Omron E2FQ DATASHEET

Page 1
Chemical Resistant Inductive Proximity Sensor
Shielded
2mm
5mm
10mm
Side length of sensing object d (mm)
Sensing distance X (mm)
0 5 10 15 20 25
2.4
2.2
2
1.8
1.6
1.4
1.2
1
0.8
0.6
0.4
0.2
Aluminum
Stainless steel (SUS304)
Mild steel
Brass
#d
t
=1
mm
X
Side length of sensing object d (mm)
Sensing distance X (mm)
0 5 10 15 20 25 30 35 40 50
7
6
5
4
3
2
1
Aluminum
Stainless steel (SUS304)
Mild steel
Brass
#d
t
=1
mm
X
Side length of sensing object d (mm)
Sensing distance X (mm)
0 102030405060
12
11
10
9
8
7
6
5
4
3
2
1
Aluminum
Stainless steel (SUS304)
Mild steel
Brass
#d
t
=1
mm
X
E2FQ
Fluoro plastic housing for highest chemical and detergent resistance
Ordering Information
DC 3-wire models DC 2-wire models
Shape Sensing distance
M12
PNP (NO) NPN (NO)
E2FQ-X2F1 E2FQ-X2E1 1.5 kHZ E2FQ-X2D1 800 Hz
Response frequency
NO
Response frequency
M18
M30
E2FQ-X5F1 E2FQ-X5E1 600 Hz E2FQ-X5D1 500 Hz
E2FQ-X10F1 E2FQ-X10E1 400 Hz E2FQ-X10D1 300 Hz
Characteristic data (typical)
E2FQ-X2# E2FQ-X5# E2FQ-X10#
.
1E2FQ
Page 2
Rating/Performance
Item Model E2FQ-X2@ E2FQ-X5@ E2FQ-X10@
Sensing distance 2 mm ±10% 5 mm ±10% 10 mm ±10%
Setting distance 0 to 1.6 mm 0 to 4 mm 0 to 8 mm
Differential distance E1, F1 models: 10% max. of sensing distance
Sensing object Ferrous metal (Sensitivity lowers with non-ferrous metals)
Standard sensing object (mild steel)
Response frequency*1
Power supply (Operating voltage range)
Current consumption E1, F1 models: 17 mA max.
Leakage current D1 models: 0.8 mA max.
Switching Control output
capacity
Residual
voltage
Indicator lamp E,D models: detection indicator (red)
Operating status (with sensing object approaching)
Protective circuits E1, F1 models: Protection for reverse polarity, load short circuit, surge voltage
Ambient temperature Operating/Storage: -25°C to 70°C (with no icing or condensation)
Ambient humidity Operating/Storage: 35% to 95%RH (with no condensation)
Temperature influence 10% max. of sensing distance at 23°C within temperature range of -25°C to 70°C
Voltage influence E1, F1 models: ±2.5% max. of sensing distance within rated voltage range ±15%
Insulation resistance 50 MW min. (at 500 VDC) between energized parts and case
Dielectric strength E1, F1, D1 models: 1,000 VAC 50/60 Hz for 1 min between energized parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
Protective structure IEC60529 IP67
Connection method Pre-wired models (standard length: 2 m)
Weight (Packed state) Approx. 70 g Approx. 130 g Approx. 170 g
Case Material
Sensing
surface
Accessories Instruction manual
*1. The response frequencies are average values measured on condition that the distance between each sensing object is twice as large as the size of the sensing
object and the sensing distance set is half of the maximum sensing distance.
12 x 12 x 1 mm 18 x 18 x 1 mm 30 x 30 x 1 mm
E1, F1 models: 1.5 kHz D1 models: 800 Hz
E1, F1 models: 600 Hz, D1 models: 500 Hz
E1, F1 models: 400 Hz, D1 models: 300 Hz
E1, F1 models: 12 to 24 VDC, ripple (p-p) : 10% max., (10 to 30 VDC) D1 models: 12 to 24 VDC, ripple (p-p) : 20% max., (10 to 36 VDC)
E1, F1 models: 200 mA max., D1 models: 5 to 100 mA DC
E1, F1 models: 2 V max. (load current: 200 mA with cable length: 2 m) D1 models: 4.0 V max. (under load current of 100 mA with cable length of 2 m)
Normally open (NO)
2
Destruction: 500 m/s each in X, Y, and Z directions
for 10 times
Destruction: 1,000 m/s
2
for 10 times each in X, Y, and Z directions
Fluoro plastic
2 Inductive Sensors
Page 3
Output Circuit Diagram
Yes
No
Operates
Releases
H
L
Load (between black and blue leads)
Output voltage (between black and blue leads)
Sensing object
ON
OFF
Operation indicator
Yes
No
Operates
Releases
H
L
Load (between black and blue leads)
Output voltage (between black and blue leads)
Sensing object
ON
OFF
Operation indicator
Brown
Black
Output
Blue
100W
4.7kW
2.2W
Main circuit
+V
0V
(see note 2)
(see note 1)
Tr
Note:
1. 200 mA max.(load current)
2. When a transistor is connected
Load
Operation indicator
Operates
Releases
ON
OFF
Load
Sensing object
Yes
No
Load
Brown
Blue
Main circuit
+V
0V
Note: The load can be connected to either the +V or the 0-V line.
l
m
n
l
m
D
d dia.
A
B
Mutual Interference (Unit: mm)
Model
Item
A B
E2FQ-X2#
30 20
E2FQ-X5#
50 35
E2FQ-X10#
100 70
Operating
status
NO
Output
specifications
PNP
NPN
DC 2-wire
Model Timing chart Output circuit
E2FQ-X@F1
Main circuit
4.7kW
2.2W
100W
E2FQ-X@E1
E2FQ-X@D1
Brown
Black
Output
Blue
+V
Load
0V
Precautions
Design
Effects of Surrounding Metal
Provide a minimum distance between the Sensor and the
surrounding metal as shown in the table below.
Effects of Surrounding Metal (Unit: mm)
Model
E2FQ-X2#
E2FQ-X5#
E2FQ-X10#
Mutual Interference
If more than one Proximity Sensor is installed face to face or
in parallel, ensure that the distances between two Units adja-
cent to each other are the same as or larger than the corre-
sponding values shown in the following table.
Item
Correct Use
l d D m n
12
0
18 20 27
0
818
30 40 45
Installation
Do not tighten the nut with excessive force. A washer must be
used with the nut.
Note: The table below shows the value of tightening torques when using
toothed washers.
Torque Tensile strength
Model
(torque)
E2FQ-X2# 0.98 Nm
E2FQ-X5#
E2FQ-X10#
2 Nm
Others
Chemical resistance
3E2FQ
Page 4
Dimensions (Unit: mm)
21 dia.
17
38
27
24
6
M12 x 1
Two, Toothed washers
Two, clamping nut
Indicator
(see note)
Note: Oil-resistant, vibration-resistant, and fire-retardant vinyl-insulated round cord, 6 dia. x 3 cores, standard length: 2 m The cord can be extended in an independent conduit for 200 m maximum.
E2FQ-X2E1 E2FQ-X2F1
21 dia.
17
38
27
24
6
M12 x 1
Two, Toothed washers
Two, clamping nut
Indicator
(see note)
Note: Oil-resistant, vibration-resistant, and fire-retardant vinyl-insulated round cord, 6 dia. x 2 cores, standard length: 2 m The cord can be extended in an independent conduit for 200 m maximum.
E2FQ-X2D1
29 dia.
40
47
32
2924
8
M18 x 1
Two, Toothed washers
Two, clamping nut
Indicator
(see note)
Note: Oil-resistant, vibration-resistant, and fire-retardant vinyl-insulated round cord, 6 dia. x 3 cores, standard length: 2 m The cord can be extended in an independent conduit for 200 m maximum.
E2FQ-X5E1 E2FQ-X5F1
29 dia.
40
47
32
2924
8
M18 x 1
Two, Toothed washers
Two, clamping nut
Indicator
(see note)
Note: Oil-resistant, vibration-resistant, and fire-retardant vinyl-insulated round cord, 6 dia. x 2 cores, standard length: 2 m The cord can be extended in an independent conduit for 200 m maximum.
E2FQ-X5D1
42 dia.
36
57
50
41
38
8
M30 x 1.5
Two, Toothed washers
Two, clamping nut
Indicator
(see note)
Note: Oil-resistant, vibration-resistant, and fire-retardant vinyl-insulated round cord, 6 dia. x 3 cores, standard length: 2 m The cord can be extended in an independent conduit for 200 m maximum.
E2FQ-X10E1 E2FQ-X10F1
42 dia.
36
57
50
41
38
8
M30 x 1.5
Two, Toothed washers
Two, clamping nut
Indicator
(see note)
Note: Oil-resistant, vibration-resistant, and fire-retardant vinyl-insulated round cord, 6 dia. x 2 cores, standard length: 2 m The cord can be extended in an independent conduit for 200 m maximum.
E2FQ-X10D1
F
Model F (mm)
E2FQ-X2#
12.5 mm dia.
E2FQ-X5#
18.5 mm dia.
E2FQ-X10#
30.5 mm dia.
+0.50+0.50+0.5
0
Mounting Holes
4 Inductive Sensors
Page 5
WARRANTY
OMRON’s exclusive warranty is that the products are free from de­fects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EX­PRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MER­CHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WAR­RANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDI­RECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall responsibility of OMRON for any act exceed the in­dividual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRAN­TY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON’S ANALYSIS CONFIRMS THAT THE PROD­UCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
SUITABILITY FOR USE
THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR EN­SURING SAFETY OF PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES. Please refer to separate catalogs for OM­RON's safety rated products.
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the
customer’s application or use of the product.
At the customer’s request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combina­tion with the end product, machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document.
• Nuclear energy control systems, combustion systems, railroad sys­tems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate in­dustry or government regulations.
• Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PERFORMANCE DATA
Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual perfor­mance is subject to the OMRON Warranty and Limitations of Liability.
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be as­signed to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for man­ufacturing purposes, even when tolerances are shown.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user’s programming of a pro­grammable product, or any consequence thereof.
In the interest of product improvement, specifications are subject to change without notice.Cat. No. D029-E2-05-X
OMRON EUROPE B.V.
Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands Phone: +31 23 568 13 00 Fax: +31 23 568 13 88 www.industrial.omron.eu
5E2FQ
Loading...