Note: Approval for CSA C22.2 No. 14 is authorized by the UL mark.
Standards and EC Directives
• Conforms to the following EC Directives:
Machinery Directive
Low Voltage Directive
EN50047
EN1088
CCC (China Compulsory Certification) Mark
AgencyStandardFile No.
CQCGB14048.5Under
EN60947-5-1 (approved
direct opening)
GS-ET-15
B0306 39656052
application
Approved Standard Ratings
TÜV (EN60947-5-1)
Item
Rated operating current (I
Rated operating voltage (U
Note: Use a 10-A fuse type gI or gG that conforms to IEC269 as a short-circuit
protection device. This fuse is not built into the Switch.
Utilization
category
) 3 A0.27 A
e
e
UL/CSA (UL508, CSA C22.2 No. 14)
A300
Rated
voltage
120 VAC 10 A60 A6 A7,200 VA 720 VA
240 VAC30 A3 A
Carry currentCurrentVolt-amperes
AC-15DC-13
) 240 V250 V
MakeBreakMakeBreak
D4NS
G-133D4NS
Characteristics
Degree of protection (See note 3.)IP67 (EN60947-5-1)
Durability
(See note 4.)
Mechanical1,000,000 operations min.
Electrical500,000 operations min. for a resistive load of 3 A at 250 VAC (See note 5.)
Operating speed0.05 to 0.5 m/s
Operating frequency30 operations/minute max.
Direct opening force (See note 6.)60 N min.
Direct opening travel (See note 6.)10 mm min.
Contact resistance25 mΩ max.
Minimum applicable load (See note 7.)Resistive load of 1 mA at 5 VDC (N-level reference value)
Rated insulation voltage (U
)300 V
i
Protection against electric shockClass II (double insulation)
Pollution degree (operating environment)3 (EN60947-5-1)
Impulse withstand voltage (EN60947-5-1)Between terminals of the same polarity2.5 kV
Insulation resistance100 MΩ min.
Contact gap2 x 2 mm min
Vibration resistance Malfunction10 to 55 Hz, 0.75-mm single amplitude
Shock resistanceDestruction
Malfunction
Conditional short-circuit current100 A (EN60947-5-1)
Rated open thermal current (I
)10 A (EN60947-5-1)
th
Ambient temperatureOperating: -30° C to 70° C with no icing
Ambient humidityOperating: 95% max.
WeightApprox. 96 g (D4NS-1CF)
(This applies for the Switch only. The degree of protection for the key hole is IP00.)
300,000 operations min. for a resistive load of 10 A at 250 VAC
Between terminals of different polarities4 kV
Between other terminals and uncharged metallic parts 6 kV
2
2
min.
min.
1,000 m/s
300 m/s
Note: 1. The above values are initial values.
2. Once a contact has been used to switch a standard load, it cannot be used for a load of a smaller capacity. Doing so may result in rough-
ening of the contact surface and contact reliability may be lost.
3. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are suffi-
cient for the operating conditions and environment beforehand. Although the switch box is protected from dust or water penetration, do
not use the D4NS in places where foreign material may penetrate through the key hole on the head, otherwise Switch damage or malfunctioning may occur.
4. The durability is for an ambient temperature of 5° C to 35° C and an ambient humidity of 40% to 70%. For more details, consult your
OMRON representative.
5. If the ambient temperature is greater than 35° C, do not pass the 3-A, 250-VAC load through more than 2 circuits.
6. These figures are minimum requirements for safe operation.
7. This value will vary with the switching frequency, environment, and reliability level. Confirm that correct operation is possible with the ac-
tual load beforehand.