High-precision Switch for Detecting
Micron-unit Displacement
■ Ideal for detecting and meas uring wear of cutti ng
tools or for original point of work.
■ Direct input possible to micr oprocessors and pro -
grammable controllers.
■ Types available with built-in operation indicator for
ease of operation monito ring as well as a version
with fiber optics remote operation indicator.
■ A version with screw-type ca ble con nector avail-
able for easy installation and maintenance.
Application Examples
D5A High-precision Switch
Origin Position Control of an X-Y Table
Motor
Motor
Note: Origin can be set to a desired position and the origin
position can be controlled using the D5A.
D5A
Coaxiality Inspection
D5A
D5A
Note: The D5A can be mounted on a jig used for checking
deviation to inspect its coaxiality.
Checking Turret Indexing Position
Turret
D5A
Note: Set the D5A on the turret indexing position to check if
the turret is engaged properly at the specified position.
271
Ordering Information
■ List of Models
Contact Output Models (Without Operation Indicator)
D5AD5A
Actuator Type Repeat
Pin plunger M5 1
M8 1
M16 3
accuracy
m
m max. 0.29 N max. Pre-wired 1 m IP40 D5A-1100
3
m
m max. 0.29 N max. D5A-2100
m
m max. 0.49 N max. IP67 D5A-3200
m
m max. 2.45 N max. D5A-7400
Operating force Cable lead outlet Degree of
0.49 N max. D5A-1200
0.49 N max. D5A-2200
0.98 N max. D5A-3300
Solid-state Output Models (With Operation Indicator)
Actuator Type Repeat
Pin plunger M8 1
Slim 0.49 N max. D5A-5210
M16 3
Top plunger
Bevel plunger
Limit 3
accuracy
m
m max.
m
m max. 2.45 N max. D5A-7410
m
m max.
Operating force Cable lead outlet Degree of
0.49 N max. Pre-wired 1 m IP67 D5A-3210
0.98 N max. D5A-3310
0.98 N max. D5A-5310
3.92 N max. Pre-wired 3 m D5A-8511
Type Length
Connector D5A-7403
Type Length
Connector D5A-7413
5 m D5A-8512
Connector 3 m D5A-8514
5 m D5A-8515
Pre-wired 3 m D5A-9511
5 m D5A-9512
Connector 3 m D5A-9514
5 m D5A-9515
protection
protection
Model
Model
Specifications
■ Ratings
Contact output models 10 mA at 24 VAC, 10 mA at 12 VDC
Solid-state output models 100 mA at 5 to 24 VDC
Leakage current: 0.15 mA max.
Residual voltage: 3 V max.
Power consumption: 3 mW max.
10%
272
■ Characteristics
#
Degree of protection D5A-1
Repeat accuracy (see note 2) M5 (D5A-1
Life expectancy (see note 3) Mechanical: 10,000,000 operations min.
Deviation in electrical life expectancy after 1,000,000 operations
Operating speed 1
Rated frequency 50/60 Hz
Insulation resistance 100 M
Contact resistance 800 m
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between each terminal and ground
Vibration resistance Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance
Temperature coefficient
(see note 4)
Ambient temperature Operating: –20
Ambient humidity Operating: 30% to 85% (30% to 95% with the seal rubber)
, D5A-2#: IP40
Other than the above models: IP67
###
series), M8, slim type:1 mm max.
###
M5 (D5A-2
Malfunction: 1,000,000 operations min. (under rated load)
M5, M8, M16, slim type: 10
Limit type : 20
m
m to 0.5 m/s
W
W
W
max. (initial) with 3 m cable, 4 W max. (initial) with 5 m cable)
2.4
Mechanical: 1,000 m/s
Malfunction: 300 m/s
M5, M8, slim type:
M16 type:
Limit type :
series), M16, limit type:3 mm max.
m
m max.
m
m max.
min. (at 250 VDC) between each terminal and ground
max. (initial) with 1 m cable,
2
min.
2
min.
20 x 10–6/C max.
40 x 10–6/C max.
50 x 10–6/C max.
C to 75C (with no icing)
D5AD5A
Note: 1. The above figures are initial values.
2. Contact your OMRON sales representative for measurement conditions of the repeat accuracy.
3. Life expectancy values are calculated at an operating temperature of 5
Contact your OMRON sales representative for more detailed information on other operating environments.
4. The value indicates the operating position change rate for a change of 1
■ Operating Characteristics
Model D5A-1100
OF max. 0.29 N 0.49 N 0.49 N 0.98 N 0.49 N 0.98 N
OT min. 1.5 mm 1.5 mm 1.5 mm 1.5 mm 1.5 mm 1.5 mm
MD max. 5
OP
(see note 1)
Model D5A-7400/-7410
OF max. 2.45 N 3.93 N
PT max. 1 mm 1 mm
OT min. 2 mm 5 mm 4 mm
MD max. 5
OP (4.4 mm) 21.0
FP (5 mm) (21.8 mm) (15.8 mm)
Note: 1. The operating position of these types is the same as the free position because of high sensitivity (repeat accuracy: 1 mm max.).
2. Total movement is 1.9 to 2.1 mm. Set the appropriate stroke (plunging depth) to 1.0 to 1.5 mm from the FP.
D5A-2100
(see note 2)
m
m5
(2 mm) (2 mm) (6.5 mm) (6.5 mm) 10.5
D5A-7403/-7413
m
m5
D5A-1200
D5A-2200
(see note 2)
m
m5
D5A-3200
D5A-3210
(see note 2)
m
m5
D5A-8511/-8514
D5A-8512/-8515
m
m5
0.4 mm 15.20.4 mm
C to 35C, and an operating humidity of 40% to 70%.
C in the ambient temperature.
D5A-3300
D5A-3310
(see note 2)
m
m5
D5A-5210
(see note 2)
m
m5
0.4 mm 10.50.4 mm
D5A-9511/-9514
D5A-9512/-9515
m
m
D5A-5310
(see note 2)
m
m
273