• Ensures a sensing distance approximately 1.5 to 2
times larger than that of any conventional OMRON
Sensor.
• Problems such as the collision of workpieces are
eliminated.
• Full range of standard sizes (M8, M12, M18 and
M30; both long and short barrels)
• Modular construction simplifies customization.
<READ AND UNDERSTAND THIS CATALOG>
Please read and understand this catalog before purchasing
the products. Please consult your OMRON representative if
you have any questions or comments.
Ambient air temperatureOperating: −40°C to 70°C, Storage:
Temperature in
Ambient humidityOperating: 35% to 95%, Storage: 35% to 95%
Voltage influence±1% max. of sensing distance in rated voltage range ±15%
Insulation resistance50 MΩ min. (at 500 VDC) between current carry parts and case
Dielectric strength1,000 VAC at 50/60 Hz for 1 min between current carry parts and case
Vibration resistance10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance
Standard and listings (See note 3.)IEC60529: IP67, Degree of protection
Connection method-WP models: Pre-wired models (Standard length: 2 m)
Weight
(packaged)
MaterialCaseStainless steel or brass-nickel platedBrass-nickel plated
Note 1. The response frequency is an average value. Measurement conditions are as follows: standard target, a distance of twice the standard
target distance between targets, and a setting distance of half the sensing distance.
2. When using any model at an ambient temperature between −40°C and −25°C and a power voltage between 30 and 32 VDC, use a load
current of 100 mA max.,
3. For USA and CANADA : use class 2 circuit only.
Load current
(See note 2.)
Residual voltage2 V max. (under load current of 200 mA with cable length of 2 m)
fluence (See note 2.)±10% max. of sensing distance at 23°C within temperature range of −25°C to 70°C
Pre-wired modelApprox. 65 gApprox. 85 g
M12 connector modelM12 connector models: Approx. 20 g
Sensing surfacePBT
CablePVC
Clamping nutBrass-nickel plated
E2A-S08@S02-@@-C1
E2A-S08@S02-@@-C2
12 to 24 VDC. Ripple (p-p): 10% max.
(10 to 32 VDC)
-C models: NPN open collector
200 mA max. (32 VDC max.)
-B1/-C1 models: NO
-B2/-C2 models: NC
For details, refer to the timing charts.
Surge suppressor, Short-circuit protection
±15% max. of sensing distance at 23°C within temperature range of −40°C to 70°C
2
500 m/s
EN60947-5-2: EMC
-M1 models: M12 4-pin connector models
-M5 models: M8 3-pin connector models
M8 connector models: Approx. 15 g
, 10 times each in X, Y and Z directions 1,000 m/s2, 10 times each in X, Y and Z directions
Do not impose an excessive voltage on the E2A, otherwise it may be
damaged. Do not impose AC current (100 to 240 VAC) on any DC
model, otherwise it may be damaged.
Load Short-circuit
Do not short-circuit the load, or the E2A may be damaged.
The E2A’s short-circuit protection function will be valid if the polarity
of the supply voltage imposed is correct and within the rated voltage
range.
■ Correct Use
Designing
Power Reset Time
The Proximity Sensor is ready to operate within 100 ms after power
is supplied. If power supplies are connected to the Proximity Sensor
and load respectively, be sure to supply power to the Proximity Sensor before supplying power to the load.
Effects of Surrounding Metal
When mounting the E2A within a metal panel, ensure that the clearances given in the following table are maintained.
Wiring
Be sure to wire the E2A and load correctly, otherwise it may be damaged.
Connection with No Load
Be sure to insert loads when wiring. Make sure to connect a proper
load to the E2A in operation, otherwise it may damage internal elements.
Do not expose the product to flammable or explosive gases.
Do not disassemble, repair, or modify the product.
Power OFF
The Proximity Sensor may output a pulse signal when it is turned
OFF. Therefore, it is recommended that the load be turned OFF
before turning OFF the Proximity Sensor.
Power Supply Transformer
When using a DC power supply, make sure that the DC power supply has an insulated transformer. Do not use a DC power supply with
an auto-transformer.
Mutual Interference
When installing two or more Sensors face-to-face or side-by-side,
ensure that the minimum distances given in the following table are
maintained.
TypeDimension M8 M12M18M30
Short
barrel
Shielded l000
m4.5122445
d------2745
D 001.54
n12182745
Nonshielded
Note 1. In the case of using the supplied nuts.
14E2ACylindrical Proximity Sensor
l1215223040
m820487090
d24407090 120
D12152230 40
n24407090 120
If true flash mounting is necessary, apply a free zone of
1.5 mm.
2. In the case of using the supplied nuts.
If true flush mounting is necessary, apply a free zone of
4 mm.
(See note
1.)
0
(See note 2.)
(Unit: mm)
Long
barrel
TypeDimensionM8M12M18M30
Short
barrel
ShieldedA203060110
B15203570
Nonshielded
A80120200300300
B60100120200300
(Unit: mm)
Long
barrel
Wiring
High-tension Lines
Wiring through Metal Conduit:
If there is a power or high-tension line near the cable of the Proximity
Sensor, wire the cable through an independent metal conduit to prevent against Proximity Sensor damage or malfunctioning.
Cable Extension
Standard cable length is less than 200 m.
The tractive force is 50 N.
Mounting
The Proximity Sensor must not be subjected to excessive shock with
a hammer when it is installed, otherwise the Proximity Sensor may
be damaged or lose its water-resistivity.
Do not tighten the nut with excessive force. A washer must be used
with the nut.
TypeTorque
M8Stainless steel type 9 N·m
Brass type4 N·m
M1230 N·m
M1870 N·m
M30180 N·m
Maintenance and Inspection
Periodically perform the following checks to ensure stable operation
of the Proximity Sensor over a long period of time.
1. Check for mounting position, dislocation, looseness, or distortion
of the Proximity Sensor and sensing objects.
2. Check for loose wiring and connections, improper contacts, and
line breakage.
3. Check for attachment or accumulation of metal powder or dust.
4. Check for abnormal temperature conditions and other environ-
mental conditions.
5. Check for proper lighting of indicators (for models with a set indicator.)
Never disassemble or repair the Sensor.
Environment
Water Resistivity
Do not use the Proximity Sensor underwater, outdoors, or in the rain.
Operating Environment
Be sure to use the Proximity Sensor within its operating ambient
temperature range and do not use the Proximity Sensor outdoors so
that its reliability and life expectancy can be maintained. Although
the Proximity Sensor is water resistive, a cover to protect the Proximity Sensor from water or water-soluble machining oil is recommended so that its reliability and life expectancy can be maintained.
Do not use the Proximity Sensor in an environment with chemical
gas (e.g., strong alkaline or acid gasses including nitric, chromic,
and concentrated sulfuric acid gases).
Inrush Current
A load that has a large inrush current (e.g., a lamp or motor) will
damage the Proximity Sensor, in which case connect the load to the
Proximity Sensor through a relay.
E2A Cylindrical Proximity Sensor 15
Warranties, Limitations of Liability
■ WARRANTY
OMRON’s exclusive warranty is that the products are free
from defects in materials and workmanship for a period of
one year (or other period if specified) from date of sale by
OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION,
EXPRESS OR IMPLIED, REGARDING NONINFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR
PARTICULAR PURPOSE OF THE PRODUCTS. ANY
BUYER OR USER ACKNOWLEDGES THAT THE BUYER
OR USER ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS
OF THEIR INTENDED USE. OMRON DISCLAIMS ALL
OTHER WARRANTIES, EXPRESS OR IMPLIED.
Application Considerations
■ SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any
standards, codes, or regulations that apply to the
combination of products in the customer’s application or use
of the products.
Take all necessary steps to determine the suitability of the
product for the systems, machines, and equipment with
which it will be used.
■ LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL,
INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF
PROFITS OR COMMERCIAL LOSS IN ANY WAY
CONNECTED WITH THE PRODUCTS, WHETHER SUCH
CLAIM IS BASED ON CONTRACT, WARRANTY,
NEGLIGENCE, OR STRICT LIABILITY.
In no event shall responsibility of OMRON for any act exceed
the individual price of the product on which liability is
asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR
WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING
THE PRODUCTS UNLESS OMRON’S ANALYSIS
CONFIRMS THAT THE PRODUCTS WERE PROPERLY
HANDLED, STORED, INSTALLED, AND MAINTAINED AND
NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE,
OR INAPPROPRIATE MODIFICATION OR REPAIR.
Know and observe all prohibitions of use applicable to this
product.
NEVER USE THE PRODUCTS FOR AN APPLICATION
INVOLVING SERIOUS RISK TO LIFE OR PROPERTY
WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE
HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND
THAT THE OMRON PRODUCT IS PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Disclaimers
■ CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at
any time based on improvements and other reasons. Consult
with your OMRON representative at any time to confirm
actual specifications of purchased product.
ALL DIMENSIONS SHOW
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. D100-E1-01B
In the interest of product improvement, specifications are subject to change without notice.