Omron E2F-X5Y1, E2F-X10Y1, E2F-X1R5Y2, E2F-X2Y2, E2F-X5Y2 Datasheet

...
E2E-@Y/E2F-@Y 1
Cylindrical Inductive Sensor for AC Power Supply
E2E-@Y/E2F-@Y
• 24 to 240 VAC power supply voltage
• brass or plastic housing (M8 in SUS housing)
Ordering Information
AC 2-wire/Pre-wired Models
Metal Housing
AC 2-wire/Pre-wired Models
AC 2-wire/Connector Models
Size Sensing
distance
Model
Operating status
NO NC
Shielded M8 1.5 mm
E2F-X1R5Y1
*1
*1. A different frequency type is available (E2F-X@@5; e.g. E2F-X5E15)
E2F-X1R5Y2
*1
M12 2 mm
E2F-X1Y1
*1
E2F-X2Y2
*1
M18 5 mm
E2F-X5Y1
*1*2
E2F-X5Y2
*1*2
M30 10 mm
E2F-X10Y1
*1*2
E2F-X10Y2
*1*2
*2. A short-circuit protection type is available (E2F-X@Y@-53;
e.g. E2F-X5Y1-53) Power Supply Voltage: 100 to 120 VAC
Size Sensing
distance
Operation
mode
Model
Shielded M8 1.5 mm NO E2E-X1R5Y1
NC E2E-X1R5Y2
M12 2 mm NO
E2E-X2Y1
*1*2
*1. Models with a different frequency are also available. These models are
E2E-X@Y@5 (e.g., E2E-X5Y15).
*2. Cables with a length of 5 m are also available. Specify the cable length at
the end of the model number (e.g., E2E-X2Y1 5M).
NC E2E-X2Y2
M18 5 mm NO
E2E-X5Y1
*1*2
NC E2E-X5Y2
M30 10 mm NO
E2E-X10Y1
*1*2
NC E2E-X10Y2
Un­shielded
M8 2 mm NO E2E-X2MY1
NC E2E-X2MY2
M12 5 mm NO
E2E-X5MY1
*1*2
NC E2E-X5MY2
M18 10 mm NO
E2E-X10MY1
*1
NC E2E-X10MY2
M30 18 mm NO
E2E-X18MY1
*1
NC E2E-X18MY2
Size Sensing
distance
Operation
mode
Model
Shielded M12 2 mm NO E2E-X2Y1-M1
NC E2E-X2Y2-M1
M18 5 mm NO E2E-X5Y1-M1
NC E2E-X5Y2-M1
M30 10 mm NO E2E-X10Y1-M1
NC E2E-X10Y2-M1
Un­shielded
M12 5 mm NO E2E-X5MY1-M1
NC E2E-X5MY2-M1
M18 10 mm NO E2E-X10MY1-M1
NC E2E-X10MY2-M1
M30 18 mm NO E2E-X18MY1-M1
NC E2E-X18MY2-M1
2 Cylindrical Inductive Sensor for AC Power Supply
Specifications
Plastic Housing (E2F)
Model
E2F-X1R5Y@ E2F-X2Y@ E2F-X5Y@ E2F-X10Y@
Sensing distance 1.5 mm ±10% 2 mm ±10% 5 mm ±10% 10 mm ±10%
Setting distance 0 to 1.2 mm 0 to 1.6 mm 0 to 4 mm 0 to 8 mm
Differential distance 10% max
Sensing object Ferrous metal (Sensitivity lowers with non-ferrous metals)
Standard sensing object Iron, 8 x 8 x 1 mm Iron, 12 x 12 x 1 mm Iron, 18 x 18 x 1 mm Iron, 30 x 30 x 1 mm
Response frequency
*1
*1. The response frequencies are average values measured on condition that the distance between each sensing object is twice as large as the size of the sensing
object and the sensing distance set is half of the maximum sensing distance.
25 Hz
Power supply (Operating voltage range)
24 to 240 VAC (20 to 264 VAC)
Leakage current 1.7 mA at 200 VAC
Control output
Switching capacity
5 to 100 mA 5 to 300 mA
Residual voltage
Refer to the Specifications
Indicator lamp Operation indicator (red LED)
Operation status (with sensing object approaching)
Y1 Models: ON Y2 Models: NC
Protection circuit
None
*2
*2. Short circuit protection types are available.
Ambient temperature Operating/Storage: –25 °C to 70 °C (with no icing or condensation)
Ambient humidity Operating/Storage: 35% to 95% RH
Temperature influence A maximim fluctuation of ±10% max. of sensing distance at 23 °C in the temperature range of –25 °C to 70 °C
Voltage influence ±1% max. of sensing distance within a range of ±10% of rated power supply voltage
Insulation resistance 50 M min. (at 500 VDC) between current carry parts and case
Vibration resistance 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
Destruction: 1,000 m/s
2
for 10 times each in X, Y, and Z directions
Protective structure
IEC IP68
*3
*3. OMRON test method
Conditions: Less than 10 m natural state under water (1) It is not flooded underwater with two atmospheric pressure for 1 hour. (2) A heat shock cycle (it is 1 hour, respectively to 0 °C cold water and 70 °C warm water) is repeated 20 times, and the performance of detection distance and insulation resistance is checked.
Connection method Pre-wired models (standard length 2 m)
Weight (Packed state) Approx. 40 g Approx. 50 g Approx. 130 g Approx. 170 g
Material Case Polyarylate
Sensing surface
Clamping nut
Polyarylate resin
Accessories Instruction manual
3E2E-@Y/E2F-@Y
Metal Housing (E2E)
Size M8 M12 M18 M30
Type Shielded
Unshielded
Shielded
Unshielded
Shielded
Unshielded
Shielded
Unshielded
Item
E2E-X1R5Y@
E2E-X2MY@ E2E-X2Y@ E2E-X5MY@ E2E-X5Y@
E2E-X10MY@
E2E-X10Y@
E2E-X18MY@
Sensing distance 1.5 mm ±10% 2 mm ±10% 2 mm ±10% 5 mm ±10% 5 mm ±10% 10 mm ±10% 10 mm ±10% 18 mm ±10%
Set distance 0 to 1.2 mm 0 to 1.6 mm 0 to 1.6 mm 0 to 4.0 mm 0 to 4.0 mm 0 to 8.0 mm 0 to 8.0 mm 0 to 14.0 mm
Differential travel 10% max. of sensing distance
Sensing object Ferrous metal (The sensing distance decreases with non-ferrous metal, refer to Engineering Data.)
Standard sensing object
Iron, 8 x 8 x 1mm
Iron,12 x 12 x 1 mm
Iron, 12 x 12 x 1 mm
Iron, 15 x 15 x 1 mm
Iron, 18 x 18 x 1 mm
Iron, 30 x 30 x 1 mm
Iron, 30 x 30 x 1 mm
Iron, 54 x 54 x 1 mm
Response speed 25 Hz
Power supply voltage (operating voltage range)
*1
*1. When supplying 24 VAC to any of the above models, make sure that the operating ambient temperature range is over –25 °C.
24 to 240 VAC, 50/60 Hz (20 to 264 VAC)
Leakage current 1.7 mA max.
Control output
Load current
*2
*2. When using an M18- or M30-sized E2E within an ambient temperature of 70 °C to 85 °C, make sure that the E2E has a control output of 5 to 200 mA max.
5 to 100 mA 5 to 200 mA 5 to 300 mA
Residual voltage
Refer to Engineering Data.
Indicator Operation indicator (red LED)
Operation mode (with sensing object approaching)
Y1 Models: NO Y2 Models: NC For details, refer to Timing Charts.
Protection circuit Surge suppressor
Ambient temperature
*1 *2
Operating/Storage: –25 °C to 70 °C (with no icing or condensation)
Operating/Storage: –40 °C to 85 °C (with no icing or condensation)
Ambient humidity Operating/Storage: 35% to 95% (with no condensation)
Temperature influence
±10% max. of sensing distance at 23 °C in the temperature range of –25 °C to 70 °C
±15% max. of sensing distance at 23 °C in the temperature range of –40 °C to 85 °C ±10% max. of sensing distance at 23 °C in the temperature range of –25 °C to 70 °C
Voltage influence ±1% max. of sensing distance in the rated voltage range ±15%
Insulation resistance 50 M min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 4,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case (2,000 VAC for M8 Models)
Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
500 m/s
2
10 times each in X,
Y, and Z directions
1,000 m/s2 10 times each in X, Y, and Z directions
Degree of protection IEC 60529 IP67 (Pre-wired models: JEM standard IP67g (waterproof, oil-proof))
Connection method Pre-wired models (standard length 2 m), connector models
Weight (packed state)
Pre-wired models
Approx. 60 g Approx. 70 g Approx. 130 g Approx. 175 g
Connector models
Approx. 15 g Approx. 25 g Approx. 40 g Approx. 90 g
Material Case Stainless steel (SUS303) Brass-nickel plated
Sensing surface
PBT (polybutylene terephthalate)
Clamping nuts
Brass-nickel plated
Toothed washer
Iron-zinc plated
Accessories Instruction manual
4 Cylindrical Inductive Sensor for AC Power Supply
Engineering Data
Output Circuit and Timing Charts
Pin Arrangement
E2E-X@Y@-M1 AC 2-wire Models
Output Operating
Status
Model Timing chart Output circuit
AC 2­wire Models
NO E2F-X1R5Y1
E2F-X2Y1 E2F-X5Y1 E2F-X10Y1 E2E-@Y1
NC E2F-X1R5Y2
E2F-X2Y2 E2F-X5Y2 E2F-X10Y2 E2E-@Y2
Operation mode Applicable models Pin arrangement
NO E2E-X@Y1-M1
NC E2E-X@Y2-M1
Ye s
No
Operates Releases
ON
OFF
Sensing object
Load
Detection indicator
Main circuit
Load
Brown
Blue
Ye s
No
Operates Releases
ON
OFF
Sensing object
Load
Detection indicator
Note: Terminals 1 and 2 are not used.
Load
Load
Note: Terminals 3 and 4 are not used.
Load
Load
5E2E-@Y/E2F-@Y
E2E
Operating Range (Typical)
Leakage Current (Typical)
E2E-X@Y@ E2F-X@Y@
E2E-X@MY@
12
10
8
6
4
2
0
15 10 5 0 5 10 15 Distance Y (mm)
E2E-X10
E2E
-X1R5
E2E-X5
E2E-X2
Sensing distance X (mm)
X
Y
30
25
20
15
10
5
0
30 20 10 0 10 20 30 Distance Y (mm)
E2E-X18M
E2E-X10M
E2E-X5M
E2E-X2M
Sensing distance X (mm)
X
Y
E2E-X@Y@
Leakage current (mA)
Supply voltage (V)
Proximity Sensor (when OFF)
Protective resistance
AC power supply
E2F-X@Y@
Power supply voltage (V)
Proximity Sensor (OFF)
Protective resistance
AC power supply, 50/60 Hz
Leakage current (mA)
E2F-XjYj