Connector Models
DC 3-wire and AC 2-wire, DC 2-wire with self-diagnosis output,
DC 2-wire with old pin arrangement (polarity)
Connector Models
DC 2-wire with IEC pin arrangement (polarity)
Pre-wired Connector Models
DC 3-wire and AC 2-wire, DC 2-wire with IEC pin arrangement
(polarity), DC 3-wire and AC 2-wire, DC 2-wire with self-diagnosis output, DC 2-wire with old pin arrangement (polarity)
Pre-wired Connector Models
DC 2-wire with IEC pin arrangement (polarity)
Pre-wired Smartclick Connector Models
DC 2-wire with IEC pin arrangement (no polarity)
Pre-wired Smartclick Connector Models
DC 2-wire with IEC pin arrangement (polarity)
New model (Applies only to DC 2-wire pre-wired and shielded
models.)
Cable length (Unit: m) (Applicable to Pre-wired Models and Prewired Connector Models.)
R6: 0.6 mm
1R5: 1.5 mm
Whether D models have
polarity is defined by number J.
Used to prevent mutual interference.
This is blank if the cable
specification in number K
is R or U.
Example:
2M
0.3M
6
Ordering Information
2-Wire Models
Shielded DC 2-wire Models with No Self-diagnostic Output [Refer to Dimensions on page 29.]
E2E
Appear-
ance
M8
M12
M18
M30
*1. Models with different frequencies are also available. The model number is E2E-X @D15 (example: E2E-X3D15-N 2M).
*2. Models with a flexible cable are also available. Add "-R" rather than "-N" to the end of the model number (example: E2E-X2D1-R 2M).
*3. The standard stock includes models with a cable length of 5 m. Specify the cable length at the end of the model number. (Example: E2E-X3D1-N 5M)
*4. Refer to page 24 for details.
*5. The residual voltage for models without polarity is 5 V, so use caution concerning the connection load interface conditions (e.g., PLC ON voltage). Refer to page 28.
*6. The standard cable length is 300 mm. Cables with a length of 500 mm and 1 m can also be manufactured.
Unshielded DC 2-Wire Models with No Self-diagnosis Output [Refer to Dimensions on page 29.]
E2E
Appear-
ance
M8
M12
M18
M30
*1. Models with different frequencies are also available. The model number is E2E-X @D15 (example: E2E-X8MD15 2M).
*2. Models with a flexible cable are also available. Add -R to the end of the model number. (example: E2E-X4MD1-R 2M).
*3. The standard stock includes models with a cable length of 5 m. Specify the cable length at the end of the model number. (Example: E2E-X4MD1 5M)
*4. Refer to page 24 for details.
Shielded DC 2-Wire Models with Self-diagnosis Output [Refer to Dimensions on page 29.]
Appear-
ance
M12
M18
M30
*1. Models with different frequencies are also available. The model number is E2E-X @D15S (example: E2E-X3D15S 2M).
*2. Refer to page 24 for details.
Sensing distance
3 mm
7 mm
10 mm
Connection
method
Pre-wired Models
(2 m)
M12 Connector
Models
Pre-wired Models
(2 m)
M12 Connector
Models
Pre-wired Models
(2 m)
M12 Connector
Models
Cable
specifications
PVC (oil-resistant)
---
PVC (oil-resistant)------E2E-X7D1S 2M *1
---
PVC (oil-resistant)------E2E-X10D1S 2M *1
---
Polar-
ity
Yes
Opera-
tion
mode
2: +V and diagnostic output
3: 0 V
4: +V and control output
NO
2: +V and diagnostic output
3: 0 V
4: +V and control output
2: +V and diagnostic output
3: 0 V
4: +V and control output
Pin
arrangement
------E2E-X3D1S 2M *1
Applicable
connector
code *2
DE2E-X3D1S-M1
DE2E-X7D1S-M1
DE2E-X10D1S-M1
Model
8
2-Wire Models
Unshielded DC 2-Wire Models with Self-diagnosis Output [Refer to Dimensions on page 29.]
E2E
Appear-
ance
M12
M18
M30
*1. Models with different frequencies are also available. The model number is E2E-X @MD15S (example: E2E-X8MD15S 2M).
*2. Refer to page 24 for details.
Sensing distance
8 mm
14 mm
20 mm
Connection
method
Pre-wired Models (2 m)
M12 Connector
Models
Pre-wired Models (2 m)
M12 Connector
Models
Pre-wired Models (2 m)
M12 Connector
Models
Cable
specifications
PVC (oil-resistant)
---
PVC (oil-resistant)------E2E-X14MD1S 2M *
---
PVC (oil-resistant)------E2E-X20MD1S 2M *
---
Polar-
ity
Yes
Opera-
tion
mode
2: +V and diagnostic output
3: 0 V
4: +V and control output
NO
2: +V and diagnostic output
3: 0 V
4: +V and control output
2: +V and diagnostic output
3: 0 V
4: +V and control output
Pin
arrangement
------E2E-X8MD1S 2M *
Connector Pin Assignments of DC 2-Wire Models
• The connector pin assignments of each New E2E DC 2-Wire Model
conform to IEC 947-5-2 Table III. (Only DC 2-Wire Models have
been changed in comparison to the previous models.)
• The following models with conventional connector pin assignments
are available as well. (Only NO Models can be used.)
The cable at the right should also be used if the XW3A-P@45-G11
Connector Junction Box is already being used.
Cable lengthModel
500 mmXS2W-D421-BY1
Internal Wiring
(Proximity Sensor end)(Wired end)
1
4
Models with conventional connector pin assignments are available as well.
AC 2-Wire Models Shielded Models [Refer to Dimensions on page 29.]
E2E
Appear-
ance
M8
M12
M18
M30
*1. Models with different frequencies are also available. The model number is E2E-X @Y@5 (example: E2E-X5Y15 2M).
*2. The standard stock includes models with a cable length of 5 m. Specify the cable length at the end of the model number. (Example: E2E-X2Y1 5M)
*3. Refer to page 24 for details.
Sensing distance
1.5 mm
2 mm
5 mm
10 mm
Connection
method
Pre-wired Models
(2 m)
Pre-wired Models
(2 m)
M12 Connector
Models
Pre-wired Models
(2 m)
M12 Connector
Models
Pre-wired Models
(2 m)
M12 Connector
Models
Cable
specifications
PVC (oil-resistant)
PVC (oil-resistant)
---
PVC (oil-resistant)
---
PVC (oil-resistant)
---
Operation
mode
NO
NCE2E-X1R5Y2 2M
NO
NCE2E-X2Y2 2M
NO(3, 4): (AC, AC)EE2E-X2Y1-M1
NC(1, 2): (AC, AC)FE2E-X2Y2-M1
NO
NCE2E-X5Y2 2M
NO(3, 4): (AC, AC)EE2E-X5Y1-M1
NC(1, 2): (AC, AC)FE2E-X5Y2-M1
NO
NCE2E-X10Y2 2M
NO(3, 4): (AC, AC)EE2E-X10Y1-M1
NC(1, 2): (AC, AC)FE2E-X10Y2-M1
Pin
arrangement
------
------
------
------
Applicable con-
nector code *3
E2E-X1R5Y1 2M
E2E-X2Y1 2M *1*2
E2E-X5Y1 2M *1*2
E2E-X10Y1 2M *1*2
Model
Unshielded Models
Appear-
ance
M8
M12
M18
M30
*1. Models with different frequencies are also available. The model number is E2E-X @MY@5 (example: E2E-X5MY15 2M).
*2. The standard stock includes models with a cable length of 5 m. Specify the cable length at the end of the model number. (Example: E2E-X5MY1 5M)
*3. Refer to page 24 for details.
Sensing distance
2 mm
5 mm
10 mm
18 mm
Connection
method
Pre-wired Models
(2 m)
Pre-wired Models
(2 m)
M12 Connector
Models
Pre-wired Models
(2 m)
M12 Connector
Models
Pre-wired Models
(2 m)
M12 Connector
Models
Cable
specifications
PVC (oil-resistant)
PVC (oil-resistant)
---
PVC (oil-resistant)
---
PVC (oil-resistant)
---
Operation
mode
NO
NCE2E-X2MY2 2M
NO
NCE2E-X5MY2 2M
NO(3, 4): (AC, AC)EE2E-X5MY1 2M
NC(1, 2): (AC, AC)FE2E-X5MY2-M1
NO
NCE2E-X10MY2 2M
NO(3, 4): (AC, AC)EE2E-X10MY1-M1
NC(1, 2): (AC, AC)FE2E-X10MY2-M1
NO
NCE2E-X18MY2 2M
NO(3, 4): (AC, AC)EE2E-X18MY1-M1
NC(1, 2): (AC, AC)FE2E-X18MY2-M1
Pin
arrangement
------
------
------
------
Applicable con-
nector code *3
E2E-X2MY1 2M
E2E-X5MY1 2M *1*2
E2E-X10MY1 2M *1
E2E-X18MY1 2M *1
Model
AC 2-Wire Models Shielded Models [Refer to Dimensions on page 29.]
(There are no unshielded models.)
Appear-
ance
M12
M18
M30
Note: Not compliant with CE.
* The standard stock includes models with a cable length of 5 m. Specify the cable length at the end of the model number. (Example: E2E-X7T1 5M)
Sensing distance
3 mm
7 mm
10 mm
Connection
method
Pre-wired Models
(2 m)
Pre-wired Models
(2 m)
Pre-wired Models
(2 m)
Cable
specifications
PVC (oil-resistant)
PVC (oil-resistant)
PVC (oil-resistant)
Operation
mode
NO
Pin
arrangement
------E2E-X3T1 2M
------E2E-X7T1 2M *
------E2E-X10T1 2M
Applicable con-
nector code *3
Model
10
3-Wire Models
Shielded DC 3-Wire Models [Refer to Dimensions on page 29.]
E2E
Appear-
ance
3 dia.
4 dia.
M5
5.4 dia.
M8
M12
M18
M30
*1. The standard stock includes models with a cable length of 5 m. Specify the cable length at the end of the model number. (Example: E2E-X2E1 5M)
*2. Models with a flexible cable are also available. Add -R to the end of the model number. (example: E2E-X5E1-R 2M).
*3. Models with different frequencies are also available. The model number is E2E-X@@@5 (example: E2E-X5E15 2M).
*4. Refer to page 24 for details.
Sensing distance
0.6 mm
0.8 mm
1 mm
1 mm
1.5 mm
2 mm
5 mm
10 mm
Connection
method
Pre-wired Models
(2 m)
Pre-wired Models
(2 m)
Pre-wired Models
(2 m)
Pre-wired Models
(2 m)
Pre-wired Models
(2 m)
M12 Connector
Models
M8 Connector
Models
Pre-wired Models
(2 m)
M12 Connector
Models
Pre-wired Models
(2 m)
M12 Connector
Models
Pre-wired Models
(2 m)
M12 Connector
Models
Cable
specifica-
tions
PVC (oil-resistant)
PVC (oil-resistant)
PVC (oil-resistant)
PVC (oil-resistant)
PVC (oil-resistant)
PVC (oil-resistant)
PVC (oil-resistant)
PVC (oil-resistant)
PVC (oil-resistant)
Opera-
tion
mode
NO
NCE2E-CR6C2 2ME2E-CR6B2 2M
NO
NCE2E-CR8C2 2ME2E-CR8B2 2M
NO
NCE2E-X1C2 2ME2E-X1B2 2M
NO
NCE2E-C1C2 2ME2E-C1B2 2M
NO
NCE2E-X1R5E2 2ME2E-X1R5F2 2M
---
---
---
---
---
NO
NC
NO
NC
NO
NCE2E-X2E2 2ME2E-X2F2 2M
NO
NC
NO
NCE2E-X5E2 2ME2E-X5F2 2M
NO
NC
NO
NCE2E-X10E2 2ME2E-X10F2 2M
NO
NC
Pin
arrangement
------
------
------
------
------
1: +V, 3: 0 V,
4: Control output
1: +V, 3: 0 V,
2: Control output
1: +V, 3: 0 V,
4: Control output
1: +V, 3: 0 V,
2: Control output
------
1: +V, 3: 0 V,
4: Control output
1: +V, 3: 0 V,
2: Control output
------
1: +V, 3: 0 V,
4: Control output
1: +V, 3: 0 V,
2: Control output
------
1: +V, 3: 0 V,
4: Control output
1: +V, 3: 0 V,
2: Control output
Appli-
cable
connector code
*5
B
DE2E-X1R5E2-M1E2E-X1R5F2-M1
I
B
DE2E-X2E2-M1E2E-X2F2-M1
B
DE2E-X5E2-M1E2E-X5F2-M1
B
DE2E-X10E2-M1E2E-X10F2-M1
NPN outputPNP output
E2E-CR6C1 2ME2E-CR6B1 2M
E2E-CR8C1 2M *1*2E2E-CR8B1 2M *2
E2E-X1C1 2M *1*2E2E-X1B1 2M *2
E2E-C1C1 2M *1*2E2E-C1B1 2M
E2E-X1R5E1 2M *1*2 E2E-X1R5F1 2M *1*2
E2E-X1R5E1-M1E2E-X1R5F1-M1
E2E-X1R5E1-M3E2E-X1R5F1-M3
E2E-X1R5E2-M3E2E-X1R5F2-M3
E2E-X2E1 2M *1*2*3E2E-X2F1 2M *1*2*3
E2E-X2E1-M1E2E-X2F1-M1
E2E-X5E1 2M *1*2*3E2E-X5F1 2M *1*2*3
E2E-X5E1-M1E2E-X5F1-M1
E2E-X10E1 2M *1*2*3 E2E-X10F1 2M *2
E2E-X10E1-M1E2E-X10F1-M1
Model
11
3-Wire Models
Unshielded DC 3-Wire Models [Refer to Dimensions on page 29.]
E2E
Appear-
ance
M8
M12
M18
M30
*1. The standard stock includes models with a cable length of 5 m. Specify the cable length at the end of the model number. (Example: E2E-X5ME1 5M)
*2. Models with a flexible cable are also available. Add -R to the end of the model number. (example: E2E-X5E1-R 2M).
*3. Models with different frequencies are also available. The model number is E2E-X@M@@5 (example: E2E-X5ME15 2M).
*4. Refer to page 24 for details.
Sensing distance2 mm ±10%4 mm ±10%3 mm ±10%8 mm ±10%7 mm ±10%14 mm ±10%10 mm ±10%20 mm ±10%
Set distance *10 to 1.6 mm0 to 3.2 mm0 to 2.4 mm0 to 6.4 mm0 to 5.6 mm0 to 11.2 mm0 to 8 mm0 to 16 mm
Differential travel 15% max. of sensing distance10% max. of sensing distance
Detectable objectFerrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on pages 18 and 19.
Standard sensing
object
Response frequency
*2
Power supply voltage
(operating voltage
range)
Leakage current0.8 mA max.
Load
Control
output
Indicators
Operation mode
(with sensing object
approaching)
Diagnostic output
delay
Protection circuitsSurge suppressor, Load short-circuit protection (for control and diagnostic output)
Ambient
temperature range
Ambient
humidity range
Temperature
influence
Voltage influence±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength1000 VAC, 50/60 Hz for 1 minute between current carry parts and case
Vibration resistanceDestruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
Degree of protection
Connection methodPre-wired Models (Standard cable length: 2 m), Connector Models, or Pre-wired Connector Models (Standard cable length: 0.3 m)
Weight
(packed
state)
Materials
AccessoriesInstruction manual
*1. Use the E2E within the range in which the setting indicator (green LED) is ON (except D2 Models).
*2. The response frequency is an average value.
Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
*3. The residual voltage of each M1J-T Model is 5 V. When connecting to a device, make sure that the device can withstand the residual voltage. (Refer to page 28 for
details.)
current
Residual
voltage
*3
Pre-wired
Models
Pre-wired
Connector
Models
Connector
Models
CaseStainless steel (SUS303)Nickel-plated brass
Sensing surface
Clamping
nuts
Toothed
washer
Iron,
8 × 8 × 1mm
1.5 kHz1 kHz0.8 kHz0.5 kHz0.4 kHz0.1 kHz
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
3 to 100 mA, Diagnostic output: 50 mA for -D1(5)S Models
3 V max. (Load current: 100 mA, Cable length: 2 m, M1J-T Models only: 5 V max.)
Sensing distance1.5 mm ±10%2 mm ±10%5 mm ±10%10 mm ±10%18 mm ±10%
Set distance0 to 1.2 mm0 to 1.6 mm0 to 4 mm0 to 8 mm0 to 14 mm
Differential travel10% max. of sensing distance
Detectable objectFerrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 19.)
Standard sensing
object
Response frequency25 Hz
Power supply voltage
(operating voltage
*1
range)
Leakage current1.7 mA max.
Load
Control
output
IndicatorsOperation indicator (red)
Operation mode
(with sensing object
approaching)
Protection circuitsSurge suppressor
Ambient temperature
range *1*2
Ambient
humidity range
Temperature
influence
Voltage influence±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength4,000 VAC (M8 Models: 2,000 VAC), 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistanceDestruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
Degree of protection
Connection methodPre-wired Models (Standard cable length: 2 m) and Connector Models
Weight
Materials
AccessoriesInstruction manual
*1. When supplying 24 VAC to any of the above models, make sure that the operating ambient temperature range is at least −25°C.
*2. When using an M18 or M30 Connector Model at an ambient temperature between 70 and 85°C, make sure that the Sensor has a control output (load current) of
current
Residual
voltage
Prewired
Models
Model
Connector
Models
CaseStainless steel (SUS303)Nickel-plated brass
Sensing
surface
Clamping nuts
Toothed
washer
5 to 200 mA max.
Iron,
8 × 8 × 1mm
24 to 240 VAC (20 to 264 VAC), 50/60 Hz
5 to 100 mA5 to 200 mA5 to 300 mA
*2
Refer to Engineering Data on page 20.
Y1 Models: NO
Y2 Models: NC
Operating/Storage: −25 to 70°C
(with no icing or condensation)
Operating/storage: 35% to 95% (with no condensation)
±10% max. of sensing distance
at 23°C in the temperature range
of −25 to 70°C
Destruction: 500 m/s
10 times each in X, Y, and
Z directions
Approx. 60 gApprox. 70 gApprox. 130 gApprox. 175 g
Approx. 15 gApprox. 25 gApprox. 40 gApprox. 90 g
PBT
Nickel-plated brass
Zinc-plated iron
Iron, 12 × 12 × 1 mm
Refer to the timing charts under I/O Circuit Diagrams on page 23 for details.
Operating/Storage: −40 to 85°C (with no icing or condensation)
±15% max. of sensing distance at 23°C in the temperature range of −40 to 85°C,
±10% max. of sensing distance at 23°C in the temperature range of −25 to 70°C
2
Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
Iron,
15 × 15 × 1 mm
Iron,
18 × 18 × 1 mm
Iron, 30 × 30 × 1 mm
Iron,
54 × 54 × 1 mm
14
E2E
E2E-X@T1 AC/DC 2-Wire Models
SizeM12M18M30
ShieldedShielded
ItemModelE2E-X3T1E2E-X7T1E2E-X10T1
Sensing distance3 mm ±10%7 mm ±10%10 mm ±10%
Set distance0 to 2.4 mm0 to 5.6 mm0 to 8 mm
Differential travel10% max. of sensing distance
Detectable objectFerrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 18.)
Ambient temperature range Operating: −25 to 70°C, Storage: −40 to 85°C (with no icing or condensation)
Ambient humidity rangeOperating/Storage: 35% to 95% (with no condensation)
Temperature influence±10% max. of sensing distance at 23°C in the temperature range of −25 to 70°C
Voltage influence±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength4,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Vibration resistanceDestruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistanceDestruction: 1,000 m/s2 10 times each in X, Y, and Z directions
Degree of protectionIEC 60529 IP67, in-house standards: oil-resistant
Connection methodPre-wired Models (Standard cable length: 2 m)
Weight (packed state)Approx. 80 gApprox. 140 gApprox. 190 g
Materials
AccessoriesInstruction manual
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and
a set distance of half the sensing distance.
*2. Power Supply Voltage Waveform:
Use a sine wave for the power supply. Using a rectangular AC power supply may result in faulty reset.
DC1 kHz0.5 kHz0.4 kHz
AC 25 Hz
24 to 240 VDC (20 to 264 VDC)
48 to 240 VAC (40 to 264 VAC)
DC: 1 mA max.
AC: 2 mA max.
Load
current
Residual
voltage
CaseNickel-plated brass
Sensing
surface
Clamping
nuts
Toothed
washer
5 to 100 mA
DC: 6 V max. (Load current: 100 mA, Cable length: 2 m)
AC: 10 V max. (Load current: 5 mA, Cable length: 2 m)
NO (Refer to the timing charts under I/O Circuit Diagrams on page 21 for details.)
Voltage influence±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength1,000 VAC, 50/60 Hz for 1 minute between current carry parts and case
Vibration resistanceDestruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
Degree of protection
Connection methodPre-wired Models (Standard cable length: 2 m) and Connector Models
Weight
Materials
AccessoriesInstruction manual
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and
*2. When using an M8 Model at an ambient temperature between 70 and 85°C, supply 10 to 30 VDC to the Sensor and make sure that the Sensor has a control output
12 to 24 VDC (10 to 40 VDC), ripple (p-p): 10% max.
200 mA max.
2 V max. (Load current: 200 mA, Cable length: 2 m)
E1/F1 Models: NO
E2/F2 Models: NC
Refer to the timing charts under I/O Circuit Diagrams on page 21 for details.
Operating/Storage: −40 to 85°C (with no icing or condensation)
Operating/Storage: 35% to 95% (with no condensation)
±15% max. of sensing distance at 23°C in the temperature range of −40 to 85°C
±10% max. of sensing distance at 23°C in the temperature range of −25 to 70°C
Destruction: 500 m/s
10 times each in X, Y, and
Z directions
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength500 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistanceDestruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistanceDestruction: 500 m/s2 10 times each in X, Y, and Z directions
Degree of protectionIEC 60529 IP66IEC 60529 IP67, in-house standards: oil-resistant
Connection methodPre-wired Models (Standard cable length: 2 m)
Weight (packed state) Approx. 60 g
Materials
AccessoriesInstruction manual
* The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and
a set distance of half the sensing distance.
current
Residual
voltage
CaseStainless steel (SUS303)Nickel-plated brass
Sensing
surface
Clamping
nuts
Toothed
washer
Iron, 3 × 3 × 1 mmIron, 5 × 5 × 1 mm
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Open-collector output,
80 mA max. (30 VDC max.)
1 V max.
(Load current: 80 mA,
Cable length: 2 m)
C1/B1 Models: NO
C2 Models: NC
Operating/Storage: −25 to 70°C (with no icing or condensation)
Operating/Storage: 35% to 95% (with no condensation)
±15% max. of sensing distance at 23°C in the temperature range of −25 to 70°C
±5% max. of sensing distance at
rated voltage in the rated voltage
±10% range
Heat-resistant ABS
Nickel-plated brass (E2E-X1C/B@ only)
Zinc-plated iron (E2E-X1C/B@ only)
Refer to the timing charts under I/O Circuit Diagrams on page 22 for details.
Open-collector output, 100 mA max. (30 VDC max.)
2 V max. (Load current: 100 mA, Cable length: 2 m)
±2.5% max. of sensing distance at rated voltage in the rated voltage ±15% range
Note: Refer to Introduction to Sensor I/O Connectors for details and for information on Cable length and Robotics Cables.
*1. Images of straight and L-shaped connectors.
M12 Straight
*2. Refer to Connection Diagrams on page 25 for information on Proximity Sensor and I/O Connector connections.
Brown (+)
White (not connected)
Blue (not connected)
Black (−)
Brown (not connected)
White (diagnostic output) (+)
Blue (0 V)
Black (control output) (+)
Brown (+)
White (−)
Blue (not connected)
Black (not connected)
Brown (not connected)
White (+)
Blue (−)
Black (not connected)
Brown (+)(−)
White (−)(+)
Blue (not connected)
Black (not connected)
Brown (+)
White (−)
Blue (not connected)
Black (not connected)
25
E2E
Connection
diagram No.
10
Type
Proximity Sensor
Operation
mode
NOE2E-X@E/F1-M1
DC 3-wire
11NCE2E-X@E2/F2-M1
12
DC 3-wire
(M8 connector)
13
14
E2E-X@E1/F1-M3
NO
E2E-X@E2/F2-M3
NC
NOE2E-X@Y1-M1
AC 2-wire
15NCE2E-X@Y2-M1
Model
Sensor I/O Connector
model number
1: Straight
2: L-shape
XS2F-D42@-@C0-A
D: 2-m cable
G: 5-m cable
1: Straight
2: L-shape
XS2F-D42@-@80-A
D: 2-m cable
G: 5-m cable
1: Straight
2: L-shape
XS3F-M42@-40@-A
2: 2-m cable
5: 5-m cable
1: Straight
2: L-shape
XS3F-M42@-40@-A
2: 2-m cable
5: 5-m cable
1: Straight
2: L-shape
XS2F-A42@-@B0-A
D: 2-m cable
G: 5-m cable
XS2F-A421-@90-A
D: 2-m cable
G: 5-m cable
E2E
E2E
E2E
E2E
E2E
E2E
Main
Main
Main
Main
Main
Main
circuit
circuit
circuit
circuit
circuit
Connections
XS2F
1
1
2
2
3
3
4
4
XS3F
1
1
2
2
3
3
4
4
XS3F
1
1
2
2
3
3
4
4
XS3F
1
1
2
2
3
3
4
4
XS2F
1
1
2
2
3
3
4
4
XS2F
*
1
1
2
2
3
3
4
4
Brown (+V)
Blue (0 V)
Black (output)
Brown (+V)
White (not connected)
Blue (0 V)
Black (output)
Brown (+V)
White (not connected)
Blue (0 V)
Black (output)
Brown (+V)
White (output)
Blue (0 V)
Black (not connected)
Brown
Blue
Brown
White
Blue (not connected)
Black (not connected)
16
NO
17
DC 2-wire
(Smartclick
connector)
18NC
* Different from Proximity Sensor wire colors.
Refer to Introduction to Sensor I/O Connectors for details.
E2E-X@D1-M1TGJ
E2E-X@D1M1TGJ-U
E2E-X@D2M1TGJ-U
XS5F-D421-@80-A
D: 2-m cable
G: 5-m cable
XS5F-D421-@80-P
D: 2-m cable
G: 5-m cable
XS5F-D421-@80-P
D: 2-m cable
G: 5-m cable
E2E
E2E
E2E
Main
Main
Main
circuit
circuit
circuit
XS5F
1
1
2
2
3
3
4
4
XS5F
1
1
2
2
3
3
4
4
XS5F
1
1
2
2
3
3
4
4
Brown (+)
White (not connected)
Blue (not connected)
Black
(−)
Brown (+)
White (not connected)
Blue (not connected)
Black
(−)
(+)
Brown
White
(−)
Blue (not connected)
Black (not connected)
26
Safety Precautions
Refer to Warranty and Limitations of Liability.
WARNING
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
CAUTION
• Do not short the load. Explosion or burning may
result.
• Do not supply power to the Sensor with no load,
otherwise Sensor may be damaged.
Applicable Models
E2E-CR6@
E2E-CR8@
E2E-X1@
E2E-C1@
Precautions for Correct Use
Do not use this product under ambient conditions that exceed the
ratings.
● Design
Influence of Surrounding Metal
When mounting the Sensor within a metal panel, ensure that the
clearances given in the following table are maintained. Failure to
maintain these distances may cause deterioration in the performance
of the Sensor.
When installing Sensors face-to-face or
side-by-side, ensure that the minimum
distances given in the following table are
maintained.
A
Mutual Interference (Unit: mm)
ModelItemM8M12M18M30
DC 2-Wire Models
E2E-X@D@
AC/DC 2-Wire Models
E2E-X@T1
DC 3-Wire Models
E2E-X@E@/X@F@
AC 2-Wire Models
E2E-X@Y@
Shielded
Unshielded
Shielded
Unshielded
A2030 (20)50 (30)100 (50)
B1520 (12)35 (18)70 (35)
A80120 (60)200 (100)300 (100)
B60100 (50)110 (60)200 (100)
A2030 (20)50 (30)100 (50)
B1520 (12)35 (18)70 (35)
A80120 (60)200 (100)300 (100)
B60100 (50)110 (60)200 (100)
ModelItem3 dia.4 dia.M55.4 dia.
B
DC 3-Wire Models
E2E-X@C/B@
E2E-C@C/B@
Shielded
A20
B15
Note: Values in parentheses apply to Sensors operating at different frequencies.
Loads with Large Surge Currents (E2E-X@T@)
If a load with a large surge current is connected, such as a relay, lamp, or motor, the surge current may cause the load short-circuit protection
circuit to operate, resulting in operating errors.
● Mounting
Tightening Force
Do not tighten the nut with excessive force.
A washer must be used with the nut.
Shielded ModelsUnshielded Models
Part B Part APart B Part A
Note: 1. The allowable tightening strength depends on the distance from the
edge of the head, as shown in the following table. (A is the distance
from the edge of the head. B includes the nut on the head side. If the
edge of the nut is in part A, the tightening torque for part A applies
instead.)
2. The following strengths assume washers are being used.
Model
Dimension
M51 N·m
Shielded9
M8
Unshielded3
M1230 N·m
M1870 N·m
M30180 N·m
Part APart B
TorqueTorque
9 N·m12 N·m
Refer to the following to mount the E2E-CR6, E2E-CR8 and E2E-C1
Unthreaded Cylindrical Models.
E2E-CR6
E2E-CR8, E2E-C1
9 to 21 mm
8 to 21 mm
Dimpled end of
set screw (M3)
(No screws are provided
with the E2E-CR8 or
E2E-C1.)
When using a set screw, tighten it to a torque of 0.2 N·m max.
(E2E-C1: 0.4 N·m max.)
Connecting a DC 2-Wire Proximity Sensor to a PLC (Programmable Controller)
Required Conditions
Connection to a PLC is possible if the specifications of the PLC and the Proximity Sensor satisfy the following
conditions. (The meanings of the symbols are given at the right.)
1. The ON voltage of the PLC and the residual voltage of the Proximity Sensor must satisfy the following.
ON≤ VCC− VR
V
2. The OFF current of the PLC and the leakage current of the Proximity Sensor must satisfy the following.
OFF≥ Ileak
I
(If the OFF current is not listed in the PLC’s input specifications, take it to be 1.3 mA.)
3. The ON current of the PLC and the control output of the Proximity Sensor must satisfy the following.
OUT (min.) ≤ ION≤ IOUT (max.)
I
The ON current of the PLC will vary, however, with the power supply voltage and the input impedance, as
shown in the following equation.
ON = (VCC− VR− VPC)/RIN
I
Example
In this example, the above conditions are checked when the PLC Unit is the C200H-ID212, the Proximity
Sensor is the E2E-X7D1-N, and the power supply voltage is 24 V.
ON (14.4 V) ≤ VCc (20.4 V) − VR (3 V) = 17.4 V:OK
1. V
2. I
OFF (1.3 mA) ≥ Ileak (0.8 mA):OK
ON = [VCC (20.4 V) − VR (3 V) − VPLC (4 V)]/RIN (3 kΩ) = Approx. 4.5 mA
3. I
Therefore, I
Connection is thus possible.
OUT (min.) (3 mA) ≤ ION (4.5 mA):OK
VON:ON voltage of PLC (14.4 V)
ON: ON current of PLC (typically 7 mA)
I
I
OFF: OFF current of PLC (1.3 mA)
IN: Input impedance of PLC (3 kΩ)
R
PC: Internal residual voltage of PLC (4 V)
V
V
R: Output residual voltage of Proximity Sensor
(3 V)
leak: Leakage current of Proximity Sensor
I
(0.8 mA)
OUT Control output of Proximity Sensor (3 to
I
100 mA)
CC: Power supply voltage (PLC: 20.4 to 26.4 V)
V
Values in parentheses apply to the following PLC
model and Proximity Sensor model.
PLC:C200H-ID212
Sensor: E2E-X7D1-N
28
E2E
Dimensions
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
Main Units
Model Number-Dimensions Drawing Number Lookup Table
ModelShieldedModelNo.ModelNo.ModelNo.ModelNo.
Shielded
Pre-wired Models
Unshielded
Shielded
Connector
Models
(M12)
Unshielded
Connector
Models
(M8)
Shielded
UnshieldedE2E-X4MD@-M3G29 E2E-X2ME/F@-M329
Shielded
Pre-wired
Connector
Models
Unshielded
Pre-wired
Connector
Models
(no polarity)
Note 1. Two clamping nuts and one toothed washer are provided with M8 to M30 Models.
2. The model numbers of M8 to M30 Pre-wired Models are laser-marked on the milled section and cable section. This does not apply, however, to models that
*2.4-dia. vinyl-insulated round cable with 3 conductors
(Conductor cross section: 0.08 mm
27
17
Operation indicator (red)
2
, Insulator diameter: 0.7 mm)
*
Diagram 2E2E-CR8B@/CR8C@
4 dia.
*2.9-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section:
2
0.14 mm
, Insulator diameter: 0.9 mm), Standard length: 2 m
Robotics Cable Models:
2.9-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section:
2
0.15 mm
, Insulator diameter: 1.05 mm), Standard length: 2 m
The cable can be extended up to 100 m (separate metal conduit).
25
17.5
Operation indicator (red)
*
Diagram 3E2E-C1B@/C1C@
5.4 dia.
*2.9-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section:
2
, Insulator diameter: 0.9 mm), Standard length: 2 m
0.14 mm
Robotics Cable Models:
2.9-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section:
2
0.15 mm
, Insulator diameter: 1.05 mm), Standard length: 2 m
The cable can be extended up to 100 m (separate metal conduit).
25
17.5
Operation indicator (red)
*
Mounting Hole Dimensions
F
Dimension3 dia.4 dia.5.4 dia.
F (mm)3.3dia. 4.2dia. 5.7dia.
+0.3
0
+0.5
0
+0.5
0
29
E2E
Pre-wired Models
(Shielded)
Mounting Hole Dimensions
Diagram 4E2E-X1B@/X1C@
10 dia.
8
M5 × 0.5
*2.9-dia. vinyl-insulated round cable with 3 conductors (Conductor cross
section: 0.14 mm
Robotics Cable Models:
2.9-dia. vinyl-insulated round cable with 3 conductors (Conductor cross
section: 0.15 mm
The cable can be extended up to 100 m (separate metal conduit).
25
17.5
15
4
Operation indicator (red)
Two clamping nuts
Two toothed washers
2
, Insulator diameter: 0.9 mm), Standard length: 2 m
2
, Insulator diameter: 1.05 mm), Standard length: 2 m
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm
mm), Standard length: 2 m
Robotics Cable Models:
4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm
1.27 mm), Standard length: 2 m
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm
1.27 mm), Standard length: 2 m
Models with Highly Oil-resistant Cables:
4-dia. polyurethane-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm
diameter: 1.3 mm), Standard length: 2 m
The cable can be extended up to 200 m (separate metal conduit).
*2. D1 Models: Operation indicator (red) and setting indicator (green), D2/E/F Models: Operation indicator (red)
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm
mm), Standard length: 2 m
Robotics Cable Models:
4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm
mm), Standard length: 2 m
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm
mm), Standard length: 2 m
The cable can be extended up to 200 m (separate metal conduit).
*2. D1 Models: Operation indicator (red) and setting indicator (green), D2/E/F Models: Operation indicator (red)
7
8
Indicators *2
Two clamping nuts
Toothed washer
*1
+0.5
0
2
, Insulator diameter: 1.3
2
, Insulator diameter: 1.27
2
, Insulator diameter: 1.27
Diagram 7E2E-X1R5Y@
15 dia.
13
M8 × 1
3
36
Toothed
washer
40
Two clamping nuts
7
8
Operation indicator (red)
4-dia. vinyl-insulated round cable with 2 conductors
(Conductor cross section: 0.3 mm
diameter: 1.3 mm), Standard length: 2 m
The cable can be extended up to 200 m (separate
metal conduit).
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm
mm), Standard length: 2 m
Robotics Cable Models:
4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm
mm), Standard length: 2 m
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm
mm), Standard length: 2 m
Models with Highly Oil-resistant Cables:
4-dia. polyurethane-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm
diameter: 1.3 mm), Standard length: 2 m
The cable can be extended (separate metal conduit) up to 200 m for the control output and up to 100 m for the
4-dia. vinyl-insulated round cable with 2
conductors (Conductor cross section: 0.3 mm
Insulator diameter: 1.3 mm), Standard length: 2 m
The cable can be extended up to 200 m (separate
metal conduit).
*
Diagram 12 E2E-X5MY@
21 dia.
17
9 dia.
2
,
74
M12 × 1
43
38
Two clamping nuts
Toothed
washer
10
4-dia. vinyl-insulated round cable with 2
conductors (Conductor cross section: 0.3 mm
Insulator diameter: 1.3 mm), Standard length: 2 m
The cable can be extended up to 200 m
(separate metal conduit).
Pre-wired Models (Shielded)
Mounting Hole Dimensions
DimensionM8M12M18M30
F (mm)8.5dia. 12.5dia. 18.5dia. 30.5dia.
+0.5
0
+0.5
0
F
Diagram 13 E2E-X3T1Pre-wired Models (Unshielded)
21 dia.
17
60
55
4
9
10
9
Operation indicator (red)
+0.5
0
*
2
,
+0.5
0
*1
M12 × 1
Two clamping nuts
*1 4-dia. vinyl-insulated round cable with 2
Toothed
washer
conductors (Conductor cross section: 0.3 mm
Insulator diameter: 1.3 mm), Standard length: 2 m
The cable can be extended up to 200 m (separate
metal conduit).
, Insulator diameter: 1.9 mm), Standard length: 2 m
The cable can be extended (separate metal conduit) up to 200 m for the control output and
up to 100 m for the diagnostic output.
*2. D1/T Models: Operation indicator (red), Setting indicator (green)
D2/E/F/Y Models: Operation indicator (red)
43
38
4
Toothed washer
Two clamping nuts
10
12
Indicators *2
*1
2
,
Diagram 15 E2E-X14MD@/E2E-X10ME@/F@
E2E-X10MY@
29 dia.
24
14.8 dia.
M18× 1
2
2
,
2
,
2
,
*1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm
,
Insulator diameter: 1.9 mm), Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm
Insulator diameter: 1.9 mm), Standard length: 2 m
Robotics Cable Models:
6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm
Insulator diameter: 1.74 mm), Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm
Insulator diameter: 1.74 mm), Standard length: 2 m
The cable can be extended (separate metal conduit) up to 200 m for the control output
*1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm
Insulator diameter: 1.9 mm), Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm
Insulator diameter: 1.9 mm), Standard length: 2 m
Robotics Cable Models:
6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm
Insulator diameter: 1.74 mm), Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm
Insulator diameter: 1.74 mm), Standard length: 2 m
Models with Highly Oil-resistant:
6-dia. polyurethane-insulated round cable with 2 conductors (Conductor cross section:
2
, Insulator diameter: 1.9 mm), Standard length: 2 m
0.5 mm
The cable can be extended (separate metal conduit) up to 200 m for the control output
and up to 100 m for the diagnostic output.
*2. D1/T Models: Operation indicator (red), Setting indicator (green)
D2/E/F/Y Models: Operation indicator (red)
43
5
Toothed washer
48
Two clamping nuts
10
12
Indicators *2
*1
M8 Connector Models
(Shielded)
Diagram 17 E2E-X20MD@/E2E-X18ME@/F
E2E-X18MY@
48
42 dia.
36
26.8 dia.
M30 × 1.5
2
,
*1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm
2
,
2
,
2
,
Insulator diameter: 1.9 mm), Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm
Insulator diameter: 1.9 mm), Standard length: 2 m
Robotics Cable Models:
6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm
Insulator diameter: 1.74 mm), Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm
Insulator diameter: 1.74 mm), Standard length: 2 m
The cable can be extended (separate metal conduit) up to 200 m for the control output
and up to 100 m for the diagnostic output.
*2. D1/T Models: Operation indicator (red), Setting indicator (green)
D2/E/F/Y Models: Operation indicator (red)
*1. No U suffix: 4-dia. Vinyl-insulated round cable
U suffix: 4-dia. Polyurethane insulated round cable,
Standard length: 300 mm
*2. D1 Models: Operation indicator (red), Setting indicator (green)
D2 Models: Operation indicator (red)
*3. The connectors for M1TGJ models are XS5 Smartclick connectors.
*1
*1. No U suffix: 4-dia. Vinyl-insulated round cable
U suffix: 4-dia. Polyurethane insulated round cable,
Standard length: 300 mm
*2. D1 Models: Operation indicator (red), Setting indicator (green)
D2 Models: Operation indicator (red)
*3. The connectors for M1TGJ models are XS5 Smartclick connectors.
*1
*1. No U suffix: 6-dia. Vinyl-insulated round cable
U suffix: 6-dia. Polyurethane insulated round cable,
Standard length: 300 mm
*2. D1 Models: Operation indicator (red), Setting indicator (green)
D2 Models: Operation indicator (red)
*3. The connectors for M1TGJ models are XS5 Smartclick connectors.
+0.5
0
M12 × 1
M12 × 1
M12 × 1
+0.5
0
Pre-wired Connector Models (Unshielded)
Diagram 32 E2E-X8MD1-M1GJ
E2E-X8MD1-M1TGJ
21 dia.
17
M30 × 1.5
Two clamping nuts
Toothed washer
7
9 dia.
M12 × 1
Indicators *2
38
33
10
4
Toothed washer
*1
*1. No U suffix: 6-dia. Vinyl-insulated round cable
U suffix: 6-dia. Polyurethane insulated round cable,
Standard length: 300 mm
*2. D1 Models: Operation indicator (red), Setting indicator (green)
D2 Models: Operation indicator (red)
*3. The connectors for M1TGJ models are XS5 Smartclick connectors.
9
Indicators *2
Two clamping nuts
*1
*1. 4-dia. vinyl-insulated round cable,
Standard length: 300 mm
*2. Operation indicator (red), Setting
indicator (green)
M12 × 1
M12 × 1
34
E2E
4
10
135
M30 × 1.5
43
38
Diagram 34 E2E-X14MD@-M1GJ
E2E-X14MD1-M1TGJ
Diagram 36 E2E-X20MD1-M1GJ
E2E-X20MD1-M1TGJ
29 dia.
24
14.8 dia.
M18 × 1
42 dia.
36
26.8 dia.
Dimensions for Proximity Sensors with Sensor I/O Connectors
Shielded ModelsUnshielded Models
Straight Connectors
L1
L-shape Connectors
Straight Connectors
L1
L-shape Connectors
12
10
Indicators*2
Two clamping nuts
Toothed washer
48
43
10
Two clamping nuts
Toothed washer
*1
*1. 6-dia. vinyl-insulated round cable, Standard
length: 300 mm
*2. D1 Models: Operation indicator (red),
Setting indicator (green)
D2 Models: Operation indicator (red)
12
*1
Indicators*2
*1. 6-dia. vinyl-insulated round cable,
Standard length: 300 mm
*2. Operation indicator (red),
Setting indicator (green)
M12 × 1
M12 × 1
Dimensions with the XS2F Connected (Unit: mm)
Sensor diameter
Dimension
M8Approx. 75Approx. 62
M12*
DCApprox. 80Approx. 67
AC Approx. 85Approx. 72
M18Approx. 85Approx. 72
M30Approx. 90Approx. 77
* The overall length of the Sensor is different between AC and DC
Models for Sensors with diameters of M12. This will change the
dimension when the I/O Connector is connected.
L1L2
L2
L2
Accessories (Order Separately)
Sensor I/O Connectors
Refer to Introduction to Sensor I/O Connectors for details.
Mounting Brackets
Protective Covers
Sputter Protective Covers
Refer to Y92@ for details.
Dimensions with the XS3F Connected (Unit: mm)
Sensor diameter
Dimension
M8Approx. 65Approx. 54
L1L2
35
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2012 All Right Reserved.
2012.4
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.