Omron D5F-2B10, D5F-2B30, D5F-3C10, D5F-3C30 Datasheet

280
D5F High-precision Optical Switch
Optical System Achieves 1-mm Operating Position Repeatability in this 4-way Switch
A knife-edge mechanism in the optical system
provides greater precision for a more stable out­put without faulty contact operation.
Reduced size and weight (34 mm at operating
section and 60 g total).
Wear-resistive ceramic parts used in the mea-
surement section.
Two different output types available.
Ordering Information
List of Models
Specifications
Ratings
Characteristics
Note: 1. The above figures are initial values.
2. Life expectancy values are calculated at an operating temperature of 5
C to 35C, and an operating humidity of 40% to 70%.
Contact your OMRON sales representative for more detailed information on other operating environments.
3. Measurements were conducted repeatedly at the same point. The value is 1
m
m max. for 200 measurements. For other condi-
tions in detail, contact your OMRON sales representative.
4. The ambient operating temperature varies depending on the current. Refer to the following Engineering Data.
Output configuration Contact form Operation indicator Cable length Model
PNP open collector (+ common)
SPST-NC ON when not operated 1 m D5F-2B10
3 m D5F-2B30 NPN open collector (– common)
SPST-NO ON when operated 1 m D5F-3C10
3 m D5F-3C30
Power supply voltage 12/24 VDC10%, ripple (p–p): 10% max. Output current 100 mA max. Power consumptio n 30 mA max. Leakage current 0.15 mA max. Residual voltage 2 V max.
Degree of protection IP67 Life expec t an c y (see note 2) Mechanical: 5,000,000 operations min.
Electrical: 5,000,000 operations min.
Operating speed 1
m
m/s to 50 cm/s
Max. operating frequency 60 operations/minute max. Insulation resistance 100 M
W
min. (at 500 VDC) between each termina l and ground
Dielectric strength 1,100 VAC between each terminal and ground Vibration resistance Malfunction: 10 to 500 Hz, 1.3-mm double amplitude Shock resistance
Malfunction: 300 m/s
2
min.
Repeat accuracy 1
m
m max. (see note 3)
Ambient temperature (see note 4) Operating: –10
C to 60C (with no icing)
Ambient humidity Operating: 30% to 95% Weight Switch body: approx. 50 g; Cord: 23 g/m
281
D5FD5F
Note: :Operating position fluctuation rate for a change of 1C in the ambient temperature.
Operating Characteristics
Engineering Data
The permissible operating temperature range varies with the cur­rent flow as follows:
Deviation 10
m
m max. after 1,000,000 operations
Temperature coefficient
50 x 10–6/C max.
OF max. 2.45 N RF min. 0.98 N PT max. 0.5 mm MD max. 20
m
m
TT min. 2.2 mm
100
50 40
20
40 45
60
Current (mA)
Operating range
Operating temperature (°C)
Loading...