Linear Output Proximity Sensor with
High-accuracy Resolution
Resolution is 0.05% of the maximum sensing
distance. The model with a sensing distance of
1.2 mm ensures a resolution of 0.6 om.
Models with response frequencies ranging from 10
to 3 kHz are available.
The M30-size model ensures a sensing distance of
10 mm.
Satisfies IEC IP67 requirements, thus detecting the
displacement of metal objects without being
influenced by water and oil spray.
The E2CA has a standard linear output of 4 to
20 mA and connects to the Linear Discrimination
Unit, Digital Panel Meter, and I/O Unit of the
Programmable Controller.
The E2CA’s compact amplifier can be plugged into
surface mounting sockets thus greatly reducing
wiring effort and ensuring easy mounting.
Supply voltage (operating voltage range) 100 to 240 VAC
Current consumption
Sensing objectFerrous metal
Sensing range
(with standard sensing object)
Linear output
characteristics
Switching output
characteristics
Sensitivity
adjustment
function
Output
Switching output modeNormally open or normally closed (selectable with selector on front panel)
Cord length compensation3 or 5 m (selectable with selector on front panel)
IndicatorsPOWER, SPAN (linear range), and OPER (switching output) indicators
Ambient temperatureOperating: --25flCto70flC (Sensor) and --10flCto55flC (Amplifier) with no icing
Ambient humidityOperating: 35% to 95% (Sensor) and 35% to 85% (Amplifier)
Temperature influence‒10% FS max. of linear output current at 23flC in the rated ambient operating
Voltage influenceDC power supply model: ‒0.5% FS max. of linear output current at a voltage between
Insulation resistance
Dielectric strengthDC power supply model: 1,000 VAC (50/60 Hz) for 1 min between current carry parts
Vibration resistanceSensor (destruction): 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and
Shock resistanceSensor (destruction): 500 m/s2(approx. 50G) 3 times each in X, Y, and Z directions
Degree of protectionSensor: IEC60529 IP67 (JEM IP67g waterproof and oil-proof)
Cord length
Weight
(see note 4)
Material
Resolution0.05% FS
Linearity‒2% FS‒1.5% FS
Response frequency
(see note 1)
Differential travel2% to 5% of rated sensing distance
Response frequency
(see note 2)
Sensitivity adjustment
(switching output)
Linear output
current
adjustment
Linear output
(see note 3)
Switching output100 mA max. transistor photocoupler output at 40 VDC with max. residual voltage of 2 V
SensorApprox. 40 g
AmplifierApprox. 250 gApprox. 140 gApprox. 250 gApprox. 140 g
Case
Sensing surface
CordPolyethylene
4mA 4-mA adjustment at 20% of rated sensing distance
20 mA 20-mA adjustment at rated sensing distance
50/60 Hz
(90to264VAC)
60 mA max.70 mA max.60 mA max.70 mA max.
0.3 to 1.5 mm (8 x 8 x 1 mm iron)0.4to2mm(12x12x1mmiron)
10 kHz (--1 dB)10 kHz (--1 dB)
1kHz800 Hz
Adjustments of switching output within sensing range
4 to 20 mA (with permissible load resistance of 0 to 300 Y)
temperature range of the Sensor and Amplifier Units
80% and 120% of the rated power supply voltage
AC power supply model: ‒0.5% FS max. of linear output current at a voltage between
90% and 110% of the rated power supply voltage
50 MY min. (at 500 VDC) between the case and current carry parts
and case
AC power supply model: 1,500 VAC (50/60 Hz) for 1 min between current carry parts
and case
Z directions
Amplifier (destruction): 10 to 25 Hz, 2-mm double amplitude for 2 hours each in X, Y, and
Z directions
Amplifier (destruction): 100 m/s2(approx. 10G) 3 times each in X, Y, and Z directions
Sensor: 2-conductor, 3-m-long (standard length) or 5-m-long shielded cord
Supply voltage (operating voltage range) 100 to 240 VAC
Current consumption60 mA max.70 mA max.60 mA max.70 mA max.
Sensing objectFerrous metal
Sensing range (with standard sensing
object)
Linear output
characteristics
Switching output
characteristics
Sensitivity
adjustment
function
Output
Switching output mode
Cord length compensation3 or 5 m (selectable with selector on front panel)
IndicatorsPOWER, SPAN (linear range), and OPER (switching output) indicators
Ambient temperature
Ambient humidityOperating: 35% to 95% (Sensor) and 35% to 85% (Amplifier)
Temperature influence‒10% FS max. of sensing distance at 23flC in the rated ambient operating temperature
Voltage influenceDC power supply model: ‒0.5% FS max. of linear output current at a voltage between
Insulation resistance50 MY min. (at 500 VDC) between the case and current carry parts
Dielectric strengthDC power supply model: 1,000 VAC (50/60 Hz) for 1 min between current carry parts
Vibration resistanceSensor (destruction): 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and
Shock resistanceSensor (destruction): 500 m/s2(approx. 50G) 3 times each in X, Y, and Z directions
Degree of Protection
Cord lengthSensor: 2-conductor, 3-m-long (standard length) or 5-m-long shielded cord
Weight
(see note 4)
Material
Resolution0.05% FS
Linearity‒1.5% FS‒2% FS
Response frequency
(see note 1)
Differential travel2% to 5% of rated sensing distance
Response frequency
(see note 2)
Sensitivity adjustment
(switching output)
Linear output
current
adjustment
Linear output
(see note 3)
Switching output
SensorApprox. 60 gApprox. 160 g
AmplifierApprox. 250 gApprox. 140 gApprox. 250 gApprox. 140 g
CaseBrass
Sensing surfaceABS resin
CordPolyethylene
4mA
20 mA 20-mA adjustment at rated sensing distance
50/60 Hz
(90to264VAC)
1to5mm(18x18x1mmiron)2to10mm(30x30x1mmiron)
5 kHz (--1 dB)3 kHz (--1 dB)
350 Hz100 Hz
Adjustments of switching output within sensing range
4-mA adjustment at 20% of rated sensing distance
4 to 20 mA (with permissible load resistance of 0 to 300 Y)
100 mA max. transistor photocoupler output at 40 VDC with max. residual voltage of 2 V
Normally open or normally closed (selectable with selector on front panel)
Operating: --25flCto70flC (Sensor) and --10flCto55flC (Amplifier) with no icing
range of --10flC and 40flC
80% and 120% of the rated power supply voltage
AC power supply model: ‒0.5% FS max. of linear output current at a voltage between
90% and 110% of the rated power supply voltage
and case
AC power supply model: 1,500 VAC (50/60 Hz) for 1 min between current carry parts
and case
Z directions
Amplifier (destruction): 10 to 25 Hz, 2-mm double amplitude for 2 hours each in X, Y, and
Z directions
Amplifier (destruction): 100 m/s2(approx. 10G) 3 times each in X, Y, and Z directions
Sensor: IEC60529 IP67 (JEM IP67g waterproof and oil-proof)
E2CA-X5AE2CA-X10A
12 to 24 VDC
(10to30VDC),
ripple (p-p): 10%
max.
100 to 240 VAC
50/60 Hz
(90to264VAC)
12 to 24 VDC
(10to30VDC),
ripple (p-p): 10%
max.
Note: 1. This is a frequency decreasing the level of linear output current by 1 dB.
2. This is a response frequency measured in accordance with CENELEC standards.
3. The maximum load impedance of the E2CA-AL4 is 150 Y at a supply voltage of 12 V.
4. The weight includes the 3-m-long cord. The weights of the Amplifiers do not include connecting sockets.