Omron Y92E-B30, Y92E-B8, Y92E-B18, E2E-X1R5F1, E2E-X2E1 Data Sheet

...
Standard Proximity Sensor
E2E
Your Search for Proximity Sensors Starts with the World-leading Performance and Quality of the E2E
• Standard Sensors for detecting ferrous metals.
• Models with different frequencies are also available to prevent mutual interference.
• Superior environment resistance with standard cable made of oil­resistant PVC and sensing surface made of material that resists cutting oil.
• Useful to help prevent disconnection. Cable protector provided as a standard feature.
Be sure to read Safety Precautions on page 27.
CSM_E2E_DS_E_8_1
*1, *2
*1: No AC/DC 2-wire models or AC 2-wire M8 models are compliant. *2: Attach three ferrite clamps to the cable of the E2E-X3@@ and
E2E-X8MD@. (Refer to information on TDK catalog number ZCAT2035-0930A.)
Features
2-Wire Models
Pre-wired Models with Oil-resistant Reinforced PUR Cables Added
to the Lineup and Easy Differentiation with Orange Head
Oil ResistanceOil Resistance
Oil Resistance
Differentiation from standard models: Orange Head
Lineup includes models with Smartclick pre-wired connectors for fast connection.
Insert all the way.
Oil Resistance (Insulation service life): twice or three times that of oil-resistant vinyl chloride
Click
1/8 turn
Cable FlexibilityCable FlexibilityCable Flexibility
Cable Flexibility: approximately twice that of cinyl chloride cables
XS5 Smartclick connectors used to enable checking connector mating
Jacket: Polyester elastomer
Insulation: Oil-resistant grade PUR (polyurethane)
Cable Flexibility at Cable Flexibility at
Cable Flexibility at Low Temperatures Low Temperatures
Low Temperatures
More Flexibility at 40°C
1
E2E
Lineup includes models with self-diagnostic output to provide notification of failures and unstable detection conditions, such as coil burnout.
Contributes to preventive maintenance to keep the line from stopping.
Reduced wiring, fewer resources, and low power consumption contribute to environmentalism.
Wiring work and amount of copper wire used reduced to two thirds of that required for 3-wire models.
Current consumption drastically reduced to less than 10% (when a DC 2-wire model is compared with a DC 3-wire model).
3-Wire Models
Lineup includes models with small diameter (3 dia., 4 dia., 5.4 dia., M5)
All small-diameter models use sealed construction. Operation is stable even when the Sensor is mounted in a small space or embedded in metal.
Bright indicators enable easily checking the installation condition.
Wide range of ambient operating temperatures: 40°C to 85°C (M8 to M30 models)
Wide range of ambient operating temperatures also for small-diameter models: 25°C to 70°C
Suitable for low-temperature and high-temperature applications, which are troublesome for photoelectric sensors.
Lineup includes models with flexible cable (4-dia. to M30 models)
Reduced risk of disconnection in applications with moving parts.
2
Models Listed by E2E Type
: Standard Models, : Different frequency, @: Self-diagnosis, : Different frequency and self-diagnosis,
---: Not listed
2-Wire Models
E2E
Power
DC
AC
AC/DC
supply
Shielding
Shield-
ed
Un-
shield-
ed
Shield-
ed
Un-
shield-
ed
Shield-
ed
Size and sensing distance
M8
2 m
M12
3 mm
M18
7 mm
M30
10 mm
M8
4 mm
M12
8 mm
M18
14 mm
M30
20 mm
M8
1.5 mm
M12
2 mm
M18
5 mm
M30
10 mm
M8
2 mm
M12
5 mm
M18
10 mm
M30
18 mm
M12
2 mm
M18
5 mm
M30
10 mm
Oil-resistant
reinforced PUR cable
Polarity
Yes
Yes
No
Yes
No
Yes
No
mode
Operation
smartclick
M12 pre-wired
connector models
with 2-m
Pre-wired model
cable
NO ●●● ● ●●●--- ●●
NC --- --- --- NO ●●●●@■● ● ●@ ---
NC --- --- ---
NO --- --- --- --- --- --- --- --- ---
NC --- --- --- --- --- --- --- --- --- --­NO ●●●●@■● ● ●@ ---
NC --- --- ---
NO --- --- --- --- --- --- --- --- ---
NC --- --- --- --- --- --- --- --- --­NO ●●●●@■● ● ●@ ---
NC --- --- --- ---
NO --- --- --- --- --- --- --- --- ---
NC --- --- --- --- --- --- --- --- ---
(cable material: oil-resistant PVC)/Connector models
smartclick
M12 pre-wired
connector models
Standard cable and flexible cable
with standard
Pre-wired model
2-m cable
with flexible
Pre-wired model
2-m cable
with standard
Pre-wired model
pin arrangement)
M12 standard
pre-wired
connector models
5-m cable
M12 connector (IEC
NO --- --- --- ●●●●--- ●●
NC --- --- --- --- --- --- NO --- --- ●●@■● ● ●@ ---
NC --- --- --- --- --- --- ---
Yes
NO --- --- ●●@■● ● ●@ ---
NC --- --- --- --- --- --- NO --- --- ●●@■● ● ●@ ---
NC --- --- --- --- --- --- ---
NO --- --- --- --- --- --- --- --- ---
NC --- --- --- --- --- --- --- --- ---
NO --- --- --- ●▲ --- ●●--- --- ---
NC --- --- --- --- --- --- --- ---
NO --- --- --- ●▲ --- ●●--- --- ---
NC --- --- --- --- --- --- --- ---
NO --- --- --- ●▲ --- ●●--- --- ---
NC --- --- --- --- --- --- --- ---
--­NO --- --- --- --- --- --- --- --- ---
NC --- --- --- --- --- --- --- --- ---
NO --- --- --- ●▲ --- ●●--- --- ---
NC --- --- --- --- --- --- --- ---
NO --- --- --- ●▲ --- --- --- --- ---
NC --- --- --- --- --- --- --- ---
NO --- --- --- ●▲ --- --- --- --- ---
NC --- --- --- --- --- --- --- ---
NO --- --- --- --- --- --- --- --- ---
NC --- --- --- --- --- --- --- --- --- ---
NO --- --- --- --- --- --- --- ---
--­NC --- --- --- --- --- --- --- --- --- ---
NO --- --- --- --- --- --- --- --- ---
NC --- --- --- --- --- --- --- --- --- ---
Page
Ordering
Refer to page 7.
Refer to
Models
with Self­diagnostic Output on
page 8.
Refer to
Models with con­ventional
connector
pin assign-
ments on
page 9.
Refer to page 8.
Refer to
Models with Self-
diagnostic
Output or
Models with con­ventional
connector
pin assign-
ments on
page 9.
Information
M8 connector
pin arrangement)
M12 connector (old
Dimensions refer-
Refer
to page
ence chart
29.
Refer
to page
10.
3
: Standard Models, : Different frequency, ---: Not listed
3-Wire Models
E2E
Power
DC
NPN
DC
PNP
supply
Shielding
Shield-
ed
Un-
shield-
ed
Shield-
ed
Un-
shield-
ed
Size and sensing distance
3 dia.
0.6 mm
4 dia.
0.8 mm
M5
1 mm
5.4 dia. 1 mm
M8
1.5mm
M12
2 mm
M18
5 mm
M30
10 mm
M8
2 mm
M12
5 mm
M18
10 mm
M30
18 mm
3 dia.
0.6 mm
4 dia.
0.8 mm
M5
1 mm
5.4 dia. 1 mm
M8
1.5mm
M12
2 mm
M18
5 mm
M30
10 mm
M8
2 mm
M12
5 mm
M18
10 mm
M30
18 mm
Oil-resistant
reinforced PUR cable
Polarity
Yes
Yes
mode
Operation
smartclick
M12 pre-wired
NO --- --- --- --- --- --- --- ---
NC --- --- --- --- --- --- --- ---
NO --- --- --- ●●●--- --- ---
NC --- --- --- --- --- --- --- ---
NO --- --- --- ●●●--- --- ---
NC --- --- --- --- --- --- --- ---
NO --- --- --- ●●●--- --- ---
NC --- --- --- --- --- --- --- ---
NO --- --- --- ●●●●---
NC --- --- --- --- --- ---
NO --- --- --- ●▲ --- ---
NC --- --- --- --- --- --- ---
NO --- --- --- ●▲ --- ---
NC --- --- --- --- --- --- ---
NO --- --- --- ●▲ --- ---
NC --- --- --- --- --- --- ---
NO --- --- --- ●●--- ---
NC --- --- --- --- --- ---
NO --- --- --- ●▲ --- ---
NC --- --- --- --- --- --- ---
NO --- --- --- ●▲ --- ---
NC --- --- --- --- --- --- ---
NO --- --- --- ●▲ --- ---
NC --- --- --- --- --- --- ---
NO --- --- --- --- --- --- --- ---
NC --- --- --- --- --- --- --- ---
NO --- --- --- ●●--- --- --- ---
NC --- --- --- --- --- --- --- ---
NO --- --- --- ●●--- --- --- ---
NC --- --- --- --- --- --- --- ---
NO --- --- --- --- --- --- --- ---
NC --- --- --- --- --- --- --- ---
NO --- --- --- ●●●●---
NC --- --- --- --- --- ---
NO --- --- --- ●▲ --- ---
NC --- --- --- --- --- --- ---
NO --- --- --- ●▲ --- ---
NC --- --- --- --- --- --- ---
NO --- --- --- ●●--- --- ---
NC --- --- --- --- --- --- ---
NO --- --- --- ●●--- ---
NC --- --- --- --- --- ---
NO --- --- --- ●●--- --- ---
NC --- --- --- --- --- --- ---
NO --- --- --- ●●--- --- ---
NC --- --- --- --- --- --- ---
NO --- --- --- ●●--- --- ---
NC --- --- --- --- --- --- ---
connector models
Pre-wired model
(cable material: oil-resistant PVC)/Connector models
smartclick
M12 pre-wired
with 2-m cable
Standard cable and flexible cable
connector models
Pre-wired model
2-m cable
with standard
Pre-wired model
2-m cable
with flexible
with standard
Pre-wired model
5-m cable
M12 connector (IEC
pin arrangement)
M12 standard pre-
wired
connector models
Page
Ordering
Refer
to page
11.
Refer
to page
12.
Refer
to page
11.
Refer
to page
12.
Information
M8 connector
Dimensions refer-
Refer
to page
29.
ence chart
4
E2E Guide to Selection by Purpose
E2E
Environment
Maintenance
Wide operating
temperature range
Resists the influence of surrounding metal
Reducing stocked
models
Easy replacement
NPN/PNP output
AC/DC
40 to 85°C AC 2-wire: M12 to M30, DC 3-wire: M8 to M30
25 to 70° Models not listed above.
Shielded Models
DC 2-Wire Models E2E-X@D@
AC/DC 2-Wire Models E2E-X@T1
Smartclick Pre-wired Connector Models E2E-X@D@-M1TGJ-(U)
Pre-wired Connector Models E2E-X@D1-M1(G)J-(T)
Connector Models E2E-X@D@-M1(G) E2E-X@E@-M1 E2E-X@Y@-M1
C
Reducing troubles
Note: Refer to Models Not Listed in this Catalog for Long Body Models, Transmission Couplers, and Power Couplers.
Higher oil resistance
Mounting to moving
parts
Robotics cable
Mutual interference
prevention
Miswiring measures
Early discovery
of problems
Reinforced
Standard
Load short-circuit
protection
No polarity
Models with Oil-resistor reinforced PUR cable E2E-X@D@-U
Models with Oil-resistant PVC cable
Robotics Cable Models E2E-X@D1-R E2E-X@E1-R
Models with a Different Frequency (NO Models only) E2E-X@@15
DC 2-Wire Models E2E-X@D@ DC 3-Wire Models E2E-X@E@
DC 2-Wire No-polarity Models E2E-X@D1-M1J-T
Diagnostic Models E2E-X@D1S
5
E2E Model Number Legend
E2E
E2E-
No. Classification Code Meaning Remarks
A Appearance
B Sensing distance
C Shielding
D
E
F Oscillation frequency type
G Self-diagnosis
H Connection method
I Connector specifications
J DC 2-wire polarity
K Cable specifications
L New model N
M Cable length Letter M
Note: The purpose of this model number legend is to provide understanding of the meaning of specifications from the model number.
A BCDEFG H I - J - K - L- M
C Cylindrical (not threaded) X Cylindrical (threaded)
Number Sensing distance (Unit: mm) Example:
R Indication of decimal point
Blank Shielded Models
M Unshielded Models B DC 3-wire PNP open-collector output C DC 3-wire NPN open-collector output
Power supply and output specifications
Form of output switching el­ement
Models are not available for all combinations of code numbers. Ask your OMRON representative if you require a customized model.
D DC 2-wire polarity/no polarity E DC 3-wire NPN collector load built-in output F DC 3-wire PNP collector load built-in output T AC/DC 2-wire Y AC 2-wire 1 Normally open (NO) 2 Normally closed (NC)
Blank Standard frequency
5 Different frequency
Blank No
5Yes
Blank Pre-wired
M1 M12-size metal connector
M3 M8-size metal connector
Blank
G
J
GJ
TJ
TGJ
Blank Polarity
T No polarity
Blank Standard PVC cable (oil resistant)
R Flexible PVC cable (oil resistant) U Polyurethane cable (oil resistant and reinforced)
Connector Models DC 3-wire and AC 2-wire, DC 2-wire with self-diagnosis output, DC 2-wire with old pin arrangement (polarity)
Connector Models DC 2-wire with IEC pin arrangement (polarity)
Pre-wired Connector Models DC 3-wire and AC 2-wire, DC 2-wire with IEC pin arrangement (polarity), DC 3-wire and AC 2-wire, DC 2-wire with self-diagno­sis output, DC 2-wire with old pin arrangement (polarity)
Pre-wired Connector Models DC 2-wire with IEC pin arrangement (polarity)
Pre-wired Smartclick Connector Models DC 2-wire with IEC pin arrangement (no polarity)
Pre-wired Smartclick Connector Models DC 2-wire with IEC pin arrangement (polarity)
New model (Applies only to DC 2-wire pre-wired and shielded models.)
Cable length (Unit: m) (Applicable to Pre-wired Models and Pre­wired Connector Models.)
R6: 0.6 mm 1R5: 1.5 mm
Whether D models have polarity is defined by num­ber J.
Used to prevent mutual in­terference.
This is blank if the cable specification in number K is R or U.
Example:
2M
0.3M
6
Ordering Information
2-Wire Models
Shielded DC 2-wire Models with No Self-diagnostic Output [Refer to Dimensions on page 29.]
E2E
Appear-
ance
M8
M12
M18
M30
*1. Models with different frequencies are also available. The model number is E2E-X @D15 (example: E2E-X3D15-N 2M). *2. Models with a flexible cable are also available. Add "-R" rather than "-N" to the end of the model number (example: E2E-X2D1-R 2M). *3. The standard stock includes models with a cable length of 5 m. Specify the cable length at the end of the model number. (Example: E2E-X3D1-N 5M) *4. Refer to page 24 for details. *5. The residual voltage for models without polarity is 5 V, so use caution concerning the connection load interface conditions (e.g., PLC ON voltage). Refer to page 28. *6. The standard cable length is 300 mm. Cables with a length of 500 mm and 1 m can also be manufactured.
Sensing distance
2 mm
3 mm
7 mm
10 mm
Connection
method
M12 Pre-wired Smart­click Connector Mod­els (0.3m)
Pre-wired Models (2 m)
M12 Connector Mod­els
M8 Connector Models ---
M12 Pre-wired Smart­click Connector Mod­els (0.3m)
Pre-wired Models (2 m)
M12 Connector Mod­els
M12 Standard Pre­wired Connector Mod­els (0.3 m) *6
M12 Pre-wired Smart­click Connector Mod­els (0.3m)
Pre-wired Models (2 m)
M12 Connector Mod­els
M12 Standard Pre­wired Connector Mod­els (0.3 m) *6
M12 Pre-wired Smart­click Connector Mod­els (0.3m)
Pre-wired Models (2 m)
M12 Connector Mod­els
M12 Standard Pre­wired Connector Mod­els (0.3 m) *6
Cable
specifications
PUR (increased oil-resistant)
PVC (oil-resistant) NO 1: +V, 4: 0 V G E2E-X2D1-M1TGJ 0.3M
PUR (increased oil-resistant)
PVC (oil-resistant)
PUR (increased oil-resistant)
PVC (oil-resistant) NO 1: +V, 4: 0 V G E2E-X3D1-M1TGJ 0.3M
PUR (increased oil-resistant)
PVC (oil-resistant)
PVC (oil-resistant)
PUR (increased oil-resistant)
PVC (oil-resistant) NO 1: +V, 4: 0 V G E2E-X7D1-M1TGJ 0.3M
PUR (increased oil-resistant)
PVC (oil-resistant)
PVC (oil-resistant)
PUR (increased oil-resistant)
PVC (oil-resistant) NO 1: +V, 4: 0 V G E2E-X10D1-M1TGJ 0.3M
PUR (increased oil-resistant)
PVC (oil-resistant)
PVC (oil-resistant)
---
---
---
---
Polar-
ity
Yes
Yes
Yes
No *5
Yes
Yes
No *5
Yes
Yes
No *5
Opera-
tion
mode
NO 1: +V, 4: 0 V
NC 1: +V, 2: 0 V E2E-X2D2-M1TGJ-U 0.3M
NO
NC E2E-X2D2-U 2M
NO E2E-X2D1-N 2M *2*3
NC E2E-X2D2-N 2M *3
NO 1: +V, 4: 0 V A E2E-X2D1-M1G
NC 1: +V, 2: 0 V D E2E-X2D2-M1G
NO 1: +V, 4: 0 V
NC 1: +V, 2: 0 V E2E-X2D2-M3G
NO 1: +V, 4: 0 V
NC 1: +V, 2: 0 V E2E-X3D2-M1TGJ-U 0.3M
NO
NC E2E-X3D2-U 2M
NO E2E-X3D1-N 2M *1*2*3
NC E2E-X3D2-N 2M *3
NO 1: +V, 4: 0 V A E2E-X3D1-M1G *1
NC 1: +V, 2: 0 V D E2E-X3D2-M1G
NO 1: +V, 4: 0 V A E2E-X3D1-M1GJ 0.3M
NC 1: +V, 2: 0 V D E2E-X3D2-M1GJ 0.3M
NO (3, 4): (+V, 0 V) C E2E-X3D1-M1J-T 0.3M
NC (1, 2): (+V, 0 V) D
NO 1: +V, 4: 0 V
NC 1: +V, 2: 0 V E2E-X7D2-M1TGJ-U 0.3M
NO
NC E2E-X7D2-U 2M
NO E2E-X7D1-N 2M *1*2*3
NC E2E-X7D2-N 2M *3
NO 1: +V, 4: 0 V A E2E-X7D1-M1G *1
NC 1: +V, 2: 0 V D E2E-X7D2-M1G
NO 1: +V, 4: 0 V A E2E-X7D1-M1GJ 0.3M
NC 1: +V, 2: 0 V D E2E-X7D2-M1GJ 0.3M
NO (3, 4): (+V, 0 V) C E2E-X7D1-M1J-T 0.3M
NC (1, 2): (+V, 0 V) D E2E-X7D2-M1J-T 0.3M
NO 1: +V, 4: 0 V
NC 1: +V, 2: 0 V E2E-X10D2-M1TGJ-U 0.3M
NO
NC E2E-X10D2-U 2M
NO E2E-X10D1-N 2M *1*2*3
NC E2E-X10D2-N 2M
NO 1: +V, 4: 0 V A E2E-X10D1-M1G *1
NC 1: +V, 2: 0 V D E2E-X10D2-M1G
NO 1: +V, 4: 0 V A E2E-X10D1-M1GJ 0.3M
NC 1: +V, 2: 0 V D E2E-X10D2-M1GJ 0.3M
NO (3, 4): (+V, 0 V) C E2E-X10D1-M1J-T 0.3M
NC (1, 2): (+V, 0 V) D E2E-X10D2-M1J-T 0.3M
Pin
arrangement
--- ---
--- ---
--- ---
--- ---
Applicable
connector
code *4
H
I
H
H
H
Model
E2E-X2D1-M1TGJ-U 0.3M
E2E-X2D1-U 2M
E2E-X2D1-M3G
E2E-X3D1-M1TGJ-U 0.3M
E2E-X3D1-U 2M
---
E2E-X7D1-M1TGJ-U 0.3M
E2E-X7D1-U 2M
E2E-X10D1-M1TGJ-U 0.3M
E2E-X10D1-U 2M
7
2-Wire Models
Unshielded DC 2-Wire Models with No Self-diagnosis Output [Refer to Dimensions on page 29.]
E2E
Appear-
ance
M8
M12
M18
M30
*1. Models with different frequencies are also available. The model number is E2E-X @D15 (example: E2E-X8MD15 2M). *2. Models with a flexible cable are also available. Add -R to the end of the model number. (example: E2E-X4MD1-R 2M). *3. The standard stock includes models with a cable length of 5 m. Specify the cable length at the end of the model number. (Example: E2E-X4MD1 5M) *4. Refer to page 24 for details.
Sensing distance
4 mm
8 mm
14 mm
20 mm
Connection
method
Pre-wired Models (2 m) PVC (oil-resistant)
M12 Connector Models ---
M8 Connector Models ---
12M Pre-wired Smart­click Connector Models (0.3m)
Pre-wired Models (2 m) PVC (oil-resistant)
M12 Connector Models ---
M12 Standard Pre­wired Connector Mod­els (0.3 m)
12M Pre-wired Smart­click Connector Models (0.3m)
Pre-wired Models (2 m) PVC (oil-resistant)
M12 Connector Models ---
M12 Standard Pre­wired Connector Mod­els (0.3 m)
12M Pre-wired Smart­click Connector Models (0.3m)
Pre-wired Models (2 m) PVC (oil-resistant)
M12 Connector Models ---
M12 Standard Pre­wired Connector Mod­els (0.3 m)
Cable
specifications
PVC (oil-resistant) NO 1: +V, 4: 0 V G E2E-X8MD1-M1TGJ 0.3M
PVC (oil-resistant)
PVC (oil-resistant) NO 1: +V, 4: 0 V G E2E-X14MD1-M1TGJ 0.3M
PVC (oil-resistant)
PVC (oil-resistant) NO 1: +V, 4: 0 V G E2E-X20MD1-M1TGJ 0.3M
PVC (oil-resistant)
Polar-
ity
Yes
Opera-
tion
mode
NO
NC E2E-X4MD2 2M
NO 1: +V, 4: 0 V A E2E-X4MD1 2M
NC 1: +V, 2: 0 V D E2E-X4MD2-M1G
NO 1: +V, 4: 0 V
NC 1: +V, 2: 0 V E2E-X4MD2-M3G
NO
NC E2E-X8MD2 2M
NO 1: +V, 4: 0 V A E2E-X8MD1-M1G *1
NC 1: +V, 2: 0 V D E2E-X8MD2-M1G
NO 1: +V, 4: 0 V A E2E-X8MD1-M1GJ 0.3M
NC 1: +V, 2: 0 V D
NO
NC E2E-X14MD2 2M
NO 1: +V, 4: 0 V A E2E-X14MD1-M1G *1
NC 1: +V, 2: 0 V D E2E-X14MD2-M1G
NO 1: +V, 4: 0 V A E2E-X14MD1-M1GJ 0.3M
NC 1: +V, 2: 0 V D E2E-X14MD2-M1GJ 0.3M
NO
NC E2E-X20MD2 2M
NO 1: +V, 4: 0 V A E2E-X20MD1-M1G *1
NC 1: +V, 2: 0 V D E2E-X20MD2-M1G
NO 1: +V, 4: 0 V A E2E-X20MD1-M1GJ 0.3M
NC 1: +V, 2: 0 V D
Pin
arrangement
--- ---
--- ---
--- ---
--- ---
Applicable
connector
code *4
I
Model
E2E-X4MD1 2M *2*3
E2E-X4MD1-M3G
E2E-X8MD1 2M *1*2*3
E2E-X14MD1 2M *1*2*3
E2E-X20MD1 2M *1*2*3
---
---
Shielded DC 2-Wire Models with Self-diagnosis Output [Refer to Dimensions on page 29.]
Appear-
ance
M12
M18
M30
*1. Models with different frequencies are also available. The model number is E2E-X @D15S (example: E2E-X3D15S 2M). *2. Refer to page 24 for details.
Sensing distance
3 mm
7 mm
10 mm
Connection
method
Pre-wired Models (2 m)
M12 Connector Models
Pre-wired Models (2 m)
M12 Connector Models
Pre-wired Models (2 m)
M12 Connector Models
Cable
specifications
PVC (oil-resistant)
---
PVC (oil-resistant) --- --- E2E-X7D1S 2M *1
---
PVC (oil-resistant) --- --- E2E-X10D1S 2M *1
---
Polar-
ity
Yes
Opera-
tion
mode
2: +V and diagnostic output 3: 0 V 4: +V and control output
NO
2: +V and diagnostic output 3: 0 V 4: +V and control output
2: +V and diagnostic output 3: 0 V 4: +V and control output
Pin
arrangement
--- --- E2E-X3D1S 2M *1
Applicable
connector
code *2
D E2E-X3D1S-M1
D E2E-X7D1S-M1
D E2E-X10D1S-M1
Model
8
2-Wire Models
Unshielded DC 2-Wire Models with Self-diagnosis Output [Refer to Dimensions on page 29.]
E2E
Appear-
ance
M12
M18
M30
*1. Models with different frequencies are also available. The model number is E2E-X @MD15S (example: E2E-X8MD15S 2M). *2. Refer to page 24 for details.
Sensing distance
8 mm
14 mm
20 mm
Connection
method
Pre-wired Mod­els (2 m)
M12 Connector Models
Pre-wired Mod­els (2 m)
M12 Connector Models
Pre-wired Mod­els (2 m)
M12 Connector Models
Cable
specifications
PVC (oil-resistant)
---
PVC (oil-resistant) --- --- E2E-X14MD1S 2M *
---
PVC (oil-resistant) --- --- E2E-X20MD1S 2M *
---
Polar-
ity
Yes
Opera-
tion
mode
2: +V and diagnostic output 3: 0 V 4: +V and control output
NO
2: +V and diagnostic output 3: 0 V 4: +V and control output
2: +V and diagnostic output 3: 0 V 4: +V and control output
Pin
arrangement
--- --- E2E-X8MD1S 2M *
Connector Pin Assignments of DC 2-Wire Models
The connector pin assignments of each New E2E DC 2-Wire Model conform to IEC 947-5-2 Table III. (Only DC 2-Wire Models have been changed in comparison to the previous models.)
The following models with conventional connector pin assignments are available as well. (Only NO Models can be used.) The cable at the right should also be used if the XW3A-P@45-G11 Connector Junction Box is already being used.
Cable length Model
500 mm XS2W-D421-BY1
Internal Wiring
(Proximity Sensor end) (Wired end)
1 4
Models with conventional connector pin assignments are available as well.
Appearance
NO Applicable connector code * NC Applicable connector code *
Model
M8 E2E-X2D1-M1 C E2E-X2D2-M1 D
Shielded
M12 E2E-X3D1-M1 C E2E-X3D2-M1 D
M18 E2E-X7D1-M1 C E2E-X7D2-M1 D
M30 E2E-X10D1-M1 C E2E-X10D2-M1 D
M8 E2E-X4MD1-M1 C E2E-X4MD2-M1 D
Unshielded
M12 E2E-X8MD1-M1 C E2E-X8MD2-M1 D
M18 E2E-X14MD1-M1 C E2E-X14MD2-M1 D
M30 E2E-X20MD1-M1 C E2E-X20MD2-M1 D
Note: Refer to page 24 for details.
Applicable
connector
code *2
D E2E-X8MD1S-M1
D E2E-X14MD1S-M1
D E2E-X20MD1S-M1
Model
4 3
9
2-Wire Models
AC 2-Wire Models Shielded Models [Refer to Dimensions on page 29.]
E2E
Appear-
ance
M8
M12
M18
M30
*1. Models with different frequencies are also available. The model number is E2E-X @Y@5 (example: E2E-X5Y15 2M). *2. The standard stock includes models with a cable length of 5 m. Specify the cable length at the end of the model number. (Example: E2E-X2Y1 5M) *3. Refer to page 24 for details.
Sensing distance
1.5 mm
2 mm
5 mm
10 mm
Connection
method
Pre-wired Models (2 m)
Pre-wired Models (2 m)
M12 Connector Models
Pre-wired Models (2 m)
M12 Connector Models
Pre-wired Models (2 m)
M12 Connector Models
Cable
specifications
PVC (oil-resistant)
PVC (oil-resistant)
---
PVC (oil-resistant)
---
PVC (oil-resistant)
---
Operation
mode
NO
NC E2E-X1R5Y2 2M
NO
NC E2E-X2Y2 2M
NO (3, 4): (AC, AC) E E2E-X2Y1-M1
NC (1, 2): (AC, AC) F E2E-X2Y2-M1
NO
NC E2E-X5Y2 2M
NO (3, 4): (AC, AC) E E2E-X5Y1-M1
NC (1, 2): (AC, AC) F E2E-X5Y2-M1
NO
NC E2E-X10Y2 2M
NO (3, 4): (AC, AC) E E2E-X10Y1-M1
NC (1, 2): (AC, AC) F E2E-X10Y2-M1
Pin
arrangement
--- ---
--- ---
--- ---
--- ---
Applicable con-
nector code *3
E2E-X1R5Y1 2M
E2E-X2Y1 2M *1*2
E2E-X5Y1 2M *1*2
E2E-X10Y1 2M *1*2
Model
Unshielded Models
Appear-
ance
M8
M12
M18
M30
*1. Models with different frequencies are also available. The model number is E2E-X @MY@5 (example: E2E-X5MY15 2M). *2. The standard stock includes models with a cable length of 5 m. Specify the cable length at the end of the model number. (Example: E2E-X5MY1 5M) *3. Refer to page 24 for details.
Sensing distance
2 mm
5 mm
10 mm
18 mm
Connection
method
Pre-wired Models (2 m)
Pre-wired Models (2 m)
M12 Connector Models
Pre-wired Models (2 m)
M12 Connector Models
Pre-wired Models (2 m)
M12 Connector Models
Cable
specifications
PVC (oil-resistant)
PVC (oil-resistant)
---
PVC (oil-resistant)
---
PVC (oil-resistant)
---
Operation
mode
NO
NC E2E-X2MY2 2M
NO
NC E2E-X5MY2 2M
NO (3, 4): (AC, AC) E E2E-X5MY1 2M
NC (1, 2): (AC, AC) F E2E-X5MY2-M1
NO
NC E2E-X10MY2 2M
NO (3, 4): (AC, AC) E E2E-X10MY1-M1
NC (1, 2): (AC, AC) F E2E-X10MY2-M1
NO
NC E2E-X18MY2 2M
NO (3, 4): (AC, AC) E E2E-X18MY1-M1
NC (1, 2): (AC, AC) F E2E-X18MY2-M1
Pin
arrangement
--- ---
--- ---
--- ---
--- ---
Applicable con-
nector code *3
E2E-X2MY1 2M
E2E-X5MY1 2M *1*2
E2E-X10MY1 2M *1
E2E-X18MY1 2M *1
Model
AC 2-Wire Models Shielded Models [Refer to Dimensions on page 29.]
(There are no unshielded models.)
Appear-
ance
M12
M18
M30
Note: Not compliant with CE. * The standard stock includes models with a cable length of 5 m. Specify the cable length at the end of the model number. (Example: E2E-X7T1 5M)
Sensing distance
3 mm
7 mm
10 mm
Connection
method
Pre-wired Models (2 m)
Pre-wired Models (2 m)
Pre-wired Models (2 m)
Cable
specifications
PVC (oil-resis­tant)
PVC (oil-resis­tant)
PVC (oil-resis­tant)
Operation
mode
NO
Pin
arrangement
--- --- E2E-X3T1 2M
--- --- E2E-X7T1 2M *
--- --- E2E-X10T1 2M
Applicable con-
nector code *3
Model
10
3-Wire Models
Shielded DC 3-Wire Models [Refer to Dimensions on page 29.]
E2E
Appear-
ance
3 dia.
4 dia.
M5
5.4 dia.
M8
M12
M18
M30
*1. The standard stock includes models with a cable length of 5 m. Specify the cable length at the end of the model number. (Example: E2E-X2E1 5M) *2. Models with a flexible cable are also available. Add -R to the end of the model number. (example: E2E-X5E1-R 2M). *3. Models with different frequencies are also available. The model number is E2E-X@@@5 (example: E2E-X5E15 2M). *4. Refer to page 24 for details.
Sensing distance
0.6 mm
0.8 mm
1 mm
1 mm
1.5 mm
2 mm
5 mm
10 mm
Connection
method
Pre-wired Models (2 m)
Pre-wired Models (2 m)
Pre-wired Models (2 m)
Pre-wired Models (2 m)
Pre-wired Models (2 m)
M12 Connector Models
M8 Connector Models
Pre-wired Models (2 m)
M12 Connector Models
Pre-wired Models (2 m)
M12 Connector Models
Pre-wired Models (2 m)
M12 Connector Models
Cable
specifica-
tions
PVC (oil-re­sistant)
PVC (oil-re­sistant)
PVC (oil-re­sistant)
PVC (oil-re­sistant)
PVC (oil-re­sistant)
PVC (oil-re­sistant)
PVC (oil-re­sistant)
PVC (oil-re­sistant)
PVC (oil-re­sistant)
Opera-
tion
mode
NO
NC E2E-CR6C2 2M E2E-CR6B2 2M
NO
NC E2E-CR8C2 2M E2E-CR8B2 2M
NO
NC E2E-X1C2 2M E2E-X1B2 2M
NO
NC E2E-C1C2 2M E2E-C1B2 2M
NO
NC E2E-X1R5E2 2M E2E-X1R5F2 2M
---
---
---
---
---
NO
NC
NO
NC
NO
NC E2E-X2E2 2M E2E-X2F2 2M
NO
NC
NO
NC E2E-X5E2 2M E2E-X5F2 2M
NO
NC
NO
NC E2E-X10E2 2M E2E-X10F2 2M
NO
NC
Pin
arrangement
--- ---
--- ---
--- ---
--- ---
--- ---
1: +V, 3: 0 V, 4: Control output
1: +V, 3: 0 V, 2: Control output
1: +V, 3: 0 V, 4: Control output
1: +V, 3: 0 V, 2: Control output
--- ---
1: +V, 3: 0 V, 4: Control output
1: +V, 3: 0 V, 2: Control output
--- ---
1: +V, 3: 0 V, 4: Control output
1: +V, 3: 0 V, 2: Control output
--- ---
1: +V, 3: 0 V, 4: Control output
1: +V, 3: 0 V, 2: Control output
Appli-
cable connec­tor code
*5
B
D E2E-X1R5E2-M1 E2E-X1R5F2-M1
I
B
D E2E-X2E2-M1 E2E-X2F2-M1
B
D E2E-X5E2-M1 E2E-X5F2-M1
B
D E2E-X10E2-M1 E2E-X10F2-M1
NPN output PNP output
E2E-CR6C1 2M E2E-CR6B1 2M
E2E-CR8C1 2M *1*2 E2E-CR8B1 2M *2
E2E-X1C1 2M *1*2 E2E-X1B1 2M *2
E2E-C1C1 2M *1*2 E2E-C1B1 2M
E2E-X1R5E1 2M *1*2 E2E-X1R5F1 2M *1*2
E2E-X1R5E1-M1 E2E-X1R5F1-M1
E2E-X1R5E1-M3 E2E-X1R5F1-M3
E2E-X1R5E2-M3 E2E-X1R5F2-M3
E2E-X2E1 2M *1*2*3 E2E-X2F1 2M *1*2*3
E2E-X2E1-M1 E2E-X2F1-M1
E2E-X5E1 2M *1*2*3 E2E-X5F1 2M *1*2*3
E2E-X5E1-M1 E2E-X5F1-M1
E2E-X10E1 2M *1*2*3 E2E-X10F1 2M *2
E2E-X10E1-M1 E2E-X10F1-M1
Model
11
3-Wire Models
Unshielded DC 3-Wire Models [Refer to Dimensions on page 29.]
E2E
Appear-
ance
M8
M12
M18
M30
*1. The standard stock includes models with a cable length of 5 m. Specify the cable length at the end of the model number. (Example: E2E-X5ME1 5M) *2. Models with a flexible cable are also available. Add -R to the end of the model number. (example: E2E-X5E1-R 2M). *3. Models with different frequencies are also available. The model number is E2E-X@M@@5 (example: E2E-X5ME15 2M). *4. Refer to page 24 for details.
Sensing distance
2 mm
5 mm
10 mm
18 mm
Connection
method
Pre-wired Models (2 m)
M12 Connector Models
M8 Connector Models
Pre-wired Models (2 m)
M12 Connector Models
Pre-wired Models (2 m)
M12 Connector Models
Pre-wired Models (2 m)
M12 Connector Models
Cable
specifications
PVC (oil-resis­tant)
---
---
PVC (oil-resis­tant)
---
PVC (oil-resis­tant)
---
PVC (oil-resis­tant)
---
Opera-
tion
mode
NO
NC E2E-X2ME2 2M E2E-X2MF2 2M
NO
NC
NO
NC
NO
NC E2E-X5ME2 2M E2E-X5MF2 2M
NO
NC
NO
NC E2E-X10ME2 2M E2E-X10MF2 2M
NO
NC
NO
NC E2E-X18ME2 2M E2E-X18MF2 2M
NO
NC
Pin
arrangement
--- ---
1: +V, 3: 0 V, 4: Control output
1: +V, 3: 0 V, 2: Control output
1: +V, 3: 0 V, 4: Control output
1: +V, 3: 0 V, 2: Control output
--- ---
1: +V, 3: 0 V, 4: Control output
1: +V, 3: 0 V, 2: Control output
--- ---
1: +V, 3: 0 V, 4: Control output
1: +V, 3: 0 V, 2: Control output
--- ---
1: +V, 3: 0 V, 4: Control output
1: +V, 3: 0 V, 2: Control output
Appli-
cable
connec-
tor code
*5
B
D E2E-X2ME2-M1 E2E-X2MF2-M1
I
B
D E2E-X5ME2-M1 E2E-X5MF2-M1
B
D E2E-X10ME2-M1 E2E-X10MF2-M1
B
D E2E-X18ME2-M1 E2E-X18MF2-M1
NPN output PNP output
E2E-X2ME1 2M *2 E2E-X2MF1 2M *2
E2E-X2ME1-M1 E2E-X2MF1-M1
E2E-X2ME1-M3 E2E-X2MF1-M3
E2E-X2ME2-M3 E2E-X2MF2-M3
E2E-X5ME1 2M
*1*2*3
E2E-X5ME1-M1 E2E-X5MF1-M1
E2E-X10ME1 2M
*1*2*3
E2E-X10ME1-M1 E2E-X10MF1-M1
E2E-X18ME1 2M
*1*2*3
E2E-X18ME1-M1 E2E-X18MF1-M1
Model
E2E-X5MF1 2M *2
E2E-X10MF1 2M *2
E2E-X18MF1 2M *2
12
E2E
Ratings and Specifications
E2E-X@D@ DC 2-Wire Models
Size M8 M12 M18 M30
Shielded Shielded Unshielded Shielded Unshielded Shielded Unshielded Shielded Unshielded
Item Model E2E-X2D@ E2E-X4MD@ E2E-X3D@ E2E-X8MD@ E2E-X7D@ E2E-X14MD@ E2E-X10D@ E2E-X20MD@
Sensing distance 2 mm ±10% 4 mm ±10% 3 mm ±10% 8 mm ±10% 7 mm ±10% 14 mm ±10% 10 mm ±10% 20 mm ±10%
Set distance *1 0 to 1.6 mm 0 to 3.2 mm 0 to 2.4 mm 0 to 6.4 mm 0 to 5.6 mm 0 to 11.2 mm 0 to 8 mm 0 to 16 mm
Differential travel 15% max. of sensing distance 10% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on pages 18 and 19.
Standard sensing object
Response frequency
*2
Power supply voltage (operating voltage range)
Leakage current 0.8 mA max.
Load
Control output
Indicators
Operation mode (with sensing object approaching)
Diagnostic output delay
Protection circuits Surge suppressor, Load short-circuit protection (for control and diagnostic output)
Ambient temperature range
Ambient humidity range
Temperature influence
Voltage influence ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1000 VAC, 50/60 Hz for 1 minute between current carry parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
Degree of protection
Connection method Pre-wired Models (Standard cable length: 2 m), Connector Models, or Pre-wired Connector Models (Standard cable length: 0.3 m)
Weight (pack­ed state)
Materi­als
Accessories Instruction manual
*1. Use the E2E within the range in which the setting indicator (green LED) is ON (except D2 Models). *2. The response frequency is an average value.
Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
*3. The residual voltage of each M1J-T Model is 5 V. When connecting to a device, make sure that the device can withstand the residual voltage. (Refer to page 28 for
details.)
current
Residual voltage
*3
Pre-wired Models
Pre-wired Connector Models
Connector Models
Case Stainless steel (SUS303) Nickel-plated brass
Sensing sur­face
Clamping nuts
Toothed washer
Iron, 8 × 8 × 1mm
1.5 kHz 1 kHz 0.8 kHz 0.5 kHz 0.4 kHz 0.1 kHz
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
3 to 100 mA, Diagnostic output: 50 mA for -D1(5)S Models
3 V max. (Load current: 100 mA, Cable length: 2 m, M1J-T Models only: 5 V max.)
D1 Models: Operation indicator (red) and setting indicator (green) D2 Models: Operation indicator (red)
D1 Models: NO D2 Models: NC
0.3 to 1 s
Operating: 25 to 70°C, Storage: 40 to 85°C (with no icing or condensation)
Operating/storage: 35% to 95% (with no condensation)
±15% max. of sensing distance at 23°C in the temperature range of 25 to 70°C
Destruction: 500 m/s 10 times each in X, Y, and Z directions
Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant Connector Models: IEC 60529 IP67
Approx. 60 g Approx. 70 g Approx. 130 g Approx. 175 g
Approx. 15 g Approx. 25 g Approx. 40 g Approx. 90 g
PBT
Nickel-plated brass
Zinc-plated iron
Iron, 20 × 20 × 1 mm
Refer to the timing charts under I/O Circuit Diagrams on page 21 for details.
2
--- Approx. 40 g Approx. 70 g Approx. 110 g
Iron, 12 × 12 × 1 mm
±10% max. of sensing distance at 23°C in the temperature range of 25 to 70°C
Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
Iron, 30 × 30 × 1 mm
Iron, 18 × 18 × 1 mm
Iron, 30 × 30 × 1 mm
Iron, 54 × 54 × 1 mm
13
E2E
E2E-X@Y@ AC 2-Wire Models
Size M8 M12 M18 M30
Shielded Shielded Unshielded Shielded Unshielded Shielded Unshielded Shielded Unshielded
Item Model E2E-X1R5Y@ E2E-X2MY@ E2E-X2Y@ E2E-X5MY@ E2E-X5Y@ E2E-X10MY@ E2E-X10Y@ E2E-X18MY@
Sensing distance 1.5 mm ±10% 2 mm ±10% 5 mm ±10% 10 mm ±10% 18 mm ±10%
Set distance 0 to 1.2 mm 0 to 1.6 mm 0 to 4 mm 0 to 8 mm 0 to 14 mm
Differential travel 10% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 19.)
Standard sensing object
Response frequency 25 Hz
Power supply voltage (operating voltage
*1
range)
Leakage current 1.7 mA max.
Load
Control output
Indicators Operation indicator (red)
Operation mode (with sensing object approaching)
Protection circuits Surge suppressor
Ambient temperature range *1*2
Ambient humidity range
Temperature influence
Voltage influence ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 4,000 VAC (M8 Models: 2,000 VAC), 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
Degree of protection
Connection method Pre-wired Models (Standard cable length: 2 m) and Connector Models
Weight
Materials
Accessories Instruction manual
*1. When supplying 24 VAC to any of the above models, make sure that the operating ambient temperature range is at least −25°C. *2. When using an M18 or M30 Connector Model at an ambient temperature between 70 and 85°C, make sure that the Sensor has a control output (load current) of
current
Residual voltage
Pre­wired Models Model
Connec­tor Models
Case Stainless steel (SUS303) Nickel-plated brass
Sensing surface
Clamp­ing nuts
Toothed washer
5 to 200 mA max.
Iron, 8 × 8 × 1mm
24 to 240 VAC (20 to 264 VAC), 50/60 Hz
5 to 100 mA 5 to 200 mA 5 to 300 mA
*2
Refer to Engineering Data on page 20.
Y1 Models: NO Y2 Models: NC
Operating/Storage: 25 to 70°C (with no icing or condensation)
Operating/storage: 35% to 95% (with no condensation)
±10% max. of sensing distance at 23°C in the temperature range of 25 to 70°C
Destruction: 500 m/s 10 times each in X, Y, and Z directions
Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant Connector Models: IEC 60529 IP67
Approx. 60 g Approx. 70 g Approx. 130 g Approx. 175 g
Approx. 15 g Approx. 25 g Approx. 40 g Approx. 90 g
PBT
Nickel-plated brass
Zinc-plated iron
Iron, 12 × 12 × 1 mm
Refer to the timing charts under I/O Circuit Diagrams on page 23 for details.
Operating/Storage: 40 to 85°C (with no icing or condensation)
±15% max. of sensing distance at 23°C in the temperature range of 40 to 85°C, ±10% max. of sensing distance at 23°C in the temperature range of 25 to 70°C
2
Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
Iron, 15 × 15 × 1 mm
Iron, 18 × 18 × 1 mm
Iron, 30 × 30 × 1 mm
Iron, 54 × 54 × 1 mm
14
E2E
E2E-X@T1 AC/DC 2-Wire Models
Size M12 M18 M30
Shielded Shielded
Item Model E2E-X3T1 E2E-X7T1 E2E-X10T1
Sensing distance 3 mm ±10% 7 mm ±10% 10 mm ±10%
Set distance 0 to 2.4 mm 0 to 5.6 mm 0 to 8 mm
Differential travel 10% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 18.)
Standard sensing object Iron, 12 × 12 × 1 mm Iron, 18 × 18 × 1 mm Iron, 30 × 30 × 1 mm
Response frequency *1
Power supply voltage (operating voltage range) *2
Leakage current
Control output
Indicators Operation indicator (red), Setting indicator (green)
Operation mode (with sensing object approaching)
Protection circuits Load short-circuit protection (20 to 40 VDC only), Surge suppressor
Ambient temperature range Operating: 25 to 70°C, Storage: 40 to 85°C (with no icing or condensation)
Ambient humidity range Operating/Storage: 35% to 95% (with no condensation)
Temperature influence ±10% max. of sensing distance at 23°C in the temperature range of 25 to 70°C
Voltage influence ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 4,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
Degree of protection IEC 60529 IP67, in-house standards: oil-resistant
Connection method Pre-wired Models (Standard cable length: 2 m)
Weight (packed state) Approx. 80 g Approx. 140 g Approx. 190 g
Materials
Accessories Instruction manual
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and
a set distance of half the sensing distance.
*2. Power Supply Voltage Waveform:
Use a sine wave for the power supply. Using a rectangular AC power supply may result in faulty reset.
DC 1 kHz 0.5 kHz 0.4 kHz
AC 25 Hz
24 to 240 VDC (20 to 264 VDC) 48 to 240 VAC (40 to 264 VAC)
DC: 1 mA max. AC: 2 mA max.
Load current
Residual voltage
Case Nickel-plated brass
Sensing surface
Clamping nuts
Toothed washer
5 to 100 mA
DC: 6 V max. (Load current: 100 mA, Cable length: 2 m) AC: 10 V max. (Load current: 5 mA, Cable length: 2 m)
NO (Refer to the timing charts under I/O Circuit Diagrams on page 21 for details.)
PBT
Nickel-plated brass
Zinc-plated iron
15
E2E
E2E-X@E@/F@ DC 3-Wire Models
Size M8 M12 M18 M30
Shielded Shielded Unshielded Shielded Unshielded Shielded Unshielded Shielded Unshielded
Item Model
Sensing distance 1.5 mm ±10% 2 mm ±10% 5 mm ±10% 10 mm ±10% 18 mm ±10%
Set distance 0 to 1.2 mm 0 to 1.6 mm 0 to 4 mm 0 to 8 mm 0 to 14 mm
Differential travel 10% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on pages 18 and 19.)
Standard sensing object
Response frequency
*1
Power supply voltage (operating voltage
*2
range)
Current consumption 13 mA max.
Load
Control output
Indicators Operation indicator (red)
Operation mode (with sensing object approaching)
Protection circuits Load short-circuit protection, Surge suppressor, Reverse polarity protection
Ambient temperature range *2
Ambient humidity range
Temperature influence
Voltage influence ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between current carry parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
Degree of protection
Connection method Pre-wired Models (Standard cable length: 2 m) and Connector Models
Weight
Materials
Accessories Instruction manual
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and
*2. When using an M8 Model at an ambient temperature between 70 and 85°C, supply 10 to 30 VDC to the Sensor and make sure that the Sensor has a control output
current *2
Residual voltage
Pre­wired Models
Connec­tor Models
Case Stainless steel (SUS303) Nickel-plated brass
Sensing surface
Clamp­ing nuts
Toothed washer
a set distance of half the sensing distance.
of 100 mA maximum.
E2E
-X1R5E@/F@
Iron, 8 × 8 × 1mm
2 kHz 0.8 kHz 1.5 kHz 0.4 kHz 0.6 kHz 0.2 kHz 0.4 kHz 0.1 kHz
12 to 24 VDC (10 to 40 VDC), ripple (p-p): 10% max.
200 mA max.
2 V max. (Load current: 200 mA, Cable length: 2 m)
E1/F1 Models: NO E2/F2 Models: NC Refer to the timing charts under I/O Circuit Diagrams on page 21 for details.
Operating/Storage: 40 to 85°C (with no icing or condensation)
Operating/Storage: 35% to 95% (with no condensation)
±15% max. of sensing distance at 23°C in the temperature range of 40 to 85°C ±10% max. of sensing distance at 23°C in the temperature range of 25 to 70°C
Destruction: 500 m/s 10 times each in X, Y, and Z directions
Pre-wired Models : IEC 60529 IP67, in-house standards: oil-resistant Connector Models : IEC 60529 IP67
Approx. 65 g Approx. 75 g Approx. 150 g Approx. 195 g
Approx. 15 g Approx. 25 g Approx. 40 g Approx. 90 g
PBT
Nickel-plated brass
Zinc-plated iron
E2E
-X2ME@/F@
Iron, 12 × 12 × 1 mm
2
E2E
-X2E@/F@
Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
E2E
-X5ME@/F@
Iron, 15 ×15 × 1mm
E2E
-X5E@/F@
Iron, 18 × 18 × 1 mm
E2E
-X10ME@/F@
Iron, 30 × 30 × 1 mm
E2E-X10E@/F@E2E
-X18ME@/F@
Iron, 54 × 54 × 1 mm
16
E2E
E2E-C@C/B@ and E2E-X1C/B@ DC 3-Wire Models
Size 3 dia. 4 dia. M5 5.4 dia.
Shielded Shielded
Item Model E2E-CR6C/B@ E2E-CR8C/B@ E2E-X1C/B@ E2E-C1C/B@
Sensing distance 0.6 mm ±15% 0.8 mm ± 15% 1 mm ±15%
Set distance 0 to 0.4 mm 0 to 0.5 mm 0 to 0.7 mm
Differential travel 15% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on pages 18 and 19.)
Standard sensing ob­ject
Response frequency * 2 kHz 3 kHz
Power supply voltage (operating voltage range)
Current consumption 10 mA max. 17 mA max.
Load
Control output
Indicators Operation indicator (red)
Operation mode (with sensing object approaching)
Protection circuits Reverse polarity protection, Surge suppressor
Ambient temperature range
Ambient humidity range
Temperature influ­ence
Voltage influence
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 500 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 500 m/s2 10 times each in X, Y, and Z directions
Degree of protection IEC 60529 IP66 IEC 60529 IP67, in-house standards: oil-resistant
Connection method Pre-wired Models (Standard cable length: 2 m)
Weight (packed state) Approx. 60 g
Materials
Accessories Instruction manual
* The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and
a set distance of half the sensing distance.
current
Residual voltage
Case Stainless steel (SUS303) Nickel-plated brass
Sensing surface
Clamping nuts
Toothed washer
Iron, 3 × 3 × 1 mm Iron, 5 × 5 × 1 mm
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Open-collector output, 80 mA max. (30 VDC max.)
1 V max. (Load current: 80 mA, Cable length: 2 m)
C1/B1 Models: NO C2 Models: NC
Operating/Storage: 25 to 70°C (with no icing or condensation)
Operating/Storage: 35% to 95% (with no condensation)
±15% max. of sensing distance at 23°C in the temperature range of −25 to 70°C
±5% max. of sensing distance at
rated voltage in the rated voltage ±10% range
Heat-resistant ABS
Nickel-plated brass (E2E-X1C/B@ only)
Zinc-plated iron (E2E-X1C/B@ only)
Refer to the timing charts under I/O Circuit Diagrams on page 22 for details.
Open-collector output, 100 mA max. (30 VDC max.)
2 V max. (Load current: 100 mA, Cable length: 2 m)
±2.5% max. of sensing distance at rated voltage in the rated voltage ±15% range
17
Engineering Data (Typical)
)
)
)
Sensing Area
Shielded Models E2E-C@C@/-X@C@ E2E-X@D@/-X@T1 E2E-X@E@/-X@Y@/-X@F@
12
10
Distance X (mm)
8
6
Y
4
2
0
20 15 10 5 0 5 10 15
X
E2E-X10
E2E-X7
E2E-X3
E2E-X2
Distance Y (mm)
12
10
Distance X (mm)
8
6
4
2
0
15 10 5 0 5 10
Y
X
E2E-X10
E2E-X5
E2E-X2
Distance Y (mm)
E2E
-X1R5
Unshielded Models E2E-X@MD@ E2E-X@ME@/-X@MY@/-X@MF@
30
25
30
25
Y
X
E2E-C@B1/-X@B@
1.6
1.4
1.2
Distance X (mm)
1.0
0.8
0.6
0.4
0.2
0
3.0 2.0 1.0 0 1.0 2.0
Y
X
E2E
E2E-X1/E2E-C1
E2E-CR8
E2E-CR6
Distance Y (mm)
Distance X (mm)
20
15
10
Y
X
5
0
30 20 10 0 10 20
E2E
-X20M
E2E
-X14M
E2E
-X8M
E2E
-X4M
Distance Y (mm)
Distance X (mm)
20
15
10
5
0
30 20 10 0 10 20
E2E-X18M
E2E-X10M
E2E-X5M
E2E-X2M
Distance Y (mm)
Influence of Sensing Object Size and Material
E2E-X2D@ E2E-X3D@/-X3T1 E2E-X7D@/-X7T1
3.0
d × d
t
= 1 mm
2.5
Distance X (mm)
2.0
1.5
1.0
0.5
0 5 10 15 20 25
X
Iron
Stainless steel (SUS304)
Brass
Aluminum Copper
Side length of sensing object: d (mm
4.0
d × d
t
3.5
3.0
Distance X (mm)
2.5
2.0
1.5
1.0
0.5
0 5 10 15 20 25 30 35 40
= 1 mm
X
Iron
Stainless steel (SUS304)
Brass
Aluminum
Copper
Side length of sensing object: d (mm)
8
d × d
t
7
6
Distance X (mm)
5
4
3
2
1
0 10 20 30 40 50
= 1 mm
X
Side length of sensing object: d (mm
E2E-X10D@/-X10T1 E2E-X4MD@ E2E-X8MD@
12
d × d
t
= 1 mm
X
10
Iron
6
d × d
t
= 1 mm
X
5
12
d × d
t
= 1 mm
10
X
Iron
Stainless steel (SUS304)
Brass
Aluminum
Copper
Distance X (mm)
8
6
4
2
0 10 20 30 40 50 60 70
Side length of sensing object: d (mm
Stainless steel (SUS304)
Brass Aluminum
Copper
Distance X (mm)
4
3
2
1
0 10 20 30 40 50 60 70
Side length of sensing object: d (mm)
Iron
Stainless steel (SUS304)
Brass Aluminum Copper
Distance X (mm)
8
6
4
2
0 10 15 20 30 40 50 60 70
Side length of sensing object: d (mm)
Iron
Stainless steel (SUS304)
Brass
Aluminum
Copper
18
E2E-X14MD@ E2E-X20MD@ E2E-X1R5E@/-X1R5Y@/-X1R5F@
)
25
d × d
20
X
Distance X (mm)
15
10
5
t
= 1 mm
Iron
Stainless steel (SUS304) Brass
Aluminum Copper
25
d × d
20
Distance X (mm)
15
10
5
X
t
= 1 mm
Iron
Stainless steel (SUS304)
Brass
Aluminum
Copper
2.5
d × d
2.0
Distance X (mm)
1.5
1.0
0.5
X
t
= 1 mm
Iron
Stainless steel (SUS304)
Brass
Aluminum
E2E
0 10 20 30 40 50 60 70
Side length of sensing object: d (mm)
0 10 20 30 40 50 60 70 80 90 100
Side length of sensing object: d (mm)
0 5 10 15 20 25
Side length of sensing object: d (mm)
E2E-X2E@/-X2Y@/-X2F@ E2E-X5E@/-X5Y@/-X5F@ E2E-X10E@/-X10Y@/-X10F@
2.5
d × d
t
= 1 mm
2.0
Distance X (mm)
1.5
1.0
0.5
X
Stainless steel (SUS304)
Aluminum
0 5 10 15 20 25
Side length of sensing object: d (mm)
Iron
Brass
7
d × d
t
X
= 1 mm
Stainless steel (SUS304)
Brass
Aluminum
Iron
6
5
Distance X (mm)
4
3
2
1
0 10 20 30 40 50
Side length of sensing object: d (mm
12
d × d
t
= 1 mm
10
Distance X (mm)
X
8
6
4
2
0 10 20 30 40 50 60
Stainless steel (SUS304)
Iron
Brass
Aluminum
Side length of sensing object: d (mm)
E2E-X2ME@/-X2MY@/-X2MF@ E2E-X5ME@/-X5MY@/-X5MF@ E2E-X10ME@/-X10MY@/-X10MF@
2.5
d × d
2.0
Distance X (mm)
1.5
1.0
0.5
X
t
= 1 mm
Iron
Stainless steel (SUS304)
Brass
Aluminum
Copper
7
d × d
6
X
5
Distance X (mm)
4
3
2
1
t
= 1 mm
Iron
Stainless steel (SUS304)
Brass
Aluminum
12
d × d
10
Distance X (mm)
X
8
6
4
2
t
= 1 mm
Iron
Stainless steel (SUS304)
Brass
Aluminum
0 5 10 15 20 25 30
Side length of sensing object: d (mm)
0 10 20 30 40 50
Side length of sensing object: d (mm)
0 10 20 30 40 50 60
E2E-X18ME@/-X18MY@/-X18MF@ E2E-CR6@ E2E-CR8@
25
d × d
t
= 1 mm
20
X
Distance X (mm)
15
10
5
0 20 40 60 80 100
Stainless steel (SUS304)
Brass
Aluminum
Side length of sensing object: d (mm)
Iron
0.7
d × d
Iron
Brass
Aluminum
X
0.6
0.5
Distance X (mm)
0.4
0.3
0.2
0.1
0 5 10 15 20
Stainless steel (SUS304)
Side length of sensing object: d (mm)
t
= 1 mm
1.2
d × d
1.0
Distance X (mm)
0.8
0.6
0.4
0.2
0 5 10 15 20 25 30
Side length of sensing object: d (mm)
t
= 1 mm
X
Iron
Stainless steel (SUS304)
Brass
Aluminum Copper
Side length of sensing object: d (mm)
19
E2E-X1@/-C1@
1.2
d × d
t
= 1 mm
1.0
X
E2E
Iron
0.8
Distance X (mm)
0.6
0.4
0.2
0 5 10 15 20 25
Side length of sensing object: d (mm)
Stainless steel (SUS304)
Aluminum
Brass
Leakage Current
E2E-X@D@ E2E-X@Y@ E2E-X@T1
1.0
0.8
0.6
Leakage current (mA)
0.4
0.2
0 5 10 15 20 25 30
E2E-X3D1-N
E2E-X2D1-N
E2E-X10D1-N
E2E-X7D1-N
Power supply voltage (V)
1.4
1.2
1.0
0.8
Leakage current (mA)
0.6
0.4
0.2
Proximity Sensor (OFF)
0 50 100 150 200 250 300
Protective resistance
mA
~
V
~
Power supply voltage (V)
AC power
1.4
1.2
1.0
Leakage current (mA)
0.8
0.6
0.4
0.2
0 50 100 150 200 250 300
Residual Output Voltage
E2E-X@D@ E2E-X@T1
5
6
200 VAC
AC power
DC power
Power supply voltage (V)
4
3
Residual output voltage (V)
2
1
0
1 3 5 10 30 50 100
E2E-X@D1-M1J-T
E2E-X@D@
Load current (mA)
5
4
Residual output voltage (V)
3
2
100 VAC
24 VDC
1 3 5 10 30 50 100
Load current (mA)
E2E-X@Y@ at 24 VAC E2E-X@Y@ at 100 VAC E2E-X@Y@ at 200 VAC
30
25
20
Load voltage VL (V)
15
10
5
Residual load voltage
0
1 3 5 10 30 50 100 300 500
Residual output voltage
V
~
V
A
~
L
Load current (mA)
ON
24 VAC
OFF
120
Residual output voltage
100
80
Load voltage VL (V)
60
40
20
Residual load voltage
0
1 3 5 10 30 50 100 300 500
A
~
V
~
V
L
Load current (mA)
100 VAC
OFF
ON
240
Residual output voltage
200
160
Load voltage VL (V)
120
80
40
Residual load voltage
0
1 3 5 10 30 50 100 300
V
~
V
A
~
L
Load current (mA)
200 VAC
OFF
ON
500
20
I/O Circuit Diagrams
E2E-X@D@ DC 2-Wire Models
Operation
mode
Without
self-
diagnostic
output:
NO
Model Timing Chart Output circuit
E2E-X@D1-N E2E-X@D1-M1G(J) E2E-X@D1-(M1TGJ)-U E2E-X@D1-M3G
E2E-X@D1-M1J-T
Non-sensing
area
Sensing object
(%)
Unstable sensing area
Rated sensing distance
Set position
Stable sensing area
80 0100
Proximity Sensor
ON
Setting indicator
OFF
(green)
ON
Operation
OFF
indicator (red)
ON
Control output
OFF
E2E
Polarity: Yes
1
Load
+V
Prox­imity Sensor main circuit
Note: The load can be connected to either the
+V or 0 V side.
Polarity: None
Prox­imity Sensor main circuit
Note 1. The load can be connected to either the +V or
0 V side.
2. The E2E-X@D1-M1J-T has no polarity.
Therefore, terminals 3 and 4 have no polarity.
Brown
4
Blue
4
3
Load
0 V
+V
(0 V)
0 V
(+V)
Without
self-
diagnostic
output:
NC
With self-
diagnostic
output:
NO
E2E-X@D2-N E2E-X@D2-M1G E2E-X@D2-(M1TGJ)-U E2E-X@D2-M3G
E2E-X@D1S E2E-X@D1S-M1
Non-sensing
area
Sensing object
(%)
Rated sensing distance
Non-sensing
area
Sensing object
(%)
Rated sensing distance
100
Unstable sensing area
Sensing area
Set position
Stable sensing area
800100
Proximity Sensor
0
ON
Operation
OFF
indicator (red)
ON
Control output
OFF
Proximity Sensor
ON
OFF
Setting indicator (green)
ON
OFF
Operation indicator (red)
ON
OFF
Control output
ON
Diagnostic output*
OFF
* The diagnostic output is ON when there is a coil
burnout or the sensing object is located in the unstable sensing area for 0.3 s or longer.
1
Load
+V Prox­imity Sensor main circuit
Brown
2
Blue
0 V
Note: The load can be connected to either the +V
or 0 V side.
Brown (4)
Load
+V
Prox­imity Sensor main circuit
Note: Connect both the loads to the +V side of
the control output and diagnostic output.
Orange (2) (diagnostic output)
Blue (3)
Load
+V
0
21
DC 3-Wire Models
Operation
mode
NO
NC
Output
specifica-
tions
NPN output
Model Timing Chart Output circuit
E2E-X@E@ E2E-X@E@-M1 E2E-X@E@-M3
Sensing object
Operation indicator (red)
Control output (between brown and black leads)
Output voltage (between black and blue leads)
Sensing object
Operation indicator (red)
Control output (between brown and black leads)
Output voltage (between black and blue leads)
Present
Not present
ON
OFF
ON
OFF
High
Low
Present
Not present
ON
OFF
ON
OFF
High
Low
Proximity
Sensor
main
circuit
*Constant current output is 1.5 to 3 mA. Note: For Connector Models, the
connection between pins 1, 4 and 3 uses an NO contact, and the connection between pins 1, 2 and 3 uses an NC contact.
100 Ω
Constant current*
Brown
Black
Blue
E2E
1
2
4
3
+V
Load
Tr
0 V
NO
NC
NO
NC
PNP output
NPN open-
collector
output
E2E-X@F@ E2E-X@F@-M1 E2E-X@F@-M3
E2E-C/X@C@
Sensing object
Operation indicator (red)
Control output (Between blue and black leads)
Output voltage (between brown and black leads)
Sensing object
Operation indicator (red)
Control output (Between blue and black leads)
Output voltage (between brown and black leads)
Sensing object
Operation indicator (red)
Control output
Sensing object
Operation indicator (red)
Control output
Present
Not present
OFF
OFF
High
Low
Present
Not present
OFF
OFF
High
Low
Present
Not present
ON
OFF
ON
OFF
Present
Not present
OFF
OFF
ON
ON
ON
ON
ON
ON
1
Brown
Proximity
Sensor
main
circuit
100 Ω
4
Black
3
Blue
Tr
*
2
Load
*When a transistor is connected Note: For Connector Models, the
connection between pins 1, 4 and 3 uses an NO contact, and the connection between pins 1, 2 and 3 uses an NC contact.
Brown
Load
Black
Blue
Proximity
Sensor
main circuit
100 Ω *
*The E2E-CR6@ does not have 100-Ω resistance.
+V
0 V
+V
0 V
NO
NC
PNP open-
collector
output
E2E-C/X@B@
Sensing object
Operation indicator (red)
Control output
Sensing object
Operation indicator (red)
Control output
Present
Not present
ON
OFF
ON
OFF
Present
Not present
ON
OFF
ON
OFF
Brown
Proximity
Sensor
main
circuit
100 Ω *
Black
Load
Blue
*The E2E-CR6@ does not have 100-Ω resistance.
+V
0 V
22
AC 2-Wire Models
Operation
mode
E2E
Model Timing Chart Output circuit
NO
E2E-X@Y@ E2E-X@Y@-M1
NC
AC/DC 2-Wire Models
Operation
mode
NO E2E-X@T1
Model Timing Chart Output circuit
Non-sensing
area
Sensing object
(%)
Sensing object
Operation indicator (red)
Control output
Sensing object
Operation indicator (red)
Control output
Unstable sensing area
Rated sensing distance
Present
Not present
ON
OFF
Operate
Reset
Present
Not present
ON
OFF
Operate
Reset
Set position
Stable sensing area
80100 0
Proximity Sensor
ON
Setting indicator (green)
OFF
ON
Operation indicator (red)
OFF
ON
Control output
OFF
Brown 3 (or 1)
Load
Proximity
Sensor
main
circuit
Blue 4 (or 2)
Note: For Connector Models, the connection
between pins 3 and 4 uses an NO contact, and the connection between pins 1 and 2 uses an NC contact.
Brown
Load
Proximity
Sensor
main
circuit
Blue
Power
supply
24 to 240 VDC
48 to 240 VAC
Note: The load can be connected to either the +V or
0 V side. There is no need to be concerned about the polarity (brown/blue) of the Proximity Sensor.
23
E2E
Sensor I/O Connectors
Model for Connectors and Pre-wired Connectors: A Connector is not provided with the Sensor. Be sure to order a Connector separately.
[Refer to Dimensions for the XS2, XS3, and XS5.]
Applicable
connector
code
A
B
C
D
E
F Straight XS2F-A421-D90-A XS2F-A421-G90-A E2E-X@Y2-M1 15
G
Screw Appearance *1
Straight XS2F-D421-DA0-A XS2F-D421-GA0-A L-shape XS2F-D422-DA0-A XS2F-D422-GA0-A
Straight XS2F-D421-DC0-A XS2F-D421-GC0-A
L-shape XS2F-D422-DC0-A XS2F-D422-GC0-A
Straight XS2F-D421-DD0 XS2F-D421-GD0
L-shape XS2F-D422-DD0 XS2F-D422-GD0
Straight XS2F-D421-D80-A XS2F-D421-G80-A
M12
L-shape XS2F-D422-D80-A XS2F-D422-G80-A
Straight XS2F-A421-DB0-A XS2F-A421-GB0-A
L-shape XS2F-A422-DB0-A XS2F-A422-GB0-A
Smartclick Connector,
Straight
Connector Cable length 2m Cable length 5m
CablConnector
model number
XS5F-D421-D80-A XS5F-D421-G80-A E2E-X
CablConnector
model number
Applicable Proximity
Sensor model
E2E-X@D1-M1G(J) 1
E2E-X@E1-M1 E2E-X@F1-M1
E2E-X@D1-M1J-T 3 E2E-X@D1-M1 2 E2E-X@D1-M1J-T 3 E2E-X@D1-M1 2 E2E-X@D2-M1G(J) 6 E2E-X@D2-M1J-T 8 E2E-X@D2-M1 7 E2E-X@D1S-M1 5 E2E-X@E2-M1
E2E-X@F2-M1 E2E-X@D2-M1G(J) 6 E2E-X@D2-M1J-T 8 E2E-X@D2-M1 7 E2E-X@D1S-M1 5 E2E-X@E2-M1
E2E-X@F2-M1
E2E-X@Y1-M1 14
number
@D1-M1TGJ 16
Connection
diagram
No. *2
10
11
11
Smartclick Connector,
H
IM8
Note: Refer to Introduction to Sensor I/O Connectors for details and for information on Cable length and Robotics Cables. *1. Images of straight and L-shaped connectors.
M12 Straight
*2. Refer to Connection Diagrams on page 25 for information on Proximity Sensor and I/O Connector connections.
Straight
Oil-resistant
Reinforced Cables
Straight XS3F-M421-402-A XS3F-M421-405-A
L-shape XS3F-M422-402-A XS3F-M422-405-A
M12 L-shape
XS5F-D421-D80-P XS5F-D421-G80-P
M8 Straight
M8 L-shape
E2E-X@D1-M1TGJ-U 17
E2E-X@D2-M1TGJ-U 18
E2E-X@D1-M3G 4 E2E-X@D2-M3G 9 E2E-X@E1-M3
E2E-X@F1-M3 E2E-X@E2-M3
E2E-X@F2-M3 E2E-X@D1-M3G 4 E2E-X@D2-M3G 9 E2E-X@E1-M3
E2E-X@F1-M3 E2E-X@E2-M3
E2E-X@F2-M3
12
13
12
13
24
Connections for Sensor I/O Connectors
E2E
Connection
diagram No.
1
2
3
4
5
6
7
Type
DC 2-wire (IEC pin wiring)
DC 2-wire (previous pin wiring)
DC 2-wire (no polarity)
DC 2-wire (M8 connector)
DC 2-wire (diagnostic type)
DC 2-wire (IEC pin wiring)
DC 2-wire (previous pin wiring)
Proximity Sensor
Operation
mode
NO
NC
DC 2-wire
8
(no polarity)
DC 2-wire
9
(M8 connector)
* Different from Proximity Sensor wire colors.
Model
E2E-X@D1-M1G(J)
E2E-X@D1-M1
E2E-X@D1-M1J-T
E2E-X@D1-M3G
E2E-X@D1S-M1
E2E-X@D2-M1G(J)
E2E-X@D2-M1
E2E-X@D2-M1J-T
E2E-X@D2-M3G
Sensor I/O Connector
model number
1: Straight 2: L-shape
XS2F-D42@-@A0-A
D: 2-m cable G: 5-m cable
1: Straight 2: L-shape
XS2F-D42@-@D0
D: 2-m cable G: 5-m cable
1: Straight 2: L-shape
XS2F-D42@-@D0
D: 2-m cable G: 5-m cable
1: Straight 2: L-shape
XS3F-M42@-40@-A
2: 2-m cable 5: 5-m cable
1: Straight 2: L-shape
XS2F-D42@-@80-A
D: 2-m cable G: 5-m cable
1: Straight 2: L-shape
XS2F-D42@-@80-A
D: 2-m cable G: 5-m cable
1: Straight 2: L-shape
XS2F-D42@-@80-A
D: 2-m cable G: 5-m cable
1: Straight 2: L-shape
XS2F-D42@-@80-A
D: 2-m cable G: 5-m cable
1: Straight 2: L-shape
XS3F-M42@-40@-A
2: 2-m cable 5: 5-m cable
E2E
E2E
E2E
E2E
E2E
E2E
E2E
Main
Main
Main
Main
Main
Main
Main
Main
Main
circuit
circuit
circuit
circuit
circuit
circuit
circuit
circuit
circuit
Connections
XS2FE2E
1
1
2
2
3
3
4
4
XS2FE2E
1
1
2
2
3
3
4
4
XS2F
1
1
2
2
3
3
4
4
XS3F
*
1
1
2
2
3
3
4
4
XS2F
*
1
1
2
2
3
3
4
4
XS2F
*
1
1
2
2
3
3
4
4
XS2F
*
1
1
2
2
3
3
4
4
XS2F
*
1
1
2
2
3
3
4
4
XS3F
*
1
1
2
2
3
3
4
4
Brown (+)
Blue ()
Blue () Brown (+)
Blue (+) () Brown (−) (+)
Brown (+) White (not connected) Blue (not connected)
Black ()
Brown (not connected) White (diagnostic output) (+) Blue (0 V) Black (control output) (+)
Brown (+) White ()
Blue (not connected) Black (not connected)
Brown (not connected) White (+) Blue () Black (not connected)
Brown (+)() White ()(+) Blue (not connected) Black (not connected)
Brown (+) White () Blue (not connected) Black (not connected)
25
E2E
Connection
diagram No.
10
Type
Proximity Sensor
Operation
mode
NO E2E-X@E/F1-M1
DC 3-wire
11 NC E2E-X@E2/F2-M1
12
DC 3-wire (M8 connector)
13
14
E2E-X@E1/F1-M3
NO
E2E-X@E2/F2-M3
NC
NO E2E-X@Y1-M1
AC 2-wire
15 NC E2E-X@Y2-M1
Model
Sensor I/O Connector
model number
1: Straight 2: L-shape
XS2F-D42@-@C0-A
D: 2-m cable G: 5-m cable
1: Straight 2: L-shape
XS2F-D42@-@80-A
D: 2-m cable G: 5-m cable
1: Straight 2: L-shape
XS3F-M42@-40@-A
2: 2-m cable 5: 5-m cable
1: Straight 2: L-shape
XS3F-M42@-40@-A
2: 2-m cable 5: 5-m cable
1: Straight 2: L-shape
XS2F-A42@-@B0-A
D: 2-m cable G: 5-m cable
XS2F-A421-@90-A
D: 2-m cable G: 5-m cable
E2E
E2E
E2E
E2E
E2E
E2E
Main
Main
Main
Main
Main
Main
circuit
circuit
circuit
circuit
circuit
Connections
XS2F
1
1
2
2
3
3
4
4
XS3F
1
1
2
2
3
3
4
4
XS3F
1
1
2
2
3
3
4
4
XS3F
1
1
2
2
3
3
4
4
XS2F
1
1
2
2
3
3
4
4
XS2F
*
1
1
2
2
3
3
4
4
Brown (+V)
Blue (0 V) Black (output)
Brown (+V) White (not connected)
Blue (0 V) Black (output)
Brown (+V) White (not connected) Blue (0 V) Black (output)
Brown (+V) White (output)
Blue (0 V) Black (not connected)
Brown Blue
Brown White Blue (not connected) Black (not connected)
16
NO
17
DC 2-wire (Smartclick connector)
18 NC
* Different from Proximity Sensor wire colors.
Refer to Introduction to Sensor I/O Connectors for details.
E2E-X@D1-M1TGJ
E2E-X@D1­M1TGJ-U
E2E-X@D2­M1TGJ-U
XS5F-D421-@80-A
D: 2-m cable G: 5-m cable
XS5F-D421-@80-P
D: 2-m cable G: 5-m cable
XS5F-D421-@80-P
D: 2-m cable G: 5-m cable
E2E
E2E
E2E
Main
Main
Main
circuit
circuit
circuit
XS5F
1
1
2
2
3
3
4
4
XS5F
1
1
2
2
3
3
4
4
XS5F
1
1
2
2
3
3
4
4
Brown (+) White (not connected) Blue (not connected) Black
()
Brown (+) White (not connected) Blue (not connected) Black
()
(+)
Brown White
()
Blue (not connected) Black (not connected)
26
Safety Precautions
Refer to Warranty and Limitations of Liability.
WARNING
This product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purposes.
CAUTION
Do not short the load. Explosion or burning may result.
Do not supply power to the Sensor with no load, otherwise Sensor may be damaged.
Applicable Models
E2E-CR6@ E2E-CR8@ E2E-X1@ E2E-C1@
Precautions for Correct Use
Do not use this product under ambient conditions that exceed the ratings.
Design
Influence of Surrounding Metal
When mounting the Sensor within a metal panel, ensure that the clearances given in the following table are maintained. Failure to maintain these distances may cause deterioration in the performance of the Sensor.
l
d dia.
m
D
Influence of Surrounding Metal (Unit: mm)
Model Item M8 M12 M18 M30
Shielded
DC 2-Wire Models E2E-X@D@
AC/DC 2-Wire Models E2E-X@T1
Unshielded
DC 3-Wire Models E2E-X@E@ E2E-X@F@
AC 2-Wire Models E2E-X@Y@
DC 3-Wire Models E2E-X@C/B@ E2E-C@C/B@
Model Item 3 dia. 4 dia. M5 5.4 dia.
Shielded
Unshielded
Shielded
n
m
l
l0
d 8 12 18 30
D0
m 4.5 82040
n 12182745
l 12152230
d 24407090
D 12152230
m 8 20 40 70
n 24407090
l0
d 8 12 18 30
D0
m 4.5 82040
n 12182745
l 6 15 22 30
d 24405590
D 6 15 22 30
m 8 20 40 70
n 24365490
l0
d 3455.4
D0
m22.43
n6 8
Relationship between Sizes and Models
Model Model
3 dia.
4 dia.
M5
5.4 dia.
M8
M12
M18
M30
Shielded
Shielded
Unshielded
Shielded
Unshielded
Shielded
Unshielded
Shielded
Unshielded
E2E-CR6C/B E2E-CR8C@ E2E-CR8B@ E2E-X1C@ E2E-X1B@ E2E-C1C@ E2E-C1B@ E2E-X2D@ E2E-X1R5E@ E2E-X1R5F@ E2E-X1R5Y@ E2E-X4MD@ E2E-X2ME@ E2E-X2MF@ E2E-X2MY@ E2E-X3D@ E2E-X2E@ E2E-X2F@ E2E-X2Y@ E2E-X3T1 E2E-X8MD@ E2E-X5ME@ E2E-X5MF@ E2E-X5MY@ E2E-X7D@ E2E-X5E@ E2E-X5F@ E2E-X5Y@ E2E-X7T1 E2E-X14MD@ E2E-X10ME@ E2E-X10MF@ E2E-X10MY@ E2E-X10D@ E2E-X10E@ E2E-X10F@ E2E-X10Y@ E2E-X10T1 E2E-X20MD@ E2E-X18ME@ E2E-X18MF@ E2E-X18MY@
E2E
27
E2E
Mutual Interference
When installing Sensors face-to-face or side-by-side, ensure that the minimum distances given in the following table are maintained.
A
Mutual Interference (Unit: mm)
Model Item M8 M12 M18 M30
DC 2-Wire Models E2E-X@D@
AC/DC 2-Wire Models E2E-X@T1
DC 3-Wire Models E2E-X@E@/X@F@
AC 2-Wire Models E2E-X@Y@
Shielded
Unshielded
Shielded
Unshielded
A 20 30 (20) 50 (30) 100 (50)
B 15 20 (12) 35 (18) 70 (35)
A 80 120 (60) 200 (100) 300 (100)
B 60 100 (50) 110 (60) 200 (100)
A 20 30 (20) 50 (30) 100 (50)
B 15 20 (12) 35 (18) 70 (35)
A 80 120 (60) 200 (100) 300 (100)
B 60 100 (50) 110 (60) 200 (100)
Model Item 3 dia. 4 dia. M5 5.4 dia.
B
DC 3-Wire Models E2E-X@C/B@ E2E-C@C/B@
Shielded
A20
B15
Note: Values in parentheses apply to Sensors operating at different frequencies.
Loads with Large Surge Currents (E2E-X@T@)
If a load with a large surge current is connected, such as a relay, lamp, or motor, the surge current may cause the load short-circuit protection circuit to operate, resulting in operating errors.
Mounting
Tightening Force
Do not tighten the nut with excessive force. A washer must be used with the nut.
Shielded Models Unshielded Models
Part B Part A Part B Part A
Note: 1. The allowable tightening strength depends on the distance from the
edge of the head, as shown in the following table. (A is the distance from the edge of the head. B includes the nut on the head side. If the edge of the nut is in part A, the tightening torque for part A applies instead.)
2. The following strengths assume washers are being used.
Model
Dimension
M5 1 N·m
Shielded 9
M8
Unshielded 3
M12 30 N·m
M18 70 N·m
M30 180 N·m
Part A Part B
Torque Torque
9 N·m 12 N·m
Refer to the following to mount the E2E-CR6, E2E-CR8 and E2E-C1 Unthreaded Cylindrical Models.
E2E-CR6 E2E-CR8, E2E-C1
9 to 21 mm 8 to 21 mm
Dimpled end of set screw (M3)
(No screws are provided with the E2E-CR8 or E2E-C1.)
When using a set screw, tighten it to a torque of 0.2 N·m max. (E2E-C1: 0.4 N·m max.)
Connecting a DC 2-Wire Proximity Sensor to a PLC (Programmable Controller)
Required Conditions
Connection to a PLC is possible if the specifications of the PLC and the Proximity Sensor satisfy the following conditions. (The meanings of the symbols are given at the right.)
1. The ON voltage of the PLC and the residual voltage of the Proximity Sensor must satisfy the following.
ON VCC− VR
V
2. The OFF current of the PLC and the leakage current of the Proximity Sensor must satisfy the following.
OFF Ileak
I (If the OFF current is not listed in the PLC’s input specifications, take it to be 1.3 mA.)
3. The ON current of the PLC and the control output of the Proximity Sensor must satisfy the following.
OUT (min.) ≤ ION IOUT (max.)
I The ON current of the PLC will vary, however, with the power supply voltage and the input impedance, as shown in the following equation.
ON = (VCC VR VPC)/RIN
I
Example
In this example, the above conditions are checked when the PLC Unit is the C200H-ID212, the Proximity Sensor is the E2E-X7D1-N, and the power supply voltage is 24 V.
ON (14.4 V) ≤ VCc (20.4 V) − VR (3 V) = 17.4 V:OK
1. V
2. I
OFF (1.3 mA) ≥ Ileak (0.8 mA): OK ON = [VCC (20.4 V) − VR (3 V) − VPLC (4 V)]/RIN (3 kΩ) = Approx. 4.5 mA
3. I Therefore, I Connection is thus possible.
OUT (min.) (3 mA) ≤ ION (4.5 mA): OK
VON:ON voltage of PLC (14.4 V)
ON: ON current of PLC (typically 7 mA)
I I
OFF: OFF current of PLC (1.3 mA)
IN: Input impedance of PLC (3 kΩ)
R
PC: Internal residual voltage of PLC (4 V)
V V
R: Output residual voltage of Proximity Sensor
(3 V)
leak: Leakage current of Proximity Sensor
I
(0.8 mA)
OUT Control output of Proximity Sensor (3 to
I
100 mA)
CC: Power supply voltage (PLC: 20.4 to 26.4 V)
V Values in parentheses apply to the following PLC model and Proximity Sensor model. PLC: C200H-ID212 Sensor: E2E-X7D1-N
28
E2E
Dimensions
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
Main Units
Model Number-Dimensions Drawing Number Lookup Table
Model Shielded Model No. Model No. Model No. Model No.
Shielded
Pre-wired Models
Unshielded
Shielded
Connector Models (M12)
Unshielded
Connector Models (M8)
Shielded
Unshielded E2E-X4MD@-M3G 29 E2E-X2ME/F@-M3 29
Shielded
Pre-wired Connector Models
Unshielded
Pre-wired Connector Models (no polarity)
Note 1. Two clamping nuts and one toothed washer are provided with M8 to M30 Models.
2. The model numbers of M8 to M30 Pre-wired Models are laser-marked on the milled section and cable section. This does not apply, however, to models that
Shielded
end in -U.
Model DC 2-Wire Models DC 3-Wire Models AC 2-Wire Models AC/DC 2-Wire Models
3 dia. 4 dia. E2E-CR8@ 2 M5 E2E-X1@ 4
---
E2E-CR6@ 1
---
5.4 dia. E2E-C1@ 3 M8 E2E-X2D@ 5 E2E-X1R5E@/F@ 5 E2E-X1R5Y@ 7 M12 E2E-X3D@ 9 E2E-X2E@/F@ 9 E2E-X2Y@ 11 E2E-X3T1 13 M18 E2E-X7D@ 14 E2E-X5E@/F@ 14 E2E-X5Y@ 14 E2E-X7T1 14 M30 E2E-X10D@ 16 E2E-X10E@/F@ 16 E2E-X10Y@ 16 E2E-X10T1 16 M8 E2E-X4MD@ 6 E2E-X2ME@/F@ 6 E2E-X2MY@ 8 M12 E2E-X8MD@ 10 E2E-X5ME@/F@ 10 E2E-X5MY@ 12 M18 E2E-X14MD@ 15 E2E-X10ME@/F@ 15 E2E-X10MY@ 15 M30 E2E-X20MD@ 17 E2E-X18ME@/F@ 17 E2E-X18MY@ 17 M8 E2E-X2D@-M1(G) 18 E2E-X1R5E/F@-M1 18 --­M12 E2E-X3D@-M1(G) 20 E2E-X2E/F@-M1 20 E2E-X2Y@-M1 22 M18 E2E-X7D@-M1(G) 24 E2E-X5E/F@-M1 24 E2E-X5Y@-M1 24 M30 E2E-X10D@-M1(G) 26 E2E-X10E/F@-M1 26 E2E-X10Y@-M1 26 M8 E2E-X4MD@-M1(G) 19 E2E-X2ME/F@-M1 19 --­M12 E2E-X8MD@-M1(G) 21 E2E-X5ME/F@-M1 21 E2E-X5MY@-M1 23 M18 E2E-X14MD@-M1(G) 25 E2E-X10ME/F@-M1 25 E2E-X10MY@-M1 25 M30 E2E-X20MD@-M1(G) 27 E2E-X18ME/F@-M1 27 E2E-X18MY@-M1 27
E2E-X2D@-M3G 28 E2E-X1R5E/F@-M3 28
M8
--- ---
M8 E2E-X2D@-M1(T)GJ(-U) 30 M12 E2E-X3D@-M1(T)GJ(-U) 31 M18 E2E-X7D@-M1(T)GJ(-U) 33
--- --- ---
M30 E2E-X10D@-M1(T)GJ(-U) 35
M12 E2E-X8MD1-M1(T)GJ 32
M18 E2E-X14MD1-M1(T)GJ 34
--- --- ---
M30 E2E-X20MD1-M1(T)GJ 36
M12 E2E-X3D1-M1J-T 31 M18 E2E-X7D@-M1J-T 33
--- --- ---
M30 E2E-X10D@-M1J-T 35
(Unit: mm)
---
---
---
---
Pre-wired Models (Shielded)
Diagram 1 E2E-CR6B@/CR6C@
±0.1
3 dia.
*2.4-dia. vinyl-insulated round cable with 3 conductors
(Conductor cross section: 0.08 mm
27
17
Operation indicator (red)
2
, Insulator diameter: 0.7 mm)
*
Diagram 2 E2E-CR8B@/CR8C@
4 dia.
*2.9-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section:
2
0.14 mm
, Insulator diameter: 0.9 mm), Standard length: 2 m
Robotics Cable Models:
2.9-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section:
2
0.15 mm
, Insulator diameter: 1.05 mm), Standard length: 2 m
The cable can be extended up to 100 m (separate metal conduit).
25
17.5
Operation indicator (red)
*
Diagram 3 E2E-C1B@/C1C@
5.4 dia.
*2.9-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section:
2
, Insulator diameter: 0.9 mm), Standard length: 2 m
0.14 mm Robotics Cable Models:
2.9-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section:
2
0.15 mm
, Insulator diameter: 1.05 mm), Standard length: 2 m
The cable can be extended up to 100 m (separate metal conduit).
25
17.5
Operation indicator (red)
*
Mounting Hole Dimensions
F
Dimension 3 dia. 4 dia. 5.4 dia.
F (mm) 3.3 dia. 4.2 dia. 5.7 dia.
+0.3
0
+0.5
0
+0.5
0
29
E2E
Pre-wired Models (Shielded)
Mounting Hole Dimensions
Diagram 4 E2E-X1B@/X1C@
10 dia.
8
M5 × 0.5
*2.9-dia. vinyl-insulated round cable with 3 conductors (Conductor cross
section: 0.14 mm Robotics Cable Models:
2.9-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.15 mm The cable can be extended up to 100 m (separate metal conduit).
25
17.5 15
4
Operation indicator (red)
Two clamping nuts
Two toothed washers
2
, Insulator diameter: 0.9 mm), Standard length: 2 m
2
, Insulator diameter: 1.05 mm), Standard length: 2 m
*
Diagram 5 E2E-X2D@
E2E-X1R5E@/F@
7
15 dia.
13
M8 × 1
*1. 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter:
1.3 mm), Standard length: 2 m
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm
mm), Standard length: 2 m Robotics Cable Models: 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm
1.27 mm), Standard length: 2 m
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm
1.27 mm), Standard length: 2 m Models with Highly Oil-resistant Cables: 4-dia. polyurethane-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm
diameter: 1.3 mm), Standard length: 2 m The cable can be extended up to 200 m (separate metal conduit). *2. D1 Models: Operation indicator (red) and setting indicator (green), D2/E/F Models: Operation indicator (red)
30
26
3
Two clamping nuts
Toothed washer
8
Indicators *2
*1
2
, Insulator diameter: 1.3
2
, Insulator diameter:
2
, Insulator diameter:
2
, Insulator
Dimension M5 M8 M12
F (mm) 5.5 dia. 8.5 dia. 12.5 dia.
+0.5
0
+0.5
0
F
Pre-wired Models (Unshielded)
Diagram 6 E2E-X4MD@
E2E-X2ME@/F@
30
15 dia.
13
26
63
6.1 dia.
M8 × 1
*1. 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter:
1.3 mm), Standard length: 2 m
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm
mm), Standard length: 2 m Robotics Cable Models: 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm
mm), Standard length: 2 m 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm
mm), Standard length: 2 m The cable can be extended up to 200 m (separate metal conduit). *2. D1 Models: Operation indicator (red) and setting indicator (green), D2/E/F Models: Operation indicator (red)
7
8
Indicators *2
Two clamping nuts
Toothed washer
*1
+0.5
0
2
, Insulator diameter: 1.3
2
, Insulator diameter: 1.27
2
, Insulator diameter: 1.27
Diagram 7 E2E-X1R5Y@
15 dia.
13
M8 × 1
3
36
Toothed washer
40
Two clamping nuts
7
8
Operation indicator (red)
4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm diameter: 1.3 mm), Standard length: 2 m The cable can be extended up to 200 m (separate metal conduit).
*
2
, Insulator
Diagram 9 E2E-X3D@
E2E-X2E@/F@
21 dia.
17
M12 × 1
*1. 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter:
1.3 mm), Standard length: 2 m
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm
mm), Standard length: 2 m Robotics Cable Models: 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm
mm), Standard length: 2 m 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm
mm), Standard length: 2 m Models with Highly Oil-resistant Cables: 4-dia. polyurethane-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm
diameter: 1.3 mm), Standard length: 2 m The cable can be extended (separate metal conduit) up to 200 m for the control output and up to 100 m for the
diagnostic output. *2. D1 Models: Operation indicator (red) and setting indicator (green), D2/E/F Models: Operation indicator (red)
38
33
4
Two clamping nuts
Toothed washer
9
10
Indicators * 2
*1
2
, Insulator diameter: 1.3
2
, Insulator diameter: 1.27
2
, Insulator diameter: 1.27
2
, Insulator
Diagram 8 E2E-X2MY@
15 dia.
13
6.1 dia.
M8 × 1
63
40
36
Toothed washer
7
8
Operation indicator (red)
Two clamping nuts
4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm
1.3 mm), Standard length: 2 m The cable can be extended up to 200 m (separate metal conduit).
*
2
, Insulator diameter:
Diagram 10 E2E-X8MD@
E2E-X5ME@/F@
21 dia.
17
38
33
74
9 dia.
M12 × 1
*1. 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm
1.3 mm), Standard length: 2 m
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm
mm), Standard length: 2 m Robotics Cable Models: 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm
mm), Standard length: 2 m 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm
mm), Standard length: 2 m The cable can be extended (separate metal conduit) up to 200 m for the control output and up to 100 m for the
diagnostic output. *2. D1 Models: Operation indicator (red) and setting indicator (green), D2/E/F Models: Operation indicator (red)
9
10
Indicators *2
Two clamping nuts
Toothed washer
*1
2
, Insulator diameter: 1.3
2
, Insulator diameter: 1.27
2
, Insulator diameter: 1.27
,
2
Insulator diameter:
30
E2E
Diagram 11 E2E-X2Y@
21 dia.
17
M12 × 1
4
38
Toothed washer
43
Two clamping nuts
9
10
Operation indicator (red)
4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm Insulator diameter: 1.3 mm), Standard length: 2 m The cable can be extended up to 200 m (separate metal conduit).
*
Diagram 12 E2E-X5MY@
21 dia.
17
9 dia.
2
,
74
M12 × 1
43
38
Two clamping nuts Toothed washer
10
4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm Insulator diameter: 1.3 mm), Standard length: 2 m The cable can be extended up to 200 m (separate metal conduit).
Pre-wired Models (Shielded)
Mounting Hole Dimensions
Dimension M8 M12 M18 M30
F (mm) 8.5 dia. 12.5 dia. 18.5 dia. 30.5 dia.
+0.5
0
+0.5
0
F
Diagram 13 E2E-X3T1 Pre-wired Models (Unshielded)
21 dia.
17
60
55
4
9
10
9
Operation indicator (red)
+0.5
0
*
2
,
+0.5
0
*1
M12 × 1
Two clamping nuts
*1 4-dia. vinyl-insulated round cable with 2
Toothed washer
conductors (Conductor cross section: 0.3 mm Insulator diameter: 1.3 mm), Standard length: 2 m The cable can be extended up to 200 m (separate metal conduit).
*2 Operation indicator (red), Setting indicator (green)
Indicators *2
Diagram 14 E2E-X7D@/E2E-X5E@/F@
E2E-X5Y@/E2E-X7T1
29 dia.
24
M18 × 1
*1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm
Insulator diameter: 1.9 mm), Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm
Insulator diameter: 1.9 mm), Standard length: 2 m Robotics Cable Models: 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm
Insulator diameter: 1.74 mm), Standard length: 2 m 6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm
Insulator diameter: 1.74 mm), Standard length: 2 m
Models with Highly Oil-resistant Cables:
6-dia. polyurethane-insulated round cable with 2 conductors (Conductor cross section: 0.5
2
mm
, Insulator diameter: 1.9 mm), Standard length: 2 m
The cable can be extended (separate metal conduit) up to 200 m for the control output and
up to 100 m for the diagnostic output. *2. D1/T Models: Operation indicator (red), Setting indicator (green) D2/E/F/Y Models: Operation indicator (red)
43
38
4
Toothed washer
Two clamping nuts
10
12
Indicators *2
*1
2
,
Diagram 15 E2E-X14MD@/E2E-X10ME@/F@
E2E-X10MY@
29 dia.
24
14.8 dia.
M18 × 1
2
2
,
2
,
2
,
*1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm
,
Insulator diameter: 1.9 mm), Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm
Insulator diameter: 1.9 mm), Standard length: 2 m Robotics Cable Models: 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm
Insulator diameter: 1.74 mm), Standard length: 2 m 6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm
Insulator diameter: 1.74 mm), Standard length: 2 m The cable can be extended (separate metal conduit) up to 200 m for the control output
and up to 100 m for the diagnostic output.
*2. D1/T Models: Operation indicator (red), Setting indicator (green)
D2/E/F/Y Models: Operation indicator (red)
43
38
4
10
12
10
Indicators *2
Two clamping nuts
Toothed washer
*1
*1
2
,
2
,
2
,
2
,
31
E2E
@
@
Diagram 16 E2E-X10D@/E2E-X10E@/F
E2E-X10Y@/E2E-X10T1
42 dia.
36
M30 × 1.5
*1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm
Insulator diameter: 1.9 mm), Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm
Insulator diameter: 1.9 mm), Standard length: 2 m Robotics Cable Models: 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm
Insulator diameter: 1.74 mm), Standard length: 2 m 6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm
Insulator diameter: 1.74 mm), Standard length: 2 m Models with Highly Oil-resistant: 6-dia. polyurethane-insulated round cable with 2 conductors (Conductor cross section:
2
, Insulator diameter: 1.9 mm), Standard length: 2 m
0.5 mm
The cable can be extended (separate metal conduit) up to 200 m for the control output
and up to 100 m for the diagnostic output. *2. D1/T Models: Operation indicator (red), Setting indicator (green) D2/E/F/Y Models: Operation indicator (red)
43
5
Toothed washer
48
Two clamping nuts
10
12
Indicators *2
*1
M8 Connector Models (Shielded)
Diagram 17 E2E-X20MD@/E2E-X18ME@/F
E2E-X18MY@
48
42 dia.
36
26.8 dia.
M30 × 1.5
2
,
*1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm
2
,
2
,
2
,
Insulator diameter: 1.9 mm), Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm
Insulator diameter: 1.9 mm), Standard length: 2 m Robotics Cable Models: 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm
Insulator diameter: 1.74 mm), Standard length: 2 m 6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm
Insulator diameter: 1.74 mm), Standard length: 2 m The cable can be extended (separate metal conduit) up to 200 m for the control output
and up to 100 m for the diagnostic output. *2. D1/T Models: Operation indicator (red), Setting indicator (green) D2/E/F/Y Models: Operation indicator (red)
43
13
5
12
10
Indicators *2
Two clamping nuts
Toothed washer
M8 Connector Models (Unshielded)
*1
2
,
2
,
2
,
2
,
Diagram 28 E2E-X2D@-M3G/E2E-X1R5E@-M3/X1RF@-M3
39
15 dia.
13
M8 × 1
31
26
3
Two clamping nuts
Toothed washer
8
M8 × 1
* D Models: Operation indicator (red),
D2/E/F Models: Operation indicator (red)
Indicators*
Setting indicator (green)
M12 Connector Models (Shielded)
Diagram 18 E2E-X2D@-M1(G)
E2E-X1R5E@-M1/E2E-X1R5F@-M1
43
15 dia.
13
M8 × 1
* D1 Models: Operation indicator (red),
D2/E/F Models: Operation indicator (red)
30
26
8
3
Indicators*
Two clamping nuts
Toothed washer
Setting indicator (green)
M12 × 1
Diagram 29 E2E-X4MD@-M3G/E2E-X2ME@-M3/X2MF@-M3
39
M8 × 1
6
31
26
8
3
Two clamping nuts
Toothed washer
Indicators*
M8 × 1
* D Models: Operation indicator (red),
D2/E/F Models: Operation indicator (red)
Setting indicator (green)
15 dia.
13
6.1 dia.
M12 Connector Models (Unshielded)
Diagram 19 E2E-X4MD@-M1(G)
E2E-X2ME@-M1/E2E-X2MF@-M1
43
M8 × 1
30
26
8
3
6
Toothed washer
Setting indicator (green)
M12 × 1
Indicators*
Two clamping nuts
15 dia.
13
6.1 dia.
* D1 Models: Operation indicator (red),
D2/E/F Models: Operation indicator (red)
32
E2E
(G)
Diagram 20 E2E-X3D@-M1
E2E-X2E@-M1/E2E-X2F@-M1
21 dia.
17
M12 × 1
* D1 Models: Operation indicator (red),
D2/E/F Models: Operation indicator (red)
48
33
4
10
Two clamping nuts
Toothed washer
Setting indicator (green)
M12 × 1
Indicators *
Diagram 22 E2E-X2Y@-M1
21 dia.
17
M12 × 1
38
4
Toothed washer
53
10
Operation indicator (red)
Two clamping nuts
M12 × 1
Diagram 24 E2E-X7D@-M1(G)/E2E-X5E@-M1/X5F@-M1
E2E-X5Y@-M1
29 dia.
24
53
38
4
10
M12 × 1
Diagram 21 E2E-X8MD@-M1(G)
E2E-X5ME@-M1/E2E-X5MF@-M1
7
48
33
4
Toothed washer
10
Two clamping nuts
M12 × 1
Indicators*
21 dia.
17
9 dia.
M12 × 1
* D1 Models: Operation indicator (red), Setting indicator (green) D2/E/F Models: Operation indicator (red)
Diagram 23 E2E-X5MY@-M1
21 dia.
17
7
9 dia.
M12 × 1
53
38
4
Two clamping nuts
Toothed washer
10
M12 × 1
Operation indicator (red)
Diagram 25 E2E-X14MD@-M1(G)/E2E-X10ME@-M1
X10MF@-M1 E2E-X10MY@-M1
53
29 dia.
24
38
10
4
10
M12 × 1
M18 × 1
* D1 Models: Operation indicator (red), Setting indicator (green) D2/E/Y Models: Operation indicator (red)
Toothed washer
Indicators*
Two clamping nuts
Diagram 26 E2E-X10D@-M1(G)/E2E-X10E@-M1/X10F@-M1
E2E-X10Y@-M1
42 dia.
36
M30 × 1.5
* D1 Models: Operation indicator (red), Setting indicator (green) D2/E/Y Models: Operation indicator (red)
43
5
Toothed washer
58
10
Indicators*
Two clamping nuts
M12 × 1
Mounting Hole Dimensions
Dimensions M8 M12 M18 M30
F (mm) 8.5 dia. 12.5 dia. 18.5 dia. 30.5 dia.
+0.5
0
+0.5
0
F
14.8 dia.
M18 × 1
* D1 Models: Operation indicator (red), Setting indicator (green) D2/E/Y Models: Operation indicator (red)
Indicators*
Two clamping nuts
Toothed washer
Diagram 27 E2E-X20MD@-M1(G)/E2E-X18ME@-M1/
X18MF@-M1 E2E-X18MY@-M1
42 dia.
36
* D1 Models: Operation indicator (red), Setting indicator (green) D2/E/Y Models: Operation indicator (red)
+0.5
0
+0.5
13 5
26.8 dia.
M30 × 1.5
0
58
43
Toothed washer
10
M12 × 1
Indicators*
Two clamping nuts
33
E2E
)
Pre-wired Connector Models (Shielded
Diagram 30 E2E-X2D@-M1TGJ-U *3
E2E-X2D1-M1TGJ
Diagram 31 E2E-X3D@-M1GJ
E2E-X3D1-M1J-T E2E-X3D@-M1TGJ-U *3 E2E-X3D1-M1TGJ
Diagram 33 E2E-X7D@-M1GJ
E2E-X7D@-M1J-T E2E-X7D@-M1TGJ-U *3 E2E-X7D1-M1TGJ
Diagram 35 E2E-X10D@-M1GJ
E2E-X10D@-M1J-T E2E-X10D@-M1TGJ-U *3 E2E-X10D1-M1TGJ
15 dia.
13
21 dia.
17
29 dia.
24
42 dia.
36
M12 × 1
M18 × 1
M8 × 1
5
Mounting Hole Dimensions
F
Dimension M12 M18 M30
F (mm) 12.5 dia. 18.5 dia. 30.5 dia.
30
26
3
33
4
38
4
48
43
7
8
Indicators *2
Two clamping nuts
Toothed washer
38
9
10
Indicators *2
Two clamping nuts
Toothed washer
43
10
Two clamping nuts
Toothed washer
10
12
Indicators *2
12
+0.5
0
*1
*1. No U suffix: 4-dia. Vinyl-insulated round cable U suffix: 4-dia. Polyurethane insulated round cable, Standard length: 300 mm *2. D1 Models: Operation indicator (red), Setting indicator (green) D2 Models: Operation indicator (red) *3. The connectors for M1TGJ models are XS5 Smartclick connectors.
*1
*1. No U suffix: 4-dia. Vinyl-insulated round cable U suffix: 4-dia. Polyurethane insulated round cable, Standard length: 300 mm *2. D1 Models: Operation indicator (red), Setting indicator (green) D2 Models: Operation indicator (red) *3. The connectors for M1TGJ models are XS5 Smartclick connectors.
*1
*1. No U suffix: 6-dia. Vinyl-insulated round cable U suffix: 6-dia. Polyurethane insulated round cable, Standard length: 300 mm *2. D1 Models: Operation indicator (red), Setting indicator (green) D2 Models: Operation indicator (red) *3. The connectors for M1TGJ models are XS5 Smartclick connectors.
+0.5
0
M12 × 1
M12 × 1
M12 × 1
+0.5
0
Pre-wired Connector Models (Unshielded)
Diagram 32 E2E-X8MD1-M1GJ
E2E-X8MD1-M1TGJ
21 dia.
17
M30 × 1.5
Two clamping nuts
Toothed washer
7
9 dia.
M12 × 1
Indicators *2
38
33
10
4
Toothed washer
*1
*1. No U suffix: 6-dia. Vinyl-insulated round cable U suffix: 6-dia. Polyurethane insulated round cable, Standard length: 300 mm *2. D1 Models: Operation indicator (red), Setting indicator (green) D2 Models: Operation indicator (red) *3. The connectors for M1TGJ models are XS5 Smartclick connectors.
9
Indicators *2
Two clamping nuts
*1
*1. 4-dia. vinyl-insulated round cable,
Standard length: 300 mm
*2. Operation indicator (red), Setting
indicator (green)
M12 × 1
M12 × 1
34
E2E
4
10
13 5
M30 × 1.5
43
38
Diagram 34 E2E-X14MD@-M1GJ
E2E-X14MD1-M1TGJ
Diagram 36 E2E-X20MD1-M1GJ
E2E-X20MD1-M1TGJ
29 dia.
24
14.8 dia.
M18 × 1
42 dia.
36
26.8 dia.
Dimensions for Proximity Sensors with Sensor I/O Connectors
Shielded Models Unshielded Models
Straight Connectors
L1
L-shape Connectors
Straight Connectors
L1
L-shape Connectors
12
10
Indicators*2
Two clamping nuts
Toothed washer
48
43
10
Two clamping nuts
Toothed washer
*1
*1. 6-dia. vinyl-insulated round cable, Standard
length: 300 mm
*2. D1 Models: Operation indicator (red),
Setting indicator (green)
D2 Models: Operation indicator (red)
12
*1
Indicators*2
*1. 6-dia. vinyl-insulated round cable,
Standard length: 300 mm *2. Operation indicator (red), Setting indicator (green)
M12 × 1
M12 × 1
Dimensions with the XS2F Connected (Unit: mm)
Sensor diameter
Dimension
M8 Approx. 75 Approx. 62
M12*
DC Approx. 80 Approx. 67
AC Approx. 85 Approx. 72 M18 Approx. 85 Approx. 72 M30 Approx. 90 Approx. 77
* The overall length of the Sensor is different between AC and DC
Models for Sensors with diameters of M12. This will change the dimension when the I/O Connector is connected.
L1 L2
L2
L2
Accessories (Order Separately)
Sensor I/O Connectors
Refer to Introduction to Sensor I/O Connectors for details.
Mounting Brackets
Protective Covers
Sputter Protective Covers
Refer to Y92@ for details.
Dimensions with the XS3F Connected (Unit: mm)
Sensor diameter
Dimension
M8 Approx. 65 Approx. 54
L1 L2
35
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions.
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2012 All Right Reserved.
2012.4
Loading...