Cylindrical Proximity Sensor
E2AG
• Highest value-performance ratio for standard applications
• Shielded and unshielded models with standard sensing range
Ordering information
Appearance Sensing distance Output
Shielded
Unshielded
Note:Add the cable length to the model number (example: E2AG-M12KS02-WP-B1 2M).
M8
M12 E2AG-M12KS02-WP-B1 E2AG-M12KS02-WP-B2
M18 E2AG-M18KS05-WS-B1 E2AG-M18KS05-WS-B2
M30 E2AG-M30KS10-WS-B1 E2AG-M30KS10-WS-B2
M8
M12 E2AG-M12KN05-WP-B1 E2AG-M12KN05-WP-B2
M18 E2AG-M18KN10-WS-B1 E2AG-M18KN10-WS-B2
M30 E2AG-M30KN18-WS-B1 E2AG-M30KN18-WS-B2
1.5 mm
2 mm
2 mm
5 mm
5 mm
10 mm
10 mm
PNP
PNP
18 mm
Operation mode NO Operation mode NC
E2AG-S08KS01-WP-B1 E2AG-S08KS01-WP-B2
E2AG-S08KN02-WP-B1 E2AG-S08KN02-WP-B2
1E2AG
Page 2
Model Number Legend
E2AG-@@@@@-@-@@-@
123 45 6 78 9
1. Housing shape and material M: Cylindrical, metric threaded, brass S: Cylindrical, metric threaded, stainless steel (only M8)
2. Housing size 08: 8 mm 12: 12 mm 18: 18 mm 30: 30 mm
3. Barrel length K: Standard length
4. Shield S: Shielded N: Unshielded
eg., E2AG-M 12 K N 05-WP-B 1-2M
able length: 2 m
C NO DC, 3 wire, PNP pre-wired, PVC, dia 4 mm Sensing distance 3 mm Unshielded Standard length M12 Cylindrical, brass
5. Sensing distance Numeral: Sensing distance, e.g. 02=2 mm,10=10 mm Exceptional case: 01=1.5 mm
6. Kind of connection WP: pre-wired, PVC, dia 4 mm WS: pre-wired, PVC, dia 6 mm
7. Power Source and Output B: DC, 3-wire, PNP open collector
8. Operation mode 1: Normally open (NO) 2: Normally closed (NC)
9. Cable length Numeral: Cable length
eg., E2AG-S 08 K S 01-WP-B 1-2M
Cable length: 2 m NO DC, 3 wire, PNP pre-wired, PVC, dia 4 mm
Sensing distance 1.5 mm Shielded Standard length
M8 Cylindrical, stainless steel
2 Cylindrical Proximity Sensor
Page 3
Specifications
Item M8 M12 M18 M30
Shielded Unshielded Shielded Unshielded Shielded Unshielded Shielded Unshielded
E2AG­S08KS01-@-B1 E2AG­S08KS01-@-B2
Sensing distance
Differential travel 10% max. of sensing distance
Detectable object
Standard sensing object
Response frequency
Power supply voltage (operating voltage range)
Current consumption
Load current
Residual
output
Control
voltage
Indicator Operation indicator (yellow)
Operation mode (with sensing object approaching)
Protection circuits
Ambient temperature range
Ambient humidity range
Voltage influence
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Degree of protection
Connection method
Weight Approx. 55 g Approx. 65 g Approx. 140 g Approx. 190 g
Case Stainless steel (SUS303) Nickel plated brass
Sensing surface
Materials
*1.
The response frequency is an average value. Measurement conditions are as follows:standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
1.5 mm ±10% 2 mm ±10% 5 mm ±10% 10 mm ±10% 18 mm ±10%
Ferrous metal (The sensing distance decrease with non-ferrous metal. Refer to Engineering Data on pages 4 and 5)
Iron 8×8×1 mm
1 kHz 0.4 kHz 0.8 kHz 0.1 kHz 0.5 kHz 0.1 kHz 0.1 kHz 0.1 kHz
*1
12 to 24 VDC. Ripple(p-p):10% max. (10~30 VDC)
13 mA max.
open collector, 200 mA max.
2 V max. (under load current of 200 mA with cable length of 2 m)
B1 Models: NO B2 Models: NC
Refer to the timing charts under Output Circurt Diagrams of page 7 for details.
Reverse polarity protection,Surge suppressor,Load short-circurt protection
Operating / Storage: -25~+70°C (with no icing or condensation)
Operating / Storage: 35~95% RH
±10% max. of sensing distance in rated voltage range ±15%
50 MΩ min. (at 500 VDC) between current carry parts and case
1,000 VAC, 50/60 Hz for 1 minute between current carry parts and case
10~55 Hz 0.75 mm double amplitude for 2 hours each in X,Y,and Z directions
500 m/s² 10 times each in X,Y,and Z directions
IEC 60529 IP67
Pre-wired models (Standard cable length: 2 m)
PBT
E2AG­S08KN02-@-B1 E2AG­S08KN02-@-B2
Iron 12×12×1 mm
E2AG­M12KS02-@-B1 E2AG­M12KS02-@-B2
1,000 m/s² 10 times each in X,Y,and Z directions
E2AG­M12KN05-@-B1 E2AG­M12KN05-@-B2
Iron 15×15×1 mm
E2AG­M18KS05-@-B1 E2AG­M18KS05-@-B2
Iron 18×18×1 mm
E2AG­M18KN10-@-B1 E2AG­M18KN10-@-B2
Iron 30×30×1 mm
E2AG­M30KS10-@-B1 E2AG­M30KS10-@-B2
E2AG­M30KN18-@-B1 E2AG­M30KN18-@-B2
Iron 54×54×1 mm
3E2AG
Page 4
Engineering data (typical)
Sensing Area
DC 3-wire models/shielded DC 3-wire models/unshielded
E2G-M30KS10-?-C/B?
E2G-M30KS10-?-C/B?
E2AG-M30KS10-@-C/B@
Distance X (mm)
Distance X (mm)
Distance X (mm)
E2G-M18KS05
E2G-M18KS05
E2AG-M18KS05
-?-C/B?
-?-C/B?
-@-C/B@
E2G-M12KS02
E2G-M12KS02
E2AG-M12KS02
-?-C/B?
-?-C/B?
@
-C/B
@
-
E2G-
E2G-
E2AG­S08KS01
S08KS01
S08KS01
-?-C/B?
-?-C/B?
-@-C/B@
Distance
Distance
Distance Y (mm)
Y (mm)
Y (mm)
Influence of sensing object size and material
DC 3-wire models/shielded
E2AG-S08KS01-@-C/B@
Distance X (mm)
Stainless steel
Brass
Aluminum
Iron
Distance X (mm)
E2AG-M12KS02-@-C/B@
Distance X (mm)
E2AG-M30KN18-@-C/B@
E2AG-M18KN10-@-C/B
E2AG-M12KN05
-@-C/B@
E2AG-S08KN02
-@-C/B@
Distance Y (mm)
Iron
Stainless
steel
Brass
Aluminum
@
Side length of sensing object d (mm) Side length of sensing object d (mm)
E2AG-M18KS05-@-C/B@ E2AG-M30KS10-@-C/B@
Iron
Distance X (mm)
Stainless steel
Distance X (mm)
Brass
Aluminum
Side length of sensing object d (mm) Side length of sensing object d (mm)
Iron
Stainless steel
Brass
Aluminum
4 Cylindrical Proximity Sensor
Page 5
DC 3-wire models/unshielded
E2AG-S08KN02
Distance X (mm)
Side length of sensing object d (mm) Side length of sensing object d (mm)
-@-C/B@
Stainless steel
Iron
Brass
Aluminum
Copper
E2AG-M12KN05
Distance X (mm)
-@-C/B@
Iron
Stainless steel
Brass
Aluminum
E2AG-M18KN10
Distance X (mm)
Side length of sensing object d (mm) Side length of sensing object d (mm)
-@-C/B@
Stainless steel
Aluminum
Iron
Brass
E2AG-M30KN18
Distance X (mm)
-@-C/B@
Stainless steel
Iron
Brass
Aluminum
5E2AG
Page 6
Dimensions (All units are millimeters unless particular indicated.)
Pre-wired models (shielded) Pre-wired models (unshielded)
Fig. A E2AG-S08KS01-WP-B Fig. B E2AG-S08KN02-WP-B
indicator
2-clamping nuts
toothed washer
*1 PVC round insulated cable 3-wire dia-4 (cross section of conductor: 0.3mm²,insulator diameter: φ1.3mm)standard 2m cable.
*1
2-clamping nuts
toothed washer
*1 PVC round insulated cable 3-wire dia-4 (cross section of conductor: 0.3mm²,insulator diameter: φ1.3mm)standard 2m cable.
Fig. C E2AG-M12KS02-WP-B Fig. D E2AG-M12KN05-WP-B
indicator
2-clamping nuts
toothed washer
*1 PVC round insulated cable 3-wire dia-4 (cross section of conductor: 0.3mm²,insulator diameter: φ1.3mm)standard 2m cable.
*1
*1 PVC round insulated cable 3-wire dia-4 (cross section of conductor: 0.3mm²,insulator diameter: φ1.3mm)standard 2m cable.
Fig. E E2AG-M18KS05-WS-B Fig. F E2AG-M18KN10-WS-B
indicator
2-clamping nuts
toothed washer
*1 PVC round insulated cable 3-wire dia-6 (cross section of conductor: 0.5mm²,insulator diameter: φ1.9mm)standard 2m cable.
*1
*1 PVC round insulated cable 3-wire dia-6 (cross section of conductor: 0.5mm²,insulator diameter: φ1.9mm)standard 2m cable.
Fig. G E2AG-M30KS10-WS-B Fig. H E2AG-M30KN18-WS-B
indicator
indicator
2-clamping nuts
toothed washer
indicator
2-clamping nuts
toothed washer
*1
*1
*1
indicator
2-clamping nuts
toothed washer
*1 PVC round insulated cable 3-wire dia-6 (cross section of conductor: 0.5mm²,insulator diameter: φ1.9mm)standard 2m cable.
*1
indicator
2-clamping nuts
toothed washer
*1 PVC round insulated cable 3-wire dia-6 (cross section of conductor: 0.5mm²,insulator diameter: φ1.9mm)standard 2m cable.
*1
Process Dimension Of Mounting Hole
Proximity Diameter
Dimension
6 Cylindrical Proximity Sensor
Page 7
Output circuit
Output Model
E2AG-@-@-B1 NO
PNP Open collector output
E2AG-@-@-B2 NC
Operation
mode
Non-sensing
Detection
object
(%)
Non-sensing
Detection
object
(%)
Timing chart Output circuit
zone
100 0
Rated
detection
distance
zone
100 0
Rated
detection
distance
Sensing
zone
Sensing
zone
Proximity switch
Operation
ON
indicator
OFF
(yellow)
ON
Output control
OFF
Proximity switch
Operation
ON
indicator
OFF
(yellow)
ON
Output
control
OFF
A
Brown
Proximity
Sensor
Main
Circuit
Black
Blue
D
C
(or B)
Load
NOTE: ABCD are the pins' numbers of the Connector.
Correct use
Effects of surrounding metal
Please keep the distance as the demensions of the following chart away from the surrounding metal.
Model Event M8 M12 M18 M30
l 0
d 8 12 18 30
Shielded
Unshielded
(Unit:mm)
Precaution for safe use
Power supply voltage
Do not use a voltage which exceeds the range of the rated voltage. Applying a voltage that is higher than the rated voltage or using an AC supply (220 V) for the sensor may cause sensor explosion or burning.
Load short-circuiting
Do not short-circuit the load,otherwise explosion or burning may occur. The load short-circuit protection function operates when the power supply is connected with the correct polarity and the power is within the rated voltage range.
D0
m4.5 8 20 40
n12182745
l 6152230
d24405590
D 6 15 22 30
m 8 20 40 70
n34365490
Mutual interference
Please use the value shown as the following chart when the the products are oppsite or parallel configurated.
Model Event M8 M12 M18 M30
Shielded
Unshielded
(Unit:mm)
A 20 30(20) 50(30) 100(50)
B 15 20(12) 35(18) 70(35)
A 80 120(60) 200(100) 300(100)
B 60 100(50) 110(60) 200(100)
Incorrect connection
Ensure that the power suppy polarity and other wiring is correct, oth­erwise incorrect wiring may cause explosion or burning.
7E2AG
Page 8
In the interest of product improvement, specifications are subject to change without notice.Cat. No. E61E-EN-01
8 Cylindrical Proximity Sensor
Loading...