)
Operating level
Excess gain ratio
Distance (cm)
Sensing object: black (E3S-AD@2: 20 x 20 cm E3S-AD@1: 10 x 10 cm E3S-AD@3/@8: 10 x 10 cm)
Operating level
E3S-AD@1
E3S-AD@3/@8
E3S-AD@2
Page 7
A-237E3S-A
E3S-A
Operation
Output Circuits
Type Model Mode switch Output transistor Output circuit
NPN E3S-AT11
E3S-AT16 E3S-AT61 E3S-AT66 E3S-AR11 E3S-AR16 E3S-AR61 E3S-AR66 E3S-AD13 E3S-AD63 E3S-AD18 E3S-AD68 E3S-AD11 E3S-AD16 E3S-AD61 E3S-AD66 E3S AD12 E3S-AD17 E3S-AD62 E3S AD67
Light ON ON when light is re-
ceived
Dark ON ON when light is
not received
E3S-AT21 E3S-AT71 E3S-AD23 E3S-AD73 E3S-AD21 E3S-AD71 E3S-AD22 E3S-AD72
Light ON ON when light is re-
ceived
Dark ON ON when light is
not received
E3S-AR21 E3S-AR71
Light ON ON when light is re-
ceived
Dark ON ON when light is
not received
Emitter E3S-AT11/AT16/ AT61/AT66
10 to 30 VDC
Brown
Blue
Main circuit
Emission (Red)
Load
10 to 30 VDC
Z
D
Light Stability
(Red)
(Green)
Main circuit
Brown
Black
Blue
100 mA max.
Z
D
: VZ = 39 V
(relay)
Connector Type Emitter
Reflective/Receiver
Pin No. 2 is open.
Load
+ V
0 V
+ V
0 V
Output
(Relay)
Emitter E3S-AT21/AT71
10 to 30 VDC
0 V
Emission (Red)
Main circuit
Brown
Pink
Blue
External-diagnostic input
Indicator (red)
ON OFF
External diagnostic input
ON OFF
LED for emitter
ON OFF
Z
D
ZD
10 to 30 VDC
Light Stability
(Red)
(Green)
Main circuit
100 mA max.
50 mA max.
Brown
Black
Blue
Load (relay)
Z
D: VZ = 39 V
Self-diagnostic output
Load (relay)
Control output
Orange
(Red)
(Green)
Light
Black
Pink
Orange
10 to 30 VDC
100 mA max.
50 mA max.
12 K
Stability
Blue
Brown
Load (relay)
Control output
Self-diagnostic output
External-diag nostic input
Main circuit
Z
D
ZD
Load (relay)
Z
D: VZ = 39 V
Page 8
A-238 Standard Photoelectric Sensors
PNP E3S-AT31
E3S-AT36 E3S-AT81 E3S-AT86 E3S-AR31 E3S-AR36 E3S-AR81 E3S-AR86 E3S-AD33 E3S-AD83 E3S-AD38 E3S-AD88 E3S-AD31 E3S-AD36 E3S-AD81 E3S-AD86 E3S AD32 E3S-AD37 E3S-AD82 E3S AD87
Light ON ON when light is re-
ceived
Dark ON ON when light is
not received
E3S-AT41 E3S-AT91 E3S-AD43 E3S-AD93 E3S-AD41 E3S-AD91 E3S-AD42 E3S-AD92
Light ON ON when light is re-
ceived
Dark ON ON when light is
not received
E3S-AR41 E3S-AR91
Light ON ON when light is re-
ceived
Dark ON ON when light is
not received
Type Model Mode switch Output transistor Output circuit
Emitter E3S-AT31/AT36/ AT81/AT86
Main circuit
Brown
Blue
10 to 30 VDC
Emission (Red)
Light
Stability
(Red)
Main circuit
Z
D
Brown
Blue
Black
Control output
100 mA max.
Load
10 to 30 VDC
Z
D : VZ = 39 V
(Green)
(relay)
Connector Type Emitter
Reflective/Receiver
Pin No. 2 is open.
+ V
0 V
+ V
0 V
Output
Load
(relay)
Emitter E3S-AT41/AT91
Indicator (red)
ON OFF
External diagnostic input
ON OFF
LED for emitter
ON OFF
Pink
Blue
Brown
Emission (Red)
Main circuit
10 to 30 VDC
External-diagnostic input
0 V
Light
Stability
(Green)
(Red)
Main circuit
Z
D
Z
D
50 mA max.
100 mA max.
Black
Orange
Blue
Brown
Load (relay)
Control output
Self-diagnostic output
10 to 30 VDC
Load (relay)
Z
D
: VZ = 39 V
Black
Pink
Orange
Blue
Brown
50 mA max.
100 mA max.
Z
D
ZD
Load (relay)
Control output
10 to 30 VDC
4.4K
Main circuit
(Green)
(Red)
Light Stability
Load (relay)
Z
D: VZ = 39 V
External-diag­nostic input
Self-diagnos­tic output
Page 9
A-239E3S-A
E3S-A
Timing Charts
Type Model Mode switch Output transistor Timing chart
NPN E3S-AT11
E3S-AT16 E3S-AT61 E3S-AT66 E3S-AR11 E3S-AR16 E3S-AR61 E3S-AR66 E3S-AD13 E3S-AD63 E3S-AD18 E3S-AD68 E3S-AD11 E3S-AD16 E3S-AD61 E3S-AD66 E3S-AD12 E3S-AD17 E3S-AD62 E3S-AD67
Light ON ON when light is re-
ceived.
Dark ON ON when light is
not received.
E3S-AT21 E3S-AT71 E3S-AD23 E3S-AD73 E3S-AD21 E3S-AD71 E3S-AD22 E3S-AD72 E3S-AR21 E3S-AR71
Light ON ON when light is re-
ceived.
Dark ON ON when light is
not received.
Light indicator (Red)
ON OFF
Output transistor
Load (relay)
Operate Release
ON OFF
(Between brown and black)
Light received Light not received
(Between brown and black)
Light indicator (Red)
ON OFF
Output transistor
Load (relay)
Operate Release
ON OFF
Light received Light not received
T
(Between brown and black)
Light indicator (Red)
ON OFF
Output transistor
Load (relay)
Operate Release
ON
OFF
Light received Light not received
T: Off-delay timer (0 to 100 ms)
T
(Between brown and black)
Light indicator (Red)
ON OFF
Output transistor
Load (relay)
Operate Release
ON
OFF
Light received Light not received
T: Off-delay timer (0 to 100 ms)
T: Off-delay timer (0 to 100 ms)
Page 10
A-240 Standard Photoelectric Sensors
PNP E3S-AT31
E3S-AT36 E3S-AT81 E3S-AT86 E3S-AR31 E3S-AR36 E3S-AR81 E3S-AR86 E3S-AD33 E3S-AD83 E3S-AD38 E3S-AD88 E3S-AD31 E3S-AD36 E3S-AD81 E3S-AD86 E3S-AD32 E3S-AD37 E3S-AD82 E3S-AD87
Light ON ON when light is re-
ceived.
Dark ON ON when light is
not received.
E3S-AT41 E3S-AT91 E3S-AD43 E3S-AD93 E3S-AD41 E3S-AD91 E3S-AD42 E3S-AD92 E3S-AR41 E3S-AR91
Light ON ON when light is re-
ceived.
Dark ON ON when light is
not received.
Type Model Mode switch Output transistor Timing chart
(Between blue and black)
Light indicator (Red)
ON OFF
Output transistor
Load (relay)
Operate Release
ON OFF
Light received Light not received
(Between blue and black)
Light indicator (Red)
ON OFF
Output transistor
Load (relay)
Operate Release
ON OFF
Light received Light not received
T
(Between blue and black)
Light indicator (Red)
ON OFF
Output transistor
Load (relay)
Operate Release
ON
OFF
Light received Light not received
T: Off-delay timer (0 to 100 ms)
T
(Between blue and black)
Light indicator (Red)
ON OFF
Output transistor
Load (relay)
Operate Release
ON OFF
Light received Light not received
T: Off-delay timer (0 to 100 ms)
Page 11
A-241E3S-A
E3S-A
Self-diagnostic Function
With this function, the E3S-A checks changes in environmental conditions (especially a change in the ambient temperature) and self-diagnoses the resistance against the changes. The result is shown by the indicators or an output signal.
External Diagnostic Input Function
To switch the emission off, short-circuit the pink and the blue cords of the emitter of the E3S-AT or the E3S-AR with the NPN output feature. For the E3S-AT or the E3S­AR with the PNP output feature, short-circuit the pink and the brown cords. With this function, the operating status can be checked before operation.
Amount of
incident light
Green indicator Indicator Incident light
indicator (red)
Self-diagnostic
function
Self-diagnostic example
1.2 or more Stable operating
state with inci­dent light: Stable operation is ex­pected in the rat­ed temperature range with the green indicator ON.
With light inci­dent (red indica­tor: ON)
--- ---
1.0 to 1.2 Conditional oper-
ating state with incident light: Stable operation is expected if the temperature fluc­tuation is within ±10% of the pri­mary tempera­ture.
The self-diag­nostic alarm output alerts the user to this state if it contin­ues for 0.3 s.
0.8 to 1.0 Without light inci-
dent (red indica­tor: OFF)
0.8 or less Stable operating
state with no inci­dent light: Stable operation is ex­pected in the rat­ed temperature range with the green indicator ON.
--- ---
Green Red
Green Red
The optical axis misaligned by vibration.
Light decreased by dust.
Dust
Green Red
With the influence of external noise
Sensing object
Noise
Sensing object
With light leakage (through-beam and retroreflective Sensors)
Light reflected from the floor or the back­ground (diffuse reflective Sensors)
Green Red
With emission
Brown + V
Brown + V
Blue 0 V
Blue 0 V
OFF (with PNP output)
OFF (with NPN output)
Pink (External­diagnostic input)
ON (with PNP output)
ON (with NPN output)
Pink (External­diagnostic input)
E3S-AT@/E3S-AR@ emitter
E3S-AT@/E3S-AR@ emitter
Without emission
Page 12
A-242 Standard Photoelectric Sensors
The sensor is normal if the control output var­ies when the self-diagnostic external input is ON and OFF. The sensor is abnormal if the control output does not vary when the self-di­agnostic external input is turned ON or OFF.
Note:Before using the self-diagnostic external input func­tion, the incident light beam to the sensor must not be blocked by an object.
Timer and Turbo Switch (Sensors with Self-diagnostic Output Function)
The E3S-A Sensor equipped with the self-diagnostic feature incorporates an OFF-delay timer that can be adjusted within a range of 0 to 100 ms.
The emitter of the through-beam sensor with the self-diagnos­tic feature incorporates a turbo switch. When this switch is on, the intensity of the red LED light source can be increased to
make a brighter spot. The OFF-delay time adjustor of the ret­roreflective and the 20-cm diffuse reflective sensor is used as a turbo switch. When the adjustor is pressed, it functions as a turbo switch to automatically increase the power of the light source to create a brighter light spot. Do not press the adjustor when turning it
Sensitivity Adjustment (Reflective Sensors)
Unlike conventional photoelectric sensors, the variation in the sensitivity of E3S photoelectric sensors is minimal. This means the sensitivity can be adjusted on only a single photo­electric sensor, and then the adjustors on the other photoelec­tric sensors can be set to the same scale position. There is no need to adjust the sensitivity of each photoelectric sensor in­dividually.
Indicator
ON OFF
External diagnostic input
ON OFF
LED for emitter
ON OFF
E3S-AT@/E3S-AR@ Emitter
Indicator
Main circuit
Brown
Blue
Pink
10 to 30 VDC
(with PNP output)
(with NPN output)
External-diagnostic input
0 V
Item Position A Position B Setting
Sensing condition
---
Sensivity adjustor
Indicators
Procedure Locate a sensing object at the sensing
distance, set the sensitivity adjustor to the minimum scale position, and grad­ually increase sensitivity by turning the sensitivity adjustor clockwise until the incident light indicator (red LED) is ON. Position A is where the indicator has turned ON. Regard the maximum scale position as Position A if the indicator does not turned ON at full sensitivity.
Remove the sensing object and gradu­ally decrease sensitivity by turning the sensitivity adjustor counterclockwise from the maximum scale position until the incident light indicator (red LED) is OFF. Position B is where the indicator has turned off. Regard the minimum scale position as Position B if the indi­cator does not turned ON at minimum sensitivity.
Set the sensitivity indicator to the posi­tion between Positions A and B (in some cases, Positions A and B are op­posite of the above example). The pho­toelectric sensor will then work normally if the stability indicator (green) is lit with and without the sensing ob­ject. If it is not lit, stable operation can­not be expected, in which case a different detection method must be ap­plied.
Photoelectric sensor
Sensing object
Sensing object
Photoelectric sensor
A
Min Max
Min Max
B
B
Min Max
A
OFF ON
STABILITY (green)
LIGHT (red)
OFF OFF
STABILITY (green)
LIGHT (red)
OFF ON
STABILITY (green)
LIGHT (red)
Page 13
A-243E3S-A
E3S-A
Turbo Function (Turbo Switch)
With the turbo function switched ON, the light spot is visible even at a dis­tance of 20 cm, making it easy to check the sensing position and the angle of the optical axis.
1. After using the turbo function, read­just the OFF-delay time that had been set, since the OFF-delay time could have been changed when the turbo switch (which is on the OFF-delay time adjustor) was pressed.
2. Press the OFF-delay time adjustor to switch ON the turbo function with a maximum force of 1 kg and within a maximum period of 3 mins. (The photoelectric sensor, however, will not malfunction even if the turbo function is switched on for more than 3 mins.)
Operating Mode Selection
As shown in the following illustration, the E3S-A has an oper­ating mode selector on the panel where the Receiver connec­tor is located. With this operating mode selector, the E3S-A is in either dark-ON or light-ON mode.
Normal Operating Condition
Adjustor cap
Sensitivity adjustor
PUSH
With Turbo Switch ON
The turbo function is effective with the turbo switch pressed, and the function is reset automatically when released.
The OFF-delay time adjustor is used as a turbo switch (black)
Operating mode selector (black)
Dark-ON Light-ON
Page 14
A-244 Standard Photoelectric Sensors
Dimensions
Sensors
Prewired Type
E3S-AT11, E3S-AT31 (Receiver)
Mounting Holes
E3S-AT11, E3S-AT31 (Emitter)
Sensitivity adjustor (white)
Polyvinyl chloride-covered cord, 4-mm dia. (0.12-mm x 18), 4 cores, Standard length: 2 m
Light indicator (red)
Stability indicator (green)
Two mounting holes
Lens (7 x 7)
Optical axis
Two, M3 x 12 screws
12.4 12
12.9
7
(4)
16.5
16.9
10.7
3.2
4.8
5
10.5
20 30
7.2
3.2
7.2
21
8
1.2
5.5
10.7
16.2
29.2
1.3
A (see note)
40
Mode Selector (black)
Dark-ON Light-ON
DL
A (see note)
Mounting Holes
20
Two, M3 holes
Mounting Holes
Mode Selector (black)
Dark-ON Light-ON
DL
A (see note)
20
Two, M3 holes
12.4
12
10.7
40
17.8
3.2
4.8
5
20 30
7.2
3.2 7.2
(4)
1.3
29.2
16.2
5.5
10.7
1.2
8
21
Light indicator (red)
Two mounting holes
Two, M3 x 12 screws
Lens (7 x 7)
Optical axis
Polyvinyl chloride-covered cord , 4-mm dia. (0.12-mm x 18), 2 cores, Standard length:2 m
16.5
16.9
10.5
A (see note)
Note: The mounting bracket can be attached to side A.
Note: The mounting bracket can be attached to side A.
Page 15
A-245E3S-A
E3S-A
E3S-AT21, E3S-AT41 (Receiver)
Light indicator (red)
Sensitivity adjustor (white)
Time adjustor (black)
2-m polyvinyl chloride-covered cord, 4-mm dia. (0.12-mm x 18), 4 cores, Standard length: 2 m
Stability indicator (green)
Two mounting holes
Lens (7 x 7)
Optical axis
Two, M3 x 12 screws
12.4 12
12.9 7
40
5.5
(4)
16.5
16.9
10.7
3.2
4.8
5
10.5
20 30
7.2
3.2
7.2
21
8
1.2
10.7
5.5
16.2
29.2
1.3
A (see note)
Mounting Holes
Mode Selector (black)
Dark-ON Light-ON
DL
A (see note)
20
Two, M3 holes
E3S-AT21, E3S-AT41 (Emitter)
Lens (7 x 7)
Optical axis
Light indicator (red)
Two, M3 x 12 screws
Turbo Switch
12.4
16.5
12
16.5
10.7
10.5
5
4.8
3.2
12.9
40 (4)
3.2 7.2
7.2
20 30
1.3
29.2
16.2
5.5
10.7
1.2
8
27
Two mounting holes
Polyvinyl chloride-covered cord, 4-mm dia. (0.12-mm x 18), 2 cores, Standard length:2 m
12.5
A (see note)
Mode Selector (black)
Dark-ON Light-ON
DL
A (see note)
20
Two, M3 holes
Mounting Holes
Note: The mounting bracket can be attached to side A.
Note: The mounting bracket can be attached to side A.
Page 16
A-246 Standard Photoelectric Sensors
E3S-AR11, E3S-AR31 E3S-AR21, E3S-AR41
21
11.5
1.2
10.7
19.7
29.2
1.3
20 30
10.5
5
3.2
4.8
3.2 7.2
(9)
(4) (see note 2)
42.3
5.5
7
15.2
2.3
12.4
16.5
12
16.9
10.7
Receiver
Emitter
OFF-delay time adjustor/turbo switch (black) (see Note 1) Turn to adjust the OFF-delay time: push to switch turbo function ON
Note: 1. For E3S-AR21 and
E3S-AR41 only.
2. 9 mm for E3S-AR21 and E3S-AR41
Lens (7 x 14)
Optical axis
Light indicator (red)
Sensitivity adjustor (white)
Polyvinyl chloride-covered cord, 4-mm dia. (0.12-mm x 18), 5 cores (E3S-AR21, -41), 3 cores (E3S-AR11, 31), Standard length: 2 m
Stability indicator (green)
Two mounting holes
Two, M3 x 12 screws
9
A (see note)
7.2
Mounting Holes
12.4
12
16.5
16.9
10.7
12.9
7
40
(4)
3.2
7.2
7.2
20 30
3.2
4.8
5
10.5
11.5
1.2
10.7
9
19.7
29.2
1.3
Light indicator (red)
Sensitivity adjustor (white)
Polyvinyl chloride-covered cord, 4-mm dia. (0.12-mm x 18), 3 cores, Standard length: 2 m
Stability indicator (green)
Two mounting holes
Lens (7 x 14)
Receiver
Optical axis
Emitter
Two, M3 x 12 screws
21
A (see note)
Mounting Holes
20
Two, M3 holes
Mode Selector (black)
Dark-ON Light-ON
DL
A (see note)
20
Two, M3 holes
Mode Selector (black)
Dark-ON Light-ON
DL
A (see note)
Note: The mounting bracket can be attached to side A.
Note: The mounting bracket can be attached to side A.
E3S-AD11, E3S-AD31 E3S-AD13, E3S-AD31 E3S-AD12, E3S-AD32
Page 17
A-247E3S-A
E3S-A
E3S-AD21, E3S-AD41 E3S-AD23, E3S-AD43 E3S-AD22, E3S-AD42
E3S-AT61, E3S-AT81 (Receiver)
11.5
1.2
10.7
9
19.7
29.2
12.4
16.5
12
16.9
10.7
12.9 7
40
5.5
(4)
3.2 7.2
30
20
5
1.3
3.2
4.8
Light indicator (red)
Sensitivity adjustor (white)
OFF-delay time adjustor/turbo switch (black) (see Note) Turn to adjust the OFF-delay time: push to switch turbo function
Polyvinyl chloride-covered cord, 4-mm dia. (0.12-mm x 18), 4 cores, Standard length: 2 m
Stability indicator (green)
Two mounting holes
Lens (7 x 14)
Receiver
Optical axis
Emitter
Two, M3 x 12 screws
21
Note: Turbo switch is only for
E3S-AD21 and E3S-AD41.
A (see note)
10.5
7.2
Mounting Holes
Use these two holes for mounting.
Lens (7 x 7)
Optical axis
Polyvinyl chloride-covered cord, 4-mm dia. (0.12-mm x 18), 4 cores, Standard length: 2 m
Four mounting holes
Stability indicator (green)
Light indicator (red)
Sensitivity adjustor (white)
Two, M3 x 12 screws
12.4 12
16.5
16.9
10.7
7.2
13.5 8.3
40 (4)
3.1
3.6
41.7
7.2
20
21
3.6
1.2 10.7
29.2
1.3
10.5
20+0.2
7
A (see note)
Mounting Holes
20
Two, M3 holes
Mode Selector (black)
Dark-ON Light-ON
DL
A (see note)
20
Two, M3 holes
Mode Selector (black)
Dark-ON Light-ON
DL
A (see note)
Note: The mounting bracket can be attached to side A.
Note: The mounting bracket can be attached to side A.
Page 18
A-248 Standard Photoelectric Sensors
E3S-AT61, E3S-AT81 (Emitter)
Mounting Holes
20
Two, M3 holes
Mode Selector (black)
Dark-ON Light-ON
DL
A (see note)
12.4 12
16.5
16.9
7.2
10.7
40
8.5
29.2
8.3
3.1
3.6
1.2
1.3
13.5
41.7
7.2
20
21
10.7
10.5 20+0.2
Lens (7 x 7) Optical axis
Two, M3 x 12 screws
Four mounting holes
Light indicator (red)
Polyvinyl chloride-covered cord, 4-mm dia. (0.12-mm x 18), 4 cores, Standard length: 2 m
Use these two holes for mounting.
(4)
A (see note)
E3S-AT71, E3S-AT91 (Receiver)
21
3.6
7
5.5
10.7
29.2
1.3
10.5 20+0.2
12.4 12
16.5
16.9
10.7
7.2
13.5
8.3
40
(4)
20
41.7
Lens (7 x 7)
Optical axis
Polyvinyl chloride-covered cord, 4-mm dia. (0.12-mm x 18), 4 cores, Standard length: 2 m
Use these two holes for mounting.
Four mount
ing holes Stability indicator (green)
Light indicator (red)
Sensitivity adjustor (white)
Time adjustor (black)
Two, M3 x 12 screws
3.1
3.6
7.2
A (see note)
1.2
Mounting Holes
20
Two, M3 holes
Mode Selector (black)
Dark-ON Light-ON
DL
A (see note)
Note: The mounting bracket can be attached to side A.
Note: The mounting bracket can be attached to side A.
Page 19
A-249E3S-A
E3S-A
E3S-AT71, E3S-AT91 (Emitter)
E3S-AR61, E3S-AR81 E3S-AR71, E3S-AR91
Mounting Holes
23.3
5.9
7
5.5
12
10.7
31.5
10.5 20+0.8
4.7
3.1
3.6
20
(4) (see note 2)
40
13.5
12.4
16.5
12
16.9
10.7
7.2
(9)
Receiver
Lens (7 x 14)
Optical axis
Emitter
Polyvinyl chloride-covered cord, 4-mm dia. (0.12-mm x 18), 5 cores (E3S-AR71/-AR91), 3 cores (E3S-AR61/-AR81), Standard length: 2 m
Use these two holes for mounting.
Four mounting holes
Light indicator (red)
Stability indicator (green)
Sensitivity adjustor (white)
OFF-delay time adjus tor/turbo switch (black) (see note 1) Turn to adjust the OFF­delay time: push to switch turbo function
Two, M3 x 12 screws
8.3
1.3
A (see note 3)
7.2
Mounting Holes
20
Two, M3 holes
Mode Selector (black)
Dark-ON Light-ON
DL
A (see note)
20
Two, M3 holes
Mode Selector (black)
Dark-ON Light-ON
DL
12.4 12
16.5
16.9
7.2
10.7
40
8.3
3.1
3.6
13.5
41.7
7.2
20
Lens (7 x 7) Optical axis
Four mounting holes
Polyvinyl chloride-covered cord , 4-mm dia. (0.12-mm x 18), 2 cores, Standard length: 2 m
Use these two holes for mounting.
(4)
12.5
3.6
21
29.2
10.7
10.5
1.3
1.2
Two, M3 x 12 screws
20+0.2
Light indicator (red)
Turbo switch
A (see note)
Note: 1. Turbo switch is only for E3S-AR71 and E3S-AR91.
2. 9.7 mm for E3S-AR71/-AR91.
3. The mounting bracket can be attached to side A.
Note: The mounting bracket can be attached to side A.
A (see note)
Page 20
A-250 Standard Photoelectric Sensors
E3S-AD61, E3S-AD81 E3S-AD63, E3S-AD83 E3S-AD62, E3S-AD82
E3S-AD71, E3S-AD91 E3S-AD73, E3S-AD93 E3S-AD72, E3S-AD92
1.3
12.4
16.5
12
16.9
10.7
7.2
17
40
4.8
(4)
41.7
20
3.1
3.6
10.5
20+0.2
29.2
10.7
1.2
21
3.6
7
Receiver
Lens (7 x 14)
Optical axis
Emitter
Polyvinyl chloride-covered cord, 4-mm dia. (0.12-mm x 18), 3 cores, Standard length: 2 m
Use these two holes for mounting.
Four mounting holes
Stability indicator (green)
Light indicator (red)
Sensitivity adjustor (white)
Two, M3 x 12 screws
7.2
A (see note)
Mounting Holes
21
3.6
7
3.5
12
10.7
29.2
10.5
20+0.2
12.4
14.5
12
16.9
10.7
7.2
41.7
20
17
4.8
40
(4)
Receiver
Lens (7 x 14)
Optical axis
Emitter
Polyvinyl chloride-covered cord, 4-mm dia. (0.12-mm x 18), 4 cores, Standard length: 2 m
Use these two holes for mounting.
Four mounting
holes Stability indicator (green)
Light indicator (red)
Sensitivity adjustor (white)
OFF-delay time adjustor/turbo switch (black) (see note 1) Turn to adjust the OFF-delay time: push to switch turbo function
Two, M3 x 12 screws
3.1
3.6
7.2
1.3
A (see note)
Mounting Holes
20
Two, M3 holes
Mode Selector (black)
Dark-ON Light-ON
DL
A (see note)
20
Two, M3 holes
Mode Selector (black)
Dark-ON Light-ON
DL
A (see note)
Note: 1. Turbo switch is only for E3S-AD71 and E3S-AD91.
2. The mounting bracket can be attached to side A.
Note: The mounting bracket can be attached to side A.
Page 21
A-251E3S-A
E3S-A
Connector Type
E3S-AT16, E3S-AT36 (Receiver)
12.4 12
16.5
16.9
10.7
12.9 7
40 (10)
3.2
7.2
7.2
20
30
10.5
5
3.2
4.8
21
8
1.2
10.7
5.5
16.2
29.2
1.3
Lens (7 x 7)
Optical axis
Two, M3 x 12 screws
Sensitivity adjustor (white)
Connector M12
Stability indicator (green)
Two mounting holes
Light indicator (red)
A (see note)
Light-ON
Dark-ON
Mode Selector (black)
A (see note)
Mounting Holes
Mounting Holes
20
Two, M3 holes
20
Two, M3 holes
Light-ON
Dark-ON
Mode Selector (black)
A (see note)
E3S-AT16, E3S-AT36 (Emitter)
1212.4
Lens (7 x 7) Optical axis
5
16.5
16.9
10.7
10.5 30
20
7.2
7.23.2
(10)
40
17.8
4.8
3.2
21
29.2
16.2
10.7
5.5
1.2
1.3
8
Connector M12
Two mounting holes
Two, M3 x 12 screws
Light indicator (red)
A (see note)
Note: The mounting bracket can be attached to side A.
Note: The mounting bracket can be attached to side A.
Page 22
A-252 Standard Photoelectric Sensors
E3S-AR16, E3S-AR36
21
11.5
1.2 10.7
19.8
29.29
1.3
42.3
15.2
2.3
7
(10)
12.4
12
16.5
16.9
10.7
30
20
7.2
3.2
7.2
5
3.2
4.8
10.5
Light indicator (red)
Sensitivity adjustor (white)
Connector M12
Stability indicator (green)
Two mounting holes
Lens (7 x 14)
Receiver
Optical axis
Emitter
Two, M3 x 12 screws
A (see note)
Mounting Holes
20
Two, M3 holes
Light-ON
Dark-ON
Mode Selector (black)
A (see note)
E3S-AD16, E3S-AD36 E3S-AD18, E3S-AD38 E3S-AD17, E3S-AD37
5
10.5
21
14.2 12
16.5
16.9
10.7
40
12.9
7
(10)
7.2
3.2
30
20
3.2
4.8
11.5
1.2
10.7
19.7
29.2
9
1.3
Light indicator (red) Sensitivity adjustor (white)
Connector M12
Stability indicator (green)
Two mounting holes
Lens (7 x 14)
Receiver
Optical axis
Emitter
Two, M3 x 12 screws
7.2
A (see note)
20
Two, M3 holes
Mounting Holes
Light-ON
Dark-ON
Mode Selector (black)
A (see note)
Note: The mounting bracket can be attached to side A.
Note: The mounting bracket can be attached to side A.
Page 23
A-253E3S-A
E3S-A
E3S-AT66, E3S-AT86 (Receiver)
Spacer (attachment) (Attach the spacer or the plug cannot be connected.)
Lens (7 x 7)
Optical axis
Connector M12
Use these two holes for mounting.
Four mounting holes
Stability indicator (green)
Light indicator (red)
Sensitivity adjustor (white)
Two, M3 x 12 screws
14.9
12
16.5
19.4
10.7
7.2
13.5 8.3
40
(10)
3.1
3.6
41.7
20
7.2
21
3.6
7
1.2
10.7
29.2
1.3
10.5
20+0.2
A (see note)
20
Two, M3 holes
Mounting Holes
Light-ON
Dark-ON
Mode Selector (black)
A (see note)
E3S-AT66, E3S-AT86 (Emitter)
20
Two, M3 holes
Mounting Holes
Light-ON
Dark-ON
Mode Selector (black)
A (see note)
Lens (7 x 7) Optical axis
Four mounting holes
Light indicator (red)
Use these two holes for mounting.
8.5
(10)
40
13.5
14.9
16.5
12
19.4
10.7
7.2
3.1
3.6
20
7.2
41.7
29.2
21
10.7
1.2
1.3
10.5
20+0.2
Connector M12
Spacer (attachment) (Attach the spacer or the plug cannot be connected.)
Two, M3 x 12
8.3
A (see note)
Note: The mounting bracket can be attached to side A.
Note: The mounting bracket can be attached to side A.
Page 24
A-254 Standard Photoelectric Sensors
E3S-AR66, E3S-AR86
E3S-AD66, E3S-AD86 E3S-AD68, E3S-AD88 E3S-AD67, E3S-AD87
14.9
17
40 (10)
20
3.1
3.6
41.7
7.2
10.7
16.5
12
19.4
3.6
7
21
1.2
10.7
29.2
1.3
10.5
20+0.2
Receiver
Lens (7 x 14)
Optical axis
Emitter
Connector M12
Use these two holes for mounting.
Four mounting holes
Stability indicator (green)
Sensitivity adjustor (white)
Two, M3 x 12 screws
Spacer (attachment) (Attach the spacer or the plug cannot be connected.)
Light indicator (red)
A (see note)
7.2
14.9
16.5
12
19.4
10.7
7.2
40 (10)
20
41.7
3.1
3.6
17
3.6
7
21
1.2 10.7
29.2
1.3
10.5
Receiver
Lens (7 x 14)
Optical axis
Emitter
Connector M12
Use these two holes for mounting.
Four mounting holes
Stability indica tor (green)
Light indicator (red)
Sensitivity adjustor (white)
Two, M3 x 12 screws
Spacer (attachment) (Attach the spacer or the plug cannot be connected.)
20+0.2
A (see note)
7.2
Mounting Holes
Mounting Holes
20
Two, M3 holes
Light-ON
Dark-ON
Mode Selector (black)
A (see note)
20
Two, M3 holes
Light-ON
Dark-ON
Mode Selector (black)
A (see note)
Note: The mounting bracket can be attached to side A.
Note: The mounting bracket can be attached to side A.
Page 25
A-255E3S-A
E3S-A
Accessories
Plug (for E3S-A Connector type)
The XS2F-D421 Straight Cable Connector is also available. Refer to the output circuit diagram on page A-237.
Attachments
DC
6 dia.
5 dia.
14.6 dia.
Polyvinyl chloride-cov­ered cord, 0.5 mm
2 (oil-
proof), 3 cores, Stand­ard length: 2 m
Straight Type XS2F-D421-DC0-A
Cable
drawing
direction
No. of
conductors
Cord
length
Model
Straight 3 2 m XS2F-D421-DC0-A
4 XS2F-D421-D80-A 3 5 m XS2F-D421-GC0-A 4 XS2F-D421-G80-A
Standard Mounting Bracket (for E3S-A Horizontal Sensor) E39-L69
Stainless steel (SUS304)
3.2
5
20
+0.2
20+0.2 30
7.2
1.2
3.1
10.7
16.5
16.5
10.7
3.1
7.2
7.2
3.1
3.2
3.1
5
7.2
Standard Mounting Bracket (for E3S-A Vertical Sensor) E39-L70
Stainless steel (SUS304)
16.3 20
+0.2
7.2
1.2
3.1
10.7
16.5
16.5
3.1
7.2
7.2
3.1
41.7
3.1
7.2
10.7
2.05
2.05
2.05
31.7
+0.1
11.4
3.1
7.2
20
+0.2
16.3
Close Mounting Plate (for E3S-A Connector Type) E39-L60
(33)
20
11.75 5
2.5
3.4 dia.
3.4 dia.
2.5
11.75
6.5
6.5
5
Sensitivity Adjustor Knob (for E3S-A) E39-G2
8 dia.
0.8
1
(12.6)
7 dia.
Page 26
A-256 Standard Photoelectric Sensors
Two, 3.5 dia. holes
40.3 34
7
59.9 52
1.6
2.7
7.5
(62.1)
Retroreflector (Included with E3S-@R@@) E39-R1
Page 27
A-257E3S-A
E3S-A
Accessories (Order Separately)
20
18 11
3.1 3.1
63.8
(74.3)
10.5
9.4
3.2
3.2
7.2
9.5
20
34.5
3.2
3.1
7.2
2
Vertical Mounting Bracket (for E3S-A) E39-L59
Mounting Example of E3S-A on E39-L59
40
12
10.5 20
6.5 57.3
74.3
17
Mounting bracket (E39-L59)
Two mounting holes
15.7
3.6
7
5.5
21
3.2
34.5
20
3.2
3.2 6.2 18
1.3
10.5 20
Two, M3 x 12 screws
5
Page 28
A-258 Standard Photoelectric Sensors
Mounting Example of E3S-A on E39-L81
Stainless steel (SUS304)
Two mounting holes
Two,M3X12
E39-L81 Mounting Bracket
Lens
Slit (for E3S-A) E39-S46
11.6 A
9.7
13.6 or
11.1
21.4
2.1
6.8
Note: The width of A is 0.5 mm, 1 mm, or
2 mm depending on the model.
Filters for Mutual Interference Prevention (for E3S-A) E39-E6
(See note)
Stainless steel (SUS304)
Note: Two vertical filters and two horizontal filters are
sold together.
Page 29
A-259E3S-A
E3S-A
Mini-reflector E39-R4 Optical Axis Confirmation Reflector
(for E3S-A) E39-R5
13.7
4
2
9.7+0.1
23 19+0.1
2
Two, 2.2 dia.
1.4
4.9
4
Bracket to be at tached to the emitter panel of E3S-A
15.9
9.7
11.7
11.6
7.9
59.9 25
40.9
7.5
11.2
Small Reflector E39-R3
Adhesive tape
11
20
0.2
383425.4
1.2
Four, M3 holes
2.6
34.8
19.3
Page 30
A-260 Standard Photoelectric Sensors
E39-R3 - With Enclosed Mounting Bracket
29
4.5 6
3.4
145 13.7
R20
3.4
28
22.9
7
18.45
11
20
0.2
0.2
Two, 3.2 dia. holes
16
3.4
R25.4
1051.2
38
Two, M3
41.8
25.4+0.1
10.1 1.2
34
Reflecting Tape E39-RS1
Adhesive tape
Reflecting Tape E39-RS2
Adhesive tape
Page 31
A-261E3S-A
E3S-A
Note: The above reflector tapes are polarizing.
Installation
Connections (Without Self-diagnostic Function)
Load (Relay)
With Sensor Controller S3D2
Item E39-R3 E39-RS1 E39-RS2 E39-RS3 E39-R4 Directional angle 30° min. 2 to 20° Ambient temperature Operating: –25°C to 55°C
Storage: –40°C to 70°C
Operating: –25°C to 55°C Storage: 0°C to 40°C
Operating: –25°C to 55°C Storage: –40°C to 70°C
Ambient humidity Operating: 35% to 85%
Storage: 35% to 95%
Operating: 35% to 85% Storage: 35% to 85%
Operating: 35% to 85% Storage: 35% to 95%
Enclosure rating IP67
Reflecting Tape E39-RS3
Adhesive tape
Sensing method Through-beam Retroreflective / diffuse reflective
Connection method
* 10 to 30 V for the E3S-A ** If the load is a relay, insert a surge absorbing diode between the coils of the relay. *** The connection examples are for sensors with the NPN output.
Sensing method Through-beam Retroreflective / diffuse reflective
Connection method
*12 to 24 V 0 V
Brown
Blue
Emitter
Receiver
Load
**100 mA max.
*12 to
24 V
0 V
Brown
Blue
Black
0 V
*12 to 24 V
**
Load
100 mA max.
Blue
Brown
Black
Output
Emitter Receiver
Brown
Blue
Brown
Blue
Black
IN1
12 V 0 V
S3D2
Brown
Black
Blue
12 V 0 V
IN 1
S3D2
Page 32
A-262 Standard Photoelectric Sensors
Plug (for E3S-A with connector)
Internal Connection
External connection
Tightening Plug
Turn part B by hand (do not use a pliers or the plug will be damaged) and tighten it with part C so that length A is nearly zero. Part B must be tightened properly with part C, or other­wise part B could be loosen by vibration and the sensor will not maintain the specified enclosure ratings.
Note: Use the spacer (sold together) to mount the photoelectric sensor with or
without the enclosed mounting bracket (refer to Dimensions (page A-
244)).
Precautions
The supplied voltage must be within the rated voltage range. Unregulated full-or half-wave rectifiers must not be used as power supplies.
If the input/output lines of the photoelectric sensor are placed in the same conduit or duct as power lines or high-voltage lines, the photoelectric sensor could be induced to malfunc­tion, or even be damaged, by electrical noise. Either separate the wiring, or use shielded lines as input/output lines to the photoelectric sensor.
Do not use a hammer to hit the amplifier when mounting or the amplifier will loose watertightness.
Note the following when using the E39-R3, E39-RSA, or E39­RSB reflector (tape):
1. Before applying adhesive tape to the reflector, make sure that the reflector is free from oil or dust, or otherwise the ad­hesive tape will not stick to the reflector properly.
2. Do not cut the reflector or the reflector will loose watertight­ness.
3. Do not press the reflector with a metal object or a nail, or otherwise the reflector will not function properly.
Position of Optical Axis of Through-beam Model
Unlike conventional through-beam models, the E3S Through­beam Photoelectric Sensor incorporates 2 lenses. But the lens actually in use is the one marked with an arrow indicating the position of the optical axis. When using a slit, attach it to the lens marked with the arrow.
Position of Arrow Indicating Optical Axis
Item Color of cord Connection
pin No.
Application
For DC Brown 1 Power supply (+V)
Black 4 Output Blue 3 Power supply (-V)
Note: Pin No. 2 and 4 are connected internally.
Terminal No.
Brown Blue Black
NPN Output
PNP Output
Load
+ V
0 V
Output
Brown
Black
Blue
Plug
+ V
0 V
Load
Output
Brown
Black
Blue
Plug
(C)
(B)
(A)
Model Position of lens in use E3S-A (vertical) Top E3S-A (horizontal) Bottom
Unused lens
Lens actually in use (attach the slit to this lens)
Arrow indicating optical axis position
Page 33
A-263E3S-A
E3S-A
Adjustor Cap
In order to prevent the sensitivity or OFF-delay time that has been set from changing accidentally enclosed, cover the ad­justors with the adjustor cap (enclosed).
Mutual Interference Filter (E39-E6/-E8)
A set of 4 filters are sold together for two through-beam mod­els (for 2 each of emitters and receivers).
For mounting, refer to the figure of the slit for the E3S-A Pho­toelectric Sensor.
The arrow printed on the cover indicates the direction of polar­ization. By attaching the filters opposite to each other in polar­ization to the emitters and the receivers (refer to the figure) in rows, mutual interference can be prevented (in any case, the filter attached to an emitter and to the corresponding receiver must be the same in direction of polarization or the photoelec­tric sensor will not function).
Mounting Bracket
The direction of the optical axis coincides with the mounting direction of the E3S when the mounting screw is inserted into the lock hole of the mounting bracket. Unlike conventional photoelectric sensors, if the sensing object (or the retroreflec­tor in the case of a through-beam sensor) is in the mounting direction of the photoelectric sensor, the object is detected with the incident light without the time-consuming adjustment of the optical axis (but if the mounting surface is not flat, the adjustment of the optical axis may still be required).
Note: The maximum tightening torque applied to the screw is 5.5 kgf x cm
(0.53 N x m).
Installation of Accessories
Sensitivity Adjustor Knob (Attachment)
To temporarily use the knob to adjust the sensitivity of the photoelectric sensor, insert side A into the shaft of the sensi­tivity adjustor.
To permanently use the knob to adjust the sensitivity of the photoelectric sensor, insert side B into the shaft (the knob cannot be removed if once side B is inserted into the shaft).
Slit (E39-S46 Order Separately) for E3S-A
Use the rubber attachment with the metal cover if a slit width of 2 mm is required. Insert the 0.5- or 1-mm slit between the metal cover and rubber attachment if a slit width of 0.5 or 1 mm is desired. These slits fit into the rubber attachment.
Note: Apply the slit to the lens of the photoelectric sensor marked with an arrow
indicating the position of the optical axis (apply it to the bottom lens of hor­izontal sensors and the top lens of vertical sensors).
Optical Axis Reflector (E39-R5 Order Separately)
Use this attachment when the set distance is long and adjust­ment is mechanically difficult with a sensing object.
Attach the reflector to the receiver (refer to the figure). Look at the reflector from right behind the emitter. The reflec-
tor should be bright with red light when the optical beam strikes the reflector. If the emitter has a turbo function, the re­flector looks brighter with the function switched on.
When the reflector is removed, the light beam strikes the re­ceiver.
Unused lens
Lens actually in use (attach the slit to this lens)
Arrow indicating optical axis position
Emitter
Receiver
Be aware of the direction of polarization.
Optical axis lock hole (M3)
Optical axis
Base of mounting bracket
Bracket can move in this direction
Mounting direction
(A)
(B)
Metal cover
Slit (0.5 mm or 1 mm)
Rubber attachment
Indented portions
E3S-A
2 mm
Arrow indicating position of optical axis
Receiver
Emitter
Eye
E39-R5
Optical axis confirmation reflector
Page 34
A-264 Standard Photoelectric Sensors
In the interest of product improvement, specifications are subject to change without notice.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.