Omron D5A DATASHEET

High-precision Switch for Detecting Micron-unit Displacement
Ideal for detecting and meas uring wear of cutti ng
tools or for original point of work.
Direct input possible to micr oprocessors and pro -
grammable controllers.
ease of operation monito ring as well as a version with fiber optics remote operation indicator.
A version with screw-type ca ble con nector avail-
able for easy installation and maintenance.
Application Examples
D5A High-precision Switch
Origin Position Control of an X-Y Table
Motor
Motor
Note: Origin can be set to a desired position and the origin
position can be controlled using the D5A.
D5A
Coaxiality Inspection
D5A
D5A
Note: The D5A can be mounted on a jig used for checking
deviation to inspect its coaxiality.
Checking Turret Indexing Position
Turret
D5A
Note: Set the D5A on the turret indexing position to check if
the turret is engaged properly at the specified position.
271
Ordering Information
List of Models
Contact Output Models (Without Operation Indicator)
D5AD5A
Actuator Type Repeat
Pin plunger M5 1
M8 1
M16 3
accuracy
m
m max. 0.29 N max. Pre-wired 1 m IP40 D5A-1100
3
m
m max. 0.29 N max. D5A-2100
m
m max. 0.49 N max. IP67 D5A-3200
m
m max. 2.45 N max. D5A-7400
Operating force Cable lead outlet Degree of
0.49 N max. D5A-1200
0.49 N max. D5A-2200
0.98 N max. D5A-3300
Solid-state Output Models (With Operation Indicator)
Actuator Type Repeat
Pin plunger M8 1
Slim 0.49 N max. D5A-5210
M16 3
Top plunger
Bevel plunger
Limit 3
accuracy
m
m max.
m
m max. 2.45 N max. D5A-7410
m
m max.
Operating force Cable lead outlet Degree of
0.49 N max. Pre-wired 1 m IP67 D5A-3210
0.98 N max. D5A-3310
0.98 N max. D5A-5310
3.92 N max. Pre-wired 3 m D5A-8511
Type Length
Connector D5A-7403
Type Length
Connector D5A-7413
5 m D5A-8512
Connector 3 m D5A-8514
5 m D5A-8515
Pre-wired 3 m D5A-9511
5 m D5A-9512
Connector 3 m D5A-9514
5 m D5A-9515
protection
protection
Model
Model
Specifications
Ratings
Contact output models 10 mA at 24 VAC, 10 mA at 12 VDC Solid-state output models 100 mA at 5 to 24 VDC
Leakage current: 0.15 mA max. Residual voltage: 3 V max. Power consumption: 3 mW max.
10%
272
Characteristics
#
Degree of protection D5A-1
Repeat accuracy (see note 2) M5 (D5A-1
Life expectancy (see note 3) Mechanical: 10,000,000 operations min.
Deviation in electrical life expectan­cy after 1,000,000 operations
Operating speed 1 Rated frequency 50/60 Hz Insulation resistance 100 M Contact resistance 800 m
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between each terminal and ground Vibration resistance Malfunction: 10 to 55 Hz, 1.5-mm double amplitude Shock resistance
Temperature coefficient (see note 4)
Ambient temperature Operating: –20 Ambient humidity Operating: 30% to 85% (30% to 95% with the seal rubber)
, D5A-2#: IP40
Other than the above models: IP67
###
series), M8, slim type:1 mm max.
###
M5 (D5A-2
Malfunction: 1,000,000 operations min. (under rated load) M5, M8, M16, slim type: 10
Limit type : 20
m
m to 0.5 m/s
W W
W
max. (initial) with 3 m cable, 4 W max. (initial) with 5 m cable)
2.4
Mechanical: 1,000 m/s Malfunction: 300 m/s
M5, M8, slim type: M16 type: Limit type :
series), M16, limit type:3 mm max.
m
m max.
m
m max.
min. (at 250 VDC) between each terminal and ground max. (initial) with 1 m cable,
2
min.
2
min.
20 x 10–6/C max.
40 x 10–6/C max.
50 x 10–6/C max.
C to 75C (with no icing)
D5AD5A
Note: 1. The above figures are initial values.
2. Contact your OMRON sales representative for measurement conditions of the repeat accuracy.
3. Life expectancy values are calculated at an operating temperature of 5 Contact your OMRON sales representative for more detailed information on other operating environments.
4. The value indicates the operating position change rate for a change of 1
Operating Characteristics
Model D5A-1100
OF max. 0.29 N 0.49 N 0.49 N 0.98 N 0.49 N 0.98 N OT min. 1.5 mm 1.5 mm 1.5 mm 1.5 mm 1.5 mm 1.5 mm MD max. 5 OP
(see note 1)
Model D5A-7400/-7410
OF max. 2.45 N 3.93 N PT max. 1 mm 1 mm OT min. 2 mm 5 mm 4 mm MD max. 5 OP (4.4 mm) 21.0 FP (5 mm) (21.8 mm) (15.8 mm)
Note: 1. The operating position of these types is the same as the free position because of high sensitivity (repeat accuracy: 1 mm max.).
2. Total movement is 1.9 to 2.1 mm. Set the appropriate stroke (plunging depth) to 1.0 to 1.5 mm from the FP.
D5A-2100
(see note 2)
m
m5
(2 mm) (2 mm) (6.5 mm) (6.5 mm) 10.5
D5A-7403/-7413
m
m5
D5A-1200 D5A-2200
(see note 2)
m
m5
D5A-3200 D5A-3210
(see note 2)
m
m5
D5A-8511/-8514 D5A-8512/-8515
m
m5
0.4 mm 15.20.4 mm
C to 35C, and an operating humidity of 40% to 70%.
C in the ambient temperature.
D5A-3300 D5A-3310
(see note 2)
m
m5
D5A-5210
(see note 2)
m
m5
0.4 mm 10.50.4 mm
D5A-9511/-9514 D5A-9512/-9515
m
m
D5A-5310
(see note 2)
m
m
273
Loading...