Omron Y92E-B30, Y92E-B8, Y92E-B18, E2E-X1R5F1, E2E-X2E1 Data Sheet

...
Standard Proximity Sensor
E2E
Your Search for Proximity Sensors Starts with the World-leading Performance and Quality of the E2E
• Standard Sensors for detecting ferrous metals.
• Models with different frequencies are also available to prevent mutual interference.
• Superior environment resistance with standard cable made of oil­resistant PVC and sensing surface made of material that resists cutting oil.
• Useful to help prevent disconnection. Cable protector provided as a standard feature.
Be sure to read Safety Precautions on page 27.
CSM_E2E_DS_E_8_1
*1, *2
*1: No AC/DC 2-wire models or AC 2-wire M8 models are compliant. *2: Attach three ferrite clamps to the cable of the E2E-X3@@ and
E2E-X8MD@. (Refer to information on TDK catalog number ZCAT2035-0930A.)
Features
2-Wire Models
Pre-wired Models with Oil-resistant Reinforced PUR Cables Added
to the Lineup and Easy Differentiation with Orange Head
Oil ResistanceOil Resistance
Oil Resistance
Differentiation from standard models: Orange Head
Lineup includes models with Smartclick pre-wired connectors for fast connection.
Insert all the way.
Oil Resistance (Insulation service life): twice or three times that of oil-resistant vinyl chloride
Click
1/8 turn
Cable FlexibilityCable FlexibilityCable Flexibility
Cable Flexibility: approximately twice that of cinyl chloride cables
XS5 Smartclick connectors used to enable checking connector mating
Jacket: Polyester elastomer
Insulation: Oil-resistant grade PUR (polyurethane)
Cable Flexibility at Cable Flexibility at
Cable Flexibility at Low Temperatures Low Temperatures
Low Temperatures
More Flexibility at 40°C
1
E2E
Lineup includes models with self-diagnostic output to provide notification of failures and unstable detection conditions, such as coil burnout.
Contributes to preventive maintenance to keep the line from stopping.
Reduced wiring, fewer resources, and low power consumption contribute to environmentalism.
Wiring work and amount of copper wire used reduced to two thirds of that required for 3-wire models.
Current consumption drastically reduced to less than 10% (when a DC 2-wire model is compared with a DC 3-wire model).
3-Wire Models
Lineup includes models with small diameter (3 dia., 4 dia., 5.4 dia., M5)
All small-diameter models use sealed construction. Operation is stable even when the Sensor is mounted in a small space or embedded in metal.
Bright indicators enable easily checking the installation condition.
Wide range of ambient operating temperatures: 40°C to 85°C (M8 to M30 models)
Wide range of ambient operating temperatures also for small-diameter models: 25°C to 70°C
Suitable for low-temperature and high-temperature applications, which are troublesome for photoelectric sensors.
Lineup includes models with flexible cable (4-dia. to M30 models)
Reduced risk of disconnection in applications with moving parts.
2
Models Listed by E2E Type
: Standard Models, : Different frequency, @: Self-diagnosis, : Different frequency and self-diagnosis,
---: Not listed
2-Wire Models
E2E
Power
DC
AC
AC/DC
supply
Shielding
Shield-
ed
Un-
shield-
ed
Shield-
ed
Un-
shield-
ed
Shield-
ed
Size and sensing distance
M8
2 m
M12
3 mm
M18
7 mm
M30
10 mm
M8
4 mm
M12
8 mm
M18
14 mm
M30
20 mm
M8
1.5 mm
M12
2 mm
M18
5 mm
M30
10 mm
M8
2 mm
M12
5 mm
M18
10 mm
M30
18 mm
M12
2 mm
M18
5 mm
M30
10 mm
Oil-resistant
reinforced PUR cable
Polarity
Yes
Yes
No
Yes
No
Yes
No
mode
Operation
smartclick
M12 pre-wired
connector models
with 2-m
Pre-wired model
cable
NO ●●● ● ●●●--- ●●
NC --- --- --- NO ●●●●@■● ● ●@ ---
NC --- --- ---
NO --- --- --- --- --- --- --- --- ---
NC --- --- --- --- --- --- --- --- --- --­NO ●●●●@■● ● ●@ ---
NC --- --- ---
NO --- --- --- --- --- --- --- --- ---
NC --- --- --- --- --- --- --- --- --­NO ●●●●@■● ● ●@ ---
NC --- --- --- ---
NO --- --- --- --- --- --- --- --- ---
NC --- --- --- --- --- --- --- --- ---
(cable material: oil-resistant PVC)/Connector models
smartclick
M12 pre-wired
connector models
Standard cable and flexible cable
with standard
Pre-wired model
2-m cable
with flexible
Pre-wired model
2-m cable
with standard
Pre-wired model
pin arrangement)
M12 standard
pre-wired
connector models
5-m cable
M12 connector (IEC
NO --- --- --- ●●●●--- ●●
NC --- --- --- --- --- --- NO --- --- ●●@■● ● ●@ ---
NC --- --- --- --- --- --- ---
Yes
NO --- --- ●●@■● ● ●@ ---
NC --- --- --- --- --- --- NO --- --- ●●@■● ● ●@ ---
NC --- --- --- --- --- --- ---
NO --- --- --- --- --- --- --- --- ---
NC --- --- --- --- --- --- --- --- ---
NO --- --- --- ●▲ --- ●●--- --- ---
NC --- --- --- --- --- --- --- ---
NO --- --- --- ●▲ --- ●●--- --- ---
NC --- --- --- --- --- --- --- ---
NO --- --- --- ●▲ --- ●●--- --- ---
NC --- --- --- --- --- --- --- ---
--­NO --- --- --- --- --- --- --- --- ---
NC --- --- --- --- --- --- --- --- ---
NO --- --- --- ●▲ --- ●●--- --- ---
NC --- --- --- --- --- --- --- ---
NO --- --- --- ●▲ --- --- --- --- ---
NC --- --- --- --- --- --- --- ---
NO --- --- --- ●▲ --- --- --- --- ---
NC --- --- --- --- --- --- --- ---
NO --- --- --- --- --- --- --- --- ---
NC --- --- --- --- --- --- --- --- --- ---
NO --- --- --- --- --- --- --- ---
--­NC --- --- --- --- --- --- --- --- --- ---
NO --- --- --- --- --- --- --- --- ---
NC --- --- --- --- --- --- --- --- --- ---
Page
Ordering
Refer to page 7.
Refer to
Models
with Self­diagnostic Output on
page 8.
Refer to
Models with con­ventional
connector
pin assign-
ments on
page 9.
Refer to page 8.
Refer to
Models with Self-
diagnostic
Output or
Models with con­ventional
connector
pin assign-
ments on
page 9.
Information
M8 connector
pin arrangement)
M12 connector (old
Dimensions refer-
Refer
to page
ence chart
29.
Refer
to page
10.
3
: Standard Models, : Different frequency, ---: Not listed
3-Wire Models
E2E
Power
DC
NPN
DC
PNP
supply
Shielding
Shield-
ed
Un-
shield-
ed
Shield-
ed
Un-
shield-
ed
Size and sensing distance
3 dia.
0.6 mm
4 dia.
0.8 mm
M5
1 mm
5.4 dia. 1 mm
M8
1.5mm
M12
2 mm
M18
5 mm
M30
10 mm
M8
2 mm
M12
5 mm
M18
10 mm
M30
18 mm
3 dia.
0.6 mm
4 dia.
0.8 mm
M5
1 mm
5.4 dia. 1 mm
M8
1.5mm
M12
2 mm
M18
5 mm
M30
10 mm
M8
2 mm
M12
5 mm
M18
10 mm
M30
18 mm
Oil-resistant
reinforced PUR cable
Polarity
Yes
Yes
mode
Operation
smartclick
M12 pre-wired
NO --- --- --- --- --- --- --- ---
NC --- --- --- --- --- --- --- ---
NO --- --- --- ●●●--- --- ---
NC --- --- --- --- --- --- --- ---
NO --- --- --- ●●●--- --- ---
NC --- --- --- --- --- --- --- ---
NO --- --- --- ●●●--- --- ---
NC --- --- --- --- --- --- --- ---
NO --- --- --- ●●●●---
NC --- --- --- --- --- ---
NO --- --- --- ●▲ --- ---
NC --- --- --- --- --- --- ---
NO --- --- --- ●▲ --- ---
NC --- --- --- --- --- --- ---
NO --- --- --- ●▲ --- ---
NC --- --- --- --- --- --- ---
NO --- --- --- ●●--- ---
NC --- --- --- --- --- ---
NO --- --- --- ●▲ --- ---
NC --- --- --- --- --- --- ---
NO --- --- --- ●▲ --- ---
NC --- --- --- --- --- --- ---
NO --- --- --- ●▲ --- ---
NC --- --- --- --- --- --- ---
NO --- --- --- --- --- --- --- ---
NC --- --- --- --- --- --- --- ---
NO --- --- --- ●●--- --- --- ---
NC --- --- --- --- --- --- --- ---
NO --- --- --- ●●--- --- --- ---
NC --- --- --- --- --- --- --- ---
NO --- --- --- --- --- --- --- ---
NC --- --- --- --- --- --- --- ---
NO --- --- --- ●●●●---
NC --- --- --- --- --- ---
NO --- --- --- ●▲ --- ---
NC --- --- --- --- --- --- ---
NO --- --- --- ●▲ --- ---
NC --- --- --- --- --- --- ---
NO --- --- --- ●●--- --- ---
NC --- --- --- --- --- --- ---
NO --- --- --- ●●--- ---
NC --- --- --- --- --- ---
NO --- --- --- ●●--- --- ---
NC --- --- --- --- --- --- ---
NO --- --- --- ●●--- --- ---
NC --- --- --- --- --- --- ---
NO --- --- --- ●●--- --- ---
NC --- --- --- --- --- --- ---
connector models
Pre-wired model
(cable material: oil-resistant PVC)/Connector models
smartclick
M12 pre-wired
with 2-m cable
Standard cable and flexible cable
connector models
Pre-wired model
2-m cable
with standard
Pre-wired model
2-m cable
with flexible
with standard
Pre-wired model
5-m cable
M12 connector (IEC
pin arrangement)
M12 standard pre-
wired
connector models
Page
Ordering
Refer
to page
11.
Refer
to page
12.
Refer
to page
11.
Refer
to page
12.
Information
M8 connector
Dimensions refer-
Refer
to page
29.
ence chart
4
E2E Guide to Selection by Purpose
E2E
Environment
Maintenance
Wide operating
temperature range
Resists the influence of surrounding metal
Reducing stocked
models
Easy replacement
NPN/PNP output
AC/DC
40 to 85°C AC 2-wire: M12 to M30, DC 3-wire: M8 to M30
25 to 70° Models not listed above.
Shielded Models
DC 2-Wire Models E2E-X@D@
AC/DC 2-Wire Models E2E-X@T1
Smartclick Pre-wired Connector Models E2E-X@D@-M1TGJ-(U)
Pre-wired Connector Models E2E-X@D1-M1(G)J-(T)
Connector Models E2E-X@D@-M1(G) E2E-X@E@-M1 E2E-X@Y@-M1
C
Reducing troubles
Note: Refer to Models Not Listed in this Catalog for Long Body Models, Transmission Couplers, and Power Couplers.
Higher oil resistance
Mounting to moving
parts
Robotics cable
Mutual interference
prevention
Miswiring measures
Early discovery
of problems
Reinforced
Standard
Load short-circuit
protection
No polarity
Models with Oil-resistor reinforced PUR cable E2E-X@D@-U
Models with Oil-resistant PVC cable
Robotics Cable Models E2E-X@D1-R E2E-X@E1-R
Models with a Different Frequency (NO Models only) E2E-X@@15
DC 2-Wire Models E2E-X@D@ DC 3-Wire Models E2E-X@E@
DC 2-Wire No-polarity Models E2E-X@D1-M1J-T
Diagnostic Models E2E-X@D1S
5
E2E Model Number Legend
E2E
E2E-
No. Classification Code Meaning Remarks
A Appearance
B Sensing distance
C Shielding
D
E
F Oscillation frequency type
G Self-diagnosis
H Connection method
I Connector specifications
J DC 2-wire polarity
K Cable specifications
L New model N
M Cable length Letter M
Note: The purpose of this model number legend is to provide understanding of the meaning of specifications from the model number.
A BCDEFG H I - J - K - L- M
C Cylindrical (not threaded) X Cylindrical (threaded)
Number Sensing distance (Unit: mm) Example:
R Indication of decimal point
Blank Shielded Models
M Unshielded Models B DC 3-wire PNP open-collector output C DC 3-wire NPN open-collector output
Power supply and output specifications
Form of output switching el­ement
Models are not available for all combinations of code numbers. Ask your OMRON representative if you require a customized model.
D DC 2-wire polarity/no polarity E DC 3-wire NPN collector load built-in output F DC 3-wire PNP collector load built-in output T AC/DC 2-wire Y AC 2-wire 1 Normally open (NO) 2 Normally closed (NC)
Blank Standard frequency
5 Different frequency
Blank No
5Yes
Blank Pre-wired
M1 M12-size metal connector
M3 M8-size metal connector
Blank
G
J
GJ
TJ
TGJ
Blank Polarity
T No polarity
Blank Standard PVC cable (oil resistant)
R Flexible PVC cable (oil resistant) U Polyurethane cable (oil resistant and reinforced)
Connector Models DC 3-wire and AC 2-wire, DC 2-wire with self-diagnosis output, DC 2-wire with old pin arrangement (polarity)
Connector Models DC 2-wire with IEC pin arrangement (polarity)
Pre-wired Connector Models DC 3-wire and AC 2-wire, DC 2-wire with IEC pin arrangement (polarity), DC 3-wire and AC 2-wire, DC 2-wire with self-diagno­sis output, DC 2-wire with old pin arrangement (polarity)
Pre-wired Connector Models DC 2-wire with IEC pin arrangement (polarity)
Pre-wired Smartclick Connector Models DC 2-wire with IEC pin arrangement (no polarity)
Pre-wired Smartclick Connector Models DC 2-wire with IEC pin arrangement (polarity)
New model (Applies only to DC 2-wire pre-wired and shielded models.)
Cable length (Unit: m) (Applicable to Pre-wired Models and Pre­wired Connector Models.)
R6: 0.6 mm 1R5: 1.5 mm
Whether D models have polarity is defined by num­ber J.
Used to prevent mutual in­terference.
This is blank if the cable specification in number K is R or U.
Example:
2M
0.3M
6
Ordering Information
2-Wire Models
Shielded DC 2-wire Models with No Self-diagnostic Output [Refer to Dimensions on page 29.]
E2E
Appear-
ance
M8
M12
M18
M30
*1. Models with different frequencies are also available. The model number is E2E-X @D15 (example: E2E-X3D15-N 2M). *2. Models with a flexible cable are also available. Add "-R" rather than "-N" to the end of the model number (example: E2E-X2D1-R 2M). *3. The standard stock includes models with a cable length of 5 m. Specify the cable length at the end of the model number. (Example: E2E-X3D1-N 5M) *4. Refer to page 24 for details. *5. The residual voltage for models without polarity is 5 V, so use caution concerning the connection load interface conditions (e.g., PLC ON voltage). Refer to page 28. *6. The standard cable length is 300 mm. Cables with a length of 500 mm and 1 m can also be manufactured.
Sensing distance
2 mm
3 mm
7 mm
10 mm
Connection
method
M12 Pre-wired Smart­click Connector Mod­els (0.3m)
Pre-wired Models (2 m)
M12 Connector Mod­els
M8 Connector Models ---
M12 Pre-wired Smart­click Connector Mod­els (0.3m)
Pre-wired Models (2 m)
M12 Connector Mod­els
M12 Standard Pre­wired Connector Mod­els (0.3 m) *6
M12 Pre-wired Smart­click Connector Mod­els (0.3m)
Pre-wired Models (2 m)
M12 Connector Mod­els
M12 Standard Pre­wired Connector Mod­els (0.3 m) *6
M12 Pre-wired Smart­click Connector Mod­els (0.3m)
Pre-wired Models (2 m)
M12 Connector Mod­els
M12 Standard Pre­wired Connector Mod­els (0.3 m) *6
Cable
specifications
PUR (increased oil-resistant)
PVC (oil-resistant) NO 1: +V, 4: 0 V G E2E-X2D1-M1TGJ 0.3M
PUR (increased oil-resistant)
PVC (oil-resistant)
PUR (increased oil-resistant)
PVC (oil-resistant) NO 1: +V, 4: 0 V G E2E-X3D1-M1TGJ 0.3M
PUR (increased oil-resistant)
PVC (oil-resistant)
PVC (oil-resistant)
PUR (increased oil-resistant)
PVC (oil-resistant) NO 1: +V, 4: 0 V G E2E-X7D1-M1TGJ 0.3M
PUR (increased oil-resistant)
PVC (oil-resistant)
PVC (oil-resistant)
PUR (increased oil-resistant)
PVC (oil-resistant) NO 1: +V, 4: 0 V G E2E-X10D1-M1TGJ 0.3M
PUR (increased oil-resistant)
PVC (oil-resistant)
PVC (oil-resistant)
---
---
---
---
Polar-
ity
Yes
Yes
Yes
No *5
Yes
Yes
No *5
Yes
Yes
No *5
Opera-
tion
mode
NO 1: +V, 4: 0 V
NC 1: +V, 2: 0 V E2E-X2D2-M1TGJ-U 0.3M
NO
NC E2E-X2D2-U 2M
NO E2E-X2D1-N 2M *2*3
NC E2E-X2D2-N 2M *3
NO 1: +V, 4: 0 V A E2E-X2D1-M1G
NC 1: +V, 2: 0 V D E2E-X2D2-M1G
NO 1: +V, 4: 0 V
NC 1: +V, 2: 0 V E2E-X2D2-M3G
NO 1: +V, 4: 0 V
NC 1: +V, 2: 0 V E2E-X3D2-M1TGJ-U 0.3M
NO
NC E2E-X3D2-U 2M
NO E2E-X3D1-N 2M *1*2*3
NC E2E-X3D2-N 2M *3
NO 1: +V, 4: 0 V A E2E-X3D1-M1G *1
NC 1: +V, 2: 0 V D E2E-X3D2-M1G
NO 1: +V, 4: 0 V A E2E-X3D1-M1GJ 0.3M
NC 1: +V, 2: 0 V D E2E-X3D2-M1GJ 0.3M
NO (3, 4): (+V, 0 V) C E2E-X3D1-M1J-T 0.3M
NC (1, 2): (+V, 0 V) D
NO 1: +V, 4: 0 V
NC 1: +V, 2: 0 V E2E-X7D2-M1TGJ-U 0.3M
NO
NC E2E-X7D2-U 2M
NO E2E-X7D1-N 2M *1*2*3
NC E2E-X7D2-N 2M *3
NO 1: +V, 4: 0 V A E2E-X7D1-M1G *1
NC 1: +V, 2: 0 V D E2E-X7D2-M1G
NO 1: +V, 4: 0 V A E2E-X7D1-M1GJ 0.3M
NC 1: +V, 2: 0 V D E2E-X7D2-M1GJ 0.3M
NO (3, 4): (+V, 0 V) C E2E-X7D1-M1J-T 0.3M
NC (1, 2): (+V, 0 V) D E2E-X7D2-M1J-T 0.3M
NO 1: +V, 4: 0 V
NC 1: +V, 2: 0 V E2E-X10D2-M1TGJ-U 0.3M
NO
NC E2E-X10D2-U 2M
NO E2E-X10D1-N 2M *1*2*3
NC E2E-X10D2-N 2M
NO 1: +V, 4: 0 V A E2E-X10D1-M1G *1
NC 1: +V, 2: 0 V D E2E-X10D2-M1G
NO 1: +V, 4: 0 V A E2E-X10D1-M1GJ 0.3M
NC 1: +V, 2: 0 V D E2E-X10D2-M1GJ 0.3M
NO (3, 4): (+V, 0 V) C E2E-X10D1-M1J-T 0.3M
NC (1, 2): (+V, 0 V) D E2E-X10D2-M1J-T 0.3M
Pin
arrangement
--- ---
--- ---
--- ---
--- ---
Applicable
connector
code *4
H
I
H
H
H
Model
E2E-X2D1-M1TGJ-U 0.3M
E2E-X2D1-U 2M
E2E-X2D1-M3G
E2E-X3D1-M1TGJ-U 0.3M
E2E-X3D1-U 2M
---
E2E-X7D1-M1TGJ-U 0.3M
E2E-X7D1-U 2M
E2E-X10D1-M1TGJ-U 0.3M
E2E-X10D1-U 2M
7
2-Wire Models
Unshielded DC 2-Wire Models with No Self-diagnosis Output [Refer to Dimensions on page 29.]
E2E
Appear-
ance
M8
M12
M18
M30
*1. Models with different frequencies are also available. The model number is E2E-X @D15 (example: E2E-X8MD15 2M). *2. Models with a flexible cable are also available. Add -R to the end of the model number. (example: E2E-X4MD1-R 2M). *3. The standard stock includes models with a cable length of 5 m. Specify the cable length at the end of the model number. (Example: E2E-X4MD1 5M) *4. Refer to page 24 for details.
Sensing distance
4 mm
8 mm
14 mm
20 mm
Connection
method
Pre-wired Models (2 m) PVC (oil-resistant)
M12 Connector Models ---
M8 Connector Models ---
12M Pre-wired Smart­click Connector Models (0.3m)
Pre-wired Models (2 m) PVC (oil-resistant)
M12 Connector Models ---
M12 Standard Pre­wired Connector Mod­els (0.3 m)
12M Pre-wired Smart­click Connector Models (0.3m)
Pre-wired Models (2 m) PVC (oil-resistant)
M12 Connector Models ---
M12 Standard Pre­wired Connector Mod­els (0.3 m)
12M Pre-wired Smart­click Connector Models (0.3m)
Pre-wired Models (2 m) PVC (oil-resistant)
M12 Connector Models ---
M12 Standard Pre­wired Connector Mod­els (0.3 m)
Cable
specifications
PVC (oil-resistant) NO 1: +V, 4: 0 V G E2E-X8MD1-M1TGJ 0.3M
PVC (oil-resistant)
PVC (oil-resistant) NO 1: +V, 4: 0 V G E2E-X14MD1-M1TGJ 0.3M
PVC (oil-resistant)
PVC (oil-resistant) NO 1: +V, 4: 0 V G E2E-X20MD1-M1TGJ 0.3M
PVC (oil-resistant)
Polar-
ity
Yes
Opera-
tion
mode
NO
NC E2E-X4MD2 2M
NO 1: +V, 4: 0 V A E2E-X4MD1 2M
NC 1: +V, 2: 0 V D E2E-X4MD2-M1G
NO 1: +V, 4: 0 V
NC 1: +V, 2: 0 V E2E-X4MD2-M3G
NO
NC E2E-X8MD2 2M
NO 1: +V, 4: 0 V A E2E-X8MD1-M1G *1
NC 1: +V, 2: 0 V D E2E-X8MD2-M1G
NO 1: +V, 4: 0 V A E2E-X8MD1-M1GJ 0.3M
NC 1: +V, 2: 0 V D
NO
NC E2E-X14MD2 2M
NO 1: +V, 4: 0 V A E2E-X14MD1-M1G *1
NC 1: +V, 2: 0 V D E2E-X14MD2-M1G
NO 1: +V, 4: 0 V A E2E-X14MD1-M1GJ 0.3M
NC 1: +V, 2: 0 V D E2E-X14MD2-M1GJ 0.3M
NO
NC E2E-X20MD2 2M
NO 1: +V, 4: 0 V A E2E-X20MD1-M1G *1
NC 1: +V, 2: 0 V D E2E-X20MD2-M1G
NO 1: +V, 4: 0 V A E2E-X20MD1-M1GJ 0.3M
NC 1: +V, 2: 0 V D
Pin
arrangement
--- ---
--- ---
--- ---
--- ---
Applicable
connector
code *4
I
Model
E2E-X4MD1 2M *2*3
E2E-X4MD1-M3G
E2E-X8MD1 2M *1*2*3
E2E-X14MD1 2M *1*2*3
E2E-X20MD1 2M *1*2*3
---
---
Shielded DC 2-Wire Models with Self-diagnosis Output [Refer to Dimensions on page 29.]
Appear-
ance
M12
M18
M30
*1. Models with different frequencies are also available. The model number is E2E-X @D15S (example: E2E-X3D15S 2M). *2. Refer to page 24 for details.
Sensing distance
3 mm
7 mm
10 mm
Connection
method
Pre-wired Models (2 m)
M12 Connector Models
Pre-wired Models (2 m)
M12 Connector Models
Pre-wired Models (2 m)
M12 Connector Models
Cable
specifications
PVC (oil-resistant)
---
PVC (oil-resistant) --- --- E2E-X7D1S 2M *1
---
PVC (oil-resistant) --- --- E2E-X10D1S 2M *1
---
Polar-
ity
Yes
Opera-
tion
mode
2: +V and diagnostic output 3: 0 V 4: +V and control output
NO
2: +V and diagnostic output 3: 0 V 4: +V and control output
2: +V and diagnostic output 3: 0 V 4: +V and control output
Pin
arrangement
--- --- E2E-X3D1S 2M *1
Applicable
connector
code *2
D E2E-X3D1S-M1
D E2E-X7D1S-M1
D E2E-X10D1S-M1
Model
8
2-Wire Models
Unshielded DC 2-Wire Models with Self-diagnosis Output [Refer to Dimensions on page 29.]
E2E
Appear-
ance
M12
M18
M30
*1. Models with different frequencies are also available. The model number is E2E-X @MD15S (example: E2E-X8MD15S 2M). *2. Refer to page 24 for details.
Sensing distance
8 mm
14 mm
20 mm
Connection
method
Pre-wired Mod­els (2 m)
M12 Connector Models
Pre-wired Mod­els (2 m)
M12 Connector Models
Pre-wired Mod­els (2 m)
M12 Connector Models
Cable
specifications
PVC (oil-resistant)
---
PVC (oil-resistant) --- --- E2E-X14MD1S 2M *
---
PVC (oil-resistant) --- --- E2E-X20MD1S 2M *
---
Polar-
ity
Yes
Opera-
tion
mode
2: +V and diagnostic output 3: 0 V 4: +V and control output
NO
2: +V and diagnostic output 3: 0 V 4: +V and control output
2: +V and diagnostic output 3: 0 V 4: +V and control output
Pin
arrangement
--- --- E2E-X8MD1S 2M *
Connector Pin Assignments of DC 2-Wire Models
The connector pin assignments of each New E2E DC 2-Wire Model conform to IEC 947-5-2 Table III. (Only DC 2-Wire Models have been changed in comparison to the previous models.)
The following models with conventional connector pin assignments are available as well. (Only NO Models can be used.) The cable at the right should also be used if the XW3A-P@45-G11 Connector Junction Box is already being used.
Cable length Model
500 mm XS2W-D421-BY1
Internal Wiring
(Proximity Sensor end) (Wired end)
1 4
Models with conventional connector pin assignments are available as well.
Appearance
NO Applicable connector code * NC Applicable connector code *
Model
M8 E2E-X2D1-M1 C E2E-X2D2-M1 D
Shielded
M12 E2E-X3D1-M1 C E2E-X3D2-M1 D
M18 E2E-X7D1-M1 C E2E-X7D2-M1 D
M30 E2E-X10D1-M1 C E2E-X10D2-M1 D
M8 E2E-X4MD1-M1 C E2E-X4MD2-M1 D
Unshielded
M12 E2E-X8MD1-M1 C E2E-X8MD2-M1 D
M18 E2E-X14MD1-M1 C E2E-X14MD2-M1 D
M30 E2E-X20MD1-M1 C E2E-X20MD2-M1 D
Note: Refer to page 24 for details.
Applicable
connector
code *2
D E2E-X8MD1S-M1
D E2E-X14MD1S-M1
D E2E-X20MD1S-M1
Model
4 3
9
2-Wire Models
AC 2-Wire Models Shielded Models [Refer to Dimensions on page 29.]
E2E
Appear-
ance
M8
M12
M18
M30
*1. Models with different frequencies are also available. The model number is E2E-X @Y@5 (example: E2E-X5Y15 2M). *2. The standard stock includes models with a cable length of 5 m. Specify the cable length at the end of the model number. (Example: E2E-X2Y1 5M) *3. Refer to page 24 for details.
Sensing distance
1.5 mm
2 mm
5 mm
10 mm
Connection
method
Pre-wired Models (2 m)
Pre-wired Models (2 m)
M12 Connector Models
Pre-wired Models (2 m)
M12 Connector Models
Pre-wired Models (2 m)
M12 Connector Models
Cable
specifications
PVC (oil-resistant)
PVC (oil-resistant)
---
PVC (oil-resistant)
---
PVC (oil-resistant)
---
Operation
mode
NO
NC E2E-X1R5Y2 2M
NO
NC E2E-X2Y2 2M
NO (3, 4): (AC, AC) E E2E-X2Y1-M1
NC (1, 2): (AC, AC) F E2E-X2Y2-M1
NO
NC E2E-X5Y2 2M
NO (3, 4): (AC, AC) E E2E-X5Y1-M1
NC (1, 2): (AC, AC) F E2E-X5Y2-M1
NO
NC E2E-X10Y2 2M
NO (3, 4): (AC, AC) E E2E-X10Y1-M1
NC (1, 2): (AC, AC) F E2E-X10Y2-M1
Pin
arrangement
--- ---
--- ---
--- ---
--- ---
Applicable con-
nector code *3
E2E-X1R5Y1 2M
E2E-X2Y1 2M *1*2
E2E-X5Y1 2M *1*2
E2E-X10Y1 2M *1*2
Model
Unshielded Models
Appear-
ance
M8
M12
M18
M30
*1. Models with different frequencies are also available. The model number is E2E-X @MY@5 (example: E2E-X5MY15 2M). *2. The standard stock includes models with a cable length of 5 m. Specify the cable length at the end of the model number. (Example: E2E-X5MY1 5M) *3. Refer to page 24 for details.
Sensing distance
2 mm
5 mm
10 mm
18 mm
Connection
method
Pre-wired Models (2 m)
Pre-wired Models (2 m)
M12 Connector Models
Pre-wired Models (2 m)
M12 Connector Models
Pre-wired Models (2 m)
M12 Connector Models
Cable
specifications
PVC (oil-resistant)
PVC (oil-resistant)
---
PVC (oil-resistant)
---
PVC (oil-resistant)
---
Operation
mode
NO
NC E2E-X2MY2 2M
NO
NC E2E-X5MY2 2M
NO (3, 4): (AC, AC) E E2E-X5MY1 2M
NC (1, 2): (AC, AC) F E2E-X5MY2-M1
NO
NC E2E-X10MY2 2M
NO (3, 4): (AC, AC) E E2E-X10MY1-M1
NC (1, 2): (AC, AC) F E2E-X10MY2-M1
NO
NC E2E-X18MY2 2M
NO (3, 4): (AC, AC) E E2E-X18MY1-M1
NC (1, 2): (AC, AC) F E2E-X18MY2-M1
Pin
arrangement
--- ---
--- ---
--- ---
--- ---
Applicable con-
nector code *3
E2E-X2MY1 2M
E2E-X5MY1 2M *1*2
E2E-X10MY1 2M *1
E2E-X18MY1 2M *1
Model
AC 2-Wire Models Shielded Models [Refer to Dimensions on page 29.]
(There are no unshielded models.)
Appear-
ance
M12
M18
M30
Note: Not compliant with CE. * The standard stock includes models with a cable length of 5 m. Specify the cable length at the end of the model number. (Example: E2E-X7T1 5M)
Sensing distance
3 mm
7 mm
10 mm
Connection
method
Pre-wired Models (2 m)
Pre-wired Models (2 m)
Pre-wired Models (2 m)
Cable
specifications
PVC (oil-resis­tant)
PVC (oil-resis­tant)
PVC (oil-resis­tant)
Operation
mode
NO
Pin
arrangement
--- --- E2E-X3T1 2M
--- --- E2E-X7T1 2M *
--- --- E2E-X10T1 2M
Applicable con-
nector code *3
Model
10
3-Wire Models
Shielded DC 3-Wire Models [Refer to Dimensions on page 29.]
E2E
Appear-
ance
3 dia.
4 dia.
M5
5.4 dia.
M8
M12
M18
M30
*1. The standard stock includes models with a cable length of 5 m. Specify the cable length at the end of the model number. (Example: E2E-X2E1 5M) *2. Models with a flexible cable are also available. Add -R to the end of the model number. (example: E2E-X5E1-R 2M). *3. Models with different frequencies are also available. The model number is E2E-X@@@5 (example: E2E-X5E15 2M). *4. Refer to page 24 for details.
Sensing distance
0.6 mm
0.8 mm
1 mm
1 mm
1.5 mm
2 mm
5 mm
10 mm
Connection
method
Pre-wired Models (2 m)
Pre-wired Models (2 m)
Pre-wired Models (2 m)
Pre-wired Models (2 m)
Pre-wired Models (2 m)
M12 Connector Models
M8 Connector Models
Pre-wired Models (2 m)
M12 Connector Models
Pre-wired Models (2 m)
M12 Connector Models
Pre-wired Models (2 m)
M12 Connector Models
Cable
specifica-
tions
PVC (oil-re­sistant)
PVC (oil-re­sistant)
PVC (oil-re­sistant)
PVC (oil-re­sistant)
PVC (oil-re­sistant)
PVC (oil-re­sistant)
PVC (oil-re­sistant)
PVC (oil-re­sistant)
PVC (oil-re­sistant)
Opera-
tion
mode
NO
NC E2E-CR6C2 2M E2E-CR6B2 2M
NO
NC E2E-CR8C2 2M E2E-CR8B2 2M
NO
NC E2E-X1C2 2M E2E-X1B2 2M
NO
NC E2E-C1C2 2M E2E-C1B2 2M
NO
NC E2E-X1R5E2 2M E2E-X1R5F2 2M
---
---
---
---
---
NO
NC
NO
NC
NO
NC E2E-X2E2 2M E2E-X2F2 2M
NO
NC
NO
NC E2E-X5E2 2M E2E-X5F2 2M
NO
NC
NO
NC E2E-X10E2 2M E2E-X10F2 2M
NO
NC
Pin
arrangement
--- ---
--- ---
--- ---
--- ---
--- ---
1: +V, 3: 0 V, 4: Control output
1: +V, 3: 0 V, 2: Control output
1: +V, 3: 0 V, 4: Control output
1: +V, 3: 0 V, 2: Control output
--- ---
1: +V, 3: 0 V, 4: Control output
1: +V, 3: 0 V, 2: Control output
--- ---
1: +V, 3: 0 V, 4: Control output
1: +V, 3: 0 V, 2: Control output
--- ---
1: +V, 3: 0 V, 4: Control output
1: +V, 3: 0 V, 2: Control output
Appli-
cable connec­tor code
*5
B
D E2E-X1R5E2-M1 E2E-X1R5F2-M1
I
B
D E2E-X2E2-M1 E2E-X2F2-M1
B
D E2E-X5E2-M1 E2E-X5F2-M1
B
D E2E-X10E2-M1 E2E-X10F2-M1
NPN output PNP output
E2E-CR6C1 2M E2E-CR6B1 2M
E2E-CR8C1 2M *1*2 E2E-CR8B1 2M *2
E2E-X1C1 2M *1*2 E2E-X1B1 2M *2
E2E-C1C1 2M *1*2 E2E-C1B1 2M
E2E-X1R5E1 2M *1*2 E2E-X1R5F1 2M *1*2
E2E-X1R5E1-M1 E2E-X1R5F1-M1
E2E-X1R5E1-M3 E2E-X1R5F1-M3
E2E-X1R5E2-M3 E2E-X1R5F2-M3
E2E-X2E1 2M *1*2*3 E2E-X2F1 2M *1*2*3
E2E-X2E1-M1 E2E-X2F1-M1
E2E-X5E1 2M *1*2*3 E2E-X5F1 2M *1*2*3
E2E-X5E1-M1 E2E-X5F1-M1
E2E-X10E1 2M *1*2*3 E2E-X10F1 2M *2
E2E-X10E1-M1 E2E-X10F1-M1
Model
11
Loading...