Omron E2E2-X2B1, E2E2-X2C1, E2E2-X5B1, E2E2-X10C1, E2E2-X10B1 Data Sheet

...
Long-barrel Inductive Proximity Sensor
E2E2
Proximity Sensor with a Long Screw Length
• Increased tightening strength. Cable protectors provided as a standard feature.
Be sure to read Safety Precautions on page 9.
Ordering Information
CSM_E2E2_DS_E_2_2
Sensors
DC 2-Wire Models
Model
Appearance Sensing distance
NO NC
Shielded
Unshielded
* Models with different frequencies are also available. The model numbers are E2E2-X@D15 (example: E2E2-X3D15).
DC 3-Wire Models
Appearance Sensing distance
Shielded
Unshielded
AC 2-Wire Models
Appearance Sensing distance
Shielded
Unshielded
M12 M18 M30 M12 M18 M30
M12 M18 M30 M12 M18 M30
M12 M18 M30 M12 M18 M30
3 mm
7 mm
10 mm
8 mm
14 mm
20 mm
2 mm
5 mm
10 mm
5 mm
10 mm
18 mm
2 mm
5 mm
10 mm
5 mm
10 mm
18 mm
E2E2-X3D1 2M * E2E2-X3D2 2M E2E2-X7D1 2M * E2E2-X7D2 2M E2E2-X10D1 2M * E2E2-X10D2 2M E2E2-X8MD1 2M * E2E2-X8MD2 2M E2E2-X14MD1 2M * E2E2-X14MD2 2M E2E2-X20MD1 2M * E2E2-X20MD2 2M
NO NC
E2E2-X2C1 2M E2E2-X2C2 2M E2E2-X5C1 2M E2E2-X5C2 2M E2E2-X10C1 2M E2E2-X10C2 2M E2E2-X5MC1 2M E2E2-X5MC2 2M E2E2-X10MC1 2M E2E2-X10MC2 2M E2E2-X18MC1 2M E2E2-X18MC2 2M
NO NC
E2E2-X2Y1 2M E2E2-X2Y2 2M E2E2-X5Y1 2M E2E2-X5Y2 2M E2E2-X10Y1 2M E2E2-X10Y2 2M E2E2-X5MY1 2M E2E2-X5MY2 2M E2E2-X10MY1 2M E2E2-X10MY2 2M E2E2-X18MY1 2M E2E2-X18MY2 2M
Operation mode
Model
Operation mode
Model
Operation mode
1
E2E2
Accessories (Order Separately)
Mounting Brackets Protective Covers Sputter Protective Covers
Ratings and Specifications
E2E2-X@D@ DC 2-Wire Models
Size
Shielding Shielded Unshielded Shielded Unshielded Shielded Unshielded
Item Model E2E2-X3D@ E2E2-X8MD@ E2E2-X7D@ E2E2-X14MD@ E2E2-X10D@ E2E2-X20MD@
Sensing distance 3 mm±10% 8 mm±10% 7 mm±10% 14 mm±10% 10 mm±10% 20 mm±10%
Set distance *1 0 to 2.4 mm 0 to 6.4 mm 0 to 5.6 mm 0 to 11.2 mm 0 to 8 mm 0 to 16 mm
Differential travel 10% max. of sensing distance
Sensing object
Standard sensing object
Response frequency *2
Power supply voltage (operating voltage range)
Leakage current 0.8 mA max.
Control output
Indicators
Operation mode (with sensing object ap­proaching)
Protection circuits Surge absorber, Load short-circuit protection
Ambient temperature Operating/Storage: 25 to 70°C (with no icing or condensation)
Ambient humidity Operating/Storage: 35% to 95% (with no condensation)
Temperature influence ±10% max. of sensing distance at 23°C in the temperature range of 25 to 70°C
Voltage influence ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 M min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Vibration resistance (destruction)
Shock resistance (destruction)
Degree of protection IEC IP67, in-house standard for oil resistance
Connection method Pre-wired Models (Standard cable length: 2 m)
Weight (packed state) Approx. 65 g Approx. 150 g Approx. 210 g
Materi­als
Accessories Instruction sheet
*1. Use the E2E2 within the range in which the setting indicator (green LED) is ON (except D2 Models). *2. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and
a set distance of half the sensing distance.
Switching capacity
Residual voltage 3 V max. (Load current: 100 mA, Cable length: 2 m)
Case Brass
Sensing surface PBT
Clamping nuts Nickel-plated brass
Toothed washer Zinc-plated iron
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 5.)
Iron, 12 × 12 × 1 mm
1 kHz 800 Hz 500 Hz 400 Hz 100 Hz
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
3 to 100 mA
D1 Models: Operation indicator (red) and setting indicator (green) D2 Models: Operation indicator (red)
D1 Models: NO D2 Models: NC
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
1,000 m/s
M12 M18 M30
Iron, 30 × 30 × 1 mm
Refer to the timing charts under I/O Circuit Diagrams on page 8 for details.
2
10 times each in X, Y, and Z directions
Iron, 18 × 18 × 1 mm
Iron, 30 × 30 × 1 mm
Iron, 30 × 30 × 1 mm
Iron, 54 × 54 × 1 mm
2
E2E2
E2E2-X@C@ DC 3-Wire Models
Size
Shielding Shielded Unshielded Shielded Unshielded Shielded Unshielded
Item Model E2E2-X2C@ E2E2-X5MC@ E2E2-X5C@ E2E2-X10MC@ E2E2-X10C@ E2E2-X18MC@
Sensing distance 2 mm±10% 5 mm±10% 5 mm±10% 10 mm±10% 10 mm±10% 18 mm±10%
Set distance 0 to 1.6 mm 0 to 4 mm 0 to 4 mm 0 to 8 mm 0 to 8 mm 0 to 14 mm
Differential travel 10% max. of sensing distance
Sensing object
Standard sensing object
Response frequency *1 1.5 kHz
Power supply voltage (op­erating voltage range) *2
Leakage current 13 mA max.
Control output
Indicators Operation indicator (red)
Operation mode (with sensing object ap­proaching)
Protection circuits Reverse polarity protection, Surge absorber, Load short-circuit protection
Ambient temperature Operating/Storage: 40 to 85°C (with no icing or condensation)
Ambient humidity Operating/Storage: 35% to 95% (with no condensation)
Temperature influence
Voltage influence ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 M min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between current carry parts and case
Vibration resistance (destruction)
Shock resistance (destruction)
Degree of protection IEC IP67, in-house standard for oil resistance
Connection method Pre-wired Models (Standard cable length: 2 m) and Connector Models
Weight (packed state) Approx. 75 g Approx. 160 g Approx. 220 g
Materi­als
Accessories Instruction sheet
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and
a set distance of half the sensing distance.
*2. A full-wave rectification power supply of 24 VDC
Load current NPN open-collector output, 200 mA max. (55 VDC max.)
Residual voltage 2 V max. (Load current: 200 mA, Cable length: 2 m)
Case Brass
Sensing surface PBT
Clamping nuts Nickel-plated brass
Toothed washer Zinc-plated iron
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 5.)
Iron, 12 × 12 × 1 mm
12 to 24 VDC (10 to 55 VDC), ripple (p-p): 10% max.
C1 Models: NO C2 Models: NC
±15% max. of sensing distance at 23°C in the temperature range of 40 to 85°C ±10% max. of sensing distance at 23°C in the temperature range of 25 to 70°C
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
1,000 m/s
M12 M18 M30
Iron, 15 × 15 × 1 mm
400 Hz 600 Hz 200 Hz 400 Hz 100 Hz
Refer to the timing charts under I/O Circuit Diagrams on page 8 for details.
2
10 times each in X, Y, and Z directions
±20% (average value) can be used.
Iron, 18 × 18 × 1 mm
Iron, 30 × 30 × 1 mm
Iron, 30 × 30 × 1 mm
Iron, 54 × 54 × 1 mm
3
E2E2
E2E2-X@Y@ AC 2-Wire Models
Size
Shielding Shielded Unshielded Shielded Unshielded Shielded Unshielded
Item Model E2E2-X2Y@ E2E2-X5MY@ E2E2-X5Y@ E2E2-X10MY@ E2E2-X10Y@ E2E2-X18MY@
Sensing distance 2 mm±10% 5 mm±10% 5 mm±10% 10 mm±10% 10 mm±10% 18 mm±10%
Set distance 0 to 1.6 mm 0 to 4 mm 0 to 4 mm 0 to 8 mm 0 to 8 mm 0 to 14 mm
Differential travel 10% max. of sensing distance
Sensing object
Standard sensing object
Response frequency
Power supply voltage (op­erating voltage range) *1
Leakage current 1.7 mA max.
Control output
Indicators Operation indicator (red)
Operation mode (with sensing object ap­proaching)
Ambient temperature *1, 2 Operating/Storage: 40 to 85°C (with no icing or condensation)
Ambient humidity Operating/Storage: 35% to 95% (with no condensation)
Temperature influence
Voltage influence ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 M min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 4,000 VAC, 50/60 Hz for 1 minute between current carry parts and case
Vibration resistance (destruction)
Shock resistance (destruction)
Degree of protection IEC IP67, in-house standard for oil resistance
Connection method Pre-wired Models (Standard cable length: 2 m) and Connector Models
Weight (packed state) Approx. 65 g Approx. 150 g Approx. 210 g
Materi­als
Accessories Instruction sheet
*1. When supplying 24 VAC to any of the above models, make sure that the operating ambient temperature range is at least −25°C to 85°C. *2. When using an M18 or M30 Connector Model at an ambient temperature between 70 and 85°C, make sure that the Sensor has a control output (load current) of 5
to 200 mA max.
Load current *2 5 to 200 mA 5 to 300 mA
Residual voltage Refer to Engineering Data on page 5.
Case Brass
Sensing surface PBT
Clamping nuts Nickel-plated brass
Toothed washer Zinc-plated iron
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 5.)
Iron, 12 × 12 × 1 mm
25 Hz
24 to 240 VAC (20 to 264 VAC), 50/60 Hz
Y1 Models: NO Y2 Models: NC
±15% max. of sensing distance at 23°C in the temperature range of 40 to 85°C, ±10% max. of sensing distance at 23°C in the temperature range of 25 to 70°C
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
1,000 m/s
M12 M18 M30
Iron, 15 × 15 × 1 mm
Refer to the timing charts under I/O Circuit Diagrams on page 8 for details.
2
10 times each in X, Y, and Z directions
Iron, 18 × 18 × 1 mm
Iron, 30 × 30 × 1 mm
Iron, 30 × 30 × 1 mm
Iron, 54 × 54 × 1 mm
4
E2E2
Engineering Data
(Typical)
Sensing Area
Shielded Models E2E2-X@D@ E2E2-X@C@/-X@Y@
12
10
Distance X (mm)
8
6
4
Y
2
0
20 15 10 5 0 5 10 15 20
X
E2E2-X10
E2E2-X7
E2E2-X3
Distance Y (mm)
12
10
Distance X (mm)
8
6
4
2
0
10 50 51015−15
Y
X
Unshielded Models E2E2-X@MD@ E2E2-X@MC@/-X@MY@
30
25
Distance X (mm)
20
15
10
5
E2E2
-X20M
E2E2
-X14M
Y
X
E2E2
-X8M
30
25
Distance X (mm)
20
15
10
5
Y
X
E2E2-X10
E2E2-X5
E2E2
-X2
Distance Y (mm)
E2E2-X18M
E2E2-X10M
E2E2-X5M
0
20 10 0 10 20 30−30
Distance Y (mm)
0
20 10 0 10 20 30−30
Distance Y (mm)
Leakage Current Residual Output Voltage
E2E2-X@D@ E2E2-X@Y@ E2E2-X@D@
1.0
0.8
0.6
Leakage current (mA)
0.4
0.2
0 5 10 15 20 25 30
Power supply voltage (V)
1.4
1.2
1.0
Leakage current (mA)
0.8
0.6
0.4
0.2 Proximity
Sensor (OFF)
0 50 100 150 200 250 300
Protective resistance
mA
V
Power supply voltage (V)
AC power
6
5
4
Residual output voltage (V)
3
2
1 3 5 10 30 50 100
Load current (mA)
5
E2E2
E2E2-X@Y@ at 24 VAC E2E2-X@Y@ at 100 VAC E2E2-X@Y@ at 200 VAC
30
25
20
Load voltage VL (V)
15
Residual output voltage
V
10
5
Residual load voltage
0
1 3 5 10 30 50 100 300 500
V
A
L
Load current (mA)
ON
24 VAC
OFF
120
Residual output voltage
100
80
Load voltage VL (V)
V
60
40
20
Residual load voltage
0
1 3 5 10 30 50 100 300 500
A
V
L
Load current (mA)
100 VAC
ON
OFF
Influence of Sensing Object Size and Material
E2E2-X3D@ E2E2-X7D@ E2E2-X10D@
4
@d
3.5
Distance X (mm)
2.5
1.5
0.5
X
3
2
1
t =
mm
1
Iron
Stainless steel (SUS304)
Brass
Aluminum Copper
8
@d
7
6
Distance (mm)
5
4
3
2
1
t =
mm
1
X
Iron
Stainless steel (SUS304)
Brass
Aluminum
Copper
240
Residual output voltage
200
160
Load voltage VL (V)
120
80
40
Residual load voltage
0
1 3 5 10 30 50 100
12
@d
t =
mm
1
X
10
Distance X (mm)
8
6
4
2
V
V
L
A
Load current (mA)
ON
200 VAC
OFF
300 500
Iron
Stainless steel (SUS304)
Brass Aluminum
Copper
0 5 10 15 20 25 30 35 40
Side length of sensing object d (mm)
0 10 20 30 40 50
Side length of sensing object d (mm)
0 10 20 30 40 50 60 70
E2E2-X8MD@ E2E2-X14MD@ E2E2-X20MD@
12
@d
t =
mm
1
X
10
Distance X (mm)
8
6
4
2
0 10 20 30 40 50 60 70
Side length of sensing object d (mm)
Iron
Stainless steel (SUS304)
Brass
Aluminum Copper
25
@d
t =
mm
1
X
20
Distance X (mm)
15
10
5
0 10 20 30 40 50 60 70
Side length of sensing object d (mm)
Iron
Stainless steel (SUS304)
Brass
Aluminum Copper
25
@d
t =
X
20
Distance X (mm)
15
10
5
0 10 20 30 40 50 60 70 80 90 100
Side length of sensing object d (mm)
mm
1
Iron
Stainless steel (SUS304)
Brass Aluminum
Copper
Side length of sensing object d (mm)
6
E2E2-X2C@/-X2Y@ E2E2-X5C@/-X5Y@ E2E2-X10C@/-X10Y@
2.5
@d
X
2
Distance X (mm)
1.5
1
0.5
t =
mm
1
Stainless steel (SUS304)
Iron
Brass
Aluminum
7
@d
X
6
5
Distance X (mm)
4
3
2
1
t =
12
1
mm
Iron
Stainless steel (SUS304)
Brass
Aluminum
@d
X
10
Distance X (mm)
8
6
4
2
t =
mm
1
E2E2
Iron
Stainless steel (SUS304)
Brass
Aluminum
0 5 10 15 20 25
Side length of sensing object d (mm)
0 10 20 30 40 50
Side length of sensing object d (mm)
0 10 20 30 40 50 60
Side length of sensing object d (mm)
E2E2-X5MC@/-X5MY@ E2E2-X10MC@/-X10MY@ E2E2-X18MC@/-X18MY@
7
@d
t =
mm
1
X
6
5
Distance X (mm)
4
3
2
1
0 10 20 30 40 50
Stainless steel (SUS304)
Side length of sensing object d (mm)
Iron
Brass
Aluminum
12
@d
t =
mm
1
X
10
Distance X (mm)
8
6
4
2
0 10 20 30 40 50 60
Stainless steel (SUS304)
Aluminum
Side length of sensing object d (mm)
Iron
Brass
25
@d
t =
mm
1
X
20
Distance X (mm)
15
Stainless steel (SUS304)
10
5
0 20 40 60 80 100
Side length of sensing object d (mm)
Iron
Brass
Aluminum
7
I/O Circuit Diagrams
DC 2-Wire Models
Operation
mode
NO
NC
Model Timing Charts Output circuit
E2E2-X3D1 E2E2-X7D1 E2E2-X10D1 E2E2-X8MD1 E2E2-X14MD1 E2E2-X20MD1
E2E2-X3D2 E2E2-X7D2 E2E2-X10D2 E2E2-X8MD2 E2E2-X14MD2 E2E2-X20MD2
Non-sensing
Sensing object
(%)
Non-sensing
Sensing object
(%)
area
area
Set position
Unstable sensing area
100 080
Rated sensing distance
100 0
Rated sensing distance
Stable sensing
area
Stable sensing
area
Proximity Sensor
ON
Setting indicator (green)
OFF
ON
Operation indicator (red)
OFF
ON
Control output
OFF
Proximity Sensor
ON
Operation indicator (red)
OFF
ON
Control output
OFF
E2E2
Brown
Load
+V
Proximity Sensor main circuit
Blue
Note: The load can be connected to either
the +V or 0 V side.
0 V
DC 3-Wire Models
Operation
mode
E2E2-X2C1 E2E2-X5C1
NO
E2E2-X10C1 E2E2-X5MC1 E2E2-X10MC1 E2E2-X18MC1
E2E2-X2C2 E2E2-X5C2
NC
E2E2-X10C2 E2E2-X5MC2 E2E2-X10MC2 E2E2-X18MC2
Model Timing Charts Output circuit
Sensing object
Operation indicator (red)
Control output
Sensing object
Operation indicator (red)
Control output
Present
Not present
ON
OFF
ON
OFF
Present
Not present
ON
OFF
ON
OFF
Proximity Sensor main circuit
100
Brown
Black
Blue
+V
Load
0 V
8
AC 2-Wire Models
Operation
mode
Model Timing Charts Output circuit
E2E2-X2Y1 E2E2-X5Y1
NO
E2E2-X10Y1 E2E2-X5MY1 E2E2-X10MY1 E2E2-X18MY1
E2E2-X2Y2 E2E2-X5Y2
NC
E2E2-X10Y2 E2E2-X5MY2 E2E2-X10MY2 E2E2-X18MY2
Safety Precautions
WARNING
This product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purposes.
Sensing object
Operation indicator (red)
Control output
Sensing object
Operation indicator (red)
Control output
Not present
Not present
Present
ON
OFF
ON
OFF
Present
ON
OFF
ON
OFF
Proximity Sensor main circuit
Brown
Blue
E2E2
Load
Precautions for Correct Use
Do not use this product under ambient conditions that exceed the ratings.
Design
Influence of Surrounding Metal
When mounting the Sensor within a metal panel, ensure that the clearances given in the following table are maintained.
Model Item
DC 2-Wire Models E2E2-X@D@
DC 3-Wire Models E2E2-X@C@ AC 2-Wire Models E2E2-X@Y@
Shielded
Unshielded
Shielded
Unshielded
l000
d121830
D00 0
m 8 20 40
n182745
l152230
d407090
D152230
m204070
n407090
l000
d121830
D00 0
m 8 20 40
n182745
l152230
d405590
D152230
m204070
n365490
M12 M18 M30
l
m
(Unit: mm)
D
d dia.
n
m
l
9
E2E2
Mutual Interference
When installing Sensors face-to-face or side-by-side, ensure that the minimum distances given in the following table
A
are maintained.
Mutual Interference
Model Item
A
Shielded
DC 2-Wire Models E2E2-X@D@
Unshielded
DC 3-Wire Models E2E2-X@C@ AC 2-Wire Models E2E2-X@Y@
Note: Values in parentheses apply to Sensors operating at different frequencies.
Shielded
Unshielded
B
A
B
A3050100 B203570 A 120 200 300 B 100 110 200
M12 M18 M30
30
(20)
20
(12)
120
(60)
100
(50)
Mounting
Tightening Torque
Do not tighten the nut with excessive force. A washer must be used with the nut. The following strengths assume washers are being used.
Model Torque
M12 30 N·m M18 70 N·m M30 180 N·m
50
(30)
35
(18)
200
(100)
110 (60)
Relationship between Sizes and
B
(Unit: mm)
100 (50)
70
(35)
300
(100)
200
(100)
Models
Size Model
Shielded
M12
Unshielded
Shielded
M18
Unshielded
Shielded
M30
Unshielded
E2E2-X3D@ E2E2-X2C@ E2E2-X2Y@
E2E2-X8MD@ E2E2-X5MC@ E2E2-X5MY@
E2E2-X7D@ E2E2-X5C@ E2E2-X5Y@
E2E2-X14MD@ E2E2-X10MC@ E2E2-X10MY@
E2E2-X10D@ E2E2-X10C@ E2E2-X10Y@
E2E2-X20MD@ E2E2-X18MC@ E2E2-X18MY@
10
E2E2
S
(Unit: mm)
Dimensions Unless otherwise specified, the tolerance class IT16 is used for dimensions in this data sheet.
hielded Unshielded
E2E2-X3D@/E2E2-X2C@/E2E2-X2Y@
21 dia.
17
4
M12 × 1
*1. 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm
Standard length: 2 m 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm Standard length: 2 m The cable can be extended to up to 200 m (Separate metal conduit.) *2. D Models: Operation indicator (red) and setting indicator (green), C/Y Models: Operation indicator (red)
60
55
10
Two clamping nuts
Toothed washer
E2E2-X7D@/E2E2-X5C@/E2E2-X5Y@
29 dia.
24
4
M18 × 1
*1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm
Standard length: 2 m 6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm Standard length: 2 m The cable can be extended to up to 200 m (Separate metal conduit.) *2. D Models: Operation indicator (red) and setting indicator (green), C/Y Models: Operation indicator (red)
65
60
10
Two clamping nuts
Toothed washer
9
Indicators *2
2
, Insulator diameter: 1.3 mm),
2
, Insulator diameter: 1.3 mm),
12
Indicators *2
2
, Insulator diameter: 1.9 mm),
2
, Insulator diameter: 1.9 mm),
E2E2-X8MD@/E2E2-X5MC@/E2E2-X5MY@
21 dia.
17
*1
9 dia.
M12 × 1
*1. 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm
Standard length: 2 m 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm Standard length: 2 m The cable can be extended to up to 200 m (Separate metal conduit.) *2. D Models: Operation indicator (red) and setting indicator (green), C/Y Models: Operation indicator (red)
60
55
47
Two clamping nuts
Toothed washer
9
10
Indicators *2
2
, Insulator diameter: 1.3 mm),
2
, Insulator diameter: 1.3 mm),
*1
E2E2-X14MD@/E2E2-X10MC@/E2E2-X10MY@
29 dia.
24
*1
10
14.8 dia.
M18 × 1
*1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm
Standard length: 2 m 6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm Standard length: 2 m The cable can be extended to up to 200 m (Separate metal conduit.) *2. D Models: Operation indicator (red) and setting indicator (green), C/Y Models: Operation indicator (red)
65
60
4
Two clamping nuts
Toothed washer
12
10
Indicators *2
2
, Insulator diameter: 1.9 mm),
2
, Insulator diameter: 1.9 mm),
*1
E2E2-X10D@/E2E2-X10C@/E2E2-X10Y@
42 dia.
36
5
M30 × 1.5
*1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm Standard length: 2 m 6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm Standard length: 2 m The cable can be extended to up to 200 m (Separate metal conduit.) *2. D Models: Operation indicator (red) and setting indicator (green), C/Y Models: Operation indicator (red)
70
65
Two clamping nuts
Toothed washer
10
2
, Insulator diameter: 1.9 mm),
2
, Insulator diameter: 1.9 mm),
12
Indicators *2
*1
E2E2-X20MD@/E2E2-X18MC@/E2E2-X18MY@
42 dia.
36
13
26.8 dia.
M30 × 1.5
*1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm
Standard length: 2 m 6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm Standard length: 2 m The cable can be extended to up to 200 m (Separate metal conduit.) *2. D Models: Operation indicator (red) and setting indicator (green), C/Y Models: Operation indicator (red)
5
70
65
Two clamping nuts
Toothed washer
2
, Insulator diameter: 1.9 mm),
2
, Insulator diameter: 1.9 mm),
10
12
*1
Indicators *2
Mounting Hole Dimensions
Dimension
F (mm)
F
Note 1. Two clamping nuts and one toothed washer are provided with each Sensors.
2. The model number is laser-marked on the cable section and milled section.
M12 M18 M30
+0.5
12.5 dia. 18.5 dia. 30.5 dia.
0
+0.5 0
+0.5 0
In the interest of product improvement, specifications are subject to change without notice.
11
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2009 All Right Reserved.
2009.1
Loading...