Omron E3F2-3Z1, E3F2-R2Z1, E3F2-R2Z2, E3F2-DS10Z1, E3F2-DS10Z2 Datasheet

...
1E3F2-240VAC
Cylindrical photoelectric sensor with built-in power supply in M18 housing
E3F2-240VAC
• Easy installation by compact M18 housing
• Built-in power supply, suitable for 24-240 VAC; no extra power supply needed
• Through-beam, Retro-reflective and diffuse-reflective types
Ordering information
Note: Standard cable length is 2 m. Models provided with a 5 m long cable are available. When ordering, specify the cable length by adapting the length of the cable
(e.g. E3F2-R2Z1-E 5M). For other cable length please contact your OMRON sales representative.
Accessories (Order Separately)
For detailed information about Accessories, refer to the main chapter “Accessories” at the end of the document.
Sensing method Sensing
distance
Connection method Order code
Light-ON Dark-ON
Through-beam 3 m
––2 m–
E3F2-3Z1 2M E3F2-3Z2 2M
Retro-reflective without M.S.R
*1
*1.
Order reflector seperately
0.1 to 2 m
*2
*2.
Measured with E39-R1
––2 m–
E3F2-R2Z1-E 2M E3F2-R2Z2-E 2M
Diffuse-reflective wide beam 0.1 m (fixed)
––2 m–
E3F2-DS10Z1-N 2M E3F2-DS10Z2-N 2M
Name Sensing distance (typical) Remark Model Reflectors 0.1 - 2 m 60 x 40 mm E39-R1
0.1 - 3 m 84 mm E39-R7
0.1 - 4 m 100 x 100 mm E39-R8
Mounting Bracket screw mount Y92E-B18
2 Standard Photoelectric Sensors
Specifications
Ratings / Characteristics
Item E3F2-3Z1
E3F2-3Z2
E3F2-R2Z1 E3F2-R2Z2
E3F2-DS10Z1
E3F2-DS10Z2 Type Through-beam Retro-reflective without M.S.R. Diffuse-reflective (wide-beam) Power supply voltage 24 to 240 VAC ±10 %, 50 / 60 Hz Current consumption 10 mA max. 5 mA max. Sensing distance
*1
*1.
For sensing distance in detail, please refer to ”Engineering Data”
3 m 0.1 to 2 m
(with E39-R1)
0.1 m
(5 x 5 cm white mat paper) Detectable object Opaque object: 11 mm min. Opaque object: 56 mm min. Opaque objects Directional angle 3° to 20° – Differential travel 20 % max. Response time 30 ms max. Control output AC solid state (SCR) 200 mA max.; residual voltage: 5 V max. at 200 mA Power reset time 100 ms Ambient illumination Incandescent lamp: 3000 lx max. Sunlight: 10000 lx max. Ambient temperature Operating: -25 to 55 °C / Storage: -30 to 70 °C (with no icing or condensation) Ambient humidity Operating: 35% to 85% / Storage: 35% to 95% (with no condensation) Insulation resistance 20 MΩ min. at 500 V DC between energized parts and case Dielectric strength 1500 VAC, 50 / 60 Hz for 1 min between energized parts and case Vibration resistance 10 to 55 Hz, 1.5 mm double amplitude for 2 hrs each direction (X, Y, Z) Shock resistance 500 m/sqr (approx. 50 g) for each direction (X, Y, Z) Degree of protection IEC 60529: IP66 Light source (wave length) Infrared LED (880 nm) Indicators Light incident/power indicator for light source (red) Sensitivity adjustment Fixed Connection method 2 m, 5 m pre-wired cable (PVC dia. 4 mm (14 / 0.15)
*2
)
*2.
For other cable materials (e.g. PUR) please contact your OMRON sales representative.
Operation mode Light-ON or Dark-ON (fixed) Circuit protection None Weight (approx.) 110 g (pre-wired 2 m cable) Housing materials Plastic (case: ABS; lens: PMMA)
3E3F2-240VAC
Engineering Data (Typical)
Operating Range (typical)
Excess Gain Ratio vs. Distance (typical)
Through-beam Models E3F2-3Z#
Retro-reflective Models E3F2-R2Z# (non polarizing) and reflectors
Diffuse-reflective Models E3F2-DS10Z-# (wide-beam type)
Through-beam Models E3F2-3Z#
Retro-reflective Models E3F2-R2Z# (non polarizing) and reflectors
Diffuse-reflective Models E3F2-DS10Z-# (wide-beam type)
123450
0
100
200
300
–100
–200
–300
Distance Y (mm)
Distance X (m)
typical sensing distance: 3.8 m
X
Y
1234560
0
100
200
300
–100
–200
–300
Distance Y (mm)
Distance X (m)
87
typical sensing distances:
E39-R1: 3.4 m E39-R7: 3.9 m E39-R8: 5.2 m
X
Y
Reflector
20 40 60 80 100 1200
0
10
20
30
–10
–20
–30
Distance Y (mm)
Distance X (mm)
140
white paper
(50 x 50 mm)
X
Y
Object
1 2345 60
100
10
1
0.1
Excess gain
Distance X (m)
7 1 2345 60
100
10
1
0.1
Excess gain
Distance X (m)
7
reflector E39-R1
reflector E39-R7
reflector E39-R8
50 100 1500
100
10
1
0.1
Excess gain
Distance X (mm)
200
Grey paper (18% reflectivity)
Sensing object:
50 x 50 mm
White paper (90% reflectivity)