Authorized Distributor:
Note: Specifications subject to change without notice.
Regional Headquarters
Cat. No. D106-E1-02
0407
OMRON Corporation
Industrial Automation Company
Sensing Devices Division H.Q. 
Industrial Sensors Division
Shiokoji Horikawa, Shimogyo-ku, 
Kyoto, 600-8530 Japan 
Tel: (81)75-344-7022/Fax: (81)75-344-7107
OMRON EUROPE B.V.
Sensor Business Unit, 
Carl-Benz-Str. 4, D-71154 Nufringen, 
Germany 
Tel: (49)7032-811-0/Fax: (49)7032-811-199
OMRON ELECTRONICS LLC
1 East Commerce Drive, Schaumburg, 
IL 60173 U.S.A. 
Tel: (1)847-843-7900/Fax: (1)847-843-8568
OMRON ASIA PACIFIC PTE. LTD.
83 Clemenceau Avenue, 
#11-01, UE Square, 
239920 Singapore 
Tel: (65)6835-3011/Fax: (65)6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower, 
200 Yin Cheng Road (M), 
Shanghai, 200120 China 
Tel: (86)21-5037-2222/Fax: (86)21-5037-2200
• Before ordering, read page F-2 in the Sensor General Catalog concerning warranty, limitations of liability, and other related information.
• This document provides information mainly for selecting suitable models and does not contain precautions for correct use and other precautionary information. Always read the Instruction Sheet 
  included with the product before attempting to operate the product. 
Dimensions
I/O Circuit Diagrams
Ratings and Specifications
Output circuit
E2EH-X@D@-T
The load can be connected to either the +V or 0 V side. 
The E2EH-X@D@-T has no polarity. There is no need to be 
concerned about the polarity.
Item
Load current 
Residual voltage
Case, clamping nuts 
Sensing surface 
Cable
Size 
Model 
Sensing distance 
Set distance 
Differential travel 
Power supply voltage (operating voltage range) 
Current consumption 
Leakage current 
Control output
Indicators
Ambient temperature *2
Temperature influence
Degree of protection 
Materials
M12 shielded M18 shielded M30 shielded
E2EH-X3@@ 
3 mm±10% 7mm±10% 12mm±10% 
0 to 2.4 mm 0 to 5.6 mm 0 to 9.6 mm 
15% max. of sensing distance 
12 to 24 VDC, ripple (p-p): 10% max. (10 to 32 VDC) (24 VDC max. at 100°C or higher) 
10 mA max. (DC 3-wire)
0.8 mA max. (DC 2-wire) 
DC 2-wire models: 3 to 100 mA (3 to 50 mA at 100 to 110°C), DC 3-wire models: 100 mA max. (50 mA max. at 100°C or higher) 
DC 2-wire models: 3 V max. (Load current: 100 mA, with 2-m cable; 5 V max. for models with model numbers ending in -T)
DC 3-wire models: 2 V max. (Load current: 100 mA, with 2-m cable) 
DC 2-wire models: D1 models: Operating indicator (red) and setting indicator (yellow), 
D2 models: Operating indicator (yellow); DC 3-wire models: Operating indicator (yellow) 
DC 3-wire models: 0 to 100°C (0 to 120°C for 1,000 hours), DC 2-wire models: 0 to 100°C (0 to 110°C for 1,000 hours)
±10% max. of sensing distance at 23°C in the temperature range of 0 to 70°C 
±15% max. of sensing distance at 23°C in the temperature range of 70 to 100°C
−15% to 20% of sensing distance at 23°C in the temperature range of 100 to 120°C
IEC IP67, DIN 40050-9 IP69K 
Stainless steel (SUL316L) 
PBT
Heat-resistant PVC
E2EH-X7@@ E2EH-X12@@
Refer to the Sensor General Catalog for the influence of surrounding metal and mutual interference and use the Sensor in a suitable environment. 
Operation with power supplied for 1,000 h has been verified at 120°C for DC, 3-wire models and at 110°C for DC 2-wire models. Do not bend the cable repeatedly at 100°C or higher. 
E2EH-X@D@
+V 
(0 V)
0 V 
(+V)
Load
Proximity 
Sensor 
main 
circuit
Load
Brown 1
Blue 4 (NO), 2 (NC)
Proximity 
Sensor 
main 
circuit
+V
0 V
Note 1.
Load
Brown 1
Black 4 (NO), 2 (NC)
Blue 3
Proximity 
Sensor 
main 
circuit
+V
0 V
4-dia. heat-resistant PVC cable with two conductors 
(Conductor cross section: 0.3 mm2, insulator diameter: 
1.3 mm), Standard length: 2 m 
4-dia. heat-resistant PVC cable with three conductors 
(Conductor cross section: 0.3 mm2, insulator diameter: 
1.3 mm), Standard length: 2 m
E2EH-X7@@
24
4
38
10
12
43
M18 × 1 Two clamping nuts
Indicator
(See note 1.)
4
17
38
10
53
E2EH-X3@@
4
17
38
10
9
43
(See note 1.)
M12 × 1 Two clamping nuts
Indicator
E2EH-X3@@-M1@
M12 × 1
M12 × 1
Two clamping nuts
Indicator
4
24
38
10
53
E2EH-X7@@-M1@
M18 × 1
Two clamping nuts
Indicator
M12 × 1
E2EH-X12@@-M1@
5
36
43
10
58
M30 × 1.5 Two clamping nuts
M12 × 1
Indicator
E2EH-X12@@
36
5
43
10
12
48
Indicator
(See note 1.)
M30 × 1.5
Two clamping nuts
Note 1. 
2. 
E2EH-X@B@
The load can be connected to either the +V 
or 0 V side.
Note 1.
2.
Note: All units are in millimeters unless otherwise indicated.
Note 1.
6-dia. heat-resistant PVC cable with two conductors 
(Conductor cross section: 0.5 mm2, insulator diameter: 
1.9 mm), Standard length: 2 m 
6-dia. heat-resistant PVC cable with three conductors 
(Conductor cross section: 0.5 mm2, insulator diameter: 
1.9 mm), Standard length: 2 m
Note 1.
6-dia. heat-resistant PVC cable with two conductors 
(Conductor cross section: 0.5 mm2, insulator diameter: 
1.9 mm), Standard length: 2 m 
6-dia. heat-resistant PVC cable with three conductors 
(Conductor cross section: 0.5 mm2, insulator diameter: 
1.9 mm), Standard length: 2 m
Note 1.