Omron E2FM DATASHEET

Page 1
Inductive Proximity Sensor in full metal housing
E2FM
• Full body stainless steel housing for highest mechanical protection
• Low frequency modulation for metal chip immunity
Application
E2FM
Full body stainless steel housing with 0.8 mm thick sensing face protection
0.8 mm
Brush Test
Continuous Impact Test
The stainless-steel head shows minimal wear when cleaned with a metal brush.
More than 20 times the durability of standard sensors.
E2FM Standard sensor
Standard sensor E2FM
The standard sensor with top wall thickness of 0.2 mm was pene­trated after 10,000 impacts.
The E2FM was not penetrated after 250,000 impacts (depth:
0.26 mm).
A-1E2FM
Page 2
Features
Chemical and Oil Resistance (examples)
Tested resistance against:
• Sodium chloride
• Gasoline
• Dilute sodium hydroxide
• Dilute hydrochloric acid
• Mineral oil
• Barium hydroxide
Flush mounting installation possible
Minimum
installation
distance
Not influenced by surrounding
Workpiece
conventional products
Workpiece
E2FM
installation environment.
Note: When mounted in steel.
Low frequency modulation...
...for metal chip immunity reducing false signals caused by spatter accumulation and small metal objects.

Ordering Information

Sensors
DC 2-Wire, Pre-wired Connector Models
Appearance Sensing distance Output configuration Operation mode Model
Polarity: Yes,
Pin allocations: 1-4
Polarity: Yes,
Pin allocations: 1-4
No polarity: No,
Pin allocations: 3-4
Polarity: Yes,
Pin allocations: 1-4
No polarity: No,
Pin allocations: 3-4
Polarity: Yes,
Pin allocations: 1-4
No polarity: No,
Pin allocations: 3-4
DC 3-Wire, PNP NO
NO
E2FM-X1R5D1-M1GJ
E2FM-X2D1-M1GJ
E2FM-X2D1-M1GJ-T
E2FM-X5D1-M1GJ
E2FM-X5D1-M1GJ-T
E2FM-X10D1-M1GJ
E2FM-X10D1-M1GJ-T
E2FM-X1R5B1-M1
Shielded
M8
M12
M18
M30
1.5 mm
2 mm
5 mm
10 mm
DC 3-Wire, M12 Connector Models
Appearance Sensing distance Output configuration Operation mode Model
Shielded
M8
M12 E2FM-X2B1-M1
M18 E2FM-X5B1-M1
1.5 mm
2 mm
5 mm
M30 E2FM-X10B1-M1
10 mm
A-2 Inductive Proximity Sensor
Page 3

Rating and Specifications

DC 2-Wire (E2FM-X@D@)
Size M8 M12 M18 M30 M12 M18 M30
Shielded Shielded
E2FM-X1R5D1
Item
Model
-M1GJ
Sensing distance 1.5 mm±10% 2 mm±10% 5 mm±10% 10 mm±10% 2 mm±10% 5 mm±10% 10 mm±10%
Set distance 0 to 1.05 mm 0 to 1.4 mm 0 to 3.5 mm 0 to 7 mm 0 to 1.4 mm 0 to 3.5 mm 0 to 7 mm
Differential travel 15% max. of sensing distance
Sensing object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 5.)
Standard sensing object
Iron, 8 × 8 × 1 mm
Response frequency * 200 Hz 100 Hz 100 Hz 50 Hz 100 Hz 100 Hz 50 Hz
Power supply voltage (operating voltage
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
range)
Leakage current 0.8 mA max.
Output configuration With polarity Without polarity
Control output
Switching capacity
Residual voltage
3 to 100 mA
3 V max. (Load current: 100 mA, Cable length: 2 m)
Indicators Operation indicator (red LED), Setting/Operation indicator (green LED)
Operation mode (with sensing object
NO
approaching)
Protection circuits Surge suppressor, Load short-circuit protection
Ambient temperature range
Ambient humidity range
Temperature influence
Operating/Storage: -25 to 70° C (with no icing or condensation)
Operating/Storage: 35% to 95% (with no condensation)
±20% max. of sensing distance at 23° C in the temperature range of -25 to 70° C.
Voltage influence ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between current carry parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
Destruction: 500 m/s 10 times each
2
in X, Y, and Z directions
Degree of protection IEC 60529 IP67, DIN 40050 part 9: IP69k
Connection method Pig-tail Connector Models (Standard cable length: 0.3 m)
Weight (packed state) Approx. 65 g Approx. 85 g Approx. 110 g Approx. 190 g Approx. 85 g Approx. 110 g Approx. 190 g
Case Stainless steel (SUS303)
Materi­als
Sensing surface
(thickness) (0.4 mm) (0.8 mm) (0.8 mm)
Clamping nuts
Stainless steel (SUS303)
Stainless steel (SUS303)
Cable PVC (flame retardant)
Toothed washer
Zinc-plated iron
Accessories Instruction manual
* The response frequency of the DC switching section is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the
standard sensing object, and a set distance of half the sensing distance.
E2FM-X2D1
-M1GJ
Iron, 12 × 12 × 1 mm
E2FM-X5D1
-M1GJ
Iron, 30 × 30 × 1 mm
Destruction: 1,000 m/s
E2FM-X10D1
-M1GJ
Iron, 54 × 54 × 1 mm
E2FM-X2D1
-M1GJ-T
Iron, 12 × 12 × 1 mm
5 V max. (Load current: 100 mA, Cable length: 2 m)
2
10 times each in X, Y, and Z directions
E2FM-X5D1
-M1GJ-T
Iron, 30 × 30 × 1 mm
E2FM-X10D1
-M1GJ-T
Iron, 54 × 54 × 1 mm
E2FM
A-3E2FM
Page 4
DC 3-Wire (E2FM-X@B@)
Size M8 M12 M18 M30
Shielded Shielded
Item Model E2FM-X1R5B1-M1 E2FM-X2B1-M1 E2FM-X5B1-M1 E2FM-X10B1-M1
Sensing distance 1.5 mm±10% 2 mm±10% 5 mm±10% 10 mm±10%
Set distance 0 to 1.05 mm 0 to 1.4 mm 0 to 3.5 mm 0 to 7 mm
Differential travel 15% max. of sensing distance
Sensing object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 5.)
Standard sensing object
Response frequency * 200 Hz 100 Hz 100 Hz 50 Hz
Power supply voltage (operating voltage range)
Current consumption 10 mA max.
Output configuration PNP open collector output
Switching
Control output
capacity
Residual voltage
Indicators Operation indicator (yellow LED)
Operation mode (with sensing object approaching)
Protection circuits
Ambient temperature range
Ambient humidity range
Temperature influence
Voltage influence
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between current carry parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
Degree of protection IEC 60529 IP67, DIN 40050 part 9: IP69k
Connection method Connector Models
Weight (packed state) Approx. 45 g Approx. 55 g Approx. 75 g Approx. 160 g
Case Stainless steel (SUS303)
Sensing surface
Materi­als
(thickness) (0.4mm) (0.8mm)
Clamping nuts
Toothed washer
Accessories Instruction manual
* The response frequency of the DC switching section is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the
standard sensing object, and a set distance of half the sensing distance.
Iron, 8 × 8 × 1 mm Iron, 12 × 12 × 1 mm Iron, 30 × 30 × 1 mm Iron, 54 × 54 × 1 mm
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
200 mA max.
2 V max. (Load current: 200 mA, Cable length: 2 m)
NO
Reversed power supply polarity protection, Surge suppressor, Load short-circuit protection, and Reversed out­put polarity protection (except the E2FM-X1R5B1-M1)
Operating/Storage: -25 to 70° C (with no icing or condensation)
Operating/Storage: 35% to 95% (with no condensation)
±20% max. of sensing distance at 23° C in the temperature range of -25 to 70° C.
±1% max. of sensing distance in the rated voltage ±15% range (using the sensing distance at the rated voltage as standard)
Destruction: 500 m/s 10 times each in X, Y, and
2
Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
Z directions
Stainless steel (SUS303)
Stainless steel (SUS303)
Zinc-plated iron
A-4 Inductive Proximity Sensor
Page 5

Engineering Data (Typical)

Sensing Area Influence of Sensing Object Size and Material
E2FM-X@ E2FM-X1R5@ E2FM-X2@
12
10
Distance X (mm)
8
6
4
E2FM-X1R5@
2
0
-25 -15-20 -10 -5 0 5 10 15 20 25
E2FM-X10@
E2FM-X5@
E2FM-X2D@
Distance Y (mm)
2.5
2.0
Distance X (mm)
1.5
1.0
0.5
0.0 0 5 10 15 20 25
Side length of sensing object: d (mm)
Iron
Stainless steel (SUS304) Brass
Aluminum Copper
3.0
2.5
Distance X (mm)
2.0
1.5
1.0
0.5
0.0 01015202530355
Iron
Stainless steel (SUS304)
Aluminum
Brass
Copper
Side length of sensing object: d (mm)
E2FM
E2FM-X5@ E2FM-X10@ E2FM-X@D1-M1GJ(-T)
Leakage Current
7
6
5
Distance X (mm)
4
3
2
1
0
020406080
Side length of sensing object: d (mm)
Iron
Stainless steel (SUS304)
Brass
Aluminum Copper
12
10
Distance X (mm)
8
6
4
2
0
0 102030405060 809070
Side length of sensing object: d (mm)
Iron
Stainless steel (SUS304)
Brass
Aluminum
Copper
1.0
E2FM-X1R5D1-M1GJ
0.8
Leakage current (mA)
0.6
E2FM-X5D1-M1GJ(-T)
0.4
0.2
0.0 0 5 10 15 20 25 30
E2FM-X2D1-M1GJ(-T)
Residual Output Voltage
E2FM-X@B1-M1 E2FM-X@D1-M1GJ(-T)
2
1.5
1
Residual output voltage (V)
E2FM-X2B1-M1
E2FM-X5B1-M1
0.5 E2FM-X10B1-M1
5
4
3
Residual output voltage (V)
2
1
E2FM-X@D1-M1GJ-T
E2FM-X@D1-M1GJ
E2FM-X10D1-M1GJ(-T)
Power supply voltage (V)
0
1 10 50 100 200 1,000
E2FM-X1R5B1-M1
Load current (mA)
0
1 3 5 1 0 3 0 5 0 100
Load current (mA)
A-5E2FM
Page 6

I/O Circuit Diagrams

DC 2-Wire Models
Operation
mode
Model Timing chart Output circuit
E2FM­X@D1-
M1GJ
NO
E2FM­X@D1-
M1GJ-T
DC 3-Wire Models
Opera-
mode
tion
NO
Output
configu-
ration
PNP
open-
collector
model
Model Timing chart Output circuit
E2FM-
X1R5B1-
E2FM-
X2B1-M1
E2FM-
X5B1-M1
E2FM-
X10B1-M1
Non-sensing area
Sensing object
(%) 70 (TYP)
M1
Non-sensing area
Sensing object
(%)
Set position
Unstable sensing
Stable sensing
area
100 0
Rated sensing distance
100 0
Rated sensing distance
area
Sensing area
Proximity sensor
Setting
ON
indicator
OFF
(green)
Operation
ON
indicator (red)
OFF
ON
Control output
OFF
Proximity sensor
ON
OFF
ON
OFF
1
Proximity
sensor
main circuit
4
Note: The load can be connected to either the +V or 0 V side.
4
Proximity
sensor
main
circuit
3
0 V (12 to 24 VDC)
Note 1. The load can be connected to either the +V or 0 V side.
2. The E2FM-X@@1-M1GJ-T has no polarity. There is no need to be concerned about the polarity of pins 3 and 4.
1
Proximity
sensor
main
circuit
4
3
Note: There is no reversed output polarity protection diode.
Operation indicator (yellow)
Control output
Proximity
sensor
main
circuit
1
4
3
Load
12 to 24 VDC
0 V
Load
12 to 24 VDC
12 to 24 VDC
Load
12 to 24 VDC
Load
Connector Pin
Arrangement
Note: Pins 2 and 3 are not used.
Connector Pin
Arrangement
Note: Pins 1 and 2 are not used.
Connector Pin
Arrangement
Note: Pin 2 is not used.
0 V
Connector Pin
Arrangement
Note: Pin 2 is not used.
0 V
A-6 Inductive Proximity Sensor
Page 7
Safety Precautions
(Uni
)
WARNING
This product is not designed or rated for ensuring
safety of persons. Do not use it for such purposes.
Never use this product with an AC power supply.
Otherwise, explosion may result.
Precautions for Safe Use
The following precautions must be observed to ensure safe
operation.
1. Do not use the Sensor in an environment where inflammable or explosive gas is present.
2. Do not attempt to disassemble, repair, or modify any Sensors.
3. Power Supply Voltage Do not use a voltage that exceeds the rated operating voltage range. Applying a voltage that is higher than the operating voltage range may result in explosion or fire.
4. Incorrect Wiring Be sure that the power supply polarity and other wiring is correct. Incorrect wiring may cause explosion or fire.
5. Connection without a Load If the power supply is connected directly without a load, the internal elements may explode or burn. Be sure to insert a load when connecting the power supply.
Precautions for Correct Use
Do not use the Sensor under ambient conditions that exceed
the ratings to ensure maximum lifetime:
1. Please do not use the Sensor in the following locations.
(1) Outdoor locations directly subject to sunlight, rain, snow, or
water droplets
(2) Locations subject to atmospheres with chemical vapors, in
particular solvents and acids
(3) Locations subject to corrosive gas
2. The Sensor may malfunction if used near ultrasonic cleaning equipment, high-frequency equipment, transceivers, cellular phones, inverters, or other devices that generate a high-frequency electric field. Refer to the Sensor General Catalog for typical measures.
3. Laying the Sensor wiring in the same conduit or duct as high­voltage wires or power lines may result in incorrect operation and damage due to induction. Wire the Sensor using a separate conduit or independent conduit.
4. Cleaning Never use thinner or other solvents. Otherwise, the Sensor surface may be dissolved.
Design
Influence of Surrounding Metal
When the Proximity Sensor is embedded in metal, make sure
that the clearances given in the following table are main-
tained. The values depend on the type of nuts used for mount-
ing. Be sure to use the supplied nuts (SUS303).
d dia.
D
l
n
m
l
(Unit: mm)
Item
Model
E2FM-X1R5@
E2FM-X2@
E2FM-X5@
E2FM-X10@
Note: The influence from other non-magnetic surrounding metals is nearly the
same as that from aluminum.
Embedding
material
Iron 0 8 0 4.5 30
Aluminum 10 50 10 4.5 50
Iron 0120 840
Aluminum 16 70 16 8 70
Iron 0 18 0 20 60
Aluminum 16 80 16 20 80
Iron 0 30 0 40 100
Aluminum 24 120 24 40 120
l d D m n
Mutual Interference
When installing two or more Sensors face-to-face or side-by-
side, ensure that the minimum distances given in the following
table are maintained.
t: mm
Model Item A B
E2FM-X1R5@ 35 30
A
E2FM-X2@ 40 35
E2FM-X5@ 65 60
B
E2FM-X10@ 110 100
Chips from Cutting Aluminum or Cast Iron
Normally, chips from cutting aluminum or cast iron will not
cause a detection signal to be output even if it adheres to or
accumulates on the detection surface. In the following cases,
however, a detection signal may be output. Remove the cut-
ting chips in these cases.
1. If d D at the center of the
2 3
detection surface where d is the cutting chip size and D is the detection surface size
Model
Dimension
(mm)
D
d
D
Cutting chip
Detection surface
E2FM-X1R5@ 6
E2FM-X2@ 10
E2FM-X5@ 16
E2FM-X10@ 28
Pressed down
Cutting chips
Mounting
Do not tighten the nut with excessive force. A washer must be
used with the nut. Do not use tightening force that exceeds the
values in the following table.
Model Torque
E2FM-X1R5@ 9 N·m E2FM-X2@ 30 N·m E2FM-X5@ 70 N·m E2FM-X10@ 180 N·m
E2FM
A-7E2FM
Page 8

Dimensions (Unit: mm)

Sensors
E2FM-X1R5D1-M1GJ
30
15 dia.
13
E2FM-X5D1-M1GJ E2FM-X5D1-M1GJ-T
29 dia.
24
25
45
M8 × 1
*1. 4-dia. vinyl-insulated round cable (flame retardant), Standard length; 300 mm *2. Operation indicator (red/green)
Setting indicator (green)
4
M18 × 1
Toothed washer
*1. 6-dia. vinyl-insulated round cable (flame retardant), Standard length; 300 mm *2. Operation indicator (red/green)
Setting indicator (green)
49
Two clamping nuts
Toothed washer
56
42
36
10
Two clamping nuts
Indicator *2
Indicator *2
Pig-tail Connector Models
E2FM-X2D1-M1GJ E2FM-X2D1-M1GJ-T
53
39
33
Two clamping nuts
Toothed washer
7
Indicator *2
*1
M12 × 1
*1
21 dia.
17
4
M12 × 1
*1. 6-dia. vinyl-insulated round cable (flame retardant), Standard length; 300 mm *2. Operation indicator (red/green)
Setting indicator (green)
M12 × 1
E2FM-X10D1-M1GJ E2FM-X10D1-M1GJ-T
63.5
49
43
Two clamping nuts
Toothed washer
10
M12 × 1
Indicator *2
*1
42 dia.
M12 × 1
*1
36
5
M30 × 1.5
*1. 6-dia. vinyl-insulated round cable (flame retardant), Standard length; 300 mm *2. Operation indicator (red/green)
Setting indicator (green)
M12 Connector Models
E2FM-X1R5B1-M1
15 dia.
13
4
M8 × 1
Toothed washer
E2FM-X5B1-M1
29 dia.
24
M18 × 1
Mounting Hole Dimensions
34.5
30
25
Two clamping nuts
36
4
Toothed washer
53.5
5
M12 × 1
Four operation indicators (yellow)
56
42
10
Two clamping nuts
Four operation indicators (yellow)
M12 × 1
E2FM-X2B1-M1
21 dia.
17
E2FM-X10B1-M1
42 dia.
36
M12 × 1
M30 × 1.5
39
33
4
Two clamping nuts
Toothed washer
43
5
Two clamping nuts
Toothed washer
53
7
M12 × 1
Four operation indicators (yellow)
63.5
49
10
M12 × 1
Four operation indicators (yellow)
Dimension M8 M12 M18 M30
F (mm) 8.5 dia. 12.5 dia. 18.5 dia. 30.5 dia.
+0.5 0
+0.5 0
+0.5 0
+0.5 0
F
A-8 Inductive Proximity Sensor
Page 9
READ AND UNDERSTAND THIS DOCUMENT
Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or comments.
WARRANTY
OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON’S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
SUITABILITY FOR USE
THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES. Please refer to separate catalogs for OMRON's safety rated products.
PERFORMANCE DATA
Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability.
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof.
COPYRIGHT AND COPY PERMISSION
This document shall not be copied for sales or promotions without permission.
This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this document in any manner, for any other purpose. If copying or transmitting this document to another, please copy or transmit it in its entirety.
E2FM
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer’s application or use of the product.
At the customer’s request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
• Outdoor use, uses involving potential chemical contamination or
electrical interference, or conditions or uses not described in this document.
• Nuclear energy control systems, combustion systems, railroad
systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations.
• Systems, machines, and equipment that could present a risk to life
or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
A-9E2FM
Page 10
In the interest of product improvement, specifications are subject to change without notice.Cat. No. D104-E2-01-X
OMRON EUROPE B.V.
Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands Phone: +31 23 568 13 00 Fax: +31 23 568 13 88 www.eu.omron.com
A-10 Inductive Proximity Sensor
Loading...