3E2E-@Y/E2F-@Y
Metal Housing (E2E)
Size M8 M12 M18 M30
Type Shielded
Unshielded
Shielded
Unshielded
Shielded
Unshielded
Shielded
Unshielded
Item
E2E-X1R5Y@
E2E-X2MY@ E2E-X2Y@ E2E-X5MY@ E2E-X5Y@
E2E-X10MY@
E2E-X10Y@
E2E-X18MY@
Sensing distance 1.5 mm ±10% 2 mm ±10% 2 mm ±10% 5 mm ±10% 5 mm ±10% 10 mm ±10% 10 mm ±10% 18 mm ±10%
Set distance 0 to 1.2 mm 0 to 1.6 mm 0 to 1.6 mm 0 to 4.0 mm 0 to 4.0 mm 0 to 8.0 mm 0 to 8.0 mm 0 to 14.0 mm
Differential travel 10% max. of sensing distance
Sensing object Ferrous metal (The sensing distance decreases with non-ferrous metal, refer to Engineering Data.)
Standard sensing 
object
Iron, 8 x 8 x 
1mm
Iron,12 x 12 
x 1 mm
Iron, 12 x 12 
x 1 mm
Iron, 15 x 15 
x 1 mm
Iron, 18 x 18 
x 1 mm
Iron, 30 x 30 
x 1 mm
Iron, 30 x 30 
x 1 mm
Iron, 54 x 54 
x 1 mm
Response speed 25 Hz
Power supply voltage 
(operating voltage 
range) 
*1
*1. When supplying 24 VAC to any of the above models, make sure that the operating ambient temperature range is over –25 °C.
24 to 240 VAC, 50/60 Hz (20 to 264 VAC)
Leakage current 1.7 mA max.
Control 
output
Load 
current 
*2
*2. When using an M18- or M30-sized E2E within an ambient temperature of 70 °C to 85 °C, make sure that the E2E has a control output of 5 to 200 mA max.
5 to 100 mA 5 to 200 mA 5 to 300 mA
Residual 
voltage
Refer to Engineering Data.
Indicator Operation indicator (red LED)
Operation mode 
(with sensing object 
approaching)
Y1 Models: NO 
Y2 Models: NC 
For details, refer to Timing Charts.
Protection circuit Surge suppressor
Ambient temperature 
*1 *2
Operating/Storage: 
–25 °C to 70 °C (with no 
icing or condensation)
Operating/Storage: –40 °C to 85 °C (with no icing or condensation)
Ambient humidity Operating/Storage: 35% to 95% (with no condensation)
Temperature 
influence
±10% max. of sensing 
distance at 23 °C in the 
temperature range of 
–25 °C to 70 °C
±15% max. of sensing distance at 23 °C in the temperature range of –40 °C to 85 °C 
±10% max. of sensing distance at 23 °C in the temperature range of –25 °C to 70 °C
Voltage influence ±1% max. of sensing distance in the rated voltage range ±15%
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 4,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case (2,000 VAC for M8 Models)
Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
500 m/s
2
 10 times each in X, 
Y, and Z directions
1,000 m/s2 10 times each in X, Y, and Z directions
Degree of protection IEC 60529 IP67 (Pre-wired models: JEM standard IP67g (waterproof, oil-proof))
Connection method Pre-wired models (standard length 2 m), connector models
Weight 
(packed 
state)
Pre-wired 
models
Approx. 60 g Approx. 70 g Approx. 130 g Approx. 175 g
Connector 
models
Approx. 15 g Approx. 25 g Approx. 40 g Approx. 90 g
Material Case Stainless steel (SUS303) Brass-nickel plated
Sensing 
surface
PBT (polybutylene terephthalate)
Clamping 
nuts
Brass-nickel plated
Toothed 
washer
Iron-zinc plated
Accessories Instruction manual